(162 days)
THE IMPLANT(S) IS DESIGNED FOR USE IN THE EDENTULOUS SITES IN THE MANDIBLE OR MAXILLA FOR SUPPORT OF A COMPLETE DENTURE PROSTHESIS, A TERMINAL OR INTERMEDIATE ABUTMENT FOR FIXED OR PARTIAL DENTURES, OR A SINGLE TOOTH REPLACEMENT. THE 8,25MM LONG IMPLANT CAN NOT BE USED AS A SINGLE TOOTH REPLACEMENT.
Not Found
The provided document is an FDA 510(k) clearance letter for a dental implant. It states that the device is substantially equivalent to legally marketed predicate devices and therefore does not require a premarket approval application (PMA).
However, this document *does not contain any information regarding:
- Acceptance criteria and reported device performance (in terms of specific metrics like sensitivity, specificity, accuracy)
- Details of any specific study (clinical or analytical) that would prove the device meets acceptance criteria.
- Sample sizes used for test sets or training sets.
- Data provenance, number or qualifications of experts, adjudication methods, multi-reader multi-case studies, standalone performance, or types of ground truth.
This document is a regulatory clearance and not a study report. It confirms that the device can be legally marketed based on its equivalence to existing products, but it does not provide the technical performance data that would typically be found in a study proving acceptance criteria.
Therefore, I cannot fulfill your request for a table of acceptance criteria and reported device performance, nor the other requested details about a study, because this information is not present in the provided text.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo for the Department of Health & Human Services - USA. The logo consists of a stylized eagle with three lines representing its wings and two lines representing its legs. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
Grundy Advanced Biomedical Systems LLC C/O Mr. William Simmons Vice President Technical Support 832 Marseilles - Galion RDW Marion, Ohio 43302
IJUL 2 8 2010
Re: K100411
Trade/Device Name: Bioesthetic Dental Implant 4,2 - 3,5 Series Regulation Number: 21 CFR 872.3640 Regulation Name: Endosseous Dental Implant Regulatory Class: II Product Code: DZE Dated: July 20, 2010 Received: July 23, 2010
Dear Mr. William Simmons:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA). it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition. FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Page 2- Mr. Simmons
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to
http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours.
f
ally a
Anthony D. Watson, B.S., M.S., M.B.A. Director
Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
INDICATIONS FOR USE
510(K) NUMBER(IF KNOWN): K100411
DEVICE NAME: BIOESTHETIC DENTAL IMPLANT 4,2-3,5 SERIES
INDICATIONS FOR USE:
THE IMPLANT(S) IS DESIGNED FOR USE IN THE EDENTULOUS SITES IN THE MANDIBLE OR MAXILLA FOR SUPPORT OF A COMPLETE DENTURE PROSTHESIS, A TERMINAL OR INTERMEDIATE ABUTMENT FOR FIXED OR PARTIAL DENTURES, OR A SINGLE TOOTH REPLACEMENT. THE 8,25MM LONG IMPLANT CAN NOT BE USED AS A SINGLE TOOTH REPLACEMENT.
AND/OR PRESCRIPTION USE X (PART21 CFR 801 SUBPART D)
OVER-THE-COUNTERUSE (21 CFR 801 SUBPART C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
CONCURRENCE OF CDRH, OFFICE OF DEVICE EVALUATION(ODE)
Kevin Mulby for MSR
(Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices GE1 OF 1
510(k) Number: K100411
§ 872.3640 Endosseous dental implant.
(a)
Identification. An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.(b)
Classification. (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2)
Classification. Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use;
(ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads;
(iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system;
(iv) The device must be demonstrated to be biocompatible;
(v) Sterility testing must demonstrate the sterility of the device;
(vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment;
(vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians;
(viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and
(ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.