INVADER MTHFR 1298

K100496 · Hologic, Inc. · OMM · Apr 25, 2011 · Hematology

Device Facts

Record IDK100496
Device NameINVADER MTHFR 1298
ApplicantHologic, Inc.
Product CodeOMM · Hematology
Decision DateApr 25, 2011
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 864.7280
Device ClassClass 2
AttributesSoftware as a Medical Device

Intended Use

The Invader® MTHFR 1298 test is an in vitro diagnostic test intended for the detection and genotyping of a single point mutation (A to C at position 1298) of the human 5,10-methylenetetrahydrofolate reductase (MTHFR) gene in isolated genomic DNA obtained from whole blood potassium EDTA samples from patients with suspected thrombophilia.

Device Story

Invader MTHFR 1298 is an in vitro diagnostic test for detecting the A1298C mutation in the MTHFR gene. Input is purified genomic DNA from human whole blood. The device uses Invader Plus chemistry: a two-phase reaction involving target amplification via thermal cycling followed by isothermal signal generation at 63°C. During signal generation, Cleavase enzyme recognizes overlapping structures formed by probes and target DNA, cleaving 5'-flaps that subsequently trigger FRET cassette cleavage to release fluorescent signals (FAM for wild type, RED for mutant). The assay is performed in 96-well plates using a third-party thermal cycler and fluorometer. Invader Call Reporter software processes raw fluorescence data to determine genotypes. Used in clinical laboratories by trained professionals. Output provides genotype results (Wild Type, Heterozygous, Mutant) to assist clinicians in evaluating patients with suspected thrombophilia.

Clinical Evidence

Bench testing only. Performance validated against bi-directional sequencing. Study of 348 samples showed 100% agreement (347/347 valid results). Precision/reproducibility studies (n=540) across three sites showed 100% agreement. Analytical sensitivity established at 5-80 ng/µL input gDNA. Interference testing confirmed no impact from heparin, cholesterol, bilirubin, hemoglobin, or EDTA. Extraction method equivalency (n=160) and instrument equivalency (n=78) studies demonstrated 100% concordance.

Technological Characteristics

Invader Plus chemistry (PCR amplification + isothermal FRET signal generation). Uses Cleavase enzyme. Form factor: 96-well plate assay. Requires third-party thermal cycler and fluorometer. Software: Java-based, standalone PC. Connectivity: Manual data transfer. Sterilization: Not applicable (reagents).

Indications for Use

Indicated for detection and genotyping of MTHFR gene A1298C mutation in patients with suspected thrombophilia using isolated genomic DNA from whole blood potassium EDTA samples. Prescription use only.

Regulatory Classification

Identification

In vitro diagnostic for the detection and genotyping of a single point mutation of the human 5, 10-methylenetetrahydrofolate reductase gene (MTHFR) in patients with suspected thrombophilia.

Special Controls

*Classification.* Class II (special controls). The special control is FDA's guidance entitled “Class II Special Controls Guidance Document: Factor V Leiden DNA Mutation Detection Systems.” (See § 864.1(d) for the availability of this guidance document.)

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ 1004196 2011 # Invader® MTHFR 1298 510(k) SUMMARY | A. | 510(k) Number: | | | | |----|------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----|-----|--| | | K100496 | APR | 2 5 | | | B. | Purpose for Submission: | | | | | | New Device | | | | | C. | Measurand: | | | | | | MTHFR 1298 | | | | | D. | Type of Test: | | | | | | Qualitative genotyping test for single nucleotide polymorphism detection. | | | | | E. | Applicant: | | | | | | Hologic Inc. | | | | | | Third Wave Technologies | | | | | | 250 Campus Drive | | | | | | Marlborough, MA 01752 | | | | | | 508-263-8912 | | | | | | Contact Person: Randall J. Covill, Manager, Regulatory Affairs | | | | | | Date of Submission: April 2010 | | | | | F. | Proprietary and Established Names: | | | | | | Invader® MTHFR 1298 | | | | | G. | Regulatory Information: | | | | | | 1. Regulation Sections: 21 CFR 864.7280 | | | | | | 2. Classification: | | | | | | Class II | | | | | | 3. Product Code: | | | | | | NPR: Test, MTHFR A1298C Mutations, Genomic DNA PCR | | | | | | 4. Panel: | | | | | | Hematology (81) | | | | | H. | Intended Use: | | | | | | 1. Intended Use(s): | | | | | | The Invader® MTHFR 1298 test is an in vitro diagnostic test intended for the<br>detection and genotyping of a single point mutation (A to C at position 1298) of | | | | the human 5,10-methylenetetrahydrofolate reductase (MTHFR) gene in isolated genomic DNA obtained from whole blood potassium EDTA samples from patients with suspected thrombophilia. - Indication(s) for use: 2. Same as Intended Use - Special Conditions for use statements(s): 3. For prescription use only - 4. Special instrument requirements: None #### I. Device Description: The Invader MTHFR 1298 test consists of the following components: MTHFR 1298 Oligo Mix Universal Buffer Universal Enzyme Mix No DNA Control MTHFR 1298 Wild Type Control MTHFR 1298 Heterozygous Control MTHFR 1298 Mutant Control Invader Call Reporter™ Software Invader® MTHFR 1298 Software {1}------------------------------------------------ ## J. Substantial Equivalence Information: - - 1. Predicate device name(s): , - 2. Predicate 510(k) number(s): - Nanosphere, K070597 - 3. Comparison with predicate: | Table 1: Comparison with Predicate Device | | | |-----------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | | Predicate Device | Proposed Device | | Product Name<br>(Manufacturer,<br>Submission) | Verigene® MTHFR Nucleic Acid<br>Test<br>( <i>Nanosphere, K070597</i> ) | Invader® MTHFR 1298<br>( <i>Hologic, Inc., K100496</i> ) | | Intended Use | "The Verigene MTHFR Nucleic<br>Acid Test is an <i>in vitro</i> diagnostic<br>for the detection and genotyping of<br>a single point mutation (C to T at<br>position 677) of the human 5, 10<br>methylene-tetrahydrofolate<br>reductase gene (MTHFR) in<br>patients with suspected<br>thrombophilia, from isolated<br>genomic DNA obtained from<br>whole blood samples. The test is<br>intended to be used on the<br>Verigene System."<br><br>The Verigene System is a bench-<br>top molecular diagnostic<br>workstation that automates the <i>in<br/>vitro</i> diagnostic analysis and<br>detection of nucleic acids using<br>gold nanoparticle probe<br>technology. The Verigene System<br>is intended to be used by<br>experienced laboratory<br>professionals with training on basic<br>laboratory techniques and on the<br>use of the system components. | The Invader® MTHFR 1298 test is<br>an <i>in vitro</i> diagnostic test intended<br>for the detection and genotyping of a<br>single point mutation (A to C at<br>position 1298) of the human 5,10-<br>methylenetetrahydrofolate reductase<br>(MTHFR) gene in isolated genomic<br>DNA obtained from whole blood<br>potassium EDTA samples from<br>patients with suspected<br>thrombophilia. | | Specimen Type | Purified DNA isolated from human<br>whole peripheral blood | Same as predicate | | Indications for<br>Use | Same as Intended Use | Same as Intended Use | | Target<br>Population | Patients with suspected<br>thrombophilia | Same as predicate | | Chemistry | SNP discrimination via.<br>oligonucleoptide probes; detection<br>via evanescent wave light scatter<br>with nanoparticles. | PCR and Invader® using<br>Fluorescence Resonance Energy<br>Transfer (FRET) chemistry for signal<br>reporting. Same as predicate device.<br>Both our device and predicate device<br>detect signal from amplicons using<br>Fluorescence Resonance Energy<br>Transfer (FRET). | | Hardware | The Verigene System consists of<br>two instruments, the Verigene<br>Processor and the Verigene Reader,<br>and utilizes single-use, disposable<br>Test Cartridges to process and<br>genotype multiple genes in a DNA<br>samples in approximately 1.5<br>hours. | Non-specified, third-party<br>fluorometer and thermal cycler. | | Software<br>Interface | Embedded software in closed<br>system, integrated graphical user<br>interface. | Java-based software installed on a<br>standalone PC capable of converting<br>raw fluorescence data into genotype<br>calls. | | Detection Method | Single-image sensor where<br>nanoparticles are illuminated using<br>a fixed-wavelength light source. | PCR and Fluorescence Resonance<br>Energy Transfer (FRET) chemistry<br>for signal reporting. Same as<br>predicate device. Both our device and<br>predicate device detect signal from<br>amplicons using Fluorescence<br>Resonance Energy Transfer (FRET). | | Sample Size | 25μL | 20ul reaction containing 0.25-4ng/ul<br>gDNA extracted from human<br>peripheral whole blood. | | Detection<br>Procedure | Single-image sensor where<br>nanoparticles are illuminated using<br>a fixed-wavelength light source. | Multi-well fluorometer to detect raw<br>fluorescence. | | Detection<br>Chemistry | SNP discrimination via<br>oligonucleoptide probes; detection<br>via evanescent wave light scatter | PCR and Invader® using<br>Fluorescence Resonance Energy<br>Transfer (FRET) chemistry for signal<br>reporting. Both our device and | | | with nanoparticles. | predicate device detect signal from<br>amplicons using Fluorescence<br>Resonance Energy Transfer (FRET). | | Analysis Time | 90 min. processing with 2 min.<br>analysis time. | ~90 min. amplification followed by 1<br>min signal detection. Software<br>analysis post signal detection. | {2}------------------------------------------------ {3}------------------------------------------------ . : {4}------------------------------------------------ ### K. Standard/Guidance Document Referenced (if applicable); - Guidance for Industry and FDA Staff Class II Special Controls Guidance . Document: Factor V Leiden DNA Mutation Detection Systems issued on March 16, 2004 - Guidance for Industry and FDA Staff Guidance for the Content of . Premarket Submissions for Software Contained in Medical Devices issued May 11, 2005 - Guidance for Industry and FDA Staff Format for Traditional and t Abbreviated 510(k)s issued on August 12, 2005 ### L. Test Principle: The Invader® MTHFR 1298 test utilizes the Invader Plus® chemistry with DNA isolated from human whole blood, for the detection of the targeted sequence polymorphism. Specifically, the Invader Plus® chemistry utilizes a single-tube, two phase reaction, including target amplification and signal generation (mediated by Invader chemistry). Invader Plus® reaction mixes are assembled by combining the MTHFR 1298 Oligo Mix, Universal Enzyme Mix, and Universal Buffer. In a 96-well plate, reaction mix is combined with purified genomic DNA samples, as well as four (4) controls included with the test. The No DNA Control is used by the interpretive software to set the "noise" component of the run for "signal-to-noise" calculations. The genotype-specific controls (WT, HET, MUT) ensure reagents were assembled correctly and perform according to the specifications. The 96-well plate is transferred to an appropriately programmed thermal cycler for target amplification and signal generation. In the target amplification phase of the reaction, amplification is carried out using "two-step" cycling conditions (i.e. denaturation & annealing/extension). Following amplification, Taq polymerase is inactivated by a 10 minute incubation at 99°C, after which the thermal cycler proceeds to 63°C to initiate the signal generation (Invader ) phase of the reaction (see Figure 1). {5}------------------------------------------------ Image /page/5/Figure/0 description: The image shows two diagrams illustrating structure formation, recognition, and cleavage processes. The left diagram, labeled '1a, 1b, 1c,' depicts the process for a wildtype-specific primary probe, while the right diagram, labeled '2a, 2b, 2c,' illustrates the process for a mutation-specific primary probe. Each diagram includes steps for structure formation, structure recognition and cleavage, and a secondary reaction involving FRET cassettes, resulting in fluorescence. The left diagram shows fluorescence 1: FAM, and the right diagram shows fluorescence 2: RED. Figure 1. Invader® Signal Generation Phase During the signal generation phase, a discriminatory Probe transiently hybridizes to the amplified target sequence along with an Invader oligonucleotide, to form an overlapping structure. The 5'-end of the Primary Probe includes a 5'-flap that does not hybridize to the target DNA. The 3'-nucleotide of the bound Invader® oligonucleotide overlaps the Primary Probe, and does not hybridize to the target DNA. The Cleavase enzyme recognizes this overlapping structure and cleaves off the unpaired 51-flap of the Primary Probe, releasing it as a target-specific product. The Primary Probe is designed to have a melting temperature aligned with the Invader® reaction temperature so that under the isothermal reaction conditions (~63°C) the Primary Probes cycle on and off the target DNA. This allows for multiple rounds of Primary Probe cleavage for each DNA target resulting in an accumulation of the number of released 5'-flaps. The released 5'-flap transiently hybridizes with a corresponding FRET cassette forming an overlapping structure that is recognized and the fluorophore is cleaved from the FRET cassette by the Cleavase enzyme. The 5'-flap is designed to have a melting temperature aligned with the Invader reaction temperature, so that the 5 -flaps cycle on and off of the corresponding FRET cassettes. This allows for multiple rounds of FRET cassette cleavage for each 5'flap, and an accumulation of released fluorophore. When the FRET cassette is cleaved, a fluorophore and quencher are separated, generating detectable fluorescence signal. The format uses two different discriminatory Primary Probes, one for the mutant allele and one for the wild type allele (Figure 1). Each Primary Probe is assigned a unique 5'-flap, and distinct FRET cassette, with a spectrally distinct fluorophore. By design, the released 5flaps will bind only to their respective FRET cassettes to generate a target-specific signal, linking the wild type allele with one fluorophore (Fluorescence 1: FAM) and the mutant allele with the second fluorophore (Fluorescence 2: RED). {6}------------------------------------------------ The Invader® MTHFR 1298 software, in combination with Invader Call Reporter™ software, is a data analysis software package developed by Hologic for use with the Invader® MTHFR 1298 test. The software package provides a working template for the setup of reaction mixes and sample placement, and following the import of fluorescence data, it determines results and validity for controls and samples. A summary of the Invader Call Reporter™- Invader® MTHER 1298 package workflow is shown in Figure 2. Image /page/6/Figure/1 description: This image is a flowchart outlining a laboratory assay process. It begins with "Assay Selection," where the operator, run ID, MTHFR 1298, and number of samples are entered. The process continues through "Mix Preparation," "Sample Placement," "Results," and concludes with a "Summary," each step involving data input, result analysis, printing, and saving in various formats like PDF, spreadsheet, and CSV. Figure 2. Invader Call Reporter™- Invader® MTHFR 1298 Package Workflow {7}------------------------------------------------ ### M. Performance Characteristics (if/when applicable): - 1. Analytical performance: - a. Precision/Reproducibility: External Reproducibility (Study #1): Two operators each from three (3) different sites (2 external sites and 1 internal site) performed the testing, in duplicate, over five (5) non-consecutive days for a ten (10) day period using the same testing materials including a panel of nine (9) whole blood samples specific for each of the three (3) possible genotypes (i.e. wild type, heterozygous, homozygous mutant). | Table 2: Inter-laboratory Reproducibility of Invader® 1298 Test | | | | | | | | | | |-----------------------------------------------------------------|----------|-------------------|------------------|------------------------------|----------|------------------|------------------------------|----------|-------------------------------------------------------------------------------------------------------------------------| | Site | Operator | Samples<br>tested | First Pass | | | Final | | | Final %<br>Agreement | | | | | Correct<br>Calls | No Calls<br>(Invalid,<br>EQ) | Miscalls | Correct<br>Calls | No Calls<br>(Invalid,<br>EQ) | Miscalls | <span style="font-size: smaller;">Final Correct Calls</span><br><span style="font-size: smaller;">Samples Tested</span> | | Site<br>001 | 1 | 90 | 90 | 0 | 0 | 90 | 0 | 0 | 100% | | Site<br>001 | 2 | 90 | 90 | 0 | 0 | 90 | 0 | 0 | 100% | | Site<br>002 | 1 | 90 | 90 | 0 | 0 | 90 | 0 | 0 | 100% | | Site<br>002 | 2 | 90 | 90 | 0 | 0 | 90 | 0 | 0 | 100% | | Site<br>003 | 1 | 90 | 90 | 0 | 0 | 90 | 0 | 0 | 100% | | Site<br>003 | 2 | 90 | 90 | 0 | 0 | 90 | 0 | 0 | 100% | | All | All | 540 | 540 | 0 | 0 | 540 | 0 | 0 | 100% | Lot-to-Lot Reproducibility (Study #9): A total of nine (9) genomic DNA samples (three (3) wild type , three (3) heterozygous and three (3) mutants) were tested in quadruplicate using three (3) different kit lots of the Invader® MTHFR 1298 test. The percent agreement between Invader® MTHFR 1298 test and sequencing was 100% (n=108). | Lot | #<br>Samples<br>Tested | First<br>Pass<br>Correct<br>Calls | First<br>Pass No<br>Calls | Miscalls | Final<br>Correct<br>Calls | Final<br>Agreement<br>% | |-------|------------------------|-----------------------------------|---------------------------|----------|---------------------------|-------------------------| | 1 | 36 | 36 | 0 | 0 | 36 | 100 | | 2 | 36 | 36 | 0 | 0 | 36 | 100 | | 3 | 36 | 36 | 0 | 0 | 36 | 100 | | Total | 108 | 108 | 0 | 0 | 108 | 100 | - b. Linearity/assay reportable range: Refer to paragraph D below. - Traceability, Stability, Expected values (controls, calibrators, or methods): C. Real-Time Stability Study #5): Three (3) lots of product in the final configuration are being stored under recommended conditions: (1) -30° to -15°C (Standard Storage of intermediate components) as well as (2) +2° to +8°C (Standard Storage of Genotype-Specific Controls). Functional testing is performed with samples representing all 3 genotypes in quadruplicate at each time point. The interim test results have demonstrated 7 months stability for the device. {8}------------------------------------------------ | Table 4: MTHFR 1298 Genotype Results; Real-time Stability | | | | | | | | | | | |-----------------------------------------------------------|---------------------------------------------------|-----------|-------|-------|-----------|-------|-------|-----------|-------|-------| | Sample/<br>Control | Sequencing/<br>Expected<br>MTHFR 1298<br>Genotype | T₀ Result | | | T₄ Result | | | T₇ Result | | | | | | Lot 1 | Lot 2 | Lot 3 | Lot 1 | Lot 2 | Lot 3 | Lot 1 | Lot 2 | Lot 3 | | Control 1 | WT | WT | WT | WT | WT | WT | WT | WT | WT | WT | | Control 2 | HET | HET | HET | HET | HET | HET | HET | HET | HET | HET | | Control 3 | MUT | MUT | MUT | MUT | MUT | MUT | MUT | MUT | MUT | MUT | | gDNA 1 | WT | WT | WT | WT | WT | WT | WT | WT | WT | WT | | gDNA 2 | WT | WT | WT | WT | WT | WT | WT | WT | WT | WT | | gDNA 3 | HET | HET | HET | HET | HET | HET | HET | HET | HET | HET | | gDNA 4 | MUT | MUT | MUT | MUT | MUT | MUT | MUT | MUT | MUT | MUT | | | Percent Agreement | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | Reagent Freeze-Thaw Stability Study (Study #6): Product in the final configuration was subject to 15 freeze-thaw cycles prior to the final thaw at the time of testing. Functional testing was performed using genomic DNA isolated from cell lines, representing all possible genotypes. The percent agreement between the sequencing result and the Invader® MTHFR 1298 test were 100%, therefore demonstrating stability for up to fifteen (15) freeze/thaw cycles. | Table 5: Freeze/Thaw Stability of Invader MTHFR 1298 | | | | | | | | | | | | | | | | | | |-----------------------------------------------------------------|------------------------------|---|----|---|----|---|---|---|---|----|----|----|----|----|----|-------|-------------| | | Number of Freeze/Thaw Cycles | | | | | | | | | | | | | | | | | | Sample | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | Total | % Agreement | | Control 1<br>(WT) | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 45 | 100 | | Control 2<br>(HET) | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 45 | 100 | | Control 3<br>(MUT) | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 45 | 100 | | gDNA<br>(WT) | 6 | * | 6 | * | 6 | * | * | * | * | 6 | * | 6 | * | * | 6 | 36 | 100 | | gDNA<br>(HET) | 8 | * | 8 | * | 8 | * | * | * | * | 8 | * | 8 | * | * | 8 | 48 | 100 | | gDNA<br>(MUT) | 6 | * | 6 | * | 6 | * | * | * | * | 6 | * | 6 | * | * | 6 | 36 | 100 | | Total | 29 | 9 | 29 | 9 | 29 | 9 | 9 | 9 | 9 | 29 | 9 | 29 | 9 | 9 | 29 | 255 | 100 | | *Testing with gDNA samples did not occur at this testing point. | | | | | | | | | | | | | | | | | | #### Detection limit/Analytical Sensitivity and Normal Range (Study #3): d. Three (3) genomic DNA samples with different genotypes (i.e. WT, HET, MUT) were extracted from whole blood collected in potassium EDTA. Each sample was diluted to eight different concentrations 0.5, 5, 20, 40, 80, 200, 400, 800 ng/ uL and tested in replicates of forty (40). The recommend range of the assay was . . . . {9}------------------------------------------------ determined to be between 5-80 ng/uL of input gDNA, based on 100% concordance of all tested replicates with bi-directional sequencing. | Table 6: Percent Agreement Between Replicates | | | | | | | | | | |-----------------------------------------------|---------------|---------------|--------------|--|--|--|--|--|--| | Sample ID (Genotype based on Sequencing) | | | | | | | | | | | Input Sample<br>Concentration | 03-4720 (MUT) | 03-4525 (HET) | 03-4536 (WT) | | | | | | | | 0.5 ng/µl | 100% (40/40) | 67.5% (27/40) | 100% (40/40) | | | | | | | | 5 ng/µl | 100% (40/40) | 100% (40/40) | 100% (40/40) | | | | | | | | 20 ng/µl | 100% (40/40) | 100% (40/40) | 100% (40/40) | | | | | | | | 40 ng/µl | 100% (40/40) | 100% (40/40) | 100% (40/40) | | | | | | | | 80 ng/µl | 100% (40/40) | 100% (40/40) | 100% (40/40) | | | | | | | | 200 ng/µl | 100% (40/40) | 100% (40/40) | 100% (40/40) | | | | | | | | 400 ng/µl | 100% (40/40) | 100% (40/40) | 100% (40/40) | | | | | | | | 800 ng/µl | 100% (40/40) | 100% (40/40) | 100% (40/40) | | | | | | | Analytical specificity (Interfering Substances) (Study #4): e. Test performance was not affected by addition of the following substances to nine (9) whole blood samples of different genotype (3 WT, 3 HET, 3 MUT) prior to extraction: - Heparin (1500 U/dL human whole blood) . - . Cholesterol (300 mg/dL human whole blood) - . Bilirubin (10 mg/dL human whole blood) - Hemoglobin (up to 0.2% in whole blood) . - Potassium EDTA (1.8 mg/mL human whole blood) . - Ethanol-based Wash Buffer (5% in DNA sample) . {10}------------------------------------------------ | Table 7: Summary, Comparison of Invader® MTHFR 1298 Interfering Substance Results<br>to Sequencing | | | | | | | | | |----------------------------------------------------------------------------------------------------|-------------------------------------------------------|-----------------------------------------------|----------------------------------------------------------------------------------|----------------|--|--|--|--| | Interfering<br>Substance<br>Code | Substance Concentration /<br>(in blood or DNA sample) | % Agreement<br>with<br>Sequencing<br>Genotype | % Agreement<br>with<br>Untreated<br>Sample<br>Invader®<br>MTHFR 1298<br>Genotype | PASS /<br>FAIL | | | | | | A | No Addition Control<br>(Untreated) | 100% (18 of 18) | N/A | PASS | | | | | | B | Bilirubin 10mg/dl (blood) | 100% (18 of 18) | 100% (18 of 18) | PASS | | | | | | C | Cholesterol 300mg/dl (blood) | 100% (18 of 18) | 100% (18 of 18) | PASS | | | | | | D | K2EDTA 1.8mg/ml (blood) | 100% (18 of 18) | 100% (18 of 18) | PASS | | | | | | E | Heparin 1500 U/dl (blood) | 100% (18 of 18) | 100% (18 of 18) | PASS | | | | | | F1 | Hemoglobin 0.2% (blood) | 100% (18 of 18) | 100% (18 of 18) | PASS | | | | | | F2 | Hemoglobin 0.1% (blood) | 100% (18 of 18) | 100% (18 of 18) | PASS | | | | | | F3 | Hemoglobin 0.05% (blood) | 100% (18 of 18) | 100% (18 of 18) | PASS | | | | | | F4 | Hemoglobin 0.025% (blood) | 100% (18 of 18) | 100% (18 of 18) | PASS | | | | | | G | Buffer AW2 5% (DNA) | 100% (18 of 18) | 100% (18 of 18) | PASS | | | | | - f. Pre-Analytical Equivalency Study/Genomic DNA Extraction Reproducibility (Study #7): Thirty (30) human whole blood samples and ten (10) leukocyte depleted whole blood spiked with cell lines were divided and extracted using four (4), commercially available DNA extraction methods (A. Qiagen QlAamp® 96 DNA Blood Kit, B. Qiagen QIAamp® DNA Blood Mini Kit, C. Gentra Generation® Capture Column Kit (Qiagen), D. Roche MagNA Pure LC DNA Isolation Kit I). The 160 extracted DNAs were analyzed in singlicate with one (1) lot of the device. The percent agreement between the Invader® MTHFR 1298 test for each extraction method and bi-directional sequencing was 100% (n=40). {11}------------------------------------------------ | Extraction<br>Method | #<br>Samples<br>Tested | First<br>Pass<br>Correct<br>Calls | First<br>Pass<br>No<br>Calls | Miscalls | Final<br>Correct<br>Calls | Final<br>Agreement<br>% | |---------------------------------------------------------------------------------------------|------------------------|-----------------------------------|------------------------------|----------|---------------------------|-------------------------| | A | 40 | 40 | 0 | 0 | 40 | 100 | | B | 40 | 39 | 1* | 0 | 39* | 100* | | C | 40 | 40 | 0 | 0 | 40 | 100 | | D | 40 | 40 | 0 | 0 | 40 | 100 | | Total | 160 | 159 | 1 | 0 | 159 | 100 | | *Sample was removed from study due to loss of traceability of the sample<br>identification. | | | | | | | - Instrument Equivalency (Study #8): Twenty-nine (29) human whole blood ള. samples and ten (10) leukocyte depleted whole blood samples spiked with cell lines were extracted using two (2) commonly used extraction methods. The extracts were tested with the Invader® MTHFR 1298 test using three (3) commercially available thermal cyclers (1. ABI GeneAmp® PCR System 9700 with 96-well gold block, 2. ABI Veriti™ and 3. MJ Research PTC-100) and the raw fluorescent data acquired on three (3) commercially available fluorometers (A. Tecan Infinite®, B. Tecan Genios® and C. BioTek®, FLx800). Results from the three (3) fluorometers were transferred into the interpretive software and genotype calls compared to bi-directional sequencing. | Table 9: Concordance by Instrument | | | | |------------------------------------|-----------------|-----------------|-----------------| | | Thermal Cycler | | | | Fluorometer | 1 | 2 | 3 | | A | 78 of 78 = 100% | 78 of 78 = 100% | 78 of 78 = 100% | | B | 78 of 78 = 100% | 78 of 78 = 100% | 78 of 78 = 100% | | C | 78 of 78 = 100% | 78 of 78 = 100% | 78 of 78 = 100% | Comparison studies: 2. > Method comparison: Bi-directional Sequencing (Study #2): a. > > Human whole blood samples (n = 348) underwent DNA extraction and subsequent bi-directional DNA sequence analysis. The same DNA samples were then analyzed using the Invader® MTHFR 1298 test. The observed agreement between the Invader® MIHFR 1298 test and bidirectional DNA sequencing was 100% (347/347). The first run agreement with bi-directional sequencing was 99.71% (347/348). {12}------------------------------------------------ | Table 10: Agreement between the Invader® MTHFR 1298 Test and<br>Bi-directional DNA Sequencing | | | | | |-----------------------------------------------------------------------------------------------|------------------|---------------------------------------------|-----------------------------------------------------------|------------------------| | MTHFR<br>1298<br>Genotype* | Number<br>tested | Number of<br>Valid<br>Results on<br>1st Run | Number of<br>Correct<br>genotype<br>calls on<br>First Run | First Run<br>Agreement | | Homozygous<br>Wild Type<br>(GG) | 183 | 182** | 182** | 99.45% | | Heterozygous<br>(GA) | 125 | 125 | 125 | 100% | | Homozygous<br>Mutant<br>(AA) | 40 | 40 | 40 | 100% | | Total | 348 | 347** | 347** | 99.71% | * Genotype determined through bi-directional DNA sequencing ** One sample failed to generate valid results. This sample was reported as invalid (EQ) and no genotype call was assigned by the interpretive software. The EQ result was used to determine the First Run Agreement. - 3. External Reproducibility studies: - Clinical Sensitivity: please refer to section 1d above. a. - Clinical specificity: please refer to section 1e above. b. - Expected values/Reference range: (Prevalence) 4. MTHFR A1298C: ~33% ### N. System Descriptions: - 1. Modes of Operation: - Closed System 2. Software: FDA has reviewed applicant's Hazard Analysis and software development processes for this line of product type. Yes X - 3. Specimen Identification: Manual Labeling - 4. Specimen Sampling and Handling: DNA should be extracted using a validated DNA extraction method that generates DNA concentration range of greater than 5ng/ul. - 5. Quality Control: Each test contains positive and negative controls to assure proper functioning of the system: Failure of any controls will be indicated as "Invalid" in the test results section of the report. The genotyping test result will not be reported for any sample for which a positive or negative control failure occurs. Positive Control: The genotype controls (WT, HET, MUT) ensure reagents were assembled correctly and perform according to the specifications. Negative Control: The No DNA Control is used by the interpretive software to set the "noise" component of the run for "signal-to-noise" calculations. Hardware and Software Controls: {13}------------------------------------------------ The genotyping test result will not be reported for any sample for which a positive or negative control failure occurs. ' ## O. Proposed Labeling: The labeling is sufficient and satisfies the requirements of 21 CFR Part 809.10. # P. Conclusion: The submitted information in this 510 (k) notification is complete and supports a substantial equivalence decision. {14}------------------------------------------------ # DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/14/Picture/1 description: The image shows the seal of the Department of Health & Human Services - USA. The seal features a stylized eagle with its wings spread, facing to the right. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" are arranged in a circular pattern around the eagle. The seal is black and white. Food and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 Hologic Inc. Third Wave Technologies c/o Mr. Randall J. Covill Senior Specialist Regulatory Affairs 502 South Rosa Road Madison, WI 53719 APR 2 5 2011 Re: k100496 Trade/Device Name: Regulation Number: Regulation Name: Regulatory Class: Product Code: Dated: March 31, 2011 Received: April 7, 2011 Invader® MTHFR 1298 21 CFR §864.7280 Factor V Leiden DNA Mutation Detection Systems Class II OMM Dear Mr. Covill: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into class II (Special Controls), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter {15}------------------------------------------------ Page 2 – Mr. Randall J. Covill will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, ia m Chan Maria M. Chan, Ph.D Director Division of Immunology and Hematology Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health Enclosure {16}------------------------------------------------ # Indication for Use Statement 510(k) Number (if known): k100496 . Invader MTHFR 1298 test Device Name: Indication for Use: The Invader® MTHFR 1298 test is an in vitro diagnostic test intended for the detection and genotyping of a single point mutation (A to C at position 1298) of the human 5,10methylenetetrahydrofolate reductase (MTHFR) gene in isolated genomic DNA obtained from whole blood potassium EDTA samples from patients with suspected thrombophilia. Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD) Mana m Chan --- **Division Sign-Off** **Division Sign-Off** Office of In Vitro Diagnostic Device Evaluation and Safety 510(k) K100496