K Number
K063708

Validate with FDA (Live)

Device Name
4S SPINAL SYSTEM
Date Cleared
2007-04-24

(132 days)

Product Code
Regulation Number
888.3070
Age Range
All
Reference & Predicate Devices
Predicate For
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The 4STM SPINAL SYSTEM is a pedicle screw system indicated for the treatment of severe Spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bon graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.

In addition, the 4STM SPINAL SYSTEM is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative Spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor and failed previous fusion (pseudarthrosis).

Device Description

The 4STM SPINAL SYSTEM is a top-loading multiple component, posterior spinal fixation system which consists of pedicle screws, rods, bolt, and a transverse (cross) linking mechanism. The 4STM SPINAL SYSTEM will allow surgeons to build a spinal implant construct to stabilize and promote spinal fusion. The 4STM SPINAL SYSTEM implant components are supplied non-sterile, single use and fabricated from titanium alloy (Ti-6Al-4V ELI) that conforms to ASTM F136. Various sizes of these implants are available. Specialized instruments are available for the application and removal of the 4STM SPINAL SYSTEM.

AI/ML Overview

The provided text describes a 510(k) submission for the 4STM SPINAL SYSTEM, a pedicle screw spinal fixation device. The focus of the performance data in this submission is on mechanical testing rather than AI/software performance. Therefore, many of the requested categories related to AI model evaluation (such as sample size for test/training sets, expert adjudication, MRMC studies, standalone performance with AI, and ground truth establishment) are not applicable to this specific submission.

Here's an analysis based on the available information:

1. Table of Acceptance Criteria and Reported Device Performance

Acceptance Criteria (Performance Goal)Reported Device Performance
Demonstrates equivalence to predicate devices in mechanical testing, specifically to the Global Spinal Fixation System (K001668) and OPTIMA™ Spinal System (K031585).Mechanical testing conducted in accordance with ASTM F1717 demonstrates equivalence to the above predicate devices.

2. Sample Size Used for the Test Set and Data Provenance

Not applicable. The study involved mechanical testing of components, not human subject data.

3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of those Experts

Not applicable. Ground truth was established through mechanical testing standards, not expert clinical assessment.

4. Adjudication Method for the Test Set

Not applicable. Adjudication methods are relevant for human interpretation tasks, not mechanical testing.

5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

Not applicable. This is a medical device for physical implantation, not an AI-assisted diagnostic or interpretative tool.

6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

Not applicable. This device does not have an "algorithm only" component in the context of AI performance. The device itself is a standalone physical implant.

7. The Type of Ground Truth Used

The ground truth or performance standard used was established by mechanical testing protocols, specifically ASTM F1717. This standard defines the methods for bending and torsion testing of spinal implant constructs.

8. The Sample Size for the Training Set

Not applicable. There is no AI model or training set described.

9. How the Ground Truth for the Training Set was Established

Not applicable. There is no AI model or training set described.

Summary of the Study:

The study proving the device meets its acceptance criteria is a mechanical testing study. This study was conducted in accordance with ASTM F1717, a standard specification for spinal implant constructs in vitro. The results of this testing demonstrated that the 4STM SPINAL SYSTEM is mechanically equivalent to its legally marketed predicate devices: the Global Spinal Fixation System (K001668) and the OPTIMA™ Spinal System (K031585). The specific number of implants or test specimens used in this mechanical testing is not detailed in the provided text (though typically, ASTM standards require a certain number of samples for statistically valid results). The data provenance is from the manufacturing site in the Republic of Korea.

{0}------------------------------------------------

K063708
Page 1 of 2

APR 2 4 2007

510(k) SUMMARY

The following 510(k) summary is being submitted as required by 21 CFR 807.92(a):

Submission Information

US Agent:Herman Oosterwijk2001 East Oakshores Drive Aubrey, TX 76227 USA
Official Correspondent:Gil-Woon Choi204, Namdong Industrial-Complex, 45B-6L, #435-6,Nonhyun-dong, Namdong-gu, Incheon, 405-848,Republic of Korea
Sponsor:TAE YEON MEDICAL CO.,LTD.204, Namdong Industrial-Complex, 45B-6L, #435-6,Nonhyun-dong, Namdong-gu, Incheon, 405-848,Republic of Korea
Manufacturing SiteTAE YEON MEDICAL CO.,LTD.204, Namdong Industrial-Complex, 45B-6L, #435-6,Nonhyun-dong, Namdong-gu, Incheon, 405-848,Republic of Korea

Device Identification

Trade Name:4S TM SPINAL SYSTEM
Common Name:Pedicle Screw Spinal Fixation System
Classification Name:Spondylolisthesis Spinal Fixation Device System(MNH)per 21 CFR § 888.3070,
Spinal Pedicle Screw(MNI) per 21 CFR § 888.3070

Substantially Equivalent Predicate Legally Marketed Devices

The subject device, 4STM SPINAL SYSTEM, is substantially equivalent in function, design, composition, material and intended used to: Global Spinal Fixation System(K001668) and OPTIMA™, Spinal System(K031585)

Device Description

The 4STM SPINAL SYSTEM is a top-loading multiple component, posterior spinal fixation system which consists of pedicle screws, rods, bolt, and a transverse (cross) linking mechanism.

TAE YEON MEDICAL CO.,LTD.

{1}------------------------------------------------

The 4STM SPINAL SYSTEM will allow surgeons to build a spinal implant construct to stabilize and promote spinal fusion. The 4STM SPINAL SYSTEM implant components are supplied non-sterile, single use and fabricated from titanium alloy (Ti-6Al-4V ELI) that conforms to ASTM F136. Various sizes of these implants are available. Specialized instruments are available for the application and removal of the 4STM SPINAL SYSTEM.

Indications for Use

The 4STM SPINAL SYSTEM is a pedicle screw system indicated for the treatment of severe Spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bon graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.

In addition, the 4STM SPINAL SYSTEM is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative Spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor and failed previous fusion (pseudarthrosis).

Performance Data

Mechanical testing as listed in APPENDIX 10 that was conducted in accordance with ASTM F1717 demonstrates equivalence to the above predicate devices.

{2}------------------------------------------------

Image /page/2/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with its wings spread, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged in a circular fashion around the eagle. The eagle is black, and the text is also black. The logo is simple and recognizable.

Food and Drug Administration 9200 Corporate Boulevard APR 2 4 2007 Rockville MD 20850

Tae Yeon Medical Company, Limited Company c/o Mr. Gil-Woon Choi President 204, Namdong Industrial Complex, 45B-6L, #435-6 Nonhyundong, Namdong-gu, Incheon, 405-848 Republic of Korea

K063708 Trade/Device Name: 4S Spinal System Regulation Number: 21 CFR §888.3070 Regulation Name: Pedicle Screw Spinal System Regulatory Class: Class II Product Code: MNI, MNH, KWQ Dated: March 16, 2007 Received: March 26, 2007

Dear Mr. Choi:

Re:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{3}------------------------------------------------

Page 2 - Mr. Gil-Woon Choi

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FIEASE be advised that 1 27 is issually of device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the I caran suitates and regulding, but not limited to: registration and listing (21 CFR Part 807); labeling Act 3 requirements, merading bactice requirements as set forth in the quality systems (QS) (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) I mis lotter with are n yourse FDA finding of substantial equivalence of your device to a legally promatics nedicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please If you attent office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, Echolar information on your Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

[signature]

Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

2063708
Page 1 of 1

Indications for Use

5 l 0(k) Number (if known):

Device Name:

4S™ SPINAL SYSTEM

Indications for Use:

The 4STM SPINAL SYSTEM is a pedicle screw system indicated for the treatment of severe Spondylolisthesis (Grade 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.

In addition, the 4STM SPINAL SYSTEM is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative Spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, spinal tumor and failed previous fusion (pseudarthrosis).

Prescription Use (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Olabare Buelunp for Mon
(Bill) S. 28

and Neurological Devic

510(k) Number K063708

TAE YEON MEDICAL CO.,LTD.

4S™ SPINAL SYSTEM

N/A