MTS MULTIPROGRAM TRIAL STIMULATOR SYSTEM

K033757 · Advanced Neuromodulation Systems · GZB · Jan 30, 2004 · Neurology

Device Facts

Record IDK033757
Device NameMTS MULTIPROGRAM TRIAL STIMULATOR SYSTEM
ApplicantAdvanced Neuromodulation Systems
Product CodeGZB · Neurology
Decision DateJan 30, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 882.5880
Device ClassClass 2
AttributesTherapeutic

Intended Use

Advanced Neuromodulation Systems, MTSm Multiprogram Trial Stimulator System is indicated for the treatment of chronic pain of the trunk and limbs, either as the sole mitigating agent, or as an adjunct to other modes of therapy used in a multidisciplinary approach. The MTSm Multiprogram Trial Stimulator System is intended to be used with ANS Trial Leads (percutaneous) and External Test Extensions, to deliver targeted paresthesia to single or multiple painful sites for trial stimulation either intraoperatively or post operatively for up to a maximum of thirty days.

Device Story

MTS Multiprogram Trial Stimulator System is an external device for temporary spinal cord stimulation; used to assess patient suitability for permanent implant. System components include external stimulator, percutaneous ANS trial leads, and external test extensions. Device delivers electrical pulses to spinal cord to create paresthesia at painful sites; helps manage chronic pain of trunk and limbs. Operated by clinicians intraoperatively or postoperatively; trial duration limited to 30 days. Output is targeted electrical stimulation; allows physician to evaluate pain relief efficacy before permanent system placement.

Clinical Evidence

No clinical data provided; substantial equivalence based on technological characteristics and intended use.

Technological Characteristics

External pulse generator; connects to percutaneous leads and test extensions. Delivers electrical stimulation for pain management. Class II device (21 CFR 882.5880).

Indications for Use

Indicated for patients with chronic pain of the trunk and limbs. Used as sole therapy or adjunct in multidisciplinary approach. Intended for trial stimulation (intraoperative or postoperative) for up to 30 days.

Regulatory Classification

Identification

An implanted spinal cord stimulator for pain relief is a device that is used to stimulate electrically a patient's spinal cord to relieve severe intractable pain. The stimulator consists of an implanted receiver with electrodes that are placed on the patient's spinal cord and an external transmitter for transmitting the stimulating pulses across the patient's skin to the implanted receiver.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of an eagle with three horizontal lines above it, representing the agency's mission to protect the health of all Americans and provide essential human services. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JAN 3 0 2004 Katryna Warren Senior Regulatory Affairs Specialist Advanced Neuromodulation Systems, Inc. 6501 Windcrest Drive, Suite 100 Plano, Texas 75024 Re: K033757 Trade/Device Name: MTS Multiprogram Trial Stimulation System Regulation Number: 21 CFR 882.5880 Regulation Name: Implanted Spinal Cord Stimulator for Pain Relief Regulatory Class: Class II Product Code: GZB Dated: November 26, 2003 Received: December 9, 2003 Dear Ms. Warren: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set {1}------------------------------------------------ Page 2 - Ms. Katryna Warren forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely vours. Mark A. Millman Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ 510(k) Number (if known): Device Name: MTS™ Multiprogram Trial Stimulator System Indications for Use: Advanced Neuromodulation Systems, MTSm Multiprogram Trial Stimulator System is indicated for the treatment of chronic pain of the trunk and limbs, either as the sole mitigating agent, or as an adjunct to other modes of therapy used in a multidisciplinary approach. The MTSm Multiprogram Trial Stimulator System is intended to be used with ANS Trial Leads (percutaneous) and External Test Extensions, to deliver targeted paresthesia to single or multiple painful sites for trial stimulation either intraoperatively or post operatively for up to a maximum of thirty days. ## (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) f Mark H. Melkerson (Division Sign-Off) Division of General, Restorative Neurological Devices K033757 Prescription Use (Per 21 CFR 801.109) Or Over-The-Counter Use
Innolitics
510(k) Summary
Decision Summary
Classification Order
Enter a record ID and click Load to view the document.
100%