K Number
K052527

Validate with FDA (Live)

Device Name
NEUROPROBES
Date Cleared
2006-04-12

(212 days)

Product Code
Regulation Number
882.1330
Age Range
All
Reference & Predicate Devices
N/A
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

Alpha Omega NeuroProbes are intended to be used in neurosurgery for temporary stimulation of, or recording electrical signals of a small area in the brain.

Device Description

Not Found

AI/ML Overview

The provided text is a 510(k) Premarket Notification letter from the FDA to Alpha Omega Engineering, Ltd. regarding their device, the "NeuroProbe."

This document does not contain any information about acceptance criteria or a study proving the device meets acceptance criteria.

The 510(k) letter confirms that the FDA has reviewed the premarket notification and determined the device is substantially equivalent to legally marketed predicate devices. This means the device can be marketed, subject to general controls and potentially additional controls if classified as Class II or III.

Specifically, the document lacks:

  • A table of acceptance criteria and reported device performance.
  • Information about sample sizes for test or training sets.
  • Details on data provenance.
  • Information on experts used to establish ground truth or adjudication methods.
  • Any mention of a multi-reader multi-case (MRMC) comparative effectiveness study or a standalone algorithm performance study.
  • Information about the type of ground truth used or how it was established.

The document's purpose is to grant market clearance based on substantial equivalence, not to detail performance studies or acceptance criteria met by the device.

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo is circular and contains the text "DEPARTMENT OF HEALTH AND HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles a stylized caduceus, a symbol often associated with medicine and healthcare.

Public Health Service

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

APR 1 2 2006

Alpha Omega Engineering, Ltd. c/o Mr. Shlomo Pundak QA Manager P.O. Box 810 Nazzerth Illit 17105 Israel

Re: K052527

Trade/Device Name: NeuroProbe Regulation Number: 21 CFR 882.1330 Regulation Name: Depth electrode Regulatory Class: II Product Code: GZL Dated: March 10, 2006 Received: March 20, 2006

Dear Mr. Pundak:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set

{1}------------------------------------------------

Page 2 - Mr. Shlomo Pundak

forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours,

Mark N. Melkerson

Director

Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

510(k) Number (if known): KOS2527

Device Name: NeuroProbe

Indications for Use:

Alpha Omega NeuroProbes are intended to be used in neurosurgery for temporary stimulation of, or recording electrical signals of a small area in the brain.

Prescription Use X (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

elmoe

Page 1 of 1

(Division Sign-Off Division of General, Restorative, and Neurological Devices

510(k) Number_ko5ג5ג5ג

§ 882.1330 Depth electrode.

(a)
Identification. A depth electrode is an electrode used for temporary stimulation of, or recording electrical signals at, subsurface levels of the brain.(b)
Classification. Class II (performance standards).