(53 days)
The LactoSorb® Meniscal Screw is indicated for the repair of vertical longitudinal fullthickness tears (i.e. bucket-handle) in red-red and red-white zones. These devices are not to be used for meniscal tears in the avascular zone of the meniscus.
The LactoSorb® Meniscal Screw is made of bioresorbable and biocompatible polymers that have been used in surgical procedures for years. LactoSorb® resorbable copolymer is synthetic polyester derived from lactic and glycolic acids. Polylactic/polyglycolic acid copolymer degrades and resorbs in vivo by hydrolysis to lactic and glycolic acids, which are then metabolized by the body. The LactoSorb® material has been found in animal and clinical studies to be biocompatible in both soft tissue and bone tissue.
This document does not contain information about a study proving that the LactoSorb® Meniscal Screw meets specific acceptance criteria in terms of performance.
The provided text is a 510(k) summary for the LactoSorb® Meniscal Screw, which primarily focuses on demonstrating substantial equivalence to a predicate device (LactoSorb® Meniscal Staple, K982095) for regulatory clearance. It describes the device's intended use, materials, and provides the FDA's clearance letter.
Therefore, I cannot provide the requested information in a table or answer the specific questions about sample sizes, expert qualifications, adjudication methods, MRMC studies, standalone performance, or ground truth for a performance study.
The only relevant information that can be extracted is:
- Device Name: LactoSorb® Meniscal Screw
- Intended Use: Repair of vertical longitudinal full-thickness tears (i.e., bucket-handle) in red-red and red-white zones of the meniscus. Not to be used for meniscal tears in the avascular zone.
- Predicate Device: LactoSorb® Meniscal Staple (K982095)
- Material: Bioresorbable and biocompatible polymers (LactoSorb® resorbable copolymer, synthetic polyester derived from lactic and glycolic acids).
- Material Evidence: "The LactoSorb® material has been found in animal and clinical studies to be biocompatible in both soft tissue and bone tissue." (This is a general statement about the material, not a specific performance study of the screw device itself.)
{0}------------------------------------------------
AUG 2 5 2000
Koo2020
510 (K) Summary of Safety and Effectiveness
Biomet, Inc. Submitter: 56 East Bell Drive P.O. Box 587 Warsaw, IN 46581-0587
Contact Person: Mary L. Verstynen
Product Code: MAI
Device Name: LactoSorb® Meniscal Screw
The LactoSorb® Meniscal Screw is indicated for the repair of vertical longitudinal fullthickness tears (i.e. bucket-handle) in red-red and red-white zones. These devices are not to be used for meniscal tears in the avascular zone of the meniscus.
The LactoSorb® Meniscal Screw is made of bioresorbable and biocompatible polymers that have been used in surgical procedures for years. LactoSorb® resorbable copolymer is synthetic polyester derived from lactic and glycolic acids. Polylactic/polyglycolic acid copolymer degrades and resorbs in vivo by hydrolysis to lactic and glycolic acids, which are then metabolized by the body. The LactoSorb® material has been found in animal and clinical studies to be biocompatible in both soft tissue and bone tissue.
Predicate Device:
The LactoSorb® Meniscal Screw is substantially equivalent to the following:
- LactoSorb® Meniscal Staple
The LactoSorb® Meniscal Screw described in this notification has the same intended use and characteristics as the LactoSorb® Meniscal Staple.
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles a stylized caduceus or a series of interconnected human profiles. The image is in black and white.
AUG 2 5 2000
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Ms. Mary L. Verstynen Manager of Clinical Affairs Biomet Inc. P.O. Box 587 Warsaw. Indiana 46581
Re: K002020
Trade Name: LactoSorb® Meniscal Screw Regulatory Class: II Product Code: MAI Dated: June 30, 2000 Received: July 3. 2000
Dear Ms. Verstynen:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing.of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General Regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
{2}------------------------------------------------
Page 2 - Ms. Mary L. Verstynen
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597, or at its Internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Norell Suize
Lelia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
Page _ of _
510(k) NUMBER (IF KNOWN):
K002020
DEVICE NAME: LactoSorb® Meniscal Screw
INDICATIONS FOR USE:
The LactoSorb Meniscal Screw is indicated for the repair of vertical longitudinal full thickness tears (i.e. bucket-handle) in the red-red and red-white zones. These devices are not to be used for meniscal tears in the avascular zone of the meniscus.
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED.)
Concurrence of CDRH, Office of Device Evaluation (ODE)
12 Prescription Use 5 (Per 21 CFR 801.109)
OR
Over-The-Counter-Use
(Optional Format 1-2-96)
Nussly Lyon
(Division Sign-Off) Division of General Restorative Devices 510(k) Number _ 00 2020