(234 days)
When used as a pedicle screw fixation system in the non-cervical posterior spine in skeletally mature patients, the Mahe Perfect Spine - Pedicle Screw System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic. Iumbar and sacral spine: (1) degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), (2) degenerative spondylolisthesis with objective evidence of neurologic impairment, (3) fracture, (4) dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), (5) tumor, and (6) failed previous fusion (i.e. pseudarthrosis). In addition, when used as a pedicle screw system placed between L3 and S1, the Mahe Perfect Spine - Pedicle Screw System is indicated for the treatment of severe spondylolisthesis (Grade 3 and 4) in skeletally mature patients receiving fusion with autologous bone graft and with removal of the device after solid fusion is established.
When used as a posterior, non-cervical, non-pedicle screw fixation system, the Mahe Perfect Spine - Pedicle Screw System is intended for use in skeletally mature patients and pediatric patients for the following indications: (1) degenerative disc disease (as defined by back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), (2) spondylolisthesis, (3) fracture, (4) spinal deformities (i.e., scoliosis, kyphosis, and/or lordosis), (5) spinal stenosis, (6) tumor resection, and/or (7) unsuccessful previous attempts at spinal fusion (pseudoarthrosis).
When intended for anterolateral fixation of the T6-L5 spine the Mahe Perfect Spine - Pedicle Screw System is indicated for: (1) degenerative disc disease (back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), (2) spondylolisthesis, (3) trauma (i.e. fracture or dislocation), (4) spinal stenosis, (5) deformities or curvatures (i.e. scoliosis, kyphosis, and/or lordosis}, (6) tumor and (7) failed previous fusion.
The Mahe Perfect Spine - Pedicle Screw System consists of a variety of shapes and sizes of rods, hooks, monoaxial and polyaxial screws, cross connectors, as well as appropriate instrumentation.
The Mahe Perfect Spine - Pedicle Screw System components are fabricated from titanium alloy per ASTM F136.
The system is sold non-sterile, the products have to be sterilized prior to use.
The provided text details a 510(k) submission for the Mahe Perfect Spine - Pedicle Screw System. This is a medical device for spinal fixation, not an AI/ML powered device. As such, the concept of "acceptance criteria" and "study that proves the device meets the acceptance criteria" as it relates to AI/ML device performance (e.g., accuracy, sensitivity, specificity, F1-score) is not applicable here.
Instead, the submission focuses on demonstrating substantial equivalence to existing predicate devices based on non-clinical performance data and technological characteristics.
Here's how the information provided relates to the typical framework for medical device clearance in this context:
1. Table of Acceptance Criteria and Reported Device Performance:
Since this is not an AI/ML device, there are no "acceptance criteria" for metrics like sensitivity or accuracy. The "acceptance criteria" here are implicit in demonstrating substantial equivalence through mechanical testing, material specifications, and intended use.
| Acceptance Criteria (Implicit for Substantial Equivalence) | Reported Device Performance |
|---|---|
| Mechanical Performance (Worst-case construct) | Demonstrated comparable mechanical properties to predicate devices through testing per ASTM F1717-10 (static compression bending, static torsion, dynamic compression bending) and ASTM F2193-02, ASTM F1798. |
| Material Composition | Fabricated from titanium alloy per ASTM F136, similar to predicate devices. |
| Design and Configuration | Similar in classification, intended use, levels of attachment, materials, design, sizes, and configurations to predicate devices. |
| Manufacturing and Sterilization Methods | Similar to predicate devices. |
| Indications for Use | Aligned with the indications for use of predicate devices (for various spinal instabilities/deformities in the non-cervical posterior spine, and later for posterior non-pedicle screw fixation and anterolateral fixation). |
2. Sample Size Used for the Test Set and Data Provenance:
- Test Set: The "test set" in this context refers to the samples of the device components that underwent mechanical testing. The specific number of samples for each test (static compression bending, static torsion, dynamic compression bending, etc.) is not explicitly stated in the provided text.
- Data Provenance: The data comes from non-clinical laboratory testing performed on the device itself ("the worst case construct"). There is no mention of country of origin for the data or whether it's retrospective or prospective, as it's a materials/mechanical engineering study, not a clinical trial.
3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Those Experts:
- This question is not applicable to this type of device submission. "Ground truth" in the context of expert consensus is relevant for diagnostic AI/ML devices where experts annotate data for algorithm training and evaluation. For a spinal fixation system, the "ground truth" for its performance is derived from standardized mechanical testing against established engineering benchmarks and comparison to predicate devices, not expert human assessment of images or clinical outcomes in a test set.
4. Adjudication Method:
- Not applicable. Adjudication methods (like 2+1, 3+1) are used for resolving disagreements among human experts in establishing ground truth for diagnostic AI/ML systems. This is a mechanical device, not an AI/ML diagnostic.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:
- No. An MRMC study is relevant for evaluating the impact of AI on human reader performance in diagnostic tasks. This device is a surgical implant, not a diagnostic tool that assists human readers.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:
- Not applicable. This submission is for a physical medical device, not a software algorithm.
7. The Type of Ground Truth Used:
- The "ground truth" for this device's performance is derived from objective, standardized mechanical testing results (e.g., measurements of bending strength, torsion resistance, fatigue life) compared against established performance characteristics of legally marketed predicate devices and relevant industry standards (ASTM F1717-10, ASTM F2193-02, ASTM F1798).
8. The Sample Size for the Training Set:
- Not applicable. There is no "training set" in the context of a mechanical medical device submission. Training sets are for machine learning algorithms.
9. How the Ground Truth for the Training Set Was Established:
- Not applicable. As there is no training set, this question is not relevant.
In summary: The provided document is for a traditional medical device (spinal fixation system) seeking 510(k) clearance based on substantial equivalence to predicate devices, primarily supported by non-clinical mechanical performance data and material specifications. The questions concerning AI/ML evaluation metrics, expert consensus, and ground truth establishment for algorithms are outside the scope of this submission.
{0}------------------------------------------------
K 110 655
510(k) Summary
mahemedica
510(k) Summary as required by section 807.92(c)
Submission Applicant: Mahe Medical GmbH Establishment Registration Number: 8010447 Phone: +49-7465-92750 Fax: +49-7465-927529 E-mail: ralf.rotter@mahe-med.de
Application Correspondent/Contact: think ! Andrea Pecsi Schwarzwaldstraße 5 78532 Tuttlingen Germany Phone: +49-7462-924 051 Fax: +49-7462-924 128 E-mail: andrea@thinkworks.biz
Date: 8/27/2011
Trade name: Mahe Perfect Spine - Pedicle Screw System
Common names: Pedicle Screw System, Spinal Fixation System, Stabilization System
Classification name: Spinal interlaminal fixation orthosis; Spinal intervertebral body fixation orthosis; Pedicle screw spinal system (21 CFR 888.3050, 888.3060, 888.3070)
Product codes: NKB, KWP, KWQ, MNH, MNI
Class: III
Predicate Devices:
K051971 - OPTIMATM Spinal System, U&1 Corporation > K021564 - InCompass Spinal Fixation System, Spinal Concepts, Inc. > K052123 - Pangea TM System, Synthes Spine
Description of the Device:
The Mahe Perfect Spine - Pedicle Screw System consists of a variety of shapes and sizes of rods, hooks, monoaxial and polyaxial screws, cross connectors, as well as appropriate instrumentation.
The Mahe Perfect Spine - Pedicle Screw System components are fabricated from titanium alloy per ASTM F136.
The system is sold non-sterile, the products have to be sterilized prior to use.
{1}------------------------------------------------
510(k) Summary
Indications for Use:
When used as a pedicle screw fixation system in the non-cervical posterior spine in skeletally mature patients, the Mahe Perfect Spine - Pedicle Screw System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic. Iumbar and sacral spine: (1) degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), (2) degenerative spondylolisthesis with objective evidence of neurologic impairment, (3) fracture, (4) dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), (5) tumor, and (6) failed previous fusion (i.e. pseudarthrosis). In addition, when used as a pedicle screw system placed between L3 and S1, the Mahe Perfect Spine - Pedicle Screw System is indicated for the treatment of severe spondylolisthesis (Grade 3 and 4) in skeletally mature patients receiving fusion with autologous bone graft and with removal of the device after solid fusion is established.
When used as a posterior, non-cervical, non-pedicle screw fixation system, the Mahe Perfect Spine - Pedicle Screw System is intended for use in skeletally mature patients and pediatric patients for the following indications: (1) degenerative disc disease (as defined by back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), (2) spondylolisthesis, (3) fracture, (4) spinal deformities (i.e., scoliosis, kyphosis, and/or lordosis), (5) spinal stenosis, (6) tumor resection, and/or (7) unsuccessful previous attempts at spinal fusion (pseudoarthrosis).
When intended for anterolateral fixation of the T6-L5 spine the Mahe Perfect Spine - Pedicle Screw System is indicated for: (1) degenerative disc disease (back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), (2) spondylolisthesis, (3) trauma (i.e. fracture or dislocation), (4) spinal stenosis, (5) deformities or curvatures (i.e. scoliosis, kyphosis, and/or lordosis), (6) tumor and (7) failed previous fusion.
Technological characteristics compared to the Predicate Devices:
The features of the subject components are substantially equivalent to the predicate devices based on similarities in classification, intended use, levels of attachment, materials, design, sizes and configurations. In addition, the manufacturing and sterilization methods of the predicate and subject components are similar.
Non-clinical performance data:
The following tests were performed on the worst case construct per ASTM F1717-10: static compression bending, static torsion and dynamic compression bending. Additional testing was also performed per ASTM F2193-02 and ASTM F1798. The mechanical testing demonstrates the comparable mechanical properties of the Mahe Perfect Spine - Pedicle Screw System to predicate devices.
Summary:
The presented data demonstrates that the Mahe Perfect Spine - Spinal Fixation System should perform similarly to the predicate devices. The Mahe Perfect Spine - Spinal Fixation System can be deemed substantially equivalent for its indicated use.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the seal of the Department of Health & Human Services-USA. The seal features a stylized eagle-like symbol with three curved lines representing its body and wings. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES-USA" is arranged in a circular pattern around the symbol.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
OCT 2 7 2011
Mahe Medical GmbH % Think Ms. Andrea Pecsi Schwarzwaldstraße 5 78532 Tuttlingen, Germany
Re: K110655
Trade/Device Name: Mahe Perfect Spine - Pedicle Screw System Regulation Number: 21 CFR 888.3070 Regulation Name: Pedicle screw spinal system Regulatory Class: Class III Product Code: NKB, MNH, MNI, KWP, KWQ Dated: August 29, 2011 Received: September 26, 2011
Dear Ms. Pecsi:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act . The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbrandi, nound adulteration. Please note: CDRH does not evaluate information related to contractly ahility warranties. We remind you; however, that device labeling must be truthful and not miolery
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other manuton voor not not hot hot
{3}------------------------------------------------
Page 2 - Ms. Andrea Pecsi
or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely vours.
Emil Keith
So Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Indications for Use Statement
510(k) Number (if known): K110655
Device Name: Mahe Perfect Spine - Pedicle Screw System
Indications for Use:
When used as a pedicle screw fixation system in the non-cervical posterior spine in skeletally mature patients, the Mahe Perfect Spine - Pedicle Screw System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: (1) degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), (2) degenerative spondylolisthesis with objective evidence of neurologic impairment, (3) fracture, (4) dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), (5) tumor, and (6) failed previous fusion (i.e. pseudarthrosis). In addition, when used as a pedicle screw system placed between L3 and S1, the Mahe Perfect Spine - Pedicle Screw System is indicated for the treatment of severe spondy lolisthesis (Grade 3 and 4) in skeletally mature patients receiving fusion with autologous bone graft and with removal of the device after solid fusion is established.
When used as a posterior, non-cervical, non-pedicle screw fixation system, the Mahe Perfect Spine - Pedicle Screw System is intended for use in skeletally mature patients and pediatric patients for the following indications: (1) degenerative disc disease (as defined by back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), (2) spondylolisthesis, (3) fracture, (4) spinal deformities (i.e., scoliosis, kyphosis, and/or lordosis), (5) spinal stenosis, (6) tumor resection, and/or (7) unsuccessful previous attempts at spinal fusion (pseudoarthrosis).
When intended for anterolateral fixation of the T6-L5 spine the Mahe Perfect Spine - Pedicle Screw System is indicated for: (1) degenerative disc disease (back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), (2) spondylolisthesis, (3) trauma (i.e. fracture or dislocation), (4) spinal stenosis, (5) deformities or curvatures (i.e. scoliosis, kyphosis, and/or lordosis}, (6) tumor and (7) failed previous fusion.
Prescription Use X (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Division Sign-Off) Division of Surgical, Orthopedic, and Restorative Devices
Page 1 of ____________________________________________________________________________________________________________________________________________________________________
KIIDSSS 510(k) Number
N/A