K Number
K081900

Validate with FDA (Live)

Manufacturer
Date Cleared
2008-10-24

(113 days)

Product Code
Regulation Number
872.3640
Panel
Dental
Reference & Predicate Devices
N/A
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The Transitional Tooth Replacement is intended to be used as a temporary restorative application for placement in the bone of the upper arch. The purpose is to provide support for temporary, fixed cosmetic provisional restorations. The implant is intended for patients with congenitally missing teeth, primarily the Upper Lateral Incisors.

Device Description

The Temporary Tooth Replacement is comprised of dental implant screws and prosthetic components. The system is designed to be used as a temporary restorative application for placement in the bone of the upper arch. The purpose is to provide support for temporary, fixed cosmetic provisional restorations. The implant is intended for patients with congenitally missing teeth, primarily the Upper Lateral Incisors. The system will consist of a screw and a molded pontic tooth that would be secured to the head of the screw using adhesive. The implant screw is removed once the patient reaches maturity and a permanent implant can be placed.

AI/ML Overview

This document is a 510(k) summary for a medical device called "Temporary Tooth Replacement (TTR)". It describes the device, its intended use, and claims substantial equivalence to a predicate device, the Dentatus Monorail Transitional Implant (MTI).

However, this document does not contain any information regarding acceptance criteria or a study that proves the device meets specific acceptance criteria. It is a regulatory submission focused on demonstrating substantial equivalence to an already marketed device, which generally relies on comparing design, materials, and intended use rather than presenting new performance data against pre-defined criteria.

Therefore, I cannot provide the requested information about acceptance criteria and device performance based on the provided text.

Here is a breakdown of why the requested information cannot be extracted:

  1. A table of acceptance criteria and the reported device performance: This document explicitly states it is claiming "Substantial Equivalence" to another legally marketed device. This regulatory pathway typically involves demonstrating that the new device is as safe and effective as a predicate device, often by showing it performs similarly. It does not usually require the establishment and reporting of new, specific acceptance criteria and the results of a study designed to meet those.
  2. Sample size used for the test set and the data provenance: No test data or studies are mentioned.
  3. Number of experts used to establish the ground truth... and qualifications: Not applicable as no ground truth establishment is described.
  4. Adjudication method: Not applicable.
  5. Multi reader multi case (MRMC) comparative effectiveness study: Not applicable.
  6. Standalone performance study: Not applicable.
  7. Type of ground truth used: Not applicable.
  8. Sample size for the training set: This document is about a physical medical device (dental implant), not an AI/ML algorithm. Therefore, "training set" is not relevant here.
  9. How the ground truth for the training set was established: Not applicable.

In summary, the provided document is a 510(k) premarket notification for a traditional medical device, not an AI/ML device, and it focuses on substantial equivalence rather than presenting new performance data against acceptance criteria.

{0}------------------------------------------------

K081900 sds

SYBRON DENTAL SPECIALTIES

OCT 2 4 2008

Section III - 510(k) Summary of Safety and Effectiveness

Submitter:

Sybron Dental Specialties, Inc. 1717 W. Collins Avenue Orange, California 92867 (714) 516-7602 - Phone (714) 516-7488 - Facsimile Wendy Garman - Contact Person

Date Summary Prepared: July 2008

Device Name:

  • Trade Name Temporary Tooth Replacement (TTR) .
  • . Common Name - Temporary Endosseous Dental Implant
  • . Classification Name - Implant, Endosseous Dental, per 21 CFR § 872.3640

Devices for Which Substantial Equivalence is Claimed:

  • . Dentatus, Monorail Transitional Implant (MTI)

Device Description:

The Temporary Tooth Replacement is comprised of dental implant screws and prosthetic components. The system is designed to be used as a temporary restorative application for placement in the bone of the upper arch. The purpose is to provide support for temporary, fixed cosmetic provisional restorations. The implant is intended for patients with congenitally missing teeth, primarily the Upper Lateral Incisors. The system will consist of a screw and a molded pontic tooth that would be secured to the head of the screw using adhesive. The implant screw is removed once the patient reaches maturity and a permanent implant can be placed.

Intended Use of the Device:

The Temporary Tooth Replacement is intended to be used as a temporary restorative application for placement in the bone of the upper arch. The purpose is to provide support for temporary, fixed cosmetic provisional restorations. The implant is intended for patients with congenitally missing teeth, primarily the Upper Lateral Incisors.

Substantial Equivalence:

The Temporary Tooth Replacement is substantially equivalent to other legally marketed devices in the United States. The Temporary Tooth Replacement functions in a manner similar to and is intended for the same use as the Monorail Transitional Implant (MTI) marketed by Dentatus.

7

1717 West Collins Avenue, Orange, CA 92867 800-537-7824 714-516-7400

{1}------------------------------------------------

Image /page/1/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States. The seal features an abstract design resembling an eagle or bird-like figure with three stylized wing or feather elements. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the emblem.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

OCT 2 4 2008

Ormco Corporation C/o Ms. Wendy Garman Director, Regulatory Affairs Sybron Dental Specialist, Incorporated 1717 West Collins Avenue Orange, California 92867

Re: K081900

Trade/Device Name: Transitional tooth Replacement (TTR) Regulation Number: 21 CFR 872.3640 Regulation Name: Endosseous Dental Implant Regulatory Class: II Product Code: DZE Dated: October 20, 2008 Received: October 23, 2008

Dear Ms. Garman:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{2}------------------------------------------------

Page 2 - Ms. Garman

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits vour device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Khmuele Kind, mD for i

Chiu S. Lin, Ph. D Division Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

K081900

Indications for Use

510(k) Number: K081900

Device Name: Transitional Tooth Replacement (TTR)

Indications For Use:

The Transitional Tooth Replacement is intended to be used as a temporary restorative application for placement in the bone of the upper arch. The purpose is to provide support for temporary, fixed cosmetic provisional restorations. The implant is intended for patients with congenitally missing teeth, primarily the Upper Lateral Incisors.

Prescription Use (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence on (ODE) Division of Anesthesiology, General Hospital Infection Control, Dental Devices

510(k) Number:

§ 872.3640 Endosseous dental implant.

(a)
Identification. An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.(b)
Classification. (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2)
Classification. Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use;
(ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads;
(iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system;
(iv) The device must be demonstrated to be biocompatible;
(v) Sterility testing must demonstrate the sterility of the device;
(vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment;
(vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians;
(viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and
(ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.