The Novel III Spinal System is a pedicle screw system indicated for the treatment of severe Spondylolisthesis (Grade 3 and 4) of the L5-S 1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion. In addition, the Novel Spinal System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic lumbar and sacral spine: degenerative Spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor and failed previous fusion (pseudarthrosis).
The Novel ///™ Spinal Fixation and Adjustable Bridge System is a top-loading posterior spinal fixation system which consists of pedicle screws, rods, set screws, and a transverse (cross) linking mechanism. The Novel III TM Spinal Fixation and Adjustable Bridge System implant components are fabricated from titanium alloy (Ti-6AI-4V ELI) that conforms to ASTM F 136. Various sizes of these implants are available. Specialized instruments made from surgical instrument grade stainless steel are available for the application and removal of the Novel ///™ Spinal Fixation and Adjustable Bridge System implants.
The provided text is a 510(k) summary for the Novel III™ Spinal Fixation and Adjustable Bridge System, which is a medical device. This type of document focuses on establishing substantial equivalence to a predicate device, primarily through mechanical testing and comparison of design and intended use.
Therefore, the document does not contain the information requested in points 1-9, as those details are typically associated with clinical trials or studies assessing diagnostic performance, which are not relevant for this type of device submission.
Here's a breakdown of why the information is not present:
- Acceptance Criteria and Device Performance (1): Not applicable for this type of device. The acceptance criteria here would be meeting the mechanical testing standards (ASTM F 1717-04 for the predicate, and implied substantial equivalence for the modified device). No specific reported "performance" in the sense of diagnostic accuracy or a clinical outcome study is provided or required for a device modification of this nature.
- Sample Size, Data Provenance (2): No clinical test set involving patients is described. The "test set" refers to the components tested in mechanical validation.
- Number of Experts, Qualifications (3): No expert ground truth establishment for a test set is described.
- Adjudication Method (4): Not applicable as there's no interpretation of clinical data by experts.
- MRMC Comparative Effectiveness Study (5): This is a mechanical device, not an AI or diagnostic tool where human readers would improve with AI assistance.
- Standalone Performance (6): "Algorithm only without human-in-the-loop performance" is not relevant for a spinal fixation system.
- Type of Ground Truth (7): Not applicable. The "ground truth" for this device is its mechanical integrity and ability to perform its intended structural support function, verified by engineering and material standards, not by clinical pathology or outcomes in a study for this submission.
- Sample Size for Training Set (8): No training set as this is not an AI/ML device requiring training data.
- Ground Truth for Training Set (9): Not applicable, as there's no training set.
Summary of what is present and relevant to the 510(k) in relation to 'testing':
The submission indicates that the predicate device (Novel™ Spinal System) underwent mechanical testing, including:
- Static Compression Bending
- Static Tension Bending
- Static Torsional
- Dynamic Compression Fatigue Testing
All these tests were performed per ASTM F 1717-04.
The subject device (Novel III™ Spinal Fixation and Adjustable Bridge System) "contains dimensionally modified components (not worst case) and therefore not subject to ASTM F 1717-04 additional testing." This implies that because the modifications were not considered "worst case" in terms of mechanical stress, the new device was deemed substantially equivalent to the predicate without needing to repeat all the same mechanical tests. The acceptance criteria for the subject device are therefore implicitly:
- Substantial Equivalence: The modified components do not negatively impact the mechanical performance already established for the predicate device.
- Compliance with ASTM F 1717-04 (by proxy via predicate): The predicate device met these standards, and the modifications to the subject device are not considered to compromise that compliance.
In essence, the "study" proving the device meets acceptance criteria is the mechanical testing of the predicate device against ASTM F 1717-04, and the subsequent engineering analysis that concluded the modifications in the Novel III™ system did not require new, full-scale mechanical testing due to their non-worst-case nature.
{0}------------------------------------------------
510(k) SUMMARY
DEC 1 6 2010
!
"Special 510 (K): Device Modification" Premarket Notification: Novel III™ Spinal Fixation and Adjustable Bridge System
1. Submitter/Sponsor:
Medvssev Co. Ltd. Patrick D. Moore, Official US Correspondent 722-3, 4F. Science Tower, Jihaeng-dong, Dongducheon-city, Gyeonggi-do, Korea
Contact person:
Patrick D. Moore Official US Correspondent Medyssey Co. Ltd. 6170 South 380 West, Suite 200. Murray, Utah. 84107 801-266-4811, Fax. 801-266-4363; E-Mail: pdmoore@jemospine.com Tel.
Date Prepared:
October 20, 2010
2. Device Name:
| Classification Name: | Pedicle Screw Spinal Fixation System |
|---|---|
| Common/Generic Name: | Pedicle Screw Spinal System |
| Trade Name: | Novel III ™ Spinal Fixation and Adjustable Bridge System |
3. Device Classification(s):
Class II (88.3390) following Orthopedic and Rehabilitation Device Advisory Review, for the requested indications:
- Spinal Pedicle Screw (MNI) 21 CFR § 888.3070 .
- Spondylolisthesis Spinal Fixation Device System (MNH) 21 CFR § . 888.3070
- Spinal Intervertebral Body Fixation Orthosis (KWQ) 21 CFR § 888.3060 .
4. Predicate Device:
Medyssey Co., Ltd., Novel™ Spinal System - MNI, MNH, KWQ -- (K081153)
5. Device Description:
The Novel ///™ Spinal Fixation and Adjustable Bridge System is a top-loading posterior spinal fixation system which consists of pedicle screws, rods, set screws, and a transverse (cross) linking mechanism. The Novel III TM Spinal Fixation and Adjustable Bridge System implant components are fabricated from titanium alloy (Ti-6AI-4V ELI) that conforms to ASTM F 136. Various sizes of these implants are available.
$\rho$ 1.of2
E. Page 24
{1}------------------------------------------------
K10 3147
Specialized instruments made from surgical instrument grade stainless steel are available for the application and removal of the Novel ///™ Spinal Fixation and Adjustable Bridge System implants.
6. Intended Use:
The Novel III Spinal System is a pedicle screw system indicated for the treatment of severe Spondvlolisthesis (Grade 3 and 4) of the L5-S 1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.
In addition. the Novel Spinal System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic lumbar and sacral spine: degenerative Spondvlolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor and failed previous fusion (pseudarthrosis).
- Comparison with predicate device: The Novel ///™ Spinal System is substantially equivalent to the currently marketed Novel™ Spinal System. When considered for anterior applications, both the Novel ///TM Spinal Fixation and Adjustable Bridge System and the Nove/™ Spinal System worst case constructs consist of the same universal housing containing the same pre-assembled pedicle screw and set screw. Both systems use the same vertical rods which are both placed into the housing. The same set screws are subsequently tightened onto the rod. providing a completed implant assembly.
The principles of operation for the subject Novel ///™ Spinal Fixation and Adjustable Bridge System device, and the cited predicate technologies are same. That is, each of these products employs the same indications for use, contraindications for use, warnings and precautions within labeling. The principles of operation of the subject device are directly equivalent to those of the cited predicates cleared by the Agency and currently being marketed.
The design and development process of the manufacturer of subject system and Predicate system conforms to 21 CFR part 820, ISO 9001 and ISO 13485 quality systems.
The subject and predicate device was evaluated/tested per established requirements. . .
The predicate device underwent mechanical testing included Static Compression Bending; Static Tension Bending; Static Torsional; also Dynamic Compression Fatigue Testing. All testing performed per ASTM F 1717-04. The subject device contains dimensionally modified components (not worst case) and therefore not subject to ASTM F 1717-04 additional testing.
p. 2 of 2
Page 3 of 24
Page 2 of 24
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services USA. The logo consists of a stylized eagle with three lines forming its body and wings. The eagle is positioned within a circular border that contains the text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" in a circular arrangement.
Food and Drug Administration 1 (0903 New Hampshire Avenue Document Control Room -- WO66-G609 Silver Spring. MD 20993-0002
Medyssev Co. Ltd. % Mr. Patrick Moore Official US Correspondent 6170 South 380 West, Suite 200 Murray, Utah 84107
DEC 16 2010
Re: K103147
Trade/Device Name: Novel III™ Spinal Fixation and Adjustable Bridge System Regulation Number: 21 CFR 888.3070 Regulation Name: Pedicle screw spinal system Regulatory Class: Class II Product Code: MNI, MNH, KWQ Dated: November 30, 2010 Received: December 2, 2010
Dear Mr. Moore:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set
{3}------------------------------------------------
Page 2 - Mr. Patrick Moore
forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH0ffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers. International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely vours.
Mule A. Mckenn
Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
K103147
510(k) Number (original): Koor 153 "Special 510(k). Device Modification" Number (if known):
DEC 1 6 2010
Device Name: Novel III™ Spinal Fixation and Adiustable Bridge System
Indications for Use: The Novel III Spinal System is a pedicle screw system indicated for the treatment of severe Spondylolisthesis (Grade 3 and 4) of the L5-$ 1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion. In addition, the Novel Spinal System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic lumbar and sacral spine: degenerative Spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor and failed previous fusion (pseudarthrosis).
Prescription Use______________________________________________________________________________________________________________________________________________________________ X (Per 21 CFR 801.109) (Optional Format 1-2-96)
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH. Office of Device Evaluation (ODE)
Mark A. Millkum
(Division Sign-Off) (Division Sign-Off)
Division of Surgical, Orthopedic,
Division of Surgical, Devices Division of Surgh
and Restorative Devices and Restorative Devices
510(k) Number _
P. L.L
N/A