K Number
K091239

Validate with FDA (Live)

Manufacturer
Date Cleared
2009-09-22

(148 days)

Product Code
Regulation Number
872.3640
Panel
Dental
Age Range
All
Reference & Predicate Devices
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

Astra Tech Implant System is intended to be used to replace missing masticatory functional units (teeth) in single or multiple unit applications within the mandible or maxilla. The device may be used equally well in a single-stage or two-stage surgical procedure. It is indicated for immediate implantation in extraction sites or implantation in partially healed or completely healed alveolar ridge situations. When a one-stage surgical approach is applied, the implant may be immediately loaded when good primary stability is achieved and the functional load is appropriate. The OsseoSpeed Narrow product line shall be used only to replace maxillary lateral incisors and mandibular lateral and central incisors.

The fluoride-modified implant surface, though having a fluoride ion level far below that needed for caries prevention in teeth, provides a favorable substrate for bone attachment and osseointegration. Astra Tech Implant System is especially indicated for use in soft bone applications where implants with other implant surface treatments may be less effective. Because initial stability may be difficult to obtain in Type IV bone, immediate loading of single tooth restorations may not be appropriate in such situations. Immediate loading of single tooth restorations is not recommended for the OsseoSpeed™ 4.0S - 6 mm implant.

Device Description

Astra Tech Implant System implants, abutments, prosthetic components and accessories are intended for supporting prosthetic devices in edentulous or partially edentulous patients to restore esthetics and chewing function. All components of the Astra Tech Implant System are identical to those presently marketed. The purpose of this submission is to expand device claims.

AI/ML Overview

This 510(k) summary for the Astra Tech Implant System (K091239) does not contain information on acceptance criteria or a study proving device performance against such criteria.

The document is a standard 510(k) submission summary, which focuses on demonstrating substantial equivalence to a predicate device. It defines the intended use and describes the device, but does not present specific performance metrics, clinical study data, or acceptance criteria that would typically be found in a study proving device performance.

Therefore, I cannot populate the table or answer the specific questions about sample sizes, ground truth establishment, expert qualifications, or MRMC studies, as that information is not present in the provided text.

The document states: "Astra Tech AB demonstrated that, for the purposes of FDA's regulation of medical devices, the Astra Tech Implant System is substantially equivalent in indications and design principles to predicate devices..." This implies that the 'study' conducted was a comparison to existing, legally marketed devices, rather than a de novo clinical trial with defined acceptance criteria and performance metrics. Substantial equivalence does not require new performance data if the new device is sufficiently similar to a predicate.

{0}------------------------------------------------

510(k) Summary

1

:

K091239

Astra Tech Implant System

510(k) Summary

SEP 2 2 2009

Astra Tech AB Astra Tech Implant System

Astra Tech AB

Christina Lewing

ADMINISTRATIVE INFORMATION

Manufacturer Name:

Aminogatan 1, P.O. Box 14 Mölndal, Sweden SE-431-21 Telephone: +46 31 776 30 00 +46 31 776 30 10 Fax:

Official Contact:

Representative/Consultant:

Linda K. Schulz Floyd G. Larson PaxMed International, LLC 11234 El Camino Real, Suite 200 San Diego, CA 92130 Telephone: +1 (858) 792-1235 +1 (858) 792-1236 Fax: email: Ischulz@paxmed.com

flarson@paxmed.com

DEVICE NAME AND CLASSIFICATION

Trade/Proprietary Name: Common Name: Classification Regulations:

Product Code: Classification Panel: Reviewing Branch:

Astra Tech Implant System Dental implant, dental implant abutment Implant, endosseous, root form Endosseous dental implant abutment Class II, 21 CFR 872.3640 DZE Dental Products Panel Dental Devices Branch

INTENDED USE

Astra Tech Implant System is intended to be used to replace missing masticatory functional units (teeth) in single or multiple unit applications within the mandible or maxilla. The device may be used equally well in a single-stage or two-stage surgical procedure. It is indicated for immediate implantation in extraction sites or implantation in partially healed or completely healed alveolar ridge situations. When a one-stage surgical approach is applied, the implant may be immediately loaded when good primary stability is achieved and the functional load is appropriate. The OsseoSpeed Narrow product line shall be used only to replace maxillary lateral incisors and mandibular lateral and central incisors.

{1}------------------------------------------------

The fluoride-modified implant surface, though having a fluoride ion level far below that needed for caries prevention in teeth, provides a favorable substrate for bone attachment and osseointegration. Astra Tech Implant System is especially indicated for use in soft bone applications where implants with other implant surface treatments may be less effective. Because initial stability may be difficult to obtain in Type IV bone, immediate loading of single tooth restorations may not be appropriate in such situations. Immediate loading of single tooth restorations is not recommended for the OsseoSpeed™ 4.0S - 6 mm implant.

DEVICE DESCRIPTION

Astra Tech Implant System implants, abutments, prosthetic components and accessories are intended for supporting prosthetic devices in edentulous or partially edentulous patients to restore esthetics and chewing function. All components of the Astra Tech Implant System are identical to those presently marketed. The purpose of this submission is to expand device claims.

EQUIVALENCE TO MARKETED DEVICE

Astra Tech AB demonstrated that, for the purposes of FDA's regulation of medical devices, the Astra Tech Implant System is substantially equivalent in indications and design principles to predicate devices, each of which has been determined by FDA to be substantially equivalent to pre-amendment devices.

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three stripes extending from its wing. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" is arranged in a circular pattern around the eagle.

SEP 2 2 2009

Food and Drug Adminismation 10903 New Hampshire Avenne Document Mail Center - WO66-G609 Silver Spring, MD 20993-0002

Astra Tech AB C/O Ms. Linda K. Schulz Regulatory Affairs Pax Med International, LLC 11234 El Camino Real, Suite 200 San Diego, California 92130

K091239 Re:

Trade/Device Name: Astra Tech Implant System Regulation Number: 21 CFR 872.3640 Regulation Name: Endosseous Dental Implant Regulatory Class: II Product Code: DZE Dated: September 17, 2009 Received: September 18, 2009

Dear Ms. Schulz:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{3}------------------------------------------------

Page 2- Ms. Schulz

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/ CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely yours,

Arthur D. Little

Susan Runner, D.D.S., M.A. Acting Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

Indications for Use

510(k) Number (if known):

Device Name: Astra Tech Implant System

Indications for Use:

Astra Tech Implant System is intended to be used to replace missing masticatory functional units (teeth) in single or multiple unit applications within the mandible or maxilla. The device may be used equally well in a single-stage or two-stage surgical procedure. It is indicated for immediate implantation in extraction sites or implantation in partially healed or completely healed alveolar ridge situations. When a one-stage surgical approach is applied, the implant may be immediately loaded when good primary stability is achieved and the functional load is appropriate. The OsseoSpeed Narrow product line shall be used only to replace maxillary lateral incisors and mandibular lateral and central incisors.

The fluoride-modified implant surface, though having a fluoride ion level far below that needed for caries prevention in teeth, provides a favorable substrate for bone attachment and osseointegration. Astra Tech Implant System is especially indicated for use in soft bone applications where implants with other implant surface treatments may be less effective. Because initial stability may be difficult to obtain in Type IV bone; immediate loading of single tooth restorations may not be appropriate in such situations. Immediate loading of single tooth restorations is not recommended for the OsseoSpeed™ 4.0S - 6 mm implant.

Prescription Use X (Part 21 CFR 801 Subpart D)

Over-The-Counter Use AND/OR (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Kein Marly for MSR
(Division Sign-Off)

Page 1 of

Division of Anesthesiology, General Hospital Infection Control, Dental Devices

510(k) Number: K091239

§ 872.3640 Endosseous dental implant.

(a)
Identification. An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.(b)
Classification. (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2)
Classification. Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use;
(ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads;
(iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system;
(iv) The device must be demonstrated to be biocompatible;
(v) Sterility testing must demonstrate the sterility of the device;
(vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment;
(vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians;
(viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and
(ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.