    Why did this record match?
    510k Summary Text (Full-text Search) :

    Shanghai, 200122 CHN

    Re: K260319
    Trade/Device Name: K5 wheelchair
    Regulation Number: 21 CFR 890.3850
    Shanghai, 200122 CHN

    Re: K260319
    Trade/Device Name: K5 wheelchair
    Regulation Number: 21 CFR 890.3850
    Classification Name: Mechanical Wheelchair
    Regulatory Class: I
    Product code: IOR
    Regulation Number: 890.3850

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The K5 Wheelchair is to provide mobility to persons limited to a sitting position.

    Device Description

    The K5 series is a mechanical wheelchair which is a manually operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position. It can be folded for transport by bring the two sides together. The manual wheelchair incorporates a main frame, a seat, two adjustable footrests, 2 removable footrests and four wheels. The larger rear wheels have hand rims of slightly smaller diameter projecting just beyond the tire. These allows the user to manoeuvre the chair by pushing them on without requiring them to grasp the tires. The manual wheelchairs have brakes that bear on the tires of the rear wheels and two push handles at the upper rear of the frame to allow for manual propulsion by an assistant.

    Main Components:
    Main frame, back upholstery, seat upholstery, handgrip, armrest, front wheel, rear wheel, hand rim, crossbar, footplates, brake, leg rest.

    The device can be operated indoors, or outdoors on dry, level surfaces composed of concrete, blacktop, or asphalt under normal driving conditions.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253632

    Validate with FDA (Live)

    Date Cleared
    2026-01-29

    (71 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    21 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    200122
    China

    Re: K253632
    Trade/Device Name: Manual Wheelchair (W50)
    Regulation Number: 21 CFR 890.3850
    Name | Mechanical wheelchair |
    | Classification Name | Wheelchair, Mechanical |
    | Regulation Number | 890.3850

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The manual wheelchair is to provide mobility to persons limited to a sitting position.

    Device Description

    A wheelchair is a chair with wheels, designed to be a replacement for walking, where it is propelled by the seated occupant turning the rear wheels by hand. There are also handles behind the seat for someone else to do the pushing. The device is intended for adults only.

    W50 is a mechanical wheelchair including four wheels, a steel frame cover black paint and a textilene upholstery that is flame resistant. W50 has a physical dimension of 1130mm x 840mm x 950mm (depth x width x height) with the seat itself has a dimension of 525mm x590mm x 470mm (depth x width x height). The device has a weight capacity of 227 kilograms, and weighs about 24 kilograms. The color is dark black.

    Occupant mass group of the manual wheelchair belongs to III. Armrest is non flip back/non height adjustable. Rear axle is offset axle, quick release axle.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251886

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-01-12

    (206 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    2 - 12
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    68022

    Re: K251886
    Trade/Device Name: EmpowerRide NAVIGATOR
    Regulation Number: 21 CFR 890.3850
    Number | K251886 |
    | Product Code | IOR, LBE |
    | Device Classification | Class I |
    | Regulatory Number | 890.3850
    K171017 | K151492 | FDA assigns this unique number to every device. |
    | Regulation Number | 21 CFR 890.3850
    | 21 CFR 890.3850 | 21 CFR 890.3850 | 21 CFR 890.3850 | Identical.
    Convaid Trekker (K140416) and similar predicate devices (K171017 and K151492) cleared under 21 CFR 890.3850

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EmpowerRide NAVIGATOR is a manual wheelchair; it is intended to provide mobility to children with disabilities who are partially or permanently non-ambulatory and limited to a sitting position.

    Device Description

    The EmpowerRide NAVIGATOR is a manual pediatric wheelchair intended to provide mobility to children with disabilities who are partially or permanently non-ambulatory and limited to a seated position.

    It is designed for caregiver propulsion and is suitable for everyday use in indoor and outdoor environments with flat, firm terrain. The device includes modular adaptive seating and postural supports to meet the therapeutic and mobility needs of pediatric users with neuromuscular, developmental, or orthopedic conditions.

    The NAVIGATOR may be used under the supervision of a healthcare provider or selected independently by caregivers for non-complex pediatric mobility needs. The device has been tested and meets the applicable performance and safety requirements of RESNA WC-1:2019 and ISO 7176 standards for manual wheelchairs.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252825

    Validate with FDA (Live)

    Date Cleared
    2025-12-05

    (91 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    22 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    China

    Re: K252825
    Trade/Device Name: Manual Wheelchair (Model W45)
    Regulation Number: 21 CFR 890.3850
    Classification Name: Mechanical Wheelchair
    Regulatory Class: I
    Product code: IOR
    Regulation Number: 890.3850
    Wheelchair | -- |
    | Classification | Class I | Class I | Same |
    | Classification regulation | 21 CFR 890.3850
    | 21 CFR 890.3850 | Same |
    | Product code | IOR | IOR | Same |
    | Indications for use | The W45 Manual

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The W45 Manual Wheelchair is to provide mobility to persons limited to a sitting position.

    Device Description

    The W45 Manual Wheelchair is a chair with wheels, designed to be a replacement for walking, where it is propelled by a caregiver using the rear push handles. The device is intended for adults only (age ≥22 years). W45 is a mechanical wheelchair including four wheels, features an aluminum frame, polypropylene hand grip and foot pedals, and a nylon upholstery that is flame resistant. W45 has a physical dimension of 1010mm × 610mm × 920mm (overall length × overall width × handgrip height) with the seat itself has a dimension of 470mm × 457mm × 449mm (effective depth× effective width × height at front edge). The device has a weight capacity of 115 kilograms, and weighs about 12 kilograms. The armrest is non flip back/non height adjustable. Rear axle is offset axle, quick release axle. The device features hand brake levers on the rear push handles, with a squeeze-locking mechanism that functions as a parking brake.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252828

    Validate with FDA (Live)

    Date Cleared
    2025-12-05

    (91 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    22 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K252828**
    Trade/Device Name: Manual Wheelchair (Model W47)
    Regulation Number: 21 CFR 890.3850
    ** Mechanical Wheelchair
    Regulatory Class: I
    Product code: IOR
    Regulation Number: 890.3850

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The W47 Manual Wheelchair is to provide mobility to persons limited to a sitting position.

    Device Description

    A wheelchair is a chair with wheels, designed to be a replacement for walking, where it is propelled by the seated occupant turning the rear wheels by hand. There are also handles behind the seat for someone else to do the pushing. W47 is a mechanical wheelchair including four wheels, a steel frame and a seat and back upholstery that is flame resistant. W47 has a physical dimension of 1340mm × 690mm × 950mm (overall length × overall width × handgrip height) with the seat itself has a dimension of 580mm × 450mm × 465mm (effective depth × width × seat height at front edge). The device has a weight capacity of 136 kilograms, and weighs about 24 kilograms. The armrest is non flip back/non height adjustable. Rear axle is offset axle, quick release axle. The device features hand brake levers on the rear push handles as well as wheel locks (parking brakes).

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252687

    Validate with FDA (Live)

    Date Cleared
    2025-11-21

    (87 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Trade/Device Name: Manual Wheelchair (HM305-Air1, HM305-Air2)
    Regulation Number: 21 CFR 890.3850
    Trade/Device Name: Manual Wheelchair (HM305-Air1, HM305-Air2)
    Regulation Number: 21 CFR 890.3850

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The manual wheelchair is to provide mobility to persons limited to a sitting position.

    Device Description

    Manual Wheelchair (HM305-Air1, HM305-Air2)

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250576

    Validate with FDA (Live)

    Date Cleared
    2025-11-04

    (250 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Thailand

    Re: K250576
    Trade/Device Name: Flexx Junior (FLX-J00, FLX-J50)
    Regulation Number: 21 CFR 890.3850
    Mechanical |
    | Device Classification | Class I |
    | Classification Product Code | IOR |
    | Regulation number | 890.3850
    Mechanical |
    | Device Classification | Class I |
    | Classification Product Code | IOR |
    | Regulation Number | 890.3850
    Classification | Class 1 | Class I |
    | Classification Product Code | IOR | IOR |
    | Regulation Number | 890.3850
    | 890.3850 |
    | Intended Use | Flexx Junior manual wheelchair is intended to provide mobility to pediatrics

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Flexx Junior manual wheelchair is intended to provide mobility to pediatrics limited to a seating position.

    Device Description

    The Flexx Junior is a pediatric manual wheelchair designed to provide mobility, comfort, and postural support for children with mobility limitations. Available in self-propelled (Model FLX-J00 with fixed backrest, Model FLX-J50 with foldable backrest) and transit configurations, it is primarily intended for indoor use with limited outdoor capability on smooth surfaces. The wheelchair offers both self-propulsion with 20" or 22" quick-release rear wheels and transit propulsion with 14" quick-release rear wheels. The device supports users weighing up to (165 lbs) 75 kg and is engineered for growth and incorporates adjustable features to accommodate growth.

    The Flexx Junior is constructed with a lightweight aluminum folding frame, ensuring durability and ease of transport. Its compact folded dimensions facilitate storage and transport in vehicles. The device offers adjustable seat width, seat depth, and backrest height to ensure a customized fit as the child grows. The wheelchair's front caster wheel allows better maneuverability, while larger rear wheels improve stability and ease of movement, ensuring the device's structural integrity and safety. The wheelchair's compact design ensures maneuverability in tight spaces. The total width allows for easy navigation through doorways and confined spaces, and the overall height offers appropriate support and comfort. Easy to Transport and Its folding frame is built from aluminum, making it lightweight yet durable ensuring longevity. Despite its robust design, it remains lightweight and can be folded into a compact size for easy transport.

    The handrim offers optimal leverage for self-propulsion. The wheelchair's turning radius ensures easy movement in confined spaces, with the pivot width supporting safe turning. Static stability defines the wheelchair's ability to maintain balance on slopes, ensuring safety on inclines and uneven terrains. The angular ranges are consistent with predicate devices and do not raise new questions of safety or effectiveness

    The seat and backrest angles provide ergonomic support, promoting good posture and comfort. Adjustable seat depth and width cater to various body types, while the seat surface height facilitates ease of transfer. The wheelchair includes adjustable footrest and armrest distances, enhancing user comfort and posture.

    Primarily designed for indoor environments but is not suitable for rough terrains.

    The Flexx Junior is tested and compliant with ISO 7176-19 standards, making it suitable as a seat in a motor vehicle. Safety features include push-to-lock brakes, standard anti-tippers, and optional accessories such as a table tray, IV pole holder, and oxygen tank holder. Flip-up, height-adjustable armrests and quick-release axles enhance usability. Engineered to support children throughout their formative years, it provides the perfect balance of flexibility, safety, and comfort as they grow.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252517

    Validate with FDA (Live)

    Date Cleared
    2025-10-03

    (53 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    China

    Re: K252517
    Trade/Device Name: Manual Wheelchair (SYIV100A008)
    Regulation Number: 21 CFR 890.3850

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The manual wheelchair is to provide mobility to persons limited to a sitting position.

    Device Description

    Not Found

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K241374

    Validate with FDA (Live)

    Date Cleared
    2025-02-28

    (289 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Name: Manual Wheelchair (Models: S002, S004, S005, S006, S007, S008, S009) Regulation Number: 21 CFR 890.3850
    Classification Name: Wheelchair, Mechanical Classification: Class I Product code: IOR Regulation Number: 21 CFR 890.3850

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Manual Wheelchair is to provide mobility to persons limited to a sitting position.

    Device Description

    The S002, S004, S005, S006, S007, S008, S009 series are mechanical wheelchairs which are a manually operated devices with wheels that are intended for medical purposes to provide mobility to persons restricted to a sitting position. It can be folded for transport by bring the two sides together. The manual wheelchair incorporates a main frame, a seat, two adjustable footrests and four wheels. The larger rear wheels have hand rims of slightly smaller diameter projecting just beyond the tire. These allows the user to manoeuvre the chair by pushing them on without requiring them to grasp the tires. The manual wheelchairs have brakes that bear on the tires of the rear wheels and two push handles at the upper rear of the frame to allow for manual propulsion by an assistant.

    Main Components: Main frame, Backrest, Seat cushion, handgrip, front wheel, rear wheel, hand rim, crossbar, footrests, brake, Anti-tipper, Seat belt.

    The device can be operated indoors, or outdoors on dry, level surfaces composed of concrete, blacktop, or asphalt under normal driving conditions.

    AI/ML Overview

    This FDA 510(k) summary describes a Manual Wheelchair (Models: S002, S004, S005, S006, S007, S008, S009) and its substantial equivalence to a predicate device (K232230). The information provided is for a physical medical device, not an AI/software device. Therefore, many of the requested categories related to AI/software performance criteria (such as sample sizes for test/training sets, data provenance, expert ground truth, adjudication methods, MRMC studies, or standalone algorithm performance) are not applicable to this document.

    However, I can extract the acceptance criteria related to the physical device's performance and the study details that demonstrate it meets those criteria.

    1. Table of acceptance criteria and the reported device performance:

    Acceptance Criteria (Standard Compliance)Reported Device Performance
    Mechanical Performance Standards:Compliance Demonstrated:
    ISO 7176-1:2014 (Static stability)Complies
    ISO 7176-3:2012 (Effectiveness of brakes)Complies
    ISO 7176-5:2008 (Overall dimensions, mass and maneuvering space)Complies
    ISO 7176-7:1998 (Measurement of seating and wheel dimensions)Complies
    ISO 7176-8:2014 (Static, impact and fatigue strengths)Complies
    ISO 7176-11:2012 (Test dummies)Complies
    ISO 7176-13:1989 (Coefficient of friction of test surfaces)Complies
    ISO 7176-15:1996 (Information disclosure, documentation and labeling)Complies
    ISO 16840-10:2021 (Resistance to ignition of postural support devices)Complies
    ISO 7176-22:2014 (Set-up procedures)Complies
    Biocompatibility Standards:Compliance Demonstrated:
    ISO 10993-1 (General biological evaluation)Complies
    ISO 10993-5:2009 (Cytotoxicity)Non-cytotoxic
    ISO 10993-10:2021 (Sensitization)Non-sensitizing
    ISO 10993-23:2021 (Irritation)Non-irritating

    2. Sample size used for the test set and the data provenance:

    • Sample size: Not specified in the document. For physical device performance testing, samples are typically a representative number of units, but specific numbers are not usually detailed in a 510(k) summary unless a specific statistical power is claimed for a particular test.
    • Data provenance: The tests were conducted by the applicant, Anhui JBH Medical Apparatus Co., Ltd, in China (No.116 QiCang Road Industrial District MingGuang Chuzhou,Anhui, China). The data is retrospective in the sense that the tests were performed on finished devices to demonstrate compliance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    This information is not applicable. For physical device performance, "ground truth" is established through standardized testing procedures and objective measurements as defined by the referenced ISO standards, not through expert consensus on interpretation.

    4. Adjudication method for the test set:

    Not applicable. Physical device performance is determined by meeting objective criteria defined in the ISO standards, not by an adjudication process as used in clinical or imaging studies.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable. This is a physical medical device, not an AI/software device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Not applicable. This is a physical medical device, not an AI/software device.

    7. The type of ground truth used:

    The "ground truth" for the device's performance is established by its adherence to the technical specifications and performance limits defined within the cited international ISO standards (e.g., ISO 7176 series for wheelchairs and ISO 10993 series for biocompatibility). This is essentially objective measurement against predefined engineering and biocompatibility standards.

    8. The sample size for the training set:

    Not applicable. This is a physical medical device, not an AI/software device that requires a training set.

    9. How the ground truth for the training set was established:

    Not applicable. This is a physical medical device, not an AI/software device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243111

    Validate with FDA (Live)

    Date Cleared
    2025-01-10

    (102 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    California 92833

    Re: K243111

    Trade/Device Name: Bowhead ERA Wheelchairs Regulation Number: 21 CFR 890.3850
    Wheelchair |
    | Classification Name: | Wheelchair, Mechanical |
    | Regulation Number: | 890.3850

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Bowhead ERA Wheelchairs are manually operated wheelchairs intended to be used as a means of mobility for individuals restricted to a sitting position.

    Device Description

    The Bowhead ERA Wheelchairs are composite based mechanical, manually operated, wheelchairs intended to be used as a means of mobility for adults restricted to a sitting position. Using the push ring on the rear wheels, users can self-propel themselves forward or backwards. The chairs are designed for riding over various indoor and outdoor surfaces. The Bowhead ERA Wheelchairs include four (4) mechanical wheelchair models with each model containing slightly different design features. Each wheelchair is provided assembled with a sling backrest, seat, seat post, brakes, frame, rear wheels, and casters. The overall length, width and height, backrest angle, COG, wheelbase, and seat width and height are adjustable ensuring comfort for the patient.

    AI/ML Overview

    The provided text is a 510(k) summary for the Bowhead ERA Wheelchairs. This type of submission focuses on demonstrating substantial equivalence to a predicate device, rather than proving the device meets specific performance acceptance criteria through clinical studies. Therefore, the information you've requested regarding acceptance criteria, a study proving the device meets them, sample sizes for test and training sets, expert qualifications, adjudication methods, MRMC studies, standalone performance, and ground truth types and establishment is not available in this document.

    The document details a comparison of technological characteristics between the Bowhead ERA Wheelchairs and two predicate devices (APEX Manual Wheelchair and Panthera X) and lists non-clinical tests performed to support substantial equivalence. These non-clinical tests are against established standards for wheelchairs, not against a specific set of acceptance criteria derived from a clinical study for this particular device.

    Here's a breakdown of what is available in the document related to performance:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document does not present a table of specific acceptance criteria for the device's performance in the sense of clinical accuracy or diagnostic capabilities. Instead, it lists the non-clinical tests performed and concludes that the device is "as safe and effective as the predicate devices" based on these tests.

    Acceptance Criteria (Implied by Standards)Reported Device Performance (Summary)
    Mechanical Performance and Safety
    Static stabilityMet RESNA WC-1:2019, Section 1
    Effectiveness of brakesMet RESNA WC-1:2019, Section 3
    Overall dimensions, mass, maneuvering spaceMet RESNA WC-1:2019, Section 5
    Seating and wheel dimensionsMet RESNA WC-1:2019, Section 7
    Static, impact, and fatigue strengthsMet RESNA WC-1:2019, Section 8
    Coefficient of friction of test surfacesMet RESNA WC-1:2019, Section 13
    FlammabilityFlammability testing performed (implies compliance with relevant standards)

    2. Sample Size Used for the Test Set and Data Provenance:

    • Sample Size: Not applicable. The "tests" mentioned are non-clinical engineering and performance tests on the device itself, not clinical trials with human subjects.
    • Data Provenance: Not applicable. The data comes from physical testing of the device, not from human data.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    • Not applicable, as this is related to clinical evaluation and ground truth for diagnostic accuracy, which is not the subject of this 510(k) summary. The "tests" are against engineering standards.

    4. Adjudication Method for the Test Set:

    • Not applicable for the same reasons as above.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

    • No. MRMC studies are typically for medical imaging or diagnostic devices where human interpretation is involved. This device is a mechanical wheelchair.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

    • Not applicable. This device does not involve algorithms or AI.

    7. The Type of Ground Truth Used:

    • Not applicable in the context of clinical ground truth. The "ground truth" for the non-clinical tests is adherence to the specified RESNA WC-1:2019 standards and flammability requirements.

    8. The Sample Size for the Training Set:

    • Not applicable. There is no AI or machine learning model being trained for this device.

    9. How the Ground Truth for the Training Set Was Established:

    • Not applicable.

    In summary, the provided document is for a mechanical wheelchair, which falls under a different regulatory pathway (510(k) for substantial equivalence to a predicate device) than, for example, an AI/ML-driven diagnostic tool. Therefore, the types of clinical and performance studies you're asking about are not relevant to this specific device submission. The "study" proving the device meets criteria is a series of non-clinical, engineering-based performance tests against recognized standards.