Found 124 results

510(k) Data Aggregation

    K Number
    K251353

    Validate with FDA (Live)

    Device Name
    Eyer 2
    Date Cleared
    2026-01-16

    (261 days)

    Product Code
    Regulation Number
    886.1120
    Age Range
    N/A
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    São Paulo 13562-405
    Brazil

    Re: K251353
    Trade/Device Name: Eyer 2
    Regulation Number: 21 CFR 886.1120
    Common/usual name:** Ophthalmic camera

    • Classification name: camera, ophthalmic, ac-powered (21 CFR 886.1120
      Common/usual name:** Ophthalmic camera
    • Classification name: camera, ophthalmic, ac-powered (21 CFR 886.1120
      Ophthalmic camera | Class II21 CFR 886.1120Ophthalmic camera | Class II21 CFR 886.1120
      Ophthalmic camera | Class II21 CFR 886.1120Ophthalmic cameraand21 CFR 886.1850<br
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description

    The Eyer 2 is accompanied by accessories: frontal module for the ocular surface (1pc), dock station (charging station) (1pc), eye cap (1pc), lens protector (1 pc), storage case (1 pc), cleaning cloth (1 pc), allen wrench (1 pc), quick start guide (1 pc), welcome card (1 pc), shipping box (1 pc), power supply (1 pc), slit-lamp adapter (1 pc), silica gel bags (2 pcs).

    Eyer 2 is designed for use in a medical environment by healthcare professionals. Captured images and videos are used for documentation and consultation. The images and videos are securely stored in an internal smartphone application database.

    For the retinal function, the Eyer 2 is designed for non-mydriatic fundus imaging. In non-mydriatic imaging, no mydriasis is needed because infrared light is used for targeting the fundus and white light is flashed when an image is taken. The pupil does not respond to the infrared light so examination is convenient for the patient. With small pupils, it is recommended to use mydriatic drops. Eyer 2 has fixation targets for the patient to fixate on during imaging. The middle fixation target provides a macula-center image. It is possible to fix the optical disc in the center by selecting the appropriate point.

    For the ocular surface and surrounding areas function, Eyer 2 has an ocular surface module with white, blue, and infrared light sources for imaging the eye surface and surrounding areas; in this configuration, the device does not make contact with the patient.

    The transfer of images to a PC is carried out via DICOM, DICOMWEB, FTPS, or local folder connections, with the client responsible for the connection and subsequent storage.

    The Eyer 2 energy comes from the smartphone that has a rechargeable Li-Ion battery and is charged when the device is docked on the charge station, which is connected to the mains by a power supply cable.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252120

    Validate with FDA (Live)

    Date Cleared
    2025-12-12

    (158 days)

    Product Code
    Regulation Number
    886.1120
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K252120**
    Trade/Device Name: Fundus On Phone Non Mydriatic (FOP NM-10)
    Regulation Number: 21 CFR 886.1120
    Common Name** | Ophthalmic Camera |
    | Classification Name | Camera, Ophthalmic, AC powered (21 CFR 886.1120
    Regulation Name | Ophthalmic Camera | Ophthalmic Camera | Ophthalmic Camera |
    | 6. | Regulation Number | 886.1120
    | 886.1120 | 886.1120 |
    | 7. | Class | Class II | Class II | Class II |
    | 8. | Indications for use |

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    FOP NM-10 is an ophthalmic non-mydriatic digital camera using iPhone SE3 which captures images of the fundus of the human eye and surface as well as surrounding areas of the human eye.

    Device Description

    The FOP NM-10 is designed for imaging of the fundus and surface as well as surrounding area of the human eye, in a compact, portable format, with an inherent simplicity built in its operation and use. The application software (Remidio FOP) is loaded on top of the iOS operating system to enable the user to view, save, archive and retrieve the captured images of fundus and surface area of the human eye. It is a compact, battery-operated device that enables high-quality fundus photography without requiring pupil dilation. The device can be used in Hospitals and Ophthalmic clinics. The FOP NM-10 incorporates a 40° field of view (FOV) optical system optimized for high-resolution retinal imaging. The device employs infrared and white LED illumination to achieve adequate retinal illumination without causing discomfort to the patient. The device is built on a modular smartphone-based design, ensuring portability and ease of operation. The Remidio FOP app enables wireless control of illumination intensity, focus adjustments, capturing the images in Auto and manual modes, saving, editing and archiving images.

    Physical Specifications

    • a) Field of View: 40° (for a minimum pupil size of 3mm)
    • b) Material: ABS, Silicone Rubber
    • c) Diopter Correction: -16D to +16D
    • d) Working Distance: 33mm

    Output and Performance Characteristics

    • a) Illumination (Light Source): Infrared LED and Cool White LED
    • b) Camera Resolution: 64 line pairs per millimeter (lp/mm) (at the center)
    • c) ISO Range: ISO 200 and 400
    • d) Focus Adjustment: Manual and Tap to Focus
    • e) Internal Fixation: 8 fixation points
    • f) Operating temperature: 10° to 40°C
    • g) Relative Humidity: 10% to 85%
    • h) Atmospheric Pressure: 750 to 1060 hpa
    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250770

    Validate with FDA (Live)

    Date Cleared
    2025-09-04

    (175 days)

    Product Code
    Regulation Number
    886.1120
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    2P5
    Canada

    Re: K250770
    Trade/Device Name: Optina-4C (MHRC-C1N)
    Regulation Number: 21 CFR 886.1120
    COMMON NAME* | Fundus camera |
    | CLASSIFICATION NAME | Camera, Ophthalmic, Ac-Powered (21 CFR 886.1120
    | Class II |
    | PREDICATE DEVICES | MHRC-C1N (K231230)Camera, Ophthalmic, Ac-Powered (21 CFR 886.1120

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Optina-4C™ is a non-contact, high resolution digital imaging device which is suitable for photographing, displaying, storing, and transferring images of the retina. The Optina-4C is indicated for the viewing of the posterior segment of the eye at multiple wavelengths (colors) under mydriatic conditions.

    Images are intended to aid clinicians in the detection, diagnosis, and management of ocular health and disease.

    Device Description

    The Optina-4C™ (MHRC-C1N) is a non-contact mydriatic retinal camera (also called a fundus camera) designed to provide eye care professionals with a series of images of the retina obtained at specific wavelengths (colors). The Optina-4C processes images using algorithms that take advantage of the spectral information to produce 2D en face images of the retina as an aid to clinicians in the diagnosis of age-related macular degeneration (AMD), retinal pigment epithelium (RPE) disruptions and lesions, retinopathies, and other retinal diseases.

    Utilizing Hyperspectral Imaging (HSI) technology, the Optina-4C captures a series of 92 high-resolution images at precise 5 nm wavelength increments across the visible and near-infrared (NIR) spectrum on a ~31° field-of-view. Image acquisition takes under two seconds, with only 0.92 seconds of light exposure time. During this time, the camera scans through all wavelengths from 905 to 450 nm, spending 10 milliseconds per 5 nm step.

    The Optina-4C processes the images to provide spectrally calibrated, normalized, and registered images in a structured Hyperspectral Cube format for scroll-through viewing. The spectral resolution supports visualization and differentiation of drusenoid deposit types, as well as high contrast viewing of the retinal chromophores hemoglobin, melanin, and carotenoids (combination of lutein and zeaxanthin). Images can be viewed, stored or transferred in their native .h5 format, or as DICOM or PNG formats. Optina-4C images offer sharp, vivid, high-contrast coronal views of the posterior segment of the eye for clinical assessment and evaluation by eye care professionals.

    The HSI NormReg Cube is a processed data set of 91 hyperspectral images that have undergone intensity normalization and spatial registration. Normalization corrects for the non-uniform illumination profile of the imaging system and the spectral sensitivity of the camera, while registration compensates for intra-scan eye movement to ensure consistent alignment across frames. The result is a hyperspectral image cube with enhanced spatial and spectral fidelity, referred to as the HIS-NormReg Cube.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K243600

    Validate with FDA (Live)

    Date Cleared
    2025-08-14

    (266 days)

    Product Code
    Regulation Number
    886.1120
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K243600
    Trade/Device Name: 3nethra neo HD FA; 3nethra neo HD
    Regulation Number: 21 CFR 886.1120
    Code** | HKI |
    | Classification Name | Camera, Ophthalmic, Ac-powered |
    | Regulation Number | 886.1120

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    3nethra neo HD FA:

    3nethra neo HD FA is used as a wide-field retinal imaging digital camera for photo documentation of ocular diseases that manifest in infants. The device acquires only images and does not provide any pathological analysis or diagnosis for treatment.

    3nethra neo HD:

    3nethra neo HD is used as a wide-field retinal imaging digital camera for photo documentation of ocular diseases that manifest in infants. The device acquires only images and does not provide any pathological analysis or diagnosis for treatment.

    Device Description

    The 3nethra neo-HD FA is a handheld wide-angle fundus imaging system for neonatal screening. It is designed to acquire, display, store and transmit images of the posterior and anterior surfaces of human eye. The images assist clinicians in the evaluation and documentation of visual health in retinopathy of prematurity (ROP) and other problems. It operates in contact with the cornea of the eye under test. 3nethra neo HD FA uses continuous white light for operation and hence need pupil dilation. It also equipped with blue light source and green filters for fundus fluorescein angiography (FFA).

    The 3nethra neo-HD is a handheld wide-angle fundus imaging system for neonatal screening. It is designed to acquire, display, store and transmit images of the posterior and anterior surfaces of human eye. The images assist clinicians in the evaluation and documentation of visual health in retinopathy of prematurity (ROP) and other problems. It operates in contact with the cornea of the eye under test. 3nethra neo HD uses continuous white light for operation and hence need pupil dilation. The 3nethra neo HD is a lower end variant of the 3nethra neo HD FA without the Fluorescein Angiography feature.

    AI/ML Overview

    The provided 510(k) clearance letter and summary describe the acceptance criteria and a study to prove the device's performance. Here's a breakdown of the information requested:

    The device in question, 3nethra neo HD FA and 3nethra neo HD, are ophthalmic cameras intended for wide-field retinal imaging and photo documentation of ocular diseases in infants. They acquire images only and do not provide pathological analysis or diagnosis.


    Acceptance Criteria and Reported Device Performance

    The core acceptance criterion for this device, based on the provided document, is substantial equivalence to existing predicate devices, particularly in terms of image quality for the FA functionality. The study focuses on demonstrating that the fluorescent angiography (FA) images produced by the subject device are comparable in quality to those produced by a predicate device.

    Acceptance CriterionReported Device Performance
    Safety and EffectivenessDemonstrated through compliance with electrical safety (IEC 60601-1, IEC 60601-1-2) and light safety standards (ISO 15004-2, ANSI Z80.36) and comparable image quality to a cleared reference device for its intended use.
    Image Quality (for FA images, specifically for 3nethra neo HD FA)All study images produced by the 3nethra neo HD FA were found to be of comparable quality to those produced by the RetCam 3 reference device (K182263).

    Study Details

    The study described is a clinical observational study focused on image quality comparison.

    1. Sample size used for the test set and the data provenance:

      • The document states "of all study images," implying that all images collected within the clinical observational study were used for the comparison. However, the exact numerical sample size (number of images or patients) for the test set is not explicitly stated in the provided text.
      • Data Provenance: The document does not explicitly state the country of origin of the data or whether the study was retrospective or prospective. It is described as a "clinical observational study," which typically implies prospective data collection, but this is not confirmed.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • The document does not explicitly state the number of experts used or their specific qualifications (e.g., number of years of experience, specific certifications). It simply refers to the primary objective being to demonstrate comparability to a cleared reference device. The process of expert evaluation for "comparable quality" is not detailed.
    3. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

      • The document does not describe any specific adjudication method for evaluating image quality. It states that "all study images were found to be of comparable quality," but the process by which this finding was made (e.g., consensus, majority vote) is not provided.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, and if so, what was the effect size of how much human readers improve with AI vs. without AI assistance:

      • No, a multi-reader multi-case (MRMC) comparative effectiveness study was not performed or described in the provided text.
      • The device is described as an "Ophthalmic Camera" that "acquires only images and does not provide any pathological analysis or diagnosis for treatment." Therefore, there is no AI assistance component for human readers to be compared against. The study focused on assessing the image quality of the camera itself, not the impact of AI on human interpretation.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • This question is not applicable as the device is an imaging camera that acquires images for human interpretation, not an algorithm providing a standalone diagnostic or analytical output. The study assessed the quality of the images produced by the device.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • The ground truth for the "comparable image quality" assessment appears to be based on a clinical observational study comparing the subject device's images to those from a predicate device (RetCam 3). The implicit ground truth is the accepted, established quality of images from the predicate device.
      • The document does not mention pathology or outcomes data as a direct ground truth for image quality assessment in this context. The study aimed to show that the images themselves were of sufficient quality for their intended purpose (photo documentation) by comparing them to a cleared device.
    7. The sample size for the training set:

      • The document does not mention a training set. This is because the device is an imaging camera, not a machine learning or AI algorithm that requires a training set.
    8. How the ground truth for the training set was established:

      • This question is not applicable as there is no mention of a training set for this device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K250683

    Validate with FDA (Live)

    Date Cleared
    2025-04-30

    (55 days)

    Product Code
    Regulation Number
    886.1120
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Massachusetts 02180

    Re: K250683
    Trade/Device Name: Resolve Fundus Camera
    Regulation Number: 21 CFR 886.1120
    AC-powered Ophthalmic Camera

    Product Codes:

    HKI

    Device Classification

    Class II
    21 C.F.R. §886.1120

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Resolve Fundus Camera is an automatic eye-fundus camera intended for taking digital images of a human retina with or without the use of a mydriatic agent. It is intended for use as an aid to clinicians in the evaluation and diagnosis of ocular health.

    Device Description

    The Resolve Fundus Camera is a fundus camera designed to perform fundus observation, automatic pupil tracking and focusing, automatic image capture, and image preservation. The Resolve Fundus Camera is used for non-mydriatic observation and capturing of retinal images. The fundus camera employes three internal imaging systems to operate: illumination system, imaging system and observation system. Auto-alignment and auto-focus algorithms are used to automatically find and capture desired images of the fundus.

    The fundus camera features an internal, movable three-dimensional platform that allows for switching and precise positioning of the left and right eyes. The imaging process is done one eye at a time (left eye and then the right eye). The internal, moveable three-dimensional platform contains two types of cameras: a set of infrared cameras (one on each side) as well as one main camera.

    The observation system is used to detect and track the patient's pupil. Next, the illumination system determines the precise location of the ocular fundus after the pupil is located by the observation system. The system precisely finds the relationship between the position of the ocular fundus at different diopters, and the lens of the main camera.

    Once the location of the fundus is found, a charge-coupled device (CCD) automatically captures a still image of the fundus through the main camera. The autofocus system utilizes a beam splitter to split a beam of light into two fine beams, which then image the ocular fundus onto the CCD. When the focus is at its sharpest position, the split beams align horizontally. At this point, the LED white light illumination system, installed in the imaging module on the three-dimensional movable platform, emits uniform white light of appropriate intensity to illuminate the ocular fundus. The imaging system captures the fundus information onto the CCD, and the received signals are displayed in real-time on a liquid crystal display (LCD) through the control system. Doctors can visually assess the patient's ocular fundus on the LCD screen.

    AI/ML Overview

    The provided FDA 510(k) clearance letter for the Optain Health Resolve Fundus Camera focuses primarily on establishing substantial equivalence to a predicate device (Next Sight Srl Nexy). For this type of device (an ophthalmic camera), the clearance process in this document does not necessitate a detailed clinical study for performance evaluation that would typically involve acceptance criteria for diagnostic accuracy (e.g., sensitivity, specificity) of an AI algorithm. Instead, the performance data presented is focused on demonstrating that the device meets safety and basic functional standards, similar to the predicate device.

    Therefore, many of the requested points regarding AI algorithm performance (like specific acceptance criteria for diagnostic accuracy, sample sizes for test sets, expert adjudication methods, MRMC studies, standalone performance, and ground truth establishment for training/test sets) are not explicitly described or required for this particular regulatory submission type, given the device's classification and stated indications for use. The device's indication is for "taking digital images" and "aid to clinicians in the evaluation and diagnosis of ocular health," implying that the device primarily performs an imaging function, and any "diagnosis" is still ultimately made by the human clinician using the image.

    Below is an attempt to answer the questions based only on the provided text. Where information is not available, it will be stated as such.


    Device: Optain Health Resolve Fundus Camera

    Indications for Use: The Resolve Fundus Camera is an automatic eye-fundus camera intended for taking digital images of a human retina with or without the use of a mydriatic agent. It is intended for use as an aid to clinicians in the evaluation and diagnosis of ocular health.

    Acceptance Criteria and Reported Device Performance

    The document describes the device's performance in terms of compliance with recognized consensus standards rather than diagnostic performance metrics (e.g., sensitivity, specificity, accuracy) for an AI algorithm. The acceptance criteria are implicit in meeting the requirements of these standards.

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (Implied)Reported Device Performance
    Electrical Safety (IEC 60601-1)Complies with IEC 60601-1
    Electromagnetic Compatibility (IEC 60601-1-2)Complies with IEC 60601-1-2
    Device Usability (IEC 60601-1-6)Complies with IEC 60601-1-6
    Ocular Light Hazard Protection (ANSI Z80.36)Complies with ANSI Z80.36
    Biocompatibility (ISO 10993-1, -5, -10, -23)Complies with ISO 10993-1, -5, -10, -23 (for surface device, intact skin, limited duration)
    Fundus Camera Performance (ISO 10940)Complies with ISO 10940
    General Ophthalmic Instrument Requirements (ISO 15004-1)Complies with ISO 15004-1
    DICOM Compliance (NEMA PS 3.1-3.20)Complies with NEMA PS 3.1-3.20 (DICOM Set)
    Battery Safety (IEC 62133-2)Complies with IEC 62133-2
    Software Verification & Validation"Software verification and validation activities were performed to ensure the device performed as intended and software documentation appropriate for the Basic documentation set." (No specific metrics provided in this summary)

    2. Sample size used for the test set and the data provenance:

    • The document states "Non-clinical testing was performed," and "Performance testing" but does not specify a "test set" in the context of a dataset for evaluating an AI algorithm's diagnostic performance.
    • The tests are primarily related to general device safety, function, and image quality standards compliance, not the diagnostic accuracy of an AI.
    • Data Provenance: Not specified, but likely laboratory or engineering test data, not patient data from a specific country or retrospective/prospective study.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable/Not specified in the provided document, as no specific diagnostic ground truth for an AI algorithm's performance is described. The device's function is to aid clinicians, not to output a diagnosis via AI.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • Not applicable/Not specified, for the same reasons as above.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No MRMC study is described in this 510(k) summary. The device's clearance is based on substantial equivalence to a predicate ophthalmic camera, not on a claim of AI-assisted diagnostic improvement.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • No standalone AI performance study is described. The device is an "automatic eye-fundus camera" which "aids clinicians." There is no mention of an AI algorithm producing a diagnostic output independently of a human.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • Not applicable/Not specified, as the performance evaluation is focused on device functionality and safety standards, not diagnostic accuracy against a clinical ground truth.

    8. The sample size for the training set:

    • Not applicable/Not specified. The document does not describe a training set for an AI algorithm. If there are "auto-alignment and auto-focus algorithms," these might involve machine learning, but the document does not detail their training data or performance evaluation beyond general "software verification and validation."

    9. How the ground truth for the training set was established:

    • Not applicable/Not specified, for the same reasons as above.
    Ask a Question

    Ask a specific question about this device

    K Number
    K243878

    Validate with FDA (Live)

    Device Name
    CLARUS (700)
    Date Cleared
    2025-04-17

    (120 days)

    Product Code
    Regulation Number
    886.1120
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Dublin, California 94568

    Re: K243878
    Trade/Device Name: Clarus (700)
    Regulation Number: 21 CFR 886.1120
    Device Trade Name: CLARUS 700 v 1.2
    510(k) number: K243878
    Classification: 21 CFR 886.1120
    DEVICE

    Predicate Device: CLARUS 700 v 1.1
    510(k) Number: K191194
    Classification: 21 CFR 886.1120
    camera | Identical |
    | Classification Product Code | QER | QER | Identical |
    | Regulation Number | 886.1120
    | 886.1120 | Identical |
    | Class | Class II | Class II | Identical |
    | Review Panel | Ophthalmic | Ophthalmic

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CLARUS 700 ophthalmic camera is indicated to capture, display, annotate and store images to aid in the diagnosis and monitoring of diseases and disorders occurring in the retina, ocular surface and visible adnexa. It provides true color and autofluorescence imaging modes for stereo, widefield, ultra-widefield, and montage fields of view.

    The CLARUS 700 angiography is indicated as an aid in the visualization of vascular structures of the retina and the choroid.

    Device Description

    The CLARUS 700 is an active, software controlled, high resolution ophthalmic imaging device for In-vivo imaging of the human eye. Imaging modes include True color, Fundus Auto-fluorescence with green excitation, Fundus Auto-fluorescence with blue excitation, Fluorescein Angiography, Stereo External eye and Fluorescein Angiography- Indocyanine green angiography (FA-ICGA). All true color images can be separated into red, green and blue channel images to help enhance visual contrast of details in certain layers of the retina.

    The CLARUS 700 angiography imaging aids in the visualization of the vascular structures of the retina and the choroid. With a single capture, CLARUS 700 produces a 90º high definition widefield image. Widefield images are automatically merged to achieve a 135º ultra-widefield of view. The CLARUS 700 makes use of a deep learning algorithm for Optic Nerve Head (ONH) detection. The ultra-widefield montage on CLARUS 700 is no longer dependent just on the patient accurately fixating their gaze on the internal fixation. With the ONH detection, the software will find the optic nerve and determine based on the image(s) captured where the patient was gazing at the point of capture. The CLARUS 700 device allows clinicians to easily review and compare high-quality images captured during a single exam while providing annotation and caliper measurement tools that allow in-depth analysis of eye health. CLARUS 700 is designed to optimize each patient's experience by providing a simple head and chin rest that allows the patient to maintain a stable, neutral position while the operator brings the optics to the patient, facilitating a more comfortable imaging experience. The ability to swivel the device between the right and left eye helps technicians capture an image without realigning the patient. Live IR Preview allows the technician to confirm image quality and screen for lid and lash obstructions, prior to imaging, ensuring fewer image recaptures.

    The CLARUS 700 device's principle of operation is Slit Scanning Ophthalmic Camera also referred to as Broad Line Fundus Imaging (BLFI). During image capture, a line of illumination passes through the slit and scans across the retina. A 2D monochromatic camera captures the returned light to image the retina. A single sweep of the illumination is used to illuminate the retina for image capture. Repeated sweeps of near infrared light are used for a live retina view for alignment. Red, green and blue LEDs sequentially illuminate to generate true color images. Blue and green LED illumination enables Fundus Autofluorescence (FAF) imaging. Fluorescein Angiography images are captured with green LED illumination at a wavelength that stimulates fluorescence of the injected sodium fluorescein dye. The principle of operation of CLARUS 700 has not changed since the previous clearance, K191194.

    The CLARUS 700 system is mainly comprised of an acquisition device, all-in-one PC, keyboard, mouse, instrument lift table and external power supply.

    The device hardware is based on the predicate CLARUS 700 (K191194) hardware. The new ICGA imaging mode on the device required the following hardware changes as stated in the summary above:

    • Lightbox for Infrared (IR) Laser
    • Modified Slit filter – FA/ICG Slit Excitation Filter – new coating, no change to FA
    • Modified Turret Filter 1- FA/ICG Dual Band barrier filter – new coating, no change to FA.
    • Added Turret Filter 2 – Added second filter. Same coating as Turret Filter 1 to eliminate cornea reflex band in ICG images with a different shape.
    • Added Large Alignment Tool (LAT)
    • Added ICG Power Meter Tool

    The CLARUS software provides the user the capability to align, capture, review and annotate images. The software has two installation configurations: Software installed on the Instrument (Acquisition & Review) as well as Software installed on a separate 'Review Station' (Laptop or Computer) (only Review).

    The DEVICE software version 1.2 is based on the predicate CLARUS 700 software version 1.0 (K191194).

    Added capability for DEVICE software version 1.2 include:

    • Simultaneous capture of Fluorescein Angiography (FA) + Indocyanine Green Angiography (ICGA)
    • Angiography Movie: Capture of multiple pictures in sequence, after a single press of a button. Available for FA, ICGA and Simultaneous FA+ICGA.
    • Early Treatment Diabetic Retinopathy Study (ETDRS) – Manual placement of ETDRS grids (7 field ETDRS and Macula ETDRS) over the pictures:
      • The ETDRS 7-fields grid in CLARUS is a display of the standard 7-fields in Color Fundus Photography used to determine an ETDRS (Early Treatment Diabetic Retinopathy Study) level for patients with Diabetic Retinopathy. These 7-fields in and around the macular region are displayed in one single widefield image according to definitions followed by the gold-standard 7-field images using narrow-field fundus cameras.
      • The Macular ETDRS grids display assists in the identification of an ETDRS level in nine subfields centered around the fovea.
    • ICGA Boost Mode: user-selectable option for ICGA capture that increase used light to obtain better picture at later phase.
    • 8 up view: addition of the possibility to view eight pictures side by side (currently it is only possible to see 1, 2, 4, 16)

    The CLARUS 700 device meets the requirements of ISO 10940:2009 standard. The device technical specifications are identical to the predicate device.

    AI/ML Overview

    The provided text is a 510(k) clearance letter and summary for the CLARUS 700 ophthalmic camera, particularly focusing on the new v1.2 software update. While it discusses the device's intended use, technical characteristics, and various tests performed, it does not contain detailed acceptance criteria or the specific results of a comprehensive clinical study in the format of "acceptance criteria vs. reported device performance."

    The document mentions "clinical testing aimed at demonstrating the ability of the new model of CLARUS 700 to image a variety of retinal and choroidal conditions using simultaneous FA and simultaneous ICGA and standalone ICGA." It states that "Our analysis of the grading of angiography images showed that the quality of the images captured by the CLARUS 700 simultaneous FA, simultaneous ICGA, and standalone ICGA were clinically acceptable by three independent graders." However, this is a qualitative statement rather than quantitative acceptance criteria with specific performance metrics.

    Therefore, I cannot populate a table of acceptance criteria and reported device performance from the provided text. I can, however, extract related information from the "Clinical Data" section:


    Acceptance Criteria and Study Details (Based on provided text)

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (Quantitative/Specific)Reported Device Performance (Quantitative/Specific)
    Not explicitly defined in the provided document.Not explicitly defined in the provided document beyond a qualitative statement.
    Example of typical criteria (not from text): Minimum percentage of images graded as "clinically acceptable"Reported: "Our analysis of the grading of angiography images showed that the quality of the images captured by the CLARUS 700 simultaneous FA, simultaneous ICGA, and standalone ICGA were clinically acceptable by three independent graders."

    Explanation: The document states that the "quality of the images... were clinically acceptable by three independent graders." This implies an implicit acceptance criterion that images must be "clinically acceptable." However, no quantitative threshold (e.g., "90% of images must be clinically acceptable") is provided, nor are specific quantitative performance metrics (e.g., actual percentage of acceptable images).

    2. Sample Size Used for the Test Set and Data Provenance:

    • Test Set Sample Size: Not specified in the provided text.
    • Data Provenance: Not specified (e.g., country of origin, retrospective/prospective). The text only states "ZEISS conducted clinical testing."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of those Experts:

    • Number of Experts: Three independent graders.
    • Qualifications of Experts: Not specified (e.g., "radiologist with 10 years of experience").

    4. Adjudication Method for the Test Set:

    • Adjudication Method: Not specified beyond "three independent graders." It does not mention if consensus, majority rule (e.g., 2+1), or another method was used for discordant readings.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done and the Effect Size of how much human readers improve with AI vs without AI assistance:

    • MRMC Study: No, an MRMC comparative effectiveness study was not described. The study focused on the image quality produced by the device as assessed by human graders, not on the improvement of human readers' performance with AI assistance.
    • Effect Size: Not applicable, as no MRMC study comparing human readers with/without AI assistance was conducted or reported. The device's deep learning algorithm for ONH detection is noted, but its specific impact on reader performance or an MRMC study related to it is not detailed.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • Standalone Performance: Not explicitly detailed or quantified. The document notes that "The CLARUS 700 makes use of a deep learning algorithm for Optic Nerve Head (ONH) detection." However, no standalone performance metrics (e.g., specificity, sensitivity, accuracy) for this algorithm are provided in the clinical data summary.

    7. The Type of Ground Truth Used:

    • Type of Ground Truth: Expert grading/consensus from "three independent graders" on "clinical acceptability" of angiography images. It is not stated if this was against a pathology or outcomes data gold standard.

    8. The Sample Size for the Training Set:

    • Training Set Sample Size: Not specified in the provided text. The document refers to a "deep learning algorithm for Optic Nerve Head (ONH) detection." While this implies a training set was used, its size is not disclosed.

    9. How the Ground Truth for the Training Set Was Established:

    • Ground Truth for Training Set: Not specified.
    Ask a Question

    Ask a specific question about this device

    K Number
    K243664

    Validate with FDA (Live)

    Device Name
    Sentinel Camera
    Manufacturer
    Date Cleared
    2024-12-17

    (20 days)

    Product Code
    Regulation Number
    886.1120
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Saint Paul, Minnesota 55114

    Re: K243664

    Trade/Device Name: Sentinel Camera Regulation Number: 21 CFR 886.1120
    |
    | Classification Name: | Camera, Ophthalmic, AC-Powered(21 CFR 886.1120
    |
    | CFR Section | 21 CFR 886.1120
    | 21 CFR 886.1120

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Sentinel Camera is a non-mydriatic medical digital camera that is intended to capture digital images of the human eye.

    Device Description

    The Sentinel Camera is accompanied by the following accessories: a charging base, eye cup, and power cable. The Sentinel Camera is designed for use in a medical environment. Captured images are used for documentation and consultation. Sentinel Camera has internal memory where captured images are stored. The Sentinel Camera is designed for non-mydriatic retinal imaging. In non-mydriatic imaging no mydriasis is needed because infrared light is used for targeting the retina and white light is flashed when an image is taken. The pupil does not respond to the infrared light, so examination is convenient for the patient. With small pupils, it is recommended to use mydriatic drops. The Sentinel Camera has three internal fixation targets for the patient to fixate on during imaging. The middle fixation target provides a macula-centered image. The left and right fixation targets provide disc-centered images. The transfer of images to the AI Optics Server is carried out via Wi-Fi communication. The Sentinel Camera has a rechargeable Li-ion battery that is charged when the camera is placed on charging base, which is connected to the mains by the power cable.

    AI/ML Overview

    The provided text describes a 510(k) summary for the "Sentinel Camera," an ophthalmic camera. However, it does not contain information about acceptance criteria or a study that proves the device meets those criteria, particularly in the context of an AI-powered diagnostic or assistive tool. The document focuses on comparing the Sentinel Camera to a predicate device (Optomed Aurora Camera) based on their technical characteristics and safety/performance standards.

    The 510(k) summary explicitly states: "Performance data for the Sentinel Camera, including extensive testing against recognized standards, supports the substantial equivalence of the Sentinel Camera to the predicate device. Both devices underwent similar testing to external standards." It concludes that the device "meets the necessary safety and performance criteria, with no new questions of safety or effectiveness."

    Crucially, there is no mention of any AI component within the Sentinel Camera's functionality in this document, nor any studies that would involve AI performance metrics (like sensitivity, specificity, or human-AI collaboration studies). The device is described as "a non-mydriatic medical digital camera that is intended to capture digital images of the human eye."

    Therefore, based on the provided text, I cannot answer the questions regarding acceptance criteria and studies proving the device meets them in the context of AI performance. The document does not provide such information.

    If this device were to incorporate AI functionality, the information requested (acceptance criteria, study design, sample sizes, ground truth establishment, expert qualifications, etc.) would be crucial for its regulatory submission. However, this particular document does not detail any such AI-related performance studies.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242508

    Validate with FDA (Live)

    Date Cleared
    2024-12-09

    (109 days)

    Product Code
    Regulation Number
    886.1120
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Minnesota 55114

    Re: K242508

    Trade/Device Name: Verily Numetric Retinal Camera Regulation Number: 21 CFR 886.1120
    |
    | Classification | Class II Medical DeviceRegulation Number: 21 CPR 886.1120
    Predicate Device | K182199,NFC-700 Non-Mydriatic Auto Fundus CameraRegulation Number: 21 CPR 886.1120
    predicate device, the subject device is classified as "Ophthalmic Camera" in accordance with 21 CPR 886.1120

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Verily Numetric Retinal Camera is a non-contact, high resolution digital imaging device which is suitable for photographing, displaying and storing images of the retina segment of the eye to be evaluated under non-mydriatic conditions.

    Verily Numetric Retinal Camera is indicated for in-vivo viewing of the posterior segment of the eye. The images are intended for use as an aid to clinicians in the evaluation, diagnosis, and documentation of ocular health.

    Device Description

    The Verily Numetric Retinal Camera (VNRC), the subject device, is a tabletop fundus camera that provides non-mydriatic, color, posterior segment images of the eye as an aid to clinicians in the evaluation and diagnosis of eye disease. It is a non-contact, high-resolution digital imaging device that is suitable for photographing, displaying, and storing images of the retina to be evaluated under non-mydriatic conditions.

    The Verily Numetric Retinal Camera takes images of the fundus in the following manner:

    Focusing: The patient interactively focuses an image shown on a microdisplay to the best qualitative focus by turning a knob on an external peripheral device which modulates the camera optics.

    Alignment: The patient is shown a fixation target on the microdisplay and through an interactive session with position feedback, the patient aligns their pupil to the camera. The pupil location is determined using eye-tracking.

    Image Capture: White light from LEDs illuminates the fundus. The light reflection from the fundus is captured by a color CMOS sensor.

    AI/ML Overview

    The Verily Numetric Retinal Camera has the following acceptance criteria and reported device performance:

    1. Table of Acceptance Criteria and Reported Device Performance

    Performance ItemAcceptance CriteriaReported Device Performance
    Resolving power (center)≥ 60 line pairs/mm at the center of the fieldPass
    Resolving power (mid field)≥ 40 line pairs/mm at the mid field (r/2)Pass
    Resolving power (periphery)≥ 25 line pairs/mm at the periphery of the field (r)Pass
    Field of view45 degreesPass
    Pixel pitch tolerance< 7%Pass
    Alignment illuminationThe alignment illumination is done via Near Infrared (NIR) LEDs during eye tracking. The intensity of the NIR LEDs is controlled by SW.Pass
    Flash illuminationThe flash illumination is done via white LEDs during the image capture. The intensities and durations of the white LEDs are controlled by SW.Pass
    Range of focus-20D to +20D (no compensating lens)Pass
    Minimum pupil size3.0mmPass
    AlignmentInteractive alignment using 3D tracking.Pass
    Image qualityThe gradability of images captured by VNRC is comparable to the predicated device on the same population.Pass

    2. Sample Size and Data Provenance for Test Set

    The document mentions that non-clinical performance testing for the Verily Numetric Retinal Camera includes analysis using raw data collected via a retrospective clinical study. It also states that the "gradability of images captured by VNRC is comparable to the predicated device on the same population."

    However, the specific sample size used for the test set is not explicitly stated in the provided text. The country of origin of the data is also not specified.

    3. Number and Qualifications of Experts for Ground Truth (Test Set)

    The document does not provide information on the number of experts used to establish ground truth for the test set or their specific qualifications (e.g., "radiologist with 10 years of experience"). It only mentions that the images are "intended for use as an aid to clinicians in the evaluation, diagnosis, and documentation of ocular health" and that "the gradability of images captured by VNRC is comparable to the predicated device on the same population." This implies clinical evaluation but lacks details on the expert panel.

    4. Adjudication Method for the Test Set

    The document does not specify an adjudication method (e.g., 2+1, 3+1, none) for the test set.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    A multi-reader multi-case (MRMC) comparative effectiveness study was not explicitly described in the provided text in the typical sense of measuring human reader improvement with AI assistance. The document compares the performance of the device itself (Verily Numetric Retinal Camera) to a predicate device (NFC-700) regarding image quality and technical specifications. It notes that "the gradability of images captured by VNRC is comparable to the predicated device on the same population," implying a comparison of image utility for human readers, but no effect size on human reader improvement with AI assistance is provided as the device is a camera, not an AI diagnostic tool.

    6. Standalone (Algorithm Only) Performance Study

    The Verily Numetric Retinal Camera is a hardware device (ophthalmic camera) that captures images, not a standalone AI algorithm. Therefore, a standalone (algorithm only) performance study as typically understood for AI-based diagnostic software was not conducted or described. The focus is on the camera's ability to produce high-quality, gradable images.

    7. Type of Ground Truth Used (for Test Set)

    The document primarily refers to evaluating "image quality" and "gradability." While not explicitly stated as "expert consensus ground truth," the comparison of "gradability of images captured by VNRC... comparable to the predicated device on the same population" strongly implies that human expert evaluation of image quality was used as a form of ground truth for assessing the usability of the images for clinical purposes. There is no mention of pathology or outcomes data being used as ground truth for effectiveness.

    8. Sample Size for the Training Set

    The document does not provide a sample size for a training set. This is expected as the device is a camera, not an AI algorithm that typically requires a training set.

    9. How Ground Truth for Training Set Was Established

    As the device is a camera and not an AI algorithm, the concept of a "training set" and establishing "ground truth for the training set" does not directly apply in the context of this submission. The camera's performance is evaluated against technical specifications and a comparison to a predicate device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K233561

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-04-10

    (156 days)

    Product Code
    Regulation Number
    886.1570
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    . §886.1120, Ophthalmic camera |
    | Product Code: | OBO, HKI

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TOPCON 3D Optical Coherence Tomography 3D OCT-1 (Type:Maestro2) is a noncontact, high resolution tomographic and biomicroscopic imaging device that incorporates a digital camera for photographing, displaying and storing the data of the retina and surrounding parts of the eye to be examined under Mydriatic and non-Mydriatic conditions.

    The TOPCON 3D Optical Coherence Tomography 3D OCT-1 (Type:Maestro2) is indicated for in vivo viewing, axial cross sectional, and three-dimensional imaging and measurement of posterior ocular structures, including retina, retinal nerve fiber layer, macula and optic disc as well as imaging of anterior ocular structures.

    It also includes a Reference Database for posterior ocular measurements which provide for the quantitative comparison of retinal nerve fiber layer, optic nerve head, and the macula in the human retina to a database of known normal subjects.

    The TOPCON 3D Optical Coherence Tomography 3D OCT-1 (Type:Maestro2)is indicated for use as a diagnostic device to aid in the diagnosis, documentation and management of ocular health and diseases in the adult population.

    Device Description

    3D OPTICAL COHERENCE TOMOGRAPHY 3D OCT-1(type: Maestro2) with System linkage software (herein referred to as "Maestro2") is a non-contact ophthalmic device combining spectral-domain optical coherence tomography (SD-OCT) with digital color fundus photography. Maestro2 includes an optical system of OCT, fundus camera (color. IR and Red-free image), and anterior observation camera. The color fundus camera acquires color images of the posterior segment of the eye under mydriatic or non-mydriatic conditions. Maestro2 is used together with IMAGEnet6 by connecting via System linkage software which is a PC software installed to off the shelf PC connected to Maestro2. The remote operation function is not intended to be used from any further distance (e.g., operation from different rooms or different buildings) other than social distancing recommendations.

    AI/ML Overview

    This document is a 510(k) summary for the Topcon 3D Optical Coherence Tomography 3D OCT-1 (type: Maestro2) with System linkage software. It focuses on demonstrating substantial equivalence to a previously cleared predicate device, rather than presenting a performance study with detailed acceptance criteria for an AI/algorithm-driven diagnostic device.

    Therefore, the document does not contain the information requested regarding acceptance criteria and a study proving the device meets them, especially in the context of AI/algorithm performance. It primarily addresses the device's technical specifications, intended use, and conformance to general medical device standards.

    Specifically, it states:

    • "This section is not applicable because clinical data was not required for this 510(k) submission." (Page 6)
    • The substantial equivalence discussion highlights that the main difference in the subject device is the "system linkage software" and an "optional remote operation function." For the remote operation function, it states that "comparison testing confirmed that image quality and diagnosability is the same with or without the remote operation function." This is a functional comparison, not a clinical performance study with defined acceptance criteria for diagnostic output.

    In summary, the provided text does not offer the details required to answer your prompt.

    Ask a Question

    Ask a specific question about this device

    K Number
    K231230

    Validate with FDA (Live)

    Date Cleared
    2023-12-05

    (221 days)

    Product Code
    Regulation Number
    886.1120
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    , QC H4P 2P5 Canada

    Re: K231230

    Trade/Device Name: Optina-4C (MHRC-C1N) Regulation Number: 21 CFR 886.1120
    | Camera, Ophthalmic, Ac-Powered (21 CFR | | |
    | | 886.1120

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Optina-4C™ is intended to capture images of the retina at multiple wavelengths (colors) under mydriatic conditions.

    Device Description

    Optina-4C™ (model: MHRC-C1N) is a mydriatic fundus camera (also called retinal camera) that presents eye care practitioners (optometrists and ophthalmologists) with a series of the retina obtained sequentially at specific wavelengths (colors) in the spectral range 905 nm to 450 nm in steps of 5 nm.

    Pictures of the retina are obtained on a field-of-view of 31.5° without contact with the eye. The patient is positioned in front of the device with the chin on the chinrest and forehead on the forehead rest and a positioning system is used to align the camera relative to the patient's eye. An external fixation target is available to guide the patient's eye. A focus wheel allows for the accommodation for eye refractive error in the range of -15 to +15 diopters. The images are displayed on a monitor and can be saved on the computer for future consultation.

    The illumination light of Optina-4C™ is provided by a Tunable Laser Source (TLS). The TLS selects a narrow band of light from a broadband white illumination source. Only a single monochromatic band can output the TLS at a time. The alignment of the retinal camera relative to the patient's eye phase is performed with the illumination light set at a wavelength of 700 nm. The image acquisition phase consists of the sequential acquisition of a series of 92 monochromatic images at wavelengths from 905 nm in steps of 5 nm. Each frame is captured with an exposure time of 10 ms, resulting in a total acquisition time of 920 ms.

    The 92 images can be visualized one by one in Optina-4C™ acquisition software. The retinal images captured by Optina-4C™ are monochromatic images having a spectral bandwidth of "10 nm centered on the wavelength indicated in the upper left corner of the visualization pane, with a spectral accuracy of 7.5 nm.

    AI/ML Overview

    The provided text is a 510(k) summary for the Optina-4C (MHRC-C1N) device, which is a mydriatic fundus camera. The document primarily focuses on demonstrating substantial equivalence to a predicate device (MHRC-C1) and outlines various performance tests conducted to support this claim.

    However, the document does not contain specific acceptance criteria for the device's performance regarding its intended use of capturing retinal images, nor does it present a detailed study that proves the device meets such criteria in terms of clinical accuracy or utility.

    Instead, the document focuses on:

    • Technological equivalence: Stating that the main elements of the hardware, illumination, and monochromatic images are the same as the predicate.
    • Verification of safety and regulatory compliance: Covering software evaluation, electrical safety, electromagnetic compatibility, biocompatibility, and compliance with recognized consensus standards for ophthalmic cameras (ISO 15004-1:2020, ISO 10940:2009, ANSI Z80.36:2021).
    • Spectral accuracy and reliability of retinal images: This was evaluated in an "eye model using a reference material with tabulated spectral bands," but no specific acceptance criteria or performance metrics (e.g., sensitivity, specificity, accuracy for a particular clinical task) are provided from this evaluation.

    Therefore, I cannot populate the requested table and information as the necessary details regarding acceptance criteria, reported device performance related to a specific clinical task, test set characteristics, expert involvement, adjudication, or a multi-reader multi-case study are not present in the provided text. The document describes tests to ensure the device functions safely and in a manner similar to its predicate, but not how well it performs a particular diagnostic task against established clinical benchmarks or ground truth.

    Missing Information:

    • No specific acceptance criteria for diagnostic performance (e.g., image quality metrics, sensitivity/specificity for detecting a condition).
    • No reported clinical performance metrics directly related to the device's ability to 'capture images' that translates to a clinical outcome.
    • No details on a clinical study where the device's images were evaluated for a specific purpose against a ground truth.

    The document seems to describe the device as an image capture device, and the "performance testing" focuses on its technical specifications and safety rather than its diagnostic accuracy for a particular condition.