K Number
K081578

Validate with FDA (Live)

Device Name
ACCELA SYSTEM
Date Cleared
2008-06-20

(15 days)

Product Code
Regulation Number
878.4810
Age Range
All
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

Indications for Use for Fitzpatrick skin types (I to VI)

  • The removal of unwanted hair and to effect stable long-term or permanent hair reduction. Permanent hair reduction is defined as a long-term stable reduction in the number of hairs re-growing after a treatment regimen.
  • The treatment of moderate inflammatory acne vulgaris
  • The treatment of benign pigmented epidermal lesions including dyschromia, hyperpigmentation, melasma, ephelides (freckles)
  • The treatment of cutaneous lesions including warts, scars, and striae.
  • The treatment of benign cutaneous vascular lesions, including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, erythema of rosacea, angiomas, and spider angiomas, poikiloderma of civatte, leg veins and venous malformations.
    The integrated thermal cooling is indicated for use in cooling the epidermis at the treatment site prior to, during, and after light or laser treatment in general aesthetic dermatologic and plastic surgery procedures.
  • Reduce pain during and/or with light or laser treatment (via partial anesthesia from cooling)
  • Reduce discomfort during and/or associated with light or laser treatment
  • Minimize thermal injury, including thermal necrosis, to non-target skin and skin structures during and/or associated with light or laser treatment, thus reducing possible complications such as scabbing, scarring, hyper - and/or hypopigmentation
  • Allow the use of higher light or laser fluences for light or laser treatments (such as for hair removal and the treatment of vascular or pigmented lesions)
  • Reduce potential side effects of light or laser treatments (such as for hair removal and the treatment of vascular or pigmented lesions)
Device Description

The Accela is an Intense Pulsed Light-based medical device utilizing xenon flash lamp technology to illuminate the dermis to offer light based therapies as listed in the indications of use. The Accela emits light at 400nm to 1200nm via a 50mm x 50mm treatment area at a repetition rate equal to or less than 0.5Hz (operator selective). Light is delivered to the skin surface, while cold air integrated through the handpiece, is provided to cool the epidermis.

AI/ML Overview

This document is a 510(k) summary for the Accela System, an Intense Pulsed Light (IPL) device. It asserts substantial equivalence to predicate devices and describes the system's technical characteristics and indications for use. However, this document does not contain information about specific acceptance criteria, a study proving the device meets those criteria, or details regarding sample sizes, expert ground truth, or adjudication methods for clinical studies.

The provided text focuses on:

  • Device identification: Accela System, IPL, Class II device.
  • Applicant and contact information.
  • Predicate devices: Chromogenex (K053324), Sciton (K032460), Lumenis (K020839).
  • System description: Xenon flash lamp, 400nm-1200nm light, 50mm x 50mm treatment area, 0.5Hz repetition rate, integrated cold air cooling.
  • Performance Standards: Compliance with European Medical Directive 93/42/EEC and voluntary standard UL60601-1:1996 for the U.S. market.
  • Indications for use:
    • Permanent hair reduction (Fitzpatrick skin types I-VI)
    • Moderate inflammatory acne vulgaris
    • Benign pigmented epidermal lesions (dyschromia, hyperpigmentation, melasma, ephelides)
    • Cutaneous lesions (warts, scars, striae)
    • Benign cutaneous vascular lesions (port wine stains, hemangiomas, telangiectasias, rosacea erythema, angiomas, spider angiomas, poikiloderma of civatte, leg veins, venous malformations)
    • Integrated thermal cooling benefits: reduce pain/discomfort, minimize thermal injury, allow higher fluences, reduce side effects during light/laser treatment.
  • Substantial equivalence conclusion: Based on similarities to predicate devices in output spectrum, pulse characteristics, treatment parameters, despite differences in light delivery method and skin cooling method (convective cold air vs. conductive gel/contact cooling).
  • Side Effects: Excessively red patches, blistering, which usually heal without scarring if managed appropriately.
  • FDA Clearance Letter: Confirms the 510(k) clearance (K081578).

Given the absence of the requested data in the provided text, I must state that the document does not provide the information necessary to fulfill your request for acceptance criteria and the study details. A 510(k) summary typically focuses on demonstrating substantial equivalence to a legally marketed predicate device, often relying on comparisons of technological characteristics, performance data (often non-clinical), and indications for use, rather than presenting detailed clinical study results with specific performance metrics and acceptance criteria as a separate "study."

To obtain the requested information, you would typically need to consult the full 510(k) submission or any accompanying clinical studies referenced or provided by the manufacturer to the FDA.

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image contains the logo for Genesis Biosystems. The word "Genesis" is on the top line, and the word "Biosystems" is on the bottom line. The text is in a simple, sans-serif font.

JUN 2 0 2008

510(k) Summary of Safety and Effectiveness

Accela System

1

510(k) Number K_081578

Applicant:Genesis Biosystems
Address:1500 Eagle CourtLewisville, TX 75057
Contact Person:Stephen J. MacDonald, Director of Compliance
Telephone:(972) 315-7888
Fax:(972) 315-7818
Email:smacdonald@genesisbiosystems.com
Date prepared:01 / 16 / 2008
Device Trade Name:Accela System
Common Name:Intense Pulsed Light (IPL)
Classification Name:Laser Surgical Instrument 21 C.F.R § 878.4810
Product Classification:Class II device
Product Code:GEX

{1}------------------------------------------------

Image /page/1/Picture/0 description: The image contains the text "Genesis Biosystems". The word "Genesis" is on the top line, and the word "Biosystems" is on the bottom line. There is a small graphic above the "sis" in Genesis that looks like a tree.

Legally MarketedPredicate Device:The Accela System is substantially equivalent in terms oftechnological characteristics, performance, intended use,indications for use and operator interface to;
Chromogenex (K053324) Sciton (K032460) Lumenis (K020839)
System Description:The Accela is an Intense Pulsed Light-based medical deviceutilizing xenon flash lamp technology to illuminate the dermis tooffer light based therapies as listed in the indications of use. TheAccela emits *light at 400nm to 1200nm via a 50mm x 50mmtreatment area at a repetition rate equal to or less than 0.5Hz(operator selective).*Light is delivered to the skin surface, while cold air integratedthrough the handpiece, is provided to cool the epidermis.
PerformanceStandards:The device complies with the European Medical Directive93/42/EEC concerning medical devices, and will comply withvoluntary standards UL60601-1:1996 when marketed in the U.S.

Indications for use: Indications for Use for Fitzpatrick skin types (I to VI)

  • The removal of unwanted hair and to effect stable long-term or *permanent hair t reduction. *Permanent hair reduction is defined as a long-term stable reduction in the number of hairs re-growing after a treatment regimen.
  • The treatment of moderate inflammatory acne vulgaris ♥
  • The treatment of benign pigmented epidermal lesions including dyschromia, . hyperpigmentation, melasma, ephelides (freckles)
  • The treatment of cutaneous lesions including warts, scars, and striae. .
  • The treatment of benign cutaneous vascular lesions, including port wine stains, � hemangiomas, facial, truncal and leg telangiectasias, erythema of rosacea, angiomas, and spider angiomas, poikiloderma of civatte, leg veins and venous malformations.

The integrated thermal cooling is indicated for use in cooling the epidermis at the treatment site prior to, during, and after light or laser treatment in general aesthetic dermatologic and plastic surgery procedures.

{2}------------------------------------------------

Image /page/2/Picture/0 description: The image contains the text "Genesis" on the top line and "Biosystems" on the second line. The word "Genesis" is larger than the word "Biosystems". There is a small graphic above the word "Genesis" that appears to be a tree.

  • Reduce pain during and/or with light or laser treatment (via partial anesthesia from � cooling)
  • Reduce discomfort during and/or associated with light or laser treatment �
  • Minimize thermal injury, including thermal necrosis, to non-target skin and skin 0 structures during and/or associated with light or laser treatment, thus reducing possible complications such as scabbing, scarring, hyper - and/or hypopigmentation
  • Allow the use of higher light or laser fluences for light or laser treatments (such as for g hair removal and the treatment of vascular or pigmented lesions)
  • Reduce potential side effects of light or laser treatments (such as for hair removal and 0 the treatment of vascular or pigmented lesions)
  • The Accela system is substantially equivalent to its predicate devices cited Conclusion: above, based on predicate similarities. Despite the differences, the skin is treated in the same manner as the preidicate devices, Intense Pulsed Light and dermal cooling.
SimilaritiesLumenis VasculiteSciton BBLChromolight
Output Spectrum CharacteristicsSimilarSimilarSimilar
Output Pulse CharacteristicsSimilar, ProgrammableSimilar, ProgrammableSimilar, Programmable
Treatment ParametersSimilar, ProgrammableSimilar, ProgrammableSimilar
DifferencesLumenis VasculiteSciton BBLChromolight
Output Light Delivery MethodLightguide vs. WaveguideLightguide vs. WaveguideLightguide vs. Waveguide
Skin Cooling/Epidermal CoolongCold Gel vs. Cold AirGel, Contact vs. Cold AirContact vs. Cold Air
Skin Cooling MethodConductive vs. ConvectiveConductive vs. ConvectiveConductive vs. Convective

Side Effects: In extreme cases, effects from treatment can include excessively red patches in the shape of the applicator head and blistering. If this occurs the tissue should be cooled and cared for as would normally be the case with burns to the skin, i.e. do not burst any blister formation, keep clean and covered until healed.

If blisters form, they are usually intra-epidermal in nature and heal without scarring. Inappropriate management of blisters during the healing stage will increase the chance of scarring.

{3}------------------------------------------------

Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with its wings spread, along with a caduceus symbol. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Genesis Biosystems, Inc. % Underwriters Laboratories, Inc. Mr. Casey Conry 1285 Walt Whitman Road Melville, NY 11741

Re: K081578 Trade/Device Name: Accela System Regulation Number: 21 CFR 878.4810 Regulation Name: Laser surgical instrument for use in general and plastic surgery and in dermatology Regulatory Class: II Product Code: GEX Dated: March 24, 2008 Received: June 5, 2008

JUN 2 0 2008

Dear Mr. Conry:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{4}------------------------------------------------

Page 2 - Mr. Casey Conry

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Survcillance at (240) 276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Mark M. Mullican

Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{5}------------------------------------------------

Indications for Use

510(k) Number (if known):K081578
Device Name:Accela System
Indications for Use:Indications for Use for Fitzpatrick skin types (I to VI)
  • The removal of unwanted hair and to effect stable long-term or *permanent hair . reduction.
    *Permanent hair reduction is defined as a long-term stable reduction in the number of hairs re-growing after a treatment regimen.

  • The treatment of moderate inflammatory acne vulgaris t

  • The treatment of benign pigmented epidermal lesions including dyschromia, . hyperpigmentation, melasma, ephelides (freckles)

  • . The treatment of cutaneous lesions including warts, scars, and striae.

  • The treatment of benign cutaneous vascular lesions, including port wine stains, 4 hemangiomas, facial, truncal and leg telangiectasias, erythema of rosacea, angiomas, and spider angiomas, poikiloderma of civatte, leg veins and venous malformations.

The integrated thermal cooling is indicated for use in cooling the epidermis at the treatment site prior to, during, and after light or laser treatment in general aesthetic dermatologic and plastic surgery procedures.

  • Reduce pain during and/or with light or laser treatment (via partial anesthesia from . cooling)
  • Reduce discomfort during and/or associated with light or laser treatment .
  • Minimize thermal injury, including thermal necrosis, to non-target skin and skin . structures during and/or associated with light or laser treatment, thus reducing possible complications such as scabbing, scarring, hyper - and/or hypopigmentation
  • Allow the use of higher light or laser fluences for light or laser treatments (such as for . hair removal and the treatment of vascular or pigmented lesions)
  • Reduce potential side effects of light or laser treatments (such as for hair removal . and the treatment of vascular or pigmented lesions)
Prescription Use(Part 21 CFR 801 Subpart D)XAND / OROver-The-Counter-Use(Part 21 CFR 801 Subpart C)
--------------------------------------------------------------------------------------------------------------------------

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IS NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)(Division Sign-Off)
Division of General, Restorative,and Neurological DevicesPage 1 of 1
510(k) NumberK081578

§ 878.4810 Laser surgical instrument for use in general and plastic surgery and in dermatology.

(a)
Identification. (1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.
(b)
Classification. (1) Class II.(2) Class I for special laser gas mixtures used as a lasing medium for this class of lasers. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 878.9.