K Number
K032534

Validate with FDA (Live)

Device Name
SYNTHES AFS
Manufacturer
Date Cleared
2004-04-01

(230 days)

Product Code
Regulation Number
888.3050
Age Range
All
Reference & Predicate Devices
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The Synthes Arch™ Fixation System is intended for use in the lower cervical and upper thoracic spine (C3-T3) after a laminoplasty has been performed. The Arch™ Fixation System holds or buttresses the allograft in place in order to prevent the allograft from expulsion or impinging on the spinal cord.

Device Description

The Synthes AFS is comprised of various sized, pre-bent mini-plates that are designed to fit the anatomy of the vertebral arch (i.e., between the pedicle and spinous process). The plates have screw holes located at the center and both ends of the plate to allow for attachment to the bone. The center hole in the plate is used for attachment to bone allograft. The plates are composed of commercially pure titanium which conforms to ASTM F67.

The screws intended for use with the mini-plates are available in a variety of lengths and diameter and are designed to match the anatomical requirements. The screws are composed of titanium alloy, Ti6Al7Nb, which conforms to ASTM F1295.

The Synthes AFS is designed to be used in conjunction with the components that comprise previously cleared Synthes posterior cervical spine products.

AI/ML Overview

This premarket notification describes a spinal fixation system, not an AI/ML device. Therefore, the typical acceptance criteria and study designs relevant to AI/ML devices (e.g., performance metrics like sensitivity/specificity, human-in-the-loop studies, ground truth establishment) are not applicable here.

The document provided, K032534 for the Synthes Arch™ Fixation System (AFS), is a 510(k) submission for a medical device that uses conventional materials and mechanical principles. The criteria for its acceptance are based on a demonstration of "substantial equivalence" to existing legally marketed predicate devices, rather than performance against a set of statistical metrics derived from AI/ML output.

Here's an analysis of the provided text in the context of device acceptance:

1. A table of acceptance criteria and the reported device performance:

Since this is not an AI/ML device, the acceptance criteria are not in the form of numerical performance metrics like sensitivity or AUC. Instead, the acceptance criteria are implicitly that the device is substantially equivalent to predicate devices in:

Acceptance Criteria CategoryReported Device Performance (Synthes AFS)
Intended Use- Indicated for use in the lower cervical and upper thoracic spine (C3-T3) after laminoplasty.- Holds or buttresses allograft in place to prevent expulsion or impingement on the spinal cord. - Claimed to be "substantially equivalent to information presented on the predicate device" for its use as a buttress plate.
Device Description/Design- Comprised of various sized, pre-bent mini-plates designed to fit vertebral arch anatomy.- Plates have screw holes for attachment to bone and bone allograft.- Used in conjunction with previously cleared Synthes posterior cervical spine products. - Claimed to be "similar in design" to currently marketed orthopedic implants.
Material- Plates: Commercially pure titanium (ASTM F67).- Screws: Titanium alloy, Ti6Al7Nb (ASTM F1295).- All components consistent with ASTM standards.- Claimed to be "similar in material" to currently marketed orthopedic implants.
Performance Characteristics- Performance characteristics comparing the Synthes AFS to commercially available devices were provided to support a determination of substantial equivalence.- Claimed to be "similar in... performance" to currently marketed orthopedic implants. The exact performance metrics for mechanical or biological function are not detailed in this summary but would have been part of the full 510(k) submission (e.g., mechanical testing data, biocompatibility reports).

2. Sample size used for the test set and the data provenance:

  • Not applicable (N/A): This is a mechanical device, not an AI/ML system that uses test sets of data for algorithm evaluation. Instead, evidence for substantial equivalence typically relies on engineering analysis, mechanical testing (e.g., fatigue, static strength), and biocompatibility testing. The document does not provide details on the specific number of units tested, but such tests would have followed established ASTM or ISO standards for medical devices. The provenance would be from laboratory testing.

3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

  • N/A: Ground truth established by expert consensus is relevant for diagnostic or image-based AI/ML devices. For a mechanical fixation system, the "ground truth" is defined by established engineering and medical standards for device function (e.g., strength, biocompatibility) and clinical outcomes that would have been evaluated in the predicate device's history.

4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

  • N/A: Adjudication methods are used in studies involving human interpretation or expert review of data (e.g., images for diagnostic AI). For a mechanical device, performance is evaluated through objective physical and chemical tests, not subjective interpretation.

5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance:

  • N/A: MRMC studies are specific to evaluating the impact of AI on human reader performance, which is not relevant for this type of mechanical spinal fixation system.

6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

  • N/A: This refers to standalone AI algorithm performance. No such algorithm is part of the Synthes AFS.

7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

  • N/A (in the AI/ML sense): For this device, the "ground truth" for demonstrating safety and effectiveness is based on:
    • Established engineering principles and material standards: Adherence to ASTM F67 (commercially pure titanium) and ASTM F1295 (titanium alloy Ti6Al7Nb) ensures the materials meet recognized safety and performance standards.
    • Mechanical testing: Though not detailed here, such devices undergo tests to confirm their structural integrity, fatigue life, and other mechanical properties under physiological loads. These tests provide objective data that serve as a form of "ground truth" for mechanical function.
    • Clinical history of predicate devices: The primary argument for "substantial equivalence" is that the AFS is similar enough to previously cleared devices (e.g., bone plates, cerclage) that their known safety and effectiveness profiles can be extrapolated to the new device. The "ground truth" here is the clinical outcomes and safety profiles established for these predicate devices over time.

8. The sample size for the training set:

  • N/A: This device does not involve a training set as it is not an AI/ML product.

9. How the ground truth for the training set was established:

  • N/A: Not applicable for a mechanical medical device.

{0}------------------------------------------------

APR = 1 2004

3.0 Summary of Safety and Effectiveness Information

SPONSOR:Synthes USA1230 Wilson DriveWest Chester, PA 19380(484) 356-9614Contact: Susan Lewandowski
DEVICE NAME:Synthes Arch™ Fixation System (AFS)
CLASSIFICATION:21 CFR §888.3050: Spinal interlaminal fixation orthosis.Product code: NQW
COMMON NAME:Appliance, fixation, interlaminal
PREDICATE DEVICE:Plate, fixation, bone:K963741 – Howmedica Leibinger Inc.K961485 – Howmedica Inc.K961497 – Howmedica Inc.Bone fixation Cerclage:K850631 – Kirschner Medical Corp.
DEVICE DESCRIPTION:The Synthes AFS is comprised of various sized, pre-bent mini-plates that are designed to fit the anatomy of the vertebral arch(i.e., between the pedicle and spinous process). The plateshave screw holes located at the center and both ends of theplate to allow for attachment to the bone. The center hole inthe plate is used for attachment to bone allograft. The platesare composed of commercially pure titanium which conforms toASTM F67.The screws intended for use with the mini-plates are availablein a variety of lengths and diameter and are designed to matchthe anatomical requirements. The screws are composed oftitanium alloy, Ti6Al7Nb, which conforms to ASTM F1295.The Synthes AFS is designed to be used in conjunction withthe components that comprise previously cleared Synthesposterior cervical spine products.
INTENDED USE:The Synthes AFS is indicated for use in the lower cervical andupper thoracic spine (C3-T3) after a laminoplasty has beenperformed. The Arch Fixation System holds or buttresses the

{1}------------------------------------------------

K032534
Page 2 of 2

The first to the country of the complement of the former of the form and

allograft in place in order to prevent the allograft from expulsion or impinging on the spinal cord.

  • All components of the Synthes AFS are manufactured from MATERIAL: commercially pure titanium (ASTM F67) or titanium alloy Ti6Al7Nb (ASTM F1295).
    PERFORMANCE Performance characteristics comparing the Synthes AFS to DATA: performance characteristics of commercially available devices were provided to support a determination of substantial equivalence.

The Synthes AFS implants are similar in design, material and BASIS OF performance to currently marketed orthopedic implants. The SUBSTANTIAL EQUIVALENCE: intended use of the product as a buttress plate is substantially equivalent to information presented on the predicate device.

Company of the program and the many of the program and the may be will be and

The For the may be the will and the same and a send a send

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is an abstract symbol resembling three stylized human figures or profiles facing to the right, stacked on top of each other. The figures are depicted in a way that suggests movement or flow.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

APR = 1 2004

Ms. Susan Lewandowski Project Manager, Regulatory Affairs Synthes (USA) 1230 Wilson Drive West Chester, Pennsylvania 19380

Re: K032534

Trade/Device Name: Synthes Arch™ Fixation System (AFS) Regulation Number: 21 CFR 888.3050 Regulation Name: Spinal interlaminal fixation orthosis Regulatory Class: II Product Code: NOW Dated: January 2, 2004 Received: January 5, 2004

Dear Ms. Lewandowski:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set

{3}------------------------------------------------

Page 2 - Ms. Susan Lewandowski

forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours.

Mark A. Milken

Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

Indications for Use Statement 2.0

Page 1 of 1

510(k) Number (if known): __ _________________________________________________________________________________________________________________________________________________

Synthes Arch™ Fixation System (AFS) Device Name:

Indications:

The Synthes Arch™ Fixation System is intended for use in the lower cervical and upper thoracic spine (C3-T3) after a laminoplasty has been performed. The Arch™ Fixation System holds or buttresses the allograft in place in order to prevent the allograft from expulsion or impinging on the spinal cord.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Prescription Use (Per 21 CFR 801.109)

OR

Over-The-Counter Use

R. Mark N. Milliman

Division of General. Restorative. and Neurological Devices

510(k) Number K032534

N/A