Found 196 results

510(k) Data Aggregation

    K Number
    K253185

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-03-11

    (166 days)

    Product Code
    Regulation Number
    892.1720
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Lux HD Detectors, DRX-LC Detector, DRX-Revolution Mobile X-Ray System
    Regulation Number: 21 CFR 892.1720
    Imager) |
    | Device Class | Class II |
    | Device Code(s) | IZL, MQB |
    | Regulation Number(s) | 892.1720

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    DRX-Revolution Mobile X-ray System

    The device is designed to perform radiographic x-ray examinations on all pediatric and adult patients, in all patient treatment areas.

    Lux HD Detectors

    Lux HD 35 Detector and Lux HD 43 Detector are indicated for digital imaging solutions designed to provide general radiographic diagnosis for human anatomy including both adult and pediatric patients. They are intended to replace film/screen systems in all general–purpose diagnostic procedures. Lux HD 35 Detector and Lux HD 43 Detector are not intended for mammography or dental applications.

    DRX-LC Detector

    DRX-LC, as a major imaging component, are supplied to the manufacturers of medical diagnostic X-ray photography systems and used in conjunction with the medical diagnostic X-ray photography system to image the object to be checked. They are capable of outputting the acquired static images to a processing device after acquisition.

    Device Description

    The DRX-Revolution Mobile X-ray system will support the new Lux HD Detectors with the DEC function (K243556), additionally the detectors will also support the optional SNC feature (K241505).

    Carestream Mobile X-ray Systems

    DRX-Revolution Mobile X-Ray System is a mobile diagnostic x-ray system that utilizes digital technology for bedside or portable exams. Key components of the system are the x-ray generator, a tube head assembly (includes the x-ray tube and collimator) that allows for multiple axes of movement, a maneuverable drive system, touchscreen user interface(s) for user input. It is a mobile diagnostic system intended to generate and control X-rays for examination of various anatomical regions.

    Lux HD Detectors (35x43, 43x43 sizes)

    Lux HD 35x43 and 43x43 detectors are high-definition detectors (100um) designed with a Cesium Iodide scintillator for the conversion from X-ray to visible photon. The visible photons are transformed to electron signals by a diode capacitor array within TFT panel, which are composed and processed by connecting to scanning and readout electronics to form an image by transmitting to the device PC through the user interface. The CsI scintillator provides a high spatial resolution image.

    The detectors use a glass free technology which makes the overall detector weight lighter and mitigates the risks related to device breakage. Lux HDs are designed with Digital Exposure Control (DEC) functionality which uses a wireless connection to communicate with a DEC control box, which in turn connects to the generator for x-ray control. This DEC feature also enables AEC functions to be used for mobile imaging without a physical wired connection. These detectors will integrate into the DRX-Revolution X-ray system

    DRX-LC Detector

    DRX-LC digital flat panel detector is a large-sized X-ray flat panel detector with wireless function based on amorphous silicon (a-Si) thin film transistor (TFT) technology. It utilizes a cesium iodide (CsI) scintillator, and a 3064×8696 active pixel matrix with a pixel size of 139μm, providing high-quality radiographic images.

    The DRX-LC is designed with DEC feature (same as above) using two additional accessories to support DEC function, a wireless control box and wireless transmission adapter. This detector will integrate into the DRX-Revolution X-ray system.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary primarily describe the substantial equivalence of the Carestream Lux HD Detectors, DRX-LC Detector, and DRX-Revolution Mobile X-Ray System with integrated Smart Noise Cancellation (SNC) feature. The document focuses on demonstrating that the modified device (with SNC) is as safe and effective as existing predicate devices.

    Here's an attempt to extract the requested information about acceptance criteria and the study proving performance, based on the provided text. It's important to note that the document is a summary and may not contain all the granular details typically found in a full study report.


    Acceptance Criteria and Reported Device Performance

    The core acceptance criterion for the Smart Noise Cancellation (SNC) feature, as implied by the clinical and non-clinical testing, is that images processed with SNC should be equivalent to or better than images processed without SNC (the predicate device) in terms of diagnostic quality, noise reduction, and preservation of fine detail, potentially while enabling dose reduction.

    Acceptance Criteria CategorySpecific Criteria (Inferred from Study Outcomes)Reported Device Performance (SNC)
    Overall Image PreferenceSignificantly higher preference for SNC processed images by radiologistsp = 0.000 (meaningful level in favor of SNC)
    Image Quality (RadLex Score)Image quality for SNC to be as good as or better than images without SNC with diagnostic qualityp = 0.000; mean RadLex score of 3.4 ("Diagnostic"); >99.7% of SNC RadLex images rated same or higher than non-SNC
    Dose Reduction CapabilitySimilar image quality (IQFinv) at 50% reduced dose with SNC compared to nominal dose without SNCCDRAD phantom showed similar IQFinv
    Diagnostic Quality at Reduced DoseSimulated reduced-dose images with SNC to be of diagnostic quality comparable to nominal-dose images without SNCDemonstrated comparable diagnostic quality based on RadLex ratings
    Hardware AppearanceHardware appearance as good as or better than the predicate deviceSNC produces images with hardware appearance as good as or better than the predicate device
    Noise ReductionSignificant noise reductionSignificant noise reduction observed in non-clinical testing
    Sharpness/Spatial ResolutionNoise reduction without impacting sharpness and retaining image spatial resolutionNon-clinical testing demonstrated retention of image spatial resolution
    Contrast-to-Noise RatioImproved contrast-to-noise ratio at clinically nominal exposuresClaim verified: "SNC provides improved diagnostic quality, preservation of fine detail and better contrast-to-noise ratio for images acquired at clinically nominal exposures."

    Study Proving Device Meets Acceptance Criteria

    The study described is a clinical study combined with non-clinical testing designed to evaluate the image quality performance and technical characteristics of SNC.

    1. Sample sizes used for the test set and the data provenance:

      • Clinical Study (Reader Study):
        • Images: Images were obtained from 7 mobile systems at 8 different sites. These images were acquired using:
          • Live subjects (actual live patient images, likely used for nominal dose comparisons for RadLex scores)
          • Anthropomorphic phantoms
          • Adult cadaveric specimens
          • Live patient images with simulated dose reduction.
          • Images of human cadavers and anthropomorphic phantoms obtained using actual reduced-dose X-ray exposures.
        • Data Provenance: The document does not explicitly state the country of origin but implies multiple clinical sites. It includes both retrospective (live patient images) and prospective (phantom/cadaver, simulated reduced dose) elements.
      • Non-Clinical Testing:
        • Images: Captures of flat fields and physics phantoms (e.g., CDRAD phantom).
        • Data Provenance: Not specified, but generally conducted in a lab environment.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience):

      • Number of Experts: Four independent, board-certified diagnostic radiologists.
      • Qualifications: "Board-certified diagnostic radiologists." Specific years of experience are not mentioned.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • The document describes a "reader study" where the four radiologists "compared pairwise live patient images." This indicates that each image pair (with and without SNC) was evaluated, and their ratings (RadLex scores and preference) were analyzed. It does not explicitly state a specific adjudication method like 2+1 or 3+1 for resolving discrepancies, but rather statistical analysis of their collective ratings (e.g., "Overall preference is in favor of SNC at a meaningful level (p = 0.000)").
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • Yes, an MRMC-like comparative effectiveness study was done. The study involved four independent, board-certified radiologists comparing images processed with and without SNC.
      • Effect Size of Human Reader Improvement: The document does not directly quantify "human reader improvement" in terms of efficiency or diagnostic accuracy in a specific effect size metric (e.g., AUC increase, time reduction). However, it reports:
        • Overall preference: "in favor of SNC at a meaningful level (p = 0.000)."
        • Image quality: "as good as or better than images without SNC (p = 0.000), regardless of image type, with a mean RadLex score of 3.4 ("Diagnostic")."
        • Rating Improvement: "Greater than 99.7% of the SNC RadLex images were rated the same as or higher than the non-SNC images."
        • This indicates a strong positive impact of SNC on the radiologists' perception and rating of image quality, suggesting an indirect improvement in their ability to achieve diagnostic quality, especially at reduced doses.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Yes, the "Non-Clinical Testing" section describes standalone algorithm performance evaluations.
        • "IQ testing was performed, which specifically characterizes SNC performance using quantitative methods of analysis of non-clinical data."
        • "The predicate and subject devices were evaluated using captures of flat fields and physics phantoms."
        • "The images from both devices were quantitatively compared using Normalized Noise Power Spectra (NNPS), standard deviation (noise) of flat sections of the images, Modulation Transfer Function (MTF), and the contrast-detail curve."
        • This directly assesses the algorithm's effect on image characteristics without human interpretation.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

      • Clinical Study:
        • Expert Consensus/Ratings: The primary ground truth for image quality and diagnostic utility was established through ratings and pairwise comparisons by four board-certified diagnostic radiologists, using metrics like "RadLex scores" and "Overall preference."
        • Phantom/Cadaveric Data: For dose reduction comparisons, images of anthropomorphic phantoms and human cadavers acquired at actual reduced doses served as a controlled "ground truth" to assess the algorithm's ability to maintain image quality under these conditions.
      • Non-Clinical Testing:
        • Physics Phantoms & Quantitative Metrics: The ground truth involved established quantitative metrics of image quality (NNPS, noise, MTF, contrast-detail curve) applied to images of physics phantoms and flat fields, allowing for objective measurement of the algorithm's impact on technical image parameters.
    7. The sample size for the training set:

      • The document does not specify the sample size for the training set of the Smart Noise Cancellation (SNC) algorithm. The provided text only focuses on the device's performance validation, not its development or training data.
    8. How the ground truth for the training set was established:

      • Since the training set sample size is not provided, the method for establishing its ground truth is also not described in this document.
    Ask a Question

    Ask a specific question about this device

    K Number
    K253244

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-02-23

    (147 days)

    Product Code
    Regulation Number
    892.1720
    Age Range
    18 - 999
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    80A, AirRay-mini 90A, AirRay-mini 80F, AirRay-mini 90F (AirRay-mini)
    Regulation Number: 21 CFR 892.1720
    Name | Mobile x-ray unit |
    | Regulation Name | Mobile x-ray system. |
    | Regulation Number | 21 CFR 892.1720
    Name | Mobile x-ray system |
    | Regulation Name | Mobile x-ray system |
    | Regulation Number | 21 CFR 892.1720
    | AirRay-mini | ADX6000 | - |
    | Product Code | IZL | IZL | Identical |
    | Regulation Number | 21 CFR 892.1720
    | 21 CFR 892.1720 | Identical |
    | 510(k) Review Panel | RADIOLOGY | RADIOLOGY | Identical |
    | Indications

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AirRay-mini is a handheld, portable X-ray generator.

    This device is intended for use by qualified and trained healthcare professionals on adult patients to produce diagnostic X-ray images of the extremities.

    This device is not intended for mammography.

    Device Description

    The AirRay-mini is a portable, battery-powered X-ray generator intended to provide controlled X-ray radiation for use with separately cleared solid-state detectors or digital radiography systems. The device consists of an X-ray control unit, a high-voltage generator, an X-ray tube assembly, a hand switch, and associated electronics.

    DC power from the internal battery is supplied to the inverter, which generates a high-voltage output applied across the X-ray tube. Electrons emitted from the cathode are accelerated toward the anode target, where their deceleration produces X-ray radiation. The device delivers X-rays according to user-selected parameters such as tube voltage (kV), tube current (mA), and exposure time (mAs).

    The AirRay-mini does not include an image receptor and does not acquire or process diagnostic images. Diagnostic image formation and quality depend entirely on the separately paired imaging system.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252068

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-12-22

    (174 days)

    Product Code
    Regulation Number
    892.1650
    Age Range
    0 - 150
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    OWB, JAA | Identical to Predicate |
    | Regulation Number | 21 CFR 892.1650 | 21 CFR 892.1650 | 21 CFR 892.1720

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The MC2 Portable X-ray System is indicated for use by qualified/trained medical professionals on adult and pediatric patients for:

    • Handheld orthopedic radiographic procedures of the extremities.
    • Handheld orthopedic serial radiographic procedures of the extremities, excluding the shoulder, hip, and knee. Handheld serial radiographic imaging is limited to forward holding position only.
    • Stand-mounted orthopedic radiographic, serial radiographic, fluoroscopic, and orthopedic interventional procedures of the extremities, inclusive of shoulders and knees.

    The device is NOT intended for use during surgery. The device is NOT intended to replace a stationary radiographic or fluoroscopic system, which may be required for optimization of image quality and radiation exposure.

    The device is to be used in healthcare facilities where qualified operators are present (e.g., outpatient clinics, urgent cares, imaging centers, sports medicine facilities, occupational medicine clinics).

    The device is NOT intended to be used in environments with the following characteristics:

    • Aseptic or sterile fields, such as in surgery
    • Home or residential settings or other settings where qualified operators are not present
    • Vehicular and moving environments
    • Environments under direct sunlight
    • Oxygen-rich environments, such as near an operating oxygenation concentrator
    Device Description

    The MC2 Portable X-ray System ("MC2 System" or "MC2") is a portable and handheld X-ray system designed to aid clinicians with point-of-care visualization through diagnostic X-rays of the shoulders to fingertips and knees to toes. The device allows clinicians to select desired technique factors best suited for their patient's anatomy. The MC2 consists of two major system components: the emitter and the cassette. The MC2 emitter and cassette are battery-powered and are charged via a wired charger. The system is intended to interface wirelessly to an external tablet when used with the OXOS Device App or to a monitor with an off-the-shelf ELO Backpack and the OXOS Device App. The MC2 utilizes an Infrared Tracking System to allow the emitter to be positioned above the patient's anatomy and aligned to the cassette by the operator. The MC2 also utilizes a LIDAR system to ensure patient safety by maintaining a safe source-to-skin distance.

    The MC2 is capable of three X-ray imaging modes: single radiography, serial radiography, and fluoroscopy. In single and serial radiography modes, the user can utilize the entire range of kV values (40-80kV), while fluoroscopy mode is limited to 40-64kV. In single radiography mode, the user can utilize the entire range of mAs values, while serial radiography and fluoroscopy are limited to 0.04-0.08 mAs.

    The MC2 contains various safety features to ensure patient and operator safety. The primary interlocks that ensure system geometry is maintained include a source-to-image distance interlock, an active area interlock, a source-to-skin distance interlock, and a stand-mounted interlock.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250976

    Validate with FDA (Live)

    Device Name
    Airbile-100
    Manufacturer
    Date Cleared
    2025-12-19

    (263 days)

    Product Code
    Regulation Number
    892.1720
    Age Range
    0 - 150
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    10543
    REPUBLIC OF KOREA

    Re: K250976
    Trade/Device Name: Airbile-100
    Regulation Number: 21 CFR 892.1720
    Name | Mobile x-ray unit |
    | Regulation Name | Mobile x-ray system. |
    | Regulation Number | 21 CFR 892.1720
    Name | Mobile x-ray system |
    | Regulation Name | Mobile x-ray system |
    | Regulation Number | 21 CFR 892.1720
    | Airbile-100 | AMADEO M-DR mini | - |
    | Product Code | IZL | IZL | |
    | Regulation Number | 21 CFR 892.1720
    | 21 CFR 892.1720 | |
    | 510(k) Review Panel | RADIOLOGY DEVICES | RADIOLOGY DEVICES | |
    | Indications

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Airbile-100 Mobile X-ray Unit is intended for use by a qualified/trained doctor or technician on both adult and pediatric subjects for taking diagnostic radiographic exposures of the skull, spinal column, chest, abdomen, extremities, and other body parts.

    Applications can be performed with the patient sitting, standing, or lying in the prone or supine position.

    Device Description

    The 'Airbile-100' is a battery-powered mobile X-ray imaging device mainly used for hospital rounds and consists of an X-ray control unit, a high-voltage generator, an X-ray tube unit, a hand switch, etc. Inverter X-ray high-voltage device, electrons are generated from the tungsten filament on the cathode side of the X-ray tube. DC power is supplied to the inverter by a battery, and a high-frequency, stable, high-voltage DC output voltage with an amplified high frequency is applied between the cathode and anode, so that the generated electrons move at high speed due to the voltage difference and are slowed down by striking the target material on the anode, and the energy is converted, and the X-rays generated by the energy conversion are passed to the human body parts for the necessary diagnosis of the patient. It is a device that can generate X-rays according to the set values such as supply voltage, supply current, and irradiation time and take pictures for the necessary diagnosis of the patient.

    Additionally, it should be noted that the Airbile-100 does not include the X-ray detector. For image acquisition, an external X-ray detector must be used in combination with this device.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251710

    Validate with FDA (Live)

    Date Cleared
    2025-10-24

    (143 days)

    Product Code
    Regulation Number
    892.1720
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    M1)
    Regulation Number: 21 CFR 892.1720
    Regulation Name: Mobile X-Ray System
    **Regulatory
    System, X-ray, Mobile
    Classification Name: Mobile x-ray system
    Regulation Number: 21 CFR 892.1720
    Mobile x-ray system
    Classification Name: Mobile x-ray system
    Regulation Number: 21 CFR 892.1720
    M1 | EQUIVALENT |
    | Regulation Number | 21 CFR 892.1720 | 21 CFR 892.1720 | EQUIVALENT |
    | Common Name

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is designed to perform general radiography x-ray examinations on all pediatric and all adult patients, in all patient treatment areas.

    Treatment areas are defined as professional health care facility environments where operators with medical training are continually present during patients' examinations.

    Device Description

    The !M1 mobile X-ray system is a diagnostic mobile X-ray system utilizing digital radiography (DR) technology. The device consists of a self-contained x-ray generator, image receptor(s), imaging display, and software for acquiring medical diagnostic images both inside and outside of a standard stationary x-ray room. The !M1 system incorporates a flat-panel detector(s) that can be used wirelessly for exams such as in-bed projections. The system can also be used to expose CR phosphor screens or film.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K243864

    Validate with FDA (Live)

    Device Name
    BONX805
    Manufacturer
    Date Cleared
    2025-09-12

    (269 days)

    Product Code
    Regulation Number
    892.1720
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Gyeonggi-do 16990
    SOUTH KOREA

    Re: K243864
    Trade/Device Name: Bonx805
    Regulation Number: 21 CFR 892.1720
    Health (OHT8)
    Radiological Imaging Devices and Electronic Products (DHT8B)
    Regulation Number: 892.1720
    Name:** Mobile X-Ray System
    Regulation Name: Mobile X-Ray System
    Regulation Number: 21 CFR 892.1720

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BONX805 is a portable X-ray system for diagnostic imaging of body extremities.

    Intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays.

    Device Description

    BONX805 is portable X-ray unit integrated with small computer. BONX805 goes with you no matter where the patient is (hospitals, clinics, nursing home and out-of-office mobile use). One unit can serve all the operators in your practice. BONX805 was designed to help doctors and radiologists for exact diagnosis with clear X-ray images and safety from unnecessary radiation exposure. This device shall be used in professional healthcare environment. An x-ray detector (necessary component for a fully-functional diagnostic system) is not part of the device.

    Basic functions of the subject device BONX805 are supported by software(firmware). The firmware of portable X-ray is a software which installed in product to operate BONX805. The firmware is installed in the hardware (embedded system). The firmware(Version: REV 1.00) controls the use mode and irradiation, also the firmware is expected to unchanged during its lifetime.

    BONX805 generates and controls X-rays using the power of the built-in battery, and irradiation is absolutely prohibited during charging. X-ray irradiation is controlled by the designed electronic circuit and MCU, and among the conditions necessary for shooting, the tube voltage is adjustable and the tube current is fixed. The irradiation time is set manually, and the value adjusted by the MCU electronically controls the semiconductor switching element. Using this X-ray, it passes through the body part to be diagnosed to obtain an image with a detector so that it can be used for diagnosis. The irradiation time setting method sets the irradiation time by the user turning the dial manually. After setting, press the exposure button.

    The BONX805 should be used with an X-ray detector, and this detector has a digital type and a film type. But the X-ray detector is not included in the BONX805 package.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251443

    Validate with FDA (Live)

    Device Name
    PROMO
    Manufacturer
    Date Cleared
    2025-08-22

    (105 days)

    Product Code
    Regulation Number
    892.1720
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Gyeonggi 14322
    SOUTH KOREA

    Re: K251443
    Trade/Device Name: Promo
    Regulation Number: 21 CFR 892.1720
    PROMO
    Classification Name: Mobile X-ray System
    Product Code: IZL
    Regulation Number: 892.1720

    • Mobile X-ray System
      510(k) Number: K242015
      Product Code: IZL
      Regulation Number: 892.1720
      , Mobile | System, X-ray, Mobile | Same |
      | Product Code | IZL | IZL | Same |
      | Regulation Number | 892.1720
      | 892.1720 | Same |
      | Associated Product Code | MQB | MQB | Same |
      | Regulatory Class | II | II | Same
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The PROMO is intended for use in obtaining human anatomical images of patients who cannot be moved to the radiology department for medical diagnosis.

    Device Description

    The PROMO is based on predicate device TOPAZ and the x-ray detectors are the same as the predicate system. The PROMO is moved smoothly with manual by user. The core part of x-ray source adopts high quality tube assembly, x-ray collimator, HV cable assembly and High Voltage x-ray Generator with excellent performance, lifetime and stability. Digital flat panel detector with CsI screen provides excellent spatial resolution, MTF, DQE and stability based on fine pixel pitch. The core part of x-ray source adopts high quality tube assembly, x-ray collimator, HV cable assembly and High Voltage x-ray Generator which have worldwide reputation on excellent performance, lifetime and stability. Touch screen LCD based x-ray control console provides user-friendly interface and easy technique selection. Collimator supports high accuracy for selected x-ray field size over any SID. The PROMO include imaging software that is the RADMAX. The RADMAX software can perform processing the radiological image acquired from solid state x-ray imaging device. The RADMAX software is based on predicate device TOPAZ. The CTR function is a manual quantitative imaging feature that allows users to measure the cardiothoracic ratio by manually selecting points using a mouse. The software function has been verified and validated as safe and effective.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for the PROMO Mobile X-ray System do not contain information about specific acceptance criteria, reported device performance metrics in relation to those criteria, or details of a clinical study that proves the device meets acceptance criteria.

    The document primarily focuses on demonstrating substantial equivalence to a predicate device (TOPAZ) through non-clinical performance testing and compliance with various recognized standards and guidance documents. It confirms that the device's image performance was evaluated through bench testing.

    Therefore, for the specific questions asked, most of the information is not available in the provided text.

    Here's an breakdown of what can and cannot be answered based on the provided document:


    Information that CANNOT be provided from the document:

    • 1. A table of acceptance criteria and the reported device performance: The document mentions "bench testing was conducted to evaluate the image performance of the detector" and that "PROMO meets or exceeds TOPAZ in key image quality metrics such as uniformity, SNR, linearity, spatial resolution, and low contrast resolution." However, it does not provide specific numerical acceptance criteria for these metrics nor the quantitative reported performance of the device against them.
    • 2. Sample size used for the test set and the data provenance: Since no clinical study or specific test set with patient data is described, this information is not available. The "test set" mentioned refers to non-clinical bench testing.
    • 3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable as no clinical study involving expert interpretation is detailed.
    • 4. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable as no clinical study involving expert interpretation is detailed.
    • 5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. The PROMO is a mobile X-ray system, not an AI diagnostic tool, and the document does not describe any MRMC studies. The "CTR function" mentioned is a manual measurement tool, not an AI feature for diagnostic assistance.
    • 6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable, as this device itself is the imaging hardware, not an AI algorithm.
    • 7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): For the non-clinical bench testing mentioned, the "ground truth" would be objective physical measurements of image quality parameters (e.g., standard phantoms for linearity, resolution, etc.). The document does not describe clinical ground truths.
    • 8. The sample size for the training set: The document does not describe any machine learning or AI models with a "training set."
    • 9. How the ground truth for the training set was established: Not applicable, as no training set is mentioned.

    Information that CAN be inferred or directly stated from the document (regarding non-clinical testing and general acceptance):

    The document implicitly defines "acceptance criteria" by stating compliance with recognized national and international standards for medical electrical equipment, radiation protection, usability, software life cycle, risk management, and cybersecurity. The "study" that proves the device meets these (non-clinical) acceptance criteria is the bench testing and verification/validation processes conducted according to these standards.

    1. A table of acceptance criteria and the reported device performance:

    AspectAcceptance Criteria (from document)Reported Device Performance (from document)
    Image Quality MetricsMeeting or exceeding predicate device (TOPAZ) performance in key image quality metrics. Implicitly, compliance with industry standards for image quality."PROMO meets or exceeds TOPAZ in key image quality metrics such as uniformity, SNR, linearity, spatial resolution, and low contrast resolution." (supported by objective bench testing data)
    SafetyCompliance with IEC 60601-1 (General requirements for basic safety and essential performance), IEC 60601-2-28 (X-ray tube assemblies), IEC 60601-2-54 (X-ray equipment for radiography and radioscopy).Verified through testing to international safety standards. Differences from predicate do not negatively impact safety.
    Electromagnetic Compatibility (EMC)Compliance with IEC 60601-1-2 (Electromagnetic disturbances).Verified through testing to international EMC standards.
    Radiation ProtectionCompliance with IEC 60601-1-3 (Radiation protection in diagnostic X-ray equipment) and IEC 61910-1 (Radiation dose documentation).Testing confirmed compliance.
    UsabilityCompliance with IEC 60601-1-6 and IEC 62366-1 (Usability engineering).Testing confirmed compliance.
    Risk ManagementCompliance with ISO 14971 (Application of risk management to medical devices).Potential vulnerabilities identified via cybersecurity risk analysis; design integrates security controls.
    Software Life CycleCompliance with IEC 62304 (Medical device software). Software development process for RADMAX.RADMAX software is "Basic Documentation Level," "verified and validated as safe and effective."
    CybersecurityCompliance with FDA Guidances on Cybersecurity. Ensuring confidentiality, integrity, and availability of data and systems.Device "complies with cybersecurity requirements," identified vulnerabilities through risk analysis, design integrates security controls (authentication, encryption, etc.). Verification and tests conducted.
    DICOM ConformanceCompliance with NEMA PS 3.1 - 3.20 (DICOM Set).Testing confirmed compliance.
    Pediatric InformationCompliance with FDA Guidance on Pediatric X-ray Imaging Devices.Testing confirmed compliance.
    Detector PerformanceMaintenance of performance characteristics (uniformity, SNR, linearity, spatial resolution, low contrast resolution) despite system changes."The results showed that PROMO meets or exceeds TOPAZ in key image quality metrics such as uniformity, SNR, linearity, spatial resolution, and low contrast resolution."

    Summary regarding the device performance study:

    The PROMO Mobile X-ray System's substantial equivalence to its predicate (TOPAZ) and its safety and effectiveness are established through non-clinical performance testing (bench testing). This testing focused on comparing technical specifications and image quality metrics against the predicate and ensuring compliance with a comprehensive set of international and FDA-recognized standards and guidance documents. The document explicitly states: "Bench testing was conducted to evaluate the image performance of the detector. The results showed that PROMO meets or exceeds TOPAZ in key image quality metrics such as uniformity, SNR, linearity, spatial resolution, and low contrast resolution. Therefore, the substantial equivalence in image quality performance is supported by objective bench testing data."

    Type of ground truth used (for bench testing):

    For the non-clinical bench testing, the ground truth would be established by objective physical measurements using standardized phantoms and test objects to assess imaging characteristics (e.g., bar patterns for spatial resolution, step wedges for linearity, uniform fields for uniformity).

    Ask a Question

    Ask a specific question about this device

    K Number
    K251223

    Validate with FDA (Live)

    Device Name
    HnX-P1, HnX-PB
    Manufacturer
    Date Cleared
    2025-08-04

    (105 days)

    Product Code
    Regulation Number
    892.1720
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    17118
    SOUTH KOREA

    Re: K251223
    Trade/Device Name: HnX-P1, HnX-PB
    Regulation Number: 21 CFR 892.1720
    Portable X-ray System |
    | Device Classification Name | Mobile X-ray System |
    | Regulation Number | 21 CFR 892.1720
    Mobile x-ray system

    • Classification Name: System, X-ray, Mobile
    • Regulation Number: 21 CFR 892.1720
      Portable X-ray system | Portable X-ray system |
      | Product Code | IZL | IZL |
      | Regulation Number | 21 CFR 892.1720
      | 21 CFR 892.1720 |
      | 510(k) Review Panel | Radiology | Radiology |
      | Indications for Use | The portable
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The portable x-ray system may be used for diagnostic imaging of body extremities.

    • Not for mammography use
    • This device is not intended to replace a stationary radiographic system, which may be required for full optimization of image quality and radiation exposure for different exam types.
    Device Description

    This device is a battery-powered portable X-ray System, designed and manufactured by H&abyz. This portable radiographic system (Model: HnX-P1, HnX-PB) consists of an LCD display with up and down soft-keys for controlling kV, an X-ray generator (line-powered transformer), an X-ray tube assembly, a collimator and a cart. It can also use a stand instead of a cart. The HnX-P1 is used with a film-cassette or flat-panel detector. (The film-cassette or flat-panel detector, cart, and stand are not included in the basic components of the product.)

    The major components of the X-ray main unit include handle, enclosure, main control panel, system control board, high-voltage tank, inverter, collimator (beam limiter), and system control software running on the system control board. The system control software is for real-time interaction and control with various circuit modules inside the X-ray generator. The software responds to user operations on the control panel. The user can adjust and control the kV and mAs parameters, and the software will display the parameters or directly load the APR parameters. The software loads the control data from X-ray output into the high-voltage generation control circuit of the system control board, and control the high-voltage tank to generate high-voltage to excite the X-ray tube inside to emit X-rays, control the switch of the collimator, and monitor the working status of the device, and control the display of the status indicators.

    The system is for X-ray imaging and diagnosis in facilities with portable or fixing sites. The device can be used with an X-ray flat panel detector, a computer for receiving and detecting signal results and an image processing software. This portable X-ray System is designed for handheld or stand-mounted imaging.

    AI/ML Overview

    It appears there may be a misunderstanding or a gap in the provided document regarding acceptance criteria and the study proving the device meets them. The document is an FDA 510(k) clearance letter for a portable X-ray system (HnX-P1, HnX-PB), and it does not contain information about acceptance criteria for AI/software performance or a study proving the device meets such criteria.

    The document explicitly states several times that "Clinical studies were not performed." (Page 10, Section 8 on "Clinical studies"). This means there was no clinical evaluation of diagnostic accuracy or comparative effectiveness with human readers using this specific device.

    The "Non-Clinical Test summary" (Page 9, Section 7) mentions:

    • "A total of 30 clinical image samples, including elbows, hands, knees, ankles, and feet, were reviewed by qualified clinicians and determined to be of good quality and clinically useful." This sounds like an image quality assessment, not a performance study of an AI algorithm.
    • "Software validation and risk analysis was performed." This refers to internal software quality assurance processes.

    Therefore, many of the requested points related to AI performance, ground truth, expert adjudication, and MRMC studies cannot be answered from the provided text, as the device described is a hardware X-ray system, not an AI diagnostic algorithm.

    However, I can still extract information based on the typical requirements for a 510(k) clearance for a hardware device like an X-ray system. The "acceptance criteria" here would typically relate to meeting performance standards for X-ray output, safety, electrical compatibility, and image quality demonstrations, rather than diagnostic accuracy of an AI algorithm.


    Based on the provided FDA 510(k) clearance letter, here's an analysis tailored to what is present and what is absent:

    Summary of Device Performance and Acceptance Criteria (as implied for a hardware X-ray system)

    The acceptance criteria for a portable X-ray system like the HnX-P1/HnX-PB are primarily focused on safety, technical performance, and image quality adequacy for diagnostic use, rather than the diagnostic accuracy of an AI. The studies proving the device meets these criteria are primarily non-clinical tests and demonstrations of substantial equivalence to a predicate device.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria Category (Implied for X-ray Hardware)Specific Criteria (Derived from document)Reported Device Performance (as stated or implied)
    Safety and Electrical Standards ComplianceIEC 60601-1 (Basic Safety & Essential Performance)Complies (Laboratory Testing Performed)
    IEC 60601-1-2 (EMC)Complies (Laboratory Testing Performed)
    IEC 60601-1-3 (Radiation Protection)Complies (Laboratory Testing Performed)
    IEC 60601-2-28 (X-ray Tube Assemblies)Complies (Laboratory Testing Performed)
    IEC 60601-2-54 (Radiography & Radioscopy)Complies (Laboratory Testing Performed)
    Software Quality & Risk ManagementIEC 62304 (Software Life Cycle)Complies (Laboratory Testing Performed, Software Validation & Risk Analysis Performed)
    IEC 62366 (Usability Engineering)Complies (Laboratory Testing Performed)
    ISO 14971 (Risk Management)Complies (Laboratory Testing Performed)
    CybersecurityFDA Guidance (Sept 27, 2023) CompliantComplies (Review indicated)
    Labeling ComplianceCFR Part 801Complies (Review indicated)
    Image Quality for Diagnostic UseImages "good quality and clinically useful"30 clinical image samples (extremities) reviewed by qualified clinicians and deemed "good quality and clinically useful"
    PMR Safety Performance StandardFDA Performance StandardComplies
    Substantial EquivalenceNo significant differences affecting intended use compared to predicate K182207Claimed and accepted by FDA, based on comparison of technical characteristics and indications for use.

    2. Sample size used for the test set and data provenance:

    • Test Set (for "Image Quality" evaluation): 30 clinical image samples.
    • Data Provenance: Not explicitly stated regarding country of origin or whether retrospective/prospective. However, the use of "clinical image samples" suggests real patient data, likely retrospective given the lack of a formal clinical study.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • For the "image quality" assessment of the 30 samples: "qualified clinicians" reviewed the images. The exact number of clinicians or their specific qualifications (e.g., "Radiologist with 10 years of experience") are not specified in this document.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    • Not applicable/Not specified for this type of hardware evaluation. The document implies a qualitative assessment ("determined to be of good quality and clinically useful") rather than a diagnostic performance adjudication.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No MRMC study was performed or required. The device is a portable X-ray system, not an AI diagnostic aid for human readers.
    • The document explicitly states: "Clinical studies were not performed." (Page 10, Section 8).

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This device is a hardware X-ray imager, not a standalone AI algorithm. It produces images, but does not autonomously interpret them.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    • For the "image quality" assessment, the "ground truth" was effectively the qualitative judgment of "qualified clinicians" that the images were "good quality and clinically useful." This isn't diagnostic "ground truth" (e.g., presence/absence of a disease).

    8. The sample size for the training set:

    • Not applicable. This document describes a hardware device, not an AI algorithm that requires a training set.

    9. How the ground truth for the training set was established:

    • Not applicable. As above, no AI training set is described or relevant to this hardware device clearance.

    In conclusion, the provided FDA 510(k) clearance letter details the regulatory review for a medical device hardware (portable X-ray system), not an AI or software as a medical device (SaMD) with diagnostic capabilities that underwent a performance study against specific diagnostic acceptance criteria. The "acceptance criteria" discussed are largely compliance with electrical, safety, and performance standards, and a qualitative assessment of image utility.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250597

    Validate with FDA (Live)

    Device Name
    REMEX Xcam6
    Manufacturer
    Date Cleared
    2025-07-31

    (153 days)

    Product Code
    Regulation Number
    892.1720
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    , 072NN
    SOUTH KOREA

    Re: K250597
    Trade/Device Name: REMEX Xcam6
    Regulation Number: 21 CFR 892.1720
    DEVICE

    Name: REMEX Xcam6
    Common Name: System, X-Ray, Mobile
    Regulation Number: 21 CFR 892.1720
    IL, USA)
    Name: TR90BH
    Common name: System, X-Ray, Mobile
    Regulation Number: 21 CFR 892.1720
    Subject Device) | TR90BH (K182207) | Comparison |
    |---|---|---|---|
    | Classification & Product code | 892.1720
    ; IZL | 892.1720; IZL | Same |
    | Intended Use | Portable X-ray Equipment REMEX Xcam6 is intended

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Portable X-ray Equipment REMEX Xcam6 is intended to be used in a hospital or clinic setting under the supervision of a qualified and trained clinician. This product is used as an x-ray source to produce diagnostic x-ray images of patient's extremities using an X-ray detector. It may be used in handheld or stand-mounted configurations for acquiring diagnostic radiographic images of extremities.

    The device is not intended for mammography.

    The REMEX Xcam6 is not intended to replace a stationary radiographic system, which may be required for full optimization of image quality and radiation exposure for different exam types.

    Device Description

    The REMEX Xcam6 is a handheld and portable general-purpose X-ray system intended for use by qualified and trained clinicians to obtain diagnostic radiographic images of patient's extremities.

    The REMEX Xcam6 serves as an X-ray source and is designed to be used in conjunction with a Flat Panel Detector (FPD), which is not included as part of the system. The FPD is connected to a computer equipped with imaging software that enables image acquisition, display, manipulation, storage, and transmission.

    The X-ray source is securely enclosed within the housing of the handheld unit, and the device does not come into direct contact with the patient during use.

    During imaging procedures, the patient is positioned appropriately—either sitting or lying down—and the X-ray receptor is aligned accordingly. The patient is instructed to remain still while the operator sets the exposure parameters and initiates the radiographic exposure.

    The operator has control over the following exposure parameters:

    1. Tube Voltage (kVp): Adjustable from 40 to 90 kVp, in 1 kV increments.
    2. Tube Current (mA): Adjustable from 2 to 6 mA, in 1 mA increments.
    3. Exposure Time: Adjustable from 0.06 to 2.00 seconds, in 0.01-second increments.
    AI/ML Overview

    The provided document outlines the FDA 510(k) clearance for the REMEX Xcam6, a portable X-ray equipment. While it confirms the device meets safety and performance standards for substantial equivalence to a predicate device, it does not provide explicit acceptance criteria in the form of specific performance metrics (e.g., sensitivity, specificity, accuracy) or detailed clinical study results typical for an AI/CADe device.

    The document primarily focuses on technical characteristics, electrical safety, image quality (bench testing), and software validation. The "Clinical Performance Testing" section is very limited and only states that a board-certified radiologist verified the images were suitable for diagnostic interpretation, without quantifiable results.

    Therefore, many of the requested details, especially those pertaining to a comparative effectiveness study involving AI assistance, multi-reader multi-case studies, or detailed AI performance metrics, are not available in the provided text as this is a traditional X-ray device clearance, not an AI/CADe device clearance.

    Below is an attempt to address the questions based only on the information available in the provided FDA 510(k) clearance letter. Missing information will be explicitly stated as "Not provided."


    Acceptance Criteria and Device Performance Study for REMEX Xcam6

    The REMEX Xcam6 is a mobile X-ray system, not an AI or CADe (Computer-Aided Detection/Diagnosis) device, as indicated by the product code "IZL" (Mobile x-ray system) and the lack of AI-specific claims. Therefore, the acceptance criteria and study detailed in the document focus on demonstrating substantial equivalence to a predicate conventional X-ray system through technical specifications, safety, and image quality for diagnostic interpretation by a human clinician, rather than on AI-driven performance metrics like sensitivity, specificity, or reader improvement.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document describes several non-clinical tests (electrical safety, EMC, image quality, dosimetry, software V&V) and a limited clinical test. The "acceptance criteria" for these tests are implicitly that the device performs "as intended" and is "as safe and effective as the predicate device," and that "all predefined acceptance criteria established in the test protocol" were met for bench testing. Specific, quantitative acceptance criteria for image quality beyond "suitable for diagnostic interpretation" are not explicitly stated for the clinical review.

    Acceptance Criteria Category/MetricReported Device Performance
    Electrical SafetyComplies with IEC 60601-1, IEC 60601-1-3, IEC 60601-1-6, IEC 60601-2-28, IEC 60601-2-54 standards.
    Electromagnetic Compatibility (EMC)Complies with IEC 60601-1-2 standard.
    Image Quality (Bench Testing)Met all predefined acceptance criteria established in the test protocol; image quality characteristics are substantially equivalent to the predicate device.
    Dosimetry (Bench Testing)Met all predefined acceptance criteria established in the test protocol; radiation dose characteristics are substantially equivalent to the predicate device.
    Software Verification & ValidationPerformed in accordance with IEC 62304:2006/A1:2015 for Class B software; Cybersecurity addressed per FDA guidance.
    Clinical Image QualityAcquired images were reviewed and assessed by a board-certified radiologist, who verified that the image quality was suitable for diagnostic interpretation.

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: Not explicitly provided. The documentation states "A limited clinical test was conducted." It does not specify the number of images or patients included in this test.
    • Data Provenance: Not provided (e.g., country of origin, retrospective or prospective).

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    • Number of Experts: "A board-certified radiologist" (singular) was stated to have reviewed and assessed the images.
    • Qualifications of Experts: "Board-certified radiologist." No specific experience level (e.g., years of experience) is mentioned.

    4. Adjudication Method for the Test Set

    • Adjudication Method: Not provided. Given only one radiologist was mentioned for clinical review, a formal multi-reader adjudication method (e.g., 2+1, 3+1) is unlikely to have been performed for this specific clinical assessment. The radiologist's assessment served as the verification.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    • MRMC Study: No. The provided information is for a traditional X-ray system, not an AI-assisted device. The clinical performance testing focused on verifying the image suitability for diagnostic interpretation by a single radiologist, not on human reader performance improvement with AI assistance.
    • Effect Size of Human Readers Improvement: Not applicable, as no AI assistance is mentioned or evaluated.

    6. If a Standalone Study (Algorithm Only Without Human-in-the-Loop Performance) was Done

    • Standalone Study: Not applicable. This device is a hardware X-ray system; it does not feature an AI algorithm that would have standalone performance. Its software controls the X-ray system's operation, not image interpretation.

    7. The Type of Ground Truth Used

    • Ground Truth Type: For the "limited clinical test," the "ground truth" for verifying image quality appears to be the subjective assessment and verification by a single "board-certified radiologist" that the images were "suitable for diagnostic interpretation."
    • For bench testing, phantoms were used, with "predefined acceptance criteria" as the ground truth.

    8. The Sample Size for the Training Set

    • Training Set Sample Size: Not applicable. This product is a physical X-ray machine. It does not utilize an AI model that requires a training set in the conventional sense. The software mentioned (IEC 62304 Class B) relates to the operational control of the device, not image analysis or AI interpretation.

    9. How the Ground Truth for the Training Set was Established

    • Ground Truth Establishment for Training Set: Not applicable, as there is no AI model or training set specified for this device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K243473

    Validate with FDA (Live)

    Date Cleared
    2025-07-29

    (263 days)

    Product Code
    Regulation Number
    892.1720
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Ultraportable
    Prorad Atlas Ultraportable Plus
    Regulation Number: 21 CFR 892.1720
    Name:** PRORAD ATLAS ULTRAPORTABLE
    PRORAD ATLAS ULTRAPORTABLE PLUS

    Regulation Number: 21 CFR 892.1720
    Medical Systems Private Limited | Remedi Co., Ltd. | Not applicable |
    | Regulation Number | 21 CFR 892.1720
    | 21 CFR 892.1720 | Identical |
    | Product Code | IZL | IZL | Identical |
    | Product Class | II | II |

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The PRORAD ATLAS ULTRAPORTABLE Digital X-ray system is intended to deliver high-quality, diagnostic radiographic images of the body extremities. It utilizes a portable X-ray unit, flat-panel detector and image acquisition software to produce clear digital images, enabling fast and accurate diagnosis. The portable X-ray unit is intended to be used only when stand/tripod mounted.

    The PRORAD ATLAS ULTRAPORTABLE X-ray digital system is predominantly employed in various settings, including health-care centres, temporary and emergency health centres (established, especially in pandemic circumstances), outreach and field interventions (such as mobile clinics/vans, screening campaigns, and home care), and tele-radiology solutions in remote areas.

    The primary users anticipated for the system include radiographers, radiological technologists, and medical professionals who are trained in safety, radiation protection, and image management.

    The PRORAD ATLAS ULTRAPORTABLE PLUS Digital X-ray system is intended to deliver high-quality, diagnostic radiographic images of the body extremities. It utilizes a portable X-ray Unit, flat-panel detector and real-time image processing using software to produce clear digital images, enabling fast and accurate diagnosis. The portable X-ray unit is intended to be used only when stand/tripod mounted.

    The PRORAD ATLAS ULTRAPORTABLE PLUS X-ray digital system is predominantly employed in various settings, including health-care centres, temporary and emergency health centres (established, especially in pandemic circumstances), outreach and field interventions (such as mobile clinics/vans, screening campaigns, and home care), and tele-radiology solutions in remote areas.

    The primary users anticipated for the system include radiographers, radiological technologists, and medical professionals who are trained in safety, radiation protection, and image management.

    Device Description

    The PRORAD ATLAS X-Ray system includes the ULTRAPORTABLE and ULTRAPORTABLE PLUS, which are portable diagnostic X-ray systems with fixed 70kV and 2mA tube current. These systems are intended to produce anatomical X-rays of the body extremities in both pediatric and adult patients. The PRORAD ATLAS X-Ray system was designed, developed, and manufactured by Prognosys Medical Systems Private Limited. The model numbers are listed below.

    Model NumberModel NameModel Description
    A86-ATL-0001PRORAD ATLAS ULTRAPORTABLEThese are ultraportable X-ray systems designed to generate diagnostic, high-quality X-ray images
    A87-ATL-0001The PRORAD ATLAS ULTRAPORTABLE PLUS

    The PRORAD ATLAS X-ray system is a sophisticated, battery-powered X-ray generator offered in two versions: PRORAD ATLAS ULTRAPORTABLE and ULTRAPORTABLE PLUS. The main distinction between these models lies in their exposure time ranges and target anatomical areas. The ULTRAPORTABLE model provides exposure times ranging from 0.01 to 1.30 seconds, while the ULTRAPORTABLE PLUS model offers an extended exposure range of 0.01 to 2.5 seconds. Both models share identical internal components, software, algorithms, and operational features and are intended for imaging body extremities. The system includes a high-voltage tank with an X-ray tube mounted on an adjustable tripod stand, allowing users to adjust the height to the specific imaging area. Exposure parameters are configured through the X-ray generator's graphical user interface (GUI). After setting the parameters and positioning the patient on the detector, the X-ray is activated via an exposure switch. The detector captures the radiation, converts it into a digital signal, and transmits the data wirelessly to a computer equipped with compatible software. The images are processed and displayed on the computer for diagnostic review. The PRORAD ATLAS system is compatible with several 510(k)-cleared detectors and their associated software, listed below in Table 1. Prognosys includes one detector and its pre-configured software in the package, depending on availability. Fully battery-operated, the system does not support direct power connection but can seamlessly integrate with multiple detectors and compatible software as part of the package.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and supporting documentation for the PRORAD ATLAS ULTRAPORTABLE X-Ray Systems do not include acceptance criteria or a detailed study that proves the device meets specific performance criteria beyond general safety and effectiveness.

    The document primarily focuses on demonstrating substantial equivalence to a predicate device (Remex KA6, K212144) rather than presenting a performance study with defined acceptance criteria. The "Summary of non-clinical testing" lists a series of international standards (IEC, ISO) and FDA guidance documents that were followed for design control, risk management, verification, and validation. The "Summary of clinical testing" mentions that clinical images were collected and reviewed by a qualified radiologist, confirming they are "clinically acceptable." However, specific quantitative acceptance criteria for image quality, diagnostic accuracy, or other performance metrics, along with the study design and results against those criteria, are not detailed in this document.

    Therefore, I cannot provide a table of acceptance criteria and reported device performance, nor can I provide information about sample size, expert details, adjudication methods, MRMC studies, standalone performance, or training set specifics, as this information is not present in the provided text.

    Based on the available text, here's what can be extracted:

    • Overall Conclusion: The device is deemed "safe and effective when the device is used as labelled and is substantially equivalent to the predicate device."

    Here's a breakdown of why the requested information cannot be fully provided based on the input:

    1. A table of acceptance criteria and the reported device performance: This information is not explicitly stated in the document. The document confirms that "Validation of PRORAD ATLAS X-Ray System has demonstrated that the system enables optimal and quality imaging of anatomical structures" and that clinical images are "clinically acceptable," but no specific quantitative criteria or performance metrics are given.

    2. Sample size used for the test set and the data provenance: The document states that "Clinical images of body extremities were collected from patients of varying ages, weights, and BMIs." However, the exact sample size and the provenance (e.g., country of origin, retrospective/prospective nature) of this clinical image test set are not specified.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: The document mentions that images were "reviewed by a qualified radiologist." It does not specify the number of radiologists or their specific qualifications (e.g., years of experience, board certification).

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set: No adjudication method for the clinical image review is described.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: An MRMC study is not mentioned. The device described is an X-ray system, not an AI software to assist human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: This is not applicable as the device is an X-ray system, not an algorithm, and it's intended to be used by trained medical professionals.

    7. The type of ground truth used: The ground truth for the clinical images appears to be "clinical acceptability" as determined by a "qualified radiologist." This aligns with "expert consensus" in a general sense, but no more objective ground truth (e.g., pathology, outcomes data) is mentioned for the image quality assessment.

    8. The sample size for the training set: The document does not mention a training set, as it describes an X-ray hardware system, not an AI-driven software that requires a training set.

    9. How the ground truth for the training set was established: Not applicable, as no training set is mentioned.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 20