K Number
K013962

Validate with FDA (Live)

Date Cleared
2002-06-20

(199 days)

Product Code
Regulation Number
888.3070
Age Range
All
Reference & Predicate Devices
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The EQUATION™ Fixation System is a temporary implant system used for correction and stabilization of the posterior spine for the development of a solid spinal fusion. When used as a pedicle screw fixation system of the non-cervical posterior spine in skeletally mature patients, the EQUATION™ Fixation System is indicated for one or more of the following: (1) degenerative spondylolisthesis with objective evidence of neurologic impairment, (2) fracture, (3) dislocation, (4) scoliosis, (6) spinal tumor, and/or (7) failed previous fusion (pseudarthrosis).

In addition, when used as a pedicle screw fixation system, the EQUATION™ Fixation System is indicated for skeletally mature patients: (a) having severe spondylolisthesis (Grades 3 and 4) of the fifth lumbar-first sacral (L5-S1) vertebral joint; (b) who are receiving fusions using autogenous bone graft only; (c) who are having the device fixed or attached to the lumbar and sacral spine (L3 and below); and (d) who are having the device removed after the development of a solid fusion mass.

Device Description

The Medtronic Sofamor Danek EQUATION™ Fixation System consists of a variety of shapes and sizes of screws, nuts, and 3.6mm rods and cross connectors. The implant components can be rigidly locked in a variety of configurations, with each construct being tailor-made for the individual case. The implants are made of titanium alloy (Ti-6Al-4V) described by ASTM Standard F136 or ISO 5832-3. Stainless steel and titanium implant components must not be used together in a construct.

AI/ML Overview

The Medtronic Sofamor Danek EQUATION™ Fixation System is a temporary implant system used for correction and stabilization of the posterior spine for the development of a solid spinal fusion. The acceptance criteria and the study that proves the device meets the acceptance criteria are described below.

1. Acceptance Criteria and Reported Device Performance

Acceptance CriteriaReported Device Performance
The EQUATION™ Fixation System must demonstrate substantial equivalence in functionality and safety to the predicate device, the CD HORIZON® Spinal System, through mechanical testing.Mechanical testing was performed on the EQUATION™ Fixation System and the results were directly compared to test data previously obtained for the cleared CD HORIZON® Spinal System. The submission states that the test results supported the conclusion of substantial equivalence.

2. Sample Size and Data Provenance

The document does not explicitly state a "test set" in the context of clinical data or human subjects. The evaluation was primarily based on mechanical testing.

  • Sample size for the test set: Not explicitly stated for mechanical testing, but the implication is that sufficient units of the EQUATION™ Fixation System components were tested to make a comparison with the predicate device.
  • Data Provenance: The data is from mechanical testing of the device and its components. The country of origin for this testing is not specified, but the submitter is Medtronic Sofamor Danek USA, Inc. The data is prospective in the sense that the testing was conducted specifically for this submission.

3. Number of Experts and Qualifications for Ground Truth

Not applicable. The "ground truth" for this device's performance is established through mechanical engineering principles and testing standards, not through expert clinical consensus on images or patient data. No human experts were used to establish ground truth in the way it is typically understood for diagnostic AI.

4. Adjudication Method for the Test Set

Not applicable. As the evaluation was based on mechanical testing, there was no need for an adjudication method as would be used with human readers or clinical data. The results of mechanical tests are usually objective measurements.

5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

Not applicable. This device is a surgical implant, not a diagnostic or AI-assisted system requiring a MRMC study.

6. Standalone (Algorithm Only) Performance Study

Not applicable. This is a physical medical device (spinal fixation system), not a software algorithm.

7. Type of Ground Truth Used

The ground truth used was objective mechanical test results that demonstrate the physical performance, strength, and durability of the device components, comparing them against the established performance of the legally marketed predicate device (CD HORIZON® Spinal System). The safety and effectiveness are inferred from demonstrating equivalent mechanical properties to a device already deemed safe and effective.

8. Sample Size for the Training Set

Not applicable. There is no "training set" in the context of an AI/algorithm. For a physical device, the development and manufacturing process involves iterative design and testing, but these are not referred to as "training sets."

9. How the Ground Truth for the Training Set was Established

Not applicable as there is no training set. Design specifications and engineering requirements guide the development of such a device, and compliance with these, along with comparison to predicate devices, forms the basis of its "ground truth" for regulatory approval.

{0}------------------------------------------------

K013962

Medtronic Sofamor Danek EQUATION™ Fixation System 510(k) Summary May 2002

Submitter:Medtronic Sofamor Danek USA, Inc.1800 Pyramid PlaceMemphis, TN 38132
Contact Person:Richard TreharneSr. Vice President Regulatory Affairs
Trade Name:EQUATION™ Fixation System
Classification Name:Spinal Intervertebral Body Fixation Orthosis, Class II
Predicate Device(s):The EQUATION™ Fixation System is substantially equivalent to the CDHORIZON® Spinal System.
Device Description:The Medtronic Sofamor Danek EQUATION™ Fixation System consists of avariety of shapes and sizes of screws, nuts, and 3.6mm rods and crossconnectors. The implant components can be rigidly locked in a variety ofconfigurations, with each construct being tailor-made for the individual case.The implants are made of titanium alloy (Ti-6Al-4V) described by ASTMStandard F136 or ISO 5832-3. Stainless steel and titanium implant componentsmust not be used together in a construct.
Intended Use:The EQUATION™ Fixation System is a temporary implant system used forcorrection and stabilization of the posterior spine for the development of asolid spinal fusion. When used as a pedicle screw fixation system of the non-cervical posterior spine in skeletally mature patients, the EQUATION™Fixation System is indicated for one or more of the following: (1) degenerativespondylolisthesis with objective evidence of neurologic impairment, (2)fracture, (3) dislocation, (4) scoliosis, (5) kyphosis, (6) spinal tumor, and/or (7)failed previous fusion (pseudarthrosis).In addition, when used as a pedicle screw fixation system, the EQUATION™Fixation System is indicated for skeletally mature patients: (a) having severespondylolisthesis (Grades 3 and 4) of the fifth lumbar-first sacral (L5-S1)vertebral joint; (b) who are receiving fusions using autogenous bone graft only;(c) who are having the device fixed or attached to the lumbar and sacral spine

{1}------------------------------------------------

CO i3962 p²/2

(L3 and below); and (d) who are having the device removed after the development of a solid fusion mass.

Functionality &

Mechanical testing was performed on the EQUATION™ Fixation System and Safety Testing: was compared to test data on the previously cleared CD HORIZON® Spinal System. The test results were provided in this submission.

The EQUATION™ Spinal System is substantially equivalent to the CD Conclusion: HORIZON® Spinal System.

{2}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/2/Picture/1 description: The image is a black and white logo for the Department of Health & Human Services - USA. The logo features a circular border with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized symbol resembling an eagle or bird in flight, composed of three curved lines that suggest the wings and body of the bird.

Public Health Service

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

JUN 2-0-2002

Richard W. Treharne, Ph.D. Senior Vice President, Research and Regulatory Affairs Medtronic Sofamor Danek 1800 Pyramid Place Memphis. Tennessee 38132

Re: K013962

Trade/Device Name: EQUATION" Fixation System Regulatory Number: 21 CFR 888.3070 Regulation Name: Pedicle screw spinal system Regulatory Class: II Product Code: MNH, MNI Dated: April 16, 2002 Received: April 17, 2002

Dear Dr. Treharne:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{3}------------------------------------------------

Page 2 - Richard W. Treharne, Ph.D.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours,

R. Mark McMellon

Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

510(k) Number (if known): KO13962-

Device Name: EQUATION™ Fixation System

Indications for Use:

The EQUATION™ Fixation System is a temporary implant system used for correction and stabilization of the posterior spine for the development of a solid spinal fusion. When used as a pedicle screw fixation system of the non-cervical posterior spine in skeletally mature patients, the EQUATION™ Fixation System is indicated for one or more of the following: (1) degenerative spondylolisthesis with objective evidence of neurologic impairment, (2) fracture, (3) dislocation, (4) scoliosis, (6) spinal tumor, and/or (7) failed previous fusion (pseudarthrosis).

In addition, when used as a pedicle screw fixation system, the EQUATION™ Fixation System is indicated for skeletally mature patients: (a) having severe spondylolisthesis (Grades 3 and 4) of the fifth lumbar-first sacral (L5-S1) vertebral joint; (b) who are receiving fusions using autogenous bone graft only; (c) who are having the device fixed or attached to the lumbar and sacral spine (L3 and below); and (d) who are having the device removed after the development of a solid fusion mass.

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Evaluation (ODE)

Prescription Use(Per 21 CFR 801.109)
--------------------------------------------

OR

Over-The-Counter Use(Optional 1-2-96)
-----------------------------------------

General, Restorative and Neurological Devices 510(k) Number

N/A