FLUCONAZOLE 25UG BBL SENSI-DISC

K082271 · Becton, Dickinson & CO · JTN · Oct 6, 2008 · Microbiology

Device Facts

Record IDK082271
Device NameFLUCONAZOLE 25UG BBL SENSI-DISC
ApplicantBecton, Dickinson & CO
Product CodeJTN · Microbiology
Decision DateOct 6, 2008
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 866.1620
Device ClassClass 2

Intended Use

Antimicrobial Susceptibility Test Disks are used for semi-quantitative in vitro susceptibility testing by standardized agar diffusion test procedures. Fluconazole 25 ug BBL " Sensi-Disc" is intended for use in determining the susceptibility to Fluconazole of a wide range of pathogens. as described in the "Indications for Use" section. Zone sizes used for interpretation of tests. including control organism limits, were determined by the antimicrobic manufacturer and received FDA approval under NDA Number 19-949.

Device Story

Device consists of high-quality paper disks impregnated with 25µg of Fluconazole. Used in clinical laboratories for in vitro agar diffusion susceptibility testing. Disks are applied to Mueller Hinton Agar plates inoculated with pure cultures of clinical isolates. Following incubation, zones of inhibition surrounding disks are measured. Zone diameters are compared to established standards to determine susceptibility categories (e.g., susceptible, intermediate, resistant). Results assist healthcare providers in selecting appropriate antimicrobial therapy for patients with Candida infections.

Clinical Evidence

No clinical data provided. Substantial equivalence is based on established agar diffusion methodology and performance characteristics defined in the FDA-approved drug package insert for Fluconazole.

Technological Characteristics

High-quality paper disks impregnated with 25µg Fluconazole. Principle: Agar diffusion (Bauer-Kirby method). Test medium: Mueller Hinton Agar. Manual measurement of zone diameters. No electronic or software components.

Indications for Use

Indicated for in vitro agar diffusion susceptibility testing to determine pathogen susceptibility to Fluconazole. Active against Candida species including C. albicans, C. glabrata, C. parapsilosis, C. tropicalis, C. dubliniensis, C. guilliermondii, C. kefyr, and C. lusitaniae.

Regulatory Classification

Identification

An antimicrobial susceptibility test disc is a device that consists of antimicrobic-impregnated paper discs used to measure by a disc-agar diffusion technique or a disc-broth elution technique the in vitro susceptibility of most clinically important bacterial pathogens to antimicrobial agents. In the disc-agar diffusion technique, bacterial susceptibility is ascertained by directly measuring the magnitude of a zone of bacterial inhibition around the disc on an agar surface. The disc-broth elution technique is associated with an automated rapid susceptibility test system and employs a fluid medium in which susceptibility is ascertained by photometrically measuring changes in bacterial growth resulting when antimicrobial material is eluted from the disc into the fluid medium. Test results are used to determine the antimicrobial agent of choice in the treatment of bacterial diseases.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ | 510(k) Submission | |-------------------| |-------------------| | OCT 0 6 2008 | | |------------------------|-----------------------------------------------------------------------------------------------------------------------| | | 510(k) SUMMARY | | SUBMITTED BY: | Becton, Dickinson and Company<br>7 Loveton Circle<br>Sparks, MD 21152<br>Phone 410-316-4938<br>Fax: 410-316-4499 | | CONTACT NAME: | Janine Matlak, Regulatory Affairs Specialist | | DATE PREPARED: | August 8, 2008 | | DEVICE TRADE NAME: | Fluconazole 25µg, BBL <sup>™</sup> Sensi-Disc <sup>™</sup> Antimicrobial<br>Susceptibility Test Disks | | DEVICE COMMON NAME: | Antimicrobial Susceptibility Test Disks | | DEVICE CLASSIFICATION: | 21 CFR §866.1620, Class II (Product Code JTN), Susceptibility<br>Test Disks, Antimicrobial | | PREDICATE DEVICE: | Other BBL <sup>™</sup> Sensi-Disc <sup>™</sup><br>(eg, Ciprofloxacin 5 µg, BBL <sup>™</sup> Sensi-Disc <sup>™</sup> ) | ## INTENDED USE: Antimicrobial Susceptibility Test Disks are used for semi-quantitative in vitro susceptibility testing by standardized agar diffusion test procedures. Fluconazole 25 ug BBL " Sensi-Disc" is intended for use in determining the susceptibility to Fluconazole of a wide range of pathogens. as described in the "Indications for Use" section. Zone sizes used for interpretation of tests. including control organism limits, were determined by the antimicrobic manufacturer and received FDA approval under NDA Number 19-949. {1}------------------------------------------------ ## 510(k) SUMMARY ### Indications for Use: Use of Fluconazole 25ug, BBL" Sensi-Disc" for in vitro agar diffusion susceptibility testing is indicated when there is a need to determine the susceptibility of pathogens to Fluconazole. The concentration of 25 ug has been shown to be active in vitro against most strains of Candida species listed below. as described in the FDA approved drug insert for this agent. # Active In Vitro and in Clinical Infections Against: Candida albicans Candida glabrata (Many strains are intermediately susceptible) Candida parapsilosis Candida tropicalis ## Active In Vitro Against: Candida dubliniensis Candida guilliermondii Candiaa kefyr Candida lusitaniae {2}------------------------------------------------ ## DEVICE DESCRIPTION: Fluconazole 25μg BBL™ Sensi-Disc™ is prepared by impregnating high quality paper with accurately Fluconazole 25pg BBB - SchsFDBS - 15 prepared of the drug manufacturer. Each Fluconazole disk is clearly decellinied aniounts of I noomazone supplied of content. Fluconazole cartridges each contain 50 impregnated disks that are packed as either a single cartridge in a single box. or in a package comaining minoregnated uisks that are packed as entrely surettings in virro susceptibility evaluations by the agar diffusion test method. Agar diffusion susceptibility methods employing dried filter paper disks impregnated with specific concentrations of antimicrobial agents were developed in the 1940s. In order to eliminate of minimize variability in the testing. Bauer et al. developed a standardized procedure in which Mueller Hinton Agar was selected as the test medium. Was serected as the test medial. Various regulatory agencies and standards-writing organizations subsequently published standardized reference procedures based on the Bauer-Kirby method. Among the earliest and most widely accepted of There standardized procedures were those published by the U.S. Food and Drug Administration (FDA) these standatured procedures wore these parties was adopted as a consensus standard by the and the World Treantir Organization (CLSI) [Formerly National Committee for Clinical Laboratory Standards (NCCLS)] and is periodically updated. ## DEVICE PRINCIPLE: Disks containing a wide variety of selected agents are applied to the surface of Mueller Hinton Agar plates, supplemented as needed and inoculated with pure cultures of clinical isolates. Following plates, suppremented and the zones of inhibition surrounding the disks are measured and modoanon, the putes are chaintive and nes for individual agents in order to determine the agent(s) most suitable for use in therapy. The categorible (S), susceptible (S), susceptible-dose dependent (S-Sundore for ass in the arganism being tested is made by comparing zone diameters to those found in the approved pharmaceutical package insert. {3}------------------------------------------------ ## DEVICE COMPARISON: The BBL™ Sensi-Disc™ Antimicrobial Susceptibility Test Disks – Fluconazole 25µg is similar to the BBL " Sensi-Disc" Antimicrobial Susceptibility Test Disks - Ciprofloxacin 5 ug in that: - Both methods are for susceptibility testing using paper disks impregnated with an agent. � - Both methods are intended to test susceptibility to pathogenic isolates. . - Both methods provide the user with minimum inhibitory concentration (MIC) results based on . measurements of zone diameters. - measurements of 2016 thansers. In determine categorical interpretations using the measured zone ◆ diameters against CLSI Approved Standards. - Both methods use pure cultures of isolates. . The BBL™ Sensi-Disc™ Antimicrobial Susceptibility Test Disks - Fluconazole 25ug differs from the BBL " Sensi-Disc" Antimicrobial Susceptibility Test Disks - Ciprofloxacin 5 µg in that: - BBL™ Sensi-Disc™ Antimicrobial Susceptibility Test Disks Fluconazole 25µg is a susceptibility test t DDE " Suisi Dise" imminieroous Daospation of 25ug while the BBL." Sensi-Disc Antimicrobial Susceptibility Test Disks - Ciprofloxacin 5 µg is a susceptibility test that uses disks impregnated with Ciprofloxacin at a concentration of 5 ug. - BBL" Sensi-Disc" Antimicrobial Susceptibility Test Disk Flucomazole 25 µg is a susceptibility test . DDL " Sensi-Disc " Innimbrobla: Susceptian the BBL " Sensi-Disc"" Antimicrobial Susceptibility Test Disk - Ciprofloxacin 5 µg. ## SUBSTANTIAL EQUIVALENCE TESTING DATA: See the Fluconazole drug package insert, "Susceptibility Testing Methods: Diffusion Techniques" (Appendix 1). {4}------------------------------------------------ Image /page/4/Picture/1 description: The image shows the logo for the Department of Health and Human Services (HHS) in the USA. The logo features a stylized depiction of an eagle or bird-like figure with outstretched wings. The text "DEPARTMENT OF HEALTH AND HUMAN SERVICES USA" is arranged in a circular pattern around the bird. The logo is black and white. Food and Drug Administration 2098 Gaither Road Rockville MD 20850 OCT 0 6 2008 Ms. Janine Matlak Regulatory Affairs Specialist BD Diagnostics Systems Becton, Dickinson and Company 7 Loveton Circle Sparks, MD 21152 k082271 Re: > Trade/Device Name: BBLTM Sensi-Disc™ Antimicrobial Susceptibility Disks. Fluconazole 25 µg Regulation Number: 21 CFR 866.1620 Regulation Name: Antimicrobial Susceptibility Test Disc Regulatory Class: Class II Product Code: JTN Dated: August 8, 2008 Received: August 11, 2008 Dear Ms. Matlak: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). {5}------------------------------------------------ Page 2 - This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific information about the application of labeling requirements to your device, or questions on the promotion and advertising of your device, please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (240)276-0484. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97), You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html Sincerely yours, Sales, a Form Sally A. Hojvat, M.Sc., Ph.D. Director Division of Microbiology Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health Enclosure {6}------------------------------------------------ #### INDICATIONS FOR USE 510(k) Number (if known): KOG2271 Device Name: BBL™ Sensi-Disc™ Antimicrobial Susceptibility Test Disks, Fluconazole25ug #### Indications for Use: Use of Fluconazole 25μg, BBL™ Sensi-Disc™ for in vitro agar diffusion susceptibility testing is indicated when there is a need to determine the susceptibility of pathogens to Fluconazole. The concentration of 25 ug has been shown to be active in vitro against most strains of Candida species listed below, as described in the FDA approved drug insert for this agent. #### Active In Vitro and in Clinical Infections Against: Candida albicans Candida glabrata (Many strains are intermediately susceptible) Candida parapsilosis Candida tropicalis ### Active In Vitro Against: Candida dubliniensis Candida guilliermondii Canaida kefvi Candida lusitaniae Prescription Use ブ (Per 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________ (Per 21 CFR 801 Subpart C) # (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD) Freddie Lee Poole Division Sign Off Division Sign-Off Office of In Vitro Diagnostic Device Evaluation and Safety s10(k) K682271