510(k) Data Aggregation

    K Number
    K251246

    Validate with FDA (Live)

    Device Name
    Sparrow Ascent
    Date Cleared
    2025-08-25

    (125 days)

    Product Code
    Regulation Number
    882.5896
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Pennsylvania 15146

    Re: K251246
    Trade/Device Name: Sparrow Ascent
    Regulation Number: 21 CFR 882.5896
    Classification Name: Percutaneous nerve stimulator for substance use disorders

    Regulation Number: 21 CFR 882.5896
    K230796
    K233166

    Neither the predicate

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Sparrow Ascent is a transcutaneous nerve field stimulator that is intended to be used in patients experiencing opioid withdrawal in conjunction with standard symptomatic medications and other therapies for opioid withdrawal symptoms under the supervision of trained clinical personnel.

    Device Description

    The Sparrow Ascent is a transcutaneous auricular neurostimulation (tAN) system intended to provide non-invasive, transcutaneous stimulation of the nerves around the auricle (ear). The device is indicated as an aid in the reduction of opioid withdrawal symptoms in adult patients. The Sparrow Ascent is a battery operated, prescription device that delivers mild electrical stimulation to the nerves around the auricle (ear), which carry information to the central nervous system. The Sparrow Ascent is to be used in clinical environments (e.g., doctor's office, clinics, rehab centers, and hospitals) and/or at home. Users of the subject device include adults experiencing opioid withdrawal symptoms. Stimulation parameters (i.e., the strength of stimulation) are set by the user's clinician, and users can only adjust stimulation intensity (amplitude) at home. The system consists of three main components 1) a disposable Earpiece, 2) a Cable, and 3) the External Pulse Generator (EPG).

    AI/ML Overview

    The provided FDA 510(k) clearance letter pertains to the Sparrow Ascent Transcutaneous Nerve Stimulator. The key aspect of this submission is a modification to the device's earpiece, specifically changing the stimulation site for the auricular branch of the vagus nerve (ABVN) from the cymba concha to the mastoid. The manufacturer aims to demonstrate that this change does not raise new questions of safety or effectiveness and that the modified device remains substantially equivalent to its predicate.

    Here's an analysis of the acceptance criteria and the study that proves the device meets them:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria for this 510(k) submission are primarily based on demonstrating functional equivalence of the new mastoid stimulation site to the previously cleared cymba concha site, specifically in terms of brain activation patterns, and overall safety and efficacy as compared to the predicate and reference devices.

    Acceptance CriteriaReported Device Performance (from the document)
    Brain Activation Equivalence: Spatial distribution of brain activity following mastoid stimulation is equivalent to cymba concha stimulation of the ABVN.fMRI study showed activation maps for mastoid and cymba concha stimulation were significantly correlated (r = 0.61, p < 0.001). This indicates consistent central responses between the two stimulation sites and reliable stimulation-induced brain activation at the mastoid.
    Similar Current Density: The output related to nerve activation for the subject device is similar to the reference device."[T]he current density (i.e., the output related to nerve activation) is similar between the subject and the reference devices and helps demonstrate equivalent effectiveness." (No specific numerical range provided in the summary, but stated as similar.)
    Similar Power and Charge Density: The output related to stimulation site impact for the subject device is similar to the predicate and reference devices."[P]ower and charge density (i.e., the output related to the impact on the stimulation site) is similar between the subject, the predicate, and the reference devices, and helps demonstrate equivalent safety." (No specific numerical range provided in the summary, but stated as similar.)
    Non-clinical Performance: Device operates as expected, meets product requirements, delivers safe and effective stimulation."Non-clinical performance testing verified that, like the predicate, the subject device operates as expected when used as intended, and both meets and satisfies product requirements." "concluded that the subject device can safely and effectively deliver transcutaneous peripheral nerve stimulation when used as intended."
    Biocompatibility: Materials used remain biocompatible."In addition to testing performed to support the clearance of K230796 (e.g., biocompatibility), which remains applicable to the subject device..." (Implies original biocompatibility data sufficient and still valid).
    Service Life: Demonstrated 3-year service life."extended service life testing was completed for the subject device to verify a service life of 3 years."

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set (Clinical Study): 24 healthy adults.
    • Data Provenance: The document does not explicitly state the country of origin. It describes a prospective clinical study (fMRI study) conducted to compare brain activation patterns.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Experts

    • The document does not mention the use of external experts to establish ground truth for the fMRI study. The "ground truth" in this context is the objective physiological response (brain activation patterns) measured by the fMRI, which is interpreted by the study's researchers based on established neuroimaging analysis techniques (e.g., GLM).
    • The qualifications of the researchers/analysts interpreting the fMRI data are not specified in the provided text.

    4. Adjudication Method for the Test Set

    • No adjudication method is described for the fMRI study results. The analysis methods (e.g., General Linear Modeling, one-sample t-tests, correlation analysis) are standard scientific approaches for interpreting fMRI data, not an adjudication process by multiple human observers.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No MRMC comparative effectiveness study was mentioned or performed. This submission is not evaluating human reader performance with or without AI assistance. Instead, it focuses on the equivalence of a technological characteristic (stimulation site) for a device that delivers nerve stimulation for opioid withdrawal, supported by objective physiological data (fMRI).

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Performance

    • This is not an AI/Software as a Medical Device (SaMD) submission in the typical sense that would require standalone algorithm performance evaluation. The device is a hardware stimulator. The fMRI study evaluates the physiological effect of the stimulation, which is a standalone effect of the device itself, not an algorithm's diagnostic performance.

    7. Type of Ground Truth Used

    • The primary "ground truth" for the clinical study was objective physiological data (brain activation patterns as measured by fMRI). This data was then analyzed statistically to demonstrate equivalence.

    8. Sample Size for the Training Set

    • Not applicable / Not explicitly mentioned. This submission describes a modification to a hardware device and an fMRI study to demonstrate functional equivalence. There is no mention of an AI algorithm or a training set for such an algorithm. The 24 healthy adults were part of a test (or validation) set for the fMRI study, not a training set for an AI model.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable. As no AI algorithm training set is mentioned, the method for establishing its ground truth is not provided.
    Ask a Question

    Ask a specific question about this device

    K Number
    K233166

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-05-29

    (245 days)

    Product Code
    Regulation Number
    882.5896
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Columbia 20004

    Re: K233166

    Trade/Device Name: NET Recovery Corp/NET Device Regulation Number: 21 CFR 882.5896
    Percutaneous nerve stimulator for substance use disorders |
    | Regulation Number: | 21 CFR 882.5896
    This submission demonstrates compliance with the Special Controls per 21 CFR 882.5896.

    Summary of

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NET Device is a transcutaneous alternating current stimulator (ACS) that is intended to be used in patients experiencing opioid withdrawal in conjunction with standard symptomatic medications and other therapies for opioid withdrawal symptoms under the supervision of trained clinical personnel.

    Device Description

    The NET Device is a non-invasive, battery-powered, portable, prescription device designed to provide bilateral, transcranial, transcutaneous, alternating current stimulation (tACS) to be used in patients experiencing opioid withdrawal under the supervision of trained clinical personnel. The system is comprised of one component (the NET Device), accessories (patient leads, electrodes, USB cable), and software (the clinician application). NET Devices, patient leads, and USB cables are reusable. No reprocessing, sterilization, maintenance, or recalibration is required. Electrodes are for single patient use only. The NET Device is used in professional healthcare facility environments (e.g., rehab centers and hospitals). If benefit is not established within 60 minutes of use, discontinue use and seek other methods of treatment.

    AI/ML Overview

    The provided document is a 510(k) summary for the NET Device, which is a transcutaneous alternating current stimulator intended for patients experiencing opioid withdrawal. The study described focuses on demonstrating the substantial equivalence of the NET Device to its predicate device, the Sparrow Therapy System.

    Here's an analysis of the acceptance criteria and the study that proves the device meets them:

    1. A table of acceptance criteria and the reported device performance

    The document doesn't explicitly state "acceptance criteria" for performance in a tabular format. Instead, it defines a clinically meaningful decline in COWS (Clinical Opiate Withdrawal Scale) score as ≥15% reduction from baseline to 1-hour after the start of active NET stimulation, and then reports the device's performance against this benchmark. Safety is assessed by the absence of device-related adverse events and comparison of risk profiles to the predicate device.

    Acceptance Criterion (Implicit)Reported Device Performance (NET Device)
    Effectiveness: Achieve a statistically significant clinically meaningful decline in COWS total score from baseline to 1-hour.Achieved: The mean COWS total score in the active NET group decreased from a baseline of 18.1 (4.4) to 7.0 (4.1) at 1-hour, representing a mean decrease of 11.1 (5.2). This was statistically significant and exceeded the pre-specified 15% criterion, with 98.1% of the active group achieving a COWS score reduction of 15% or greater. The mean reduction was significantly greater in the active NET group (-11.13) than the sham group (-8.75), with a between-group difference of 15%. This equates to a 61% reduction in the active group compared to 46% in the sham group, indicating a 15% improvement with the device.
    Safety: No increase in adverse events compared to predicate device.Achieved: "There were no device-related adverse events (ADEs, or UADEs)." The risk profiles for the subject and predicate devices are comparable, both using transcutaneous nerve stimulation delivered through non-invasive earpieces without skin puncture. Clinical testing in 108 subjects demonstrated treatment tolerability and that identified risks (e.g., skin burns, irritation) have not increased.
    Technological Equivalence: Substantially similar technological characteristics and principles of operation to predicate.Achieved: The NET Device has the same general intended use and similar indications, technological characteristics, and principles of operation (auricular transcutaneous electrical stimulation) as the predicate (Sparrow Therapy System). Notable differences (bilateral vs. unilateral stimulation, higher instantaneous electrical output, higher frequency range) were evaluated and determined not to raise new questions of safety or effectiveness as demonstrated by non-clinical and clinical testing.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: 108 participants.
      • Active group: 53 participants
      • Sham group: 55 participants
    • Data Provenance:
      • Study Type: Prospective, randomized, parallel-group, sham-controlled, superiority study.
      • Country of Origin: One US site.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    The "ground truth" in this study is the Clinical Opiate Withdrawal Scale (COWS) score. The document states that COWS scores were measured, but it does not specify the number of experts or their qualifications for assessing these scores. It's implied that trained clinical personnel (nurses, physicians) administered the COWS assessments as standard practice for such a study, but no specific details are provided.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    The document does not describe any specific adjudication method for the COWS scores in the test set. It is standard for COWS assessments to be performed by a single trained clinician at each time point, so a multi-reader adjudication method would be unusual for this type of scale.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    An MRMC comparative effectiveness study was not done. This study is not evaluating an AI algorithm assisting human readers, but rather a direct therapeutic device (transcutaneous alternating current stimulator) and its effect on opioid withdrawal symptoms, compared to a sham control. Therefore, there is no discussion of human readers or AI assistance.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This question is not applicable. The NET Device is a therapeutic medical device, not an AI algorithm. Its performance is directly observed in patients, not as an algorithm-only output.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The primary "ground truth" used for effectiveness was the Clinical Opiate Withdrawal Scale (COWS) score, which is a standardized, clinician-rated assessment of opioid withdrawal severity. This is a form of expert assessment by trained clinical personnel.
    Secondary outcomes included:

    • Cumulative inpatient MOUD (Medications for Opioid Use Disorder) utilization.
    • Illicit opioid use during the outpatient phase (measured by oral fluid drug screen or timeline follow-back interview).
    • Presence of device-related adverse events for safety.

    8. The sample size for the training set

    This question is not applicable. The NET Device is a physical medical device, not a machine learning model, so there is no "training set" in the context of AI/ML. The clinical study described is a pivotal trial to demonstrate safety and effectiveness for regulatory clearance, not for training an algorithm.

    9. How the ground truth for the training set was established

    This question is not applicable, as there is no training set for an AI/ML algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K230796

    Validate with FDA (Live)

    Device Name
    Sparrow Ascent
    Date Cleared
    2023-06-20

    (90 days)

    Product Code
    Regulation Number
    882.5896
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    San Diego, California 92110

    Re: K230796

    Trade/Device Name: Sparrow Ascent Regulation Number: 21 CFR 882.5896
    use disorders |
    | Regulation Number: | 21 CFR 882.5896
    OF NON-CLINICAL TESTING

    The submission demonstrated compliance to the Special Controls per 21 CFR 882.5896

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Sparrow Ascent is a transcutaneous nerve field stimulator that is intended to be used in patients experiencing opioid withdrawal in conjunction with standard symptomatic medications and other therapies for opioid withdrawal symptoms under the supervision of trained clinical personnel.

    Device Description

    The Sparrow Ascent is a transcutaneous auricular neurostimulation (tAN) system intended to provide non-invasive, transcutaneous stimulation of the nerves on and/or around the auricle (ear). The device is indicated as an aid in the reduction of opioid withdrawal symptoms in adult patients. The Sparrow Ascent is a battery operated, prescription device that delivers mild electrical stimulation to the nerves on and/or around the auricle (ear), which carry information to the central nervous system. The Sparrow Ascent is to be used in clinical environments (e.g., doctor's office, clinics, rehab centers, and hospitals) and/or at home. Users of the subject device include adults experiencing opioid withdrawal symptoms. Stimulation parameters (i.e., the strength of stimulation) are set by the user's clinician, and users can only adjust stimulation intensity at home. The system consists of three main components 1) a disposable Earpiece, 2) a Cable, and 3) the External Pulse Generator (EPG).

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study details for the Sparrow Ascent device, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The FDA clearance letter does not explicitly state pre-defined acceptance criteria in terms of specific performance metrics (like sensitivity, specificity, or % reduction). Instead, the clinical study's primary efficacy endpoint served as the performance criterion for effectiveness.

    Acceptance Criteria (Primary Efficacy Endpoint)Reported Device Performance
    Successful mean percent change in COWS score (defined as a ≥15% reduction) from baseline, 60 minutes after the start of active tAN therapy.Successfully met. At the conclusion of Day 1 (120 minutes), 93.8% of participants had a clinically significant reduction in COWS score (≥15% reduction). This increased to 100% on Day 2 and was sustained across Day 5.
    Safety Endpoints: Prevalence of all adverse events (AEs), serious adverse events (SAEs), adverse device events (ADEs), serious adverse device effects (SADEs), unanticipated serious adverse device effects (USADEs), and device deficiencies.In 14 patients, who experienced a total of 943.6 hours of skin contact, there were no instances of adverse tissue reactions reported. The overall clinical study demonstrated acceptable safety profile, though specific AE rates are not detailed in this summary.
    Biocompatibility: Demonstrated compliance with ISO 10993 standards and supportive information from the RESTORE clinical study.Compliance with ISO 10993 series for cytotoxicity, skin sensitization, and irritation. RESTORE clinical study further supported biocompatibility with no adverse tissue reactions in 943.6 hours of skin contact among 14 patients.
    Software Verification: Compliance with IEC 62304 and ISO 14971.Explicitly states compliance with IEC 62304 and ISO 14971.
    Electromagnetic Compatibility and Electrical Safety: Compliance with ANSI/AAMI 60601-1, 60601-1-11, and 60601-1-2.Explicitly states compliance with ANSI/AAMI 60601-1, 60601-1-11, and 60601-1-2.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size (Clinical Study): 23 participants were enrolled, and 20 received tAN therapy.
    • Data Provenance: The study was conducted at two US sites, making the data provenance United States and prospective (as it was a designed clinical study for this purpose).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    The document does not mention the use of experts to establish a "ground truth" for the test set in the traditional sense of image interpretation or diagnosis. The ground truth for effectiveness was based on the Clinical Opiate Withdrawal Scale (COWS) scores, which are a standardized and objective measure of opioid withdrawal symptoms. These scores are typically assessed by trained clinical personnel. The document does not specify the number or qualifications of the personnel who administered the COWS scores in this study.

    4. Adjudication Method for the Test Set

    The document does not describe a traditional adjudication method for the test set data (e.g., 2+1, 3+1). The primary and secondary endpoints were based on changes in COWS scores, which are quantitative measures. The study was a double-blind, randomized, controlled study, which inherently helps to reduce bias in the assessment of outcomes.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. The device is a direct treatment device (nerve stimulator), not an AI-powered diagnostic tool for interpretation by human readers. Therefore, the concept of "how much human readers improve with AI vs without AI assistance" is not applicable here.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    The device itself is a "standalone" therapeutic device (a transcutaneous nerve stimulator) that delivers stimulation. It does not involve an algorithm providing outputs for human interpretation. Its performance is assessed directly on patient outcomes (reduction in COWS scores). The "algorithm" in this context refers to the device's operational parameters, not an AI diagnostic algorithm. The study described assesses the device's direct therapeutic effectiveness.

    7. The Type of Ground Truth Used

    The ground truth for the effectiveness study was clinical symptom scores (COWS scores), which are a standardized and objective measure of opioid withdrawal severity. Safety ground truth was based on reported adverse events (AEs).

    8. The Sample Size for the Training Set

    The document refers to the clinical study of the predicate device (K201873) and "leverag[ing] prior clinical testing" for effectiveness, but it primarily details the study performed for the current device (Sparrow Ascent). It's not clear if there was a separate "training set" in the context of machine learning, as this is a medical device, not an AI algorithm. The study described appears to be the primary clinical evidence for the device's effectiveness.

    9. How the Ground Truth for the Training Set Was Established

    As this is a medical device and not an AI algorithm, the concept of a "training set" and establishing "ground truth for the training set" in the machine learning sense is not directly applicable. The effectiveness was established through a prospective, double-blind, randomized, controlled multi-center clinical study evaluating the impact of the nerve stimulator on COWS scores, as described in section 7 above. The summary also references the prior clearance of the predicate device (NSS-2 Bridge, DEN170018) which would have undergone its own clinical studies to establish similar effectiveness.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221231

    Validate with FDA (Live)

    Device Name
    Drug Relief v1
    Manufacturer
    Date Cleared
    2022-06-06

    (38 days)

    Product Code
    Regulation Number
    882.5896
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Boulevard San Mateo, CA 94401

    Re: K221231

    Trade/Device Name: Drug Relief v1 Regulation Number: 21 CFR 882.5896
    Classification Name:
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Drug Relief v1 is a percutaneous nerve field stimulator (PNFS) system, that can be used as an aid to reduce the symptoms of opioid withdrawal, through application to branches of cranial nerves V, VII, IX and X, and the occipital nerves identified by transillumination.

    Device Description

    The Drug Relief v1 is a wearable, battery-operated device that is designed to administer periodical low level electrical pulses to the ear over five days / 120 hours from the time of activation of the device. The electrical pulse from the device will be delivered to the branches of cranial nerves on the ear through a set of wire assembly and stimulation needles. Three zinc air batteries with 1.4 V each provide the required stimulation energy for 120 hours. There are three stimulation electrode and one ground electrode which constitute of a titanium needle and lead/ wire with the snap-fit ring. The stimulation needles are inserted at three specific points, which have the ability to stimulate the cranial nerves. The ground electrode is inserted at one specific point (constant in all treatments) which forms the functional earthing to the device. The device is rectangular in shape and designed to fit comfortably on the neck. The biocompatible adhesive ensures that the device maintains contact with the skin during normal use. The adhesive fasteners ensure that the electrode needles and the entire device stay in place in a secure manner. This constant current source guarantees equivalent stimulation energy regardless of the individual impedance of the skin. The stimulation pattern consists of rectangular pulses with differing interpulse intervals. A 3-pin connector is provided, which is used to check the output voltage of the device once it is activated and before applying to the patient with any one of the voltage measuring devices available in the market with the appropriate regulatory compliance.

    AI/ML Overview

    The provided text describes the regulatory clearance of the "Drug Relief v1" device (K221231) by DyAnsys, Inc. It explicitly states that the device is substantially equivalent to a previously cleared predicate device, also named "Drug Relief v1" (K211971). The document primarily focuses on demonstrating this substantial equivalence rather than presenting an independent clinical study to prove the device meets specific performance criteria against a predefined ground truth in a clinical setting.

    Therefore, many of the requested items related to clinical study design, expert involvement, and statistical measures of performance (like effect size with AI assistance) are not directly applicable or available in this regulatory submission. The "acceptance criteria" discussed are largely in the context of demonstrating equivalence to the predicate and safety/performance through non-clinical testing.

    Here's an attempt to answer the questions based solely on the provided text, noting where information is not available:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly present a table of quantitative acceptance criteria and corresponding reported device performance against a clinical ground truth for the subject device (K221231). Instead, it focuses on demonstrating that the subject device has "equivalent performance specifications" and "identical fundamental technological and operational characteristics" to the predicate device (K211971). The "Performance Data" section discusses non-clinical testing.

    Acceptance Criteria (Implicit - related to predicate equivalence and non-clinical performance):

    Acceptance Criteria (Implicit)Reported Device Performance (K221231)
    Intended Use / Indications for Use: Identical to predicateIdentical to predicate: "aid to reduce the symptoms of opioid withdrawal, through application to branches of cranial nerves V, VII, IX and X, and the occipital nerves identified by transillumination."
    Technological Characteristics: Equivalent to predicate"identical intended use, indications for use, population, application of the device, environment of use" to predicate
    Product Dimensions (mm x mm x mm): 38 * 21 * 1038 * 21 * 10
    Mass (g): 8g (including battery)8g (including battery)
    Frequency (Hz): 1 - 101 - 10
    Waveform: Biphasic with Rectangular PulseBiphasic with Rectangular Pulse
    Battery Type: P13 Zinc Air batteries, non-rechargeableP13 Zinc Air batteries, non-rechargeable
    Battery Capacity: 310 mAh310 mAh
    No. x Voltage (V): 3 x 1.4 V3 x 1.4 V
    Pulse Width (ms): 0.9800.980
    Duty Cycle: 2 hours ON / 1 min OFF2 hours ON / 1 min OFF
    Typical Battery Operating Time (hours): 120120
    Operating Temperature: 5 °C to 45 °C5 °C to 45 °C
    Operating Humidity: 40% to 80%40% to 80%
    Environmental Use: Clinics, Hospital, HomeClinics, Hospital, Home
    Sterilization of Electrodes: EtO SterilizationEtO Sterilization
    Re-use: Single use DeviceSingle use Device
    Max Charge Density (µC / cm²) per needle: 67.16 @ 1 kΩ, 8.01 @ 10 kΩ67.16 @ 1 kΩ, 8.01 @ 10 kΩ
    Max Average Power Density (W / cm²): 0.363 @ 1 kΩ, 0.0516 @ 10 kΩ0.363 @ 1 kΩ, 0.0516 @ 10 kΩ
    Net Charge (µC per pulse): 0 (biphasic)0 (Due to biphasic nature of the waveform)
    Software Controlled: YesYes
    Shelf Life: Increased from 6 months (predicate) to 12 months12 months (demonstrated through sterilization and non-clinical performance testing)
    Biocompatibility: PassSubjected to biocompatibility testing (implied pass for clearance)
    Electrical Safety (EMC and safety): PassSubjected to electrical safety (electromagnetic compatibility and safety) testing (implied pass for clearance)
    Performance Bench Testing (120 hours continuous performance): Pass for pulse width, pulse duration, amplitude, current valuesFunctional test performed for 120 hours to monitor continuous performance. Captured pulse width, pulse duration, amplitude, and current values. Performance equivalent to predicate.
    Software Validation: PassSubjected to software validation (implied pass for clearance)

    2. Sample size used for the test set and the data provenance
    The document does not describe a clinical test set with human subjects or patient data. The "test set" discussed refers to non-clinical bench testing.

    • Sample size: Not specified for individual bench tests, but implies a sufficient number of devices were tested for validation.
    • Data provenance: Non-clinical bench testing data, likely conducted by DyAnsys, Inc.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
    Not applicable. There was no clinical test set requiring expert ground truth establishment for diagnostic performance.

    4. Adjudication method for the test set
    Not applicable. No clinical test set and no expert adjudication were described.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    Not applicable. This device is a nerve stimulator, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done
    Not applicable. This device is a nerve stimulator, not an algorithm. Its function is direct stimulation.

    7. The type of ground truth used
    For the non-clinical performance data, the "ground truth" was likely defined by engineering specifications and direct measurements against those specifications (e.g., measuring actual pulse width against the specified 0.980 ms). For establishing substantial equivalence, the "ground truth" was the characteristics, intended use, and indications for use of the predicate device (K211971).

    8. The sample size for the training set
    Not applicable. There is no mention of a training set for an algorithm in this submission.

    9. How the ground truth for the training set was established
    Not applicable. No training set was described.

    Ask a Question

    Ask a specific question about this device

    K Number
    K211971

    Validate with FDA (Live)

    Device Name
    Drug Relief v1
    Manufacturer
    Date Cleared
    2021-11-05

    (134 days)

    Product Code
    Regulation Number
    882.5896
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Boulevard San Mateo, CA 94401

    Re: K211971

    Trade/Device Name: Drug Relief v1 Regulation Number: 21 CFR 882.5896
    Classification Name
    Classification Name
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Drug Relief v1 is a percutaneous nerve field stimulator (PNFS) system, that can be used as an aid to reduce the symptoms of opioid withdrawal, through application to branches of cranial nerves V, VII, IX and X, and the occipital nerves identified by transillumination.

    Device Description

    The Drug Relief v1 is designed to be used as an aid to reduce opioid withdrawal symptoms by the method of cranial electrical stimulation at the auricular stimulation points. The Drug Relief v1 is a wearable, battery-operated device that is designed to administer periodical low level electrical pulses to the ear over five days / 120 hours from the time of activation of the device. The electrical pulse from the device will be delivered to the branches of cranial Nerves on the ear through a set of wire assembly and stimulation needles. Three zinc air batteries with 1.4 V each provide the required stimulation energy for 120 hours. There atimulation electrode and one ground electrode which constitute of a needle and lead/ wire with the snap-fit ring. The stimulation needles are inserted at three specific points, which have the ability to stimulate the cranial nerves. The ground electrode is inserted at one specific point (constant in all treatments) which forms the functional earthing to the device. This constant current source guarantees equivalent stimulation energy regardless of the individual impedance of the skin. The stimulation pattern consists of rectangular pulses with differing inter-pulse intervals and a duty cycle of 2 hours ON/1 minute OFF. A 3-pin connector is provided, which is used to check the output voltage of the device once it is activated and before applying to the patient with any one of the voltage measuring devices available in the market with the appropriate regulatory compliance.

    AI/ML Overview

    The provided text describes the Drug Relief v1 device and its substantial equivalence to a predicate device, Drug Relief (K173861). The document primarily focuses on demonstrating that the new device has similar performance specifications and safety characteristics to the previously cleared predicate.

    Here's an analysis of the provided information concerning acceptance criteria and studies:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of predetermined acceptance criteria with corresponding performance results. Instead, it relies on demonstrating that the "Drug Relief v1 has equivalent performance specifications when compared to the predicate device." This is a common approach for 510(k) submissions, where the new device's performance is compared to a legally marketed predicate rather than against absolute, pre-defined acceptance metrics for efficacy in a clinical setting.

    However, the core of the performance evaluation for this type of device, as indicated, revolves around:

    • Electrical Safety Parameters: Max Charge Density (µC/cm²) and Max Average Power Density (W/cm²).
    • Functional Performance: Pulse width, duty cycle, amplitude, and current values over the intended operating time (120 hours).
    • Biocompatibility: Ensuring materials are safe for patient contact.
    • Software Verification and Validation: Confirming the software functions as intended.
    • Sterilization: Achieving a defined sterility assurance level (SAL).

    The document states that the reported device performance for the Drug Relief v1 shows these characteristics are "identical or near identical" to the predicate device. Specifically, the electrical output parameters are presented in "Table 13.3.2 Comparison of Technical System Characteristics" (pages 6-7).

    System Characteristic / ParameterPredicate Device (Drug Relief K173861) PerformanceSubject Device (Drug Relief v1) PerformanceJustification / Outcome
    Max Charge Density (µC / cm²) per needle65.67 @ 1 kΩ; 7.96 @ 10 kΩ67.16 @ 1 kΩ; 8.01 @ 10 kΩNear identical; minor technological differences do not impact safety/effectiveness.
    Max Average Power Density (W / cm²)0.346 @ 1 kΩ; 0.0509 @ 10 kΩ0.363 @ 1 kΩ; 0.0516 @ 10 kΩNear identical; minor technological differences do not impact safety/effectiveness.
    Pulse ShapeRectangleRectangleIdentical
    Frequency (HZ)1 - 10 (Pulse with modulating frequency)1 - 10 (Pulse with modulating frequency)Identical
    WaveformRectangular PulseRectangle pulseIdentical
    Pulse Width (ms)0.9800.980Identical
    Duty Cycle2 hours ON / 1 min OFF2 hours ON / 1 min OFFIdentical
    Battery Operating Time (hours)120120Identical
    BiocompatibilityPassed (Implied, as K211971 passed)PassedDemonstrated via nonclinical testing.
    Electrical Safety (EMC and Safety)Passed (Implied, as K211971 passed)PassedDemonstrated via nonclinical testing, shown as "near identical" to predicate.
    Software Verification and ValidationPerformedPerformedDemonstrated via nonclinical testing.
    Sterility Assurance Level (SAL)Achieved (Implied, as K211971 passed)AchievedEvidenced by bio-burden, EtO sterilization, and sterility tests per ISO standards.

    2. Sample Size Used for the Test Set and Data Provenance

    The document describes nonclinical testing, including "performance bench testing" and "electrical safety (electromagnetic compatibility and safety)" for the Drug Relief v1 device (page 7). It also mentions "software verification and validation" and "biocompatibility testing."

    • Sample Size: The specific sample sizes for these tests (e.g., how many devices were tested for electrical safety or how many batches for sterilization) are not explicitly stated in the provided text.
    • Data Provenance: The studies are described as nonclinical (bench testing) and likely conducted by the manufacturer (DyAnsys, Inc.). There is no mention of clinical data, human subjects, country of origin related to human data, or retrospective/prospective study design, as this submission is based on demonstrating substantial equivalence through technical and performance comparisons to a predicate device.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable and not provided because the evaluation presented is based on nonclinical testing (bench tests, electrical safety, etc.) and direct comparison to a predicate device's technical specifications. There is no "ground truth" derived from expert interpretation of clinical data in this document.

    4. Adjudication Method for the Test Set

    This is not applicable and not provided as the submission does not involve clinical studies with human readers or diagnostic interpretations requiring adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This is not applicable and not provided. The Drug Relief v1 is a percutaneous nerve stimulator, not an AI-based diagnostic imaging or analysis device. There is no mention of human readers, AI assistance, or MRMC studies.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    This is not applicable and not provided. The device is a nerve stimulator, not an algorithm, and the submission does not refer to AI or algorithmic performance evaluation.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    As this is a nonclinical performance and electrical safety submission, the "ground truth" refers to established engineering standards, electrical measurement protocols, and material science specifications. For example:

    • Electrical Safety: Standards like those for current leakage, output parameters, and EMC.
    • Biocompatibility: ISO standards for biological evaluation of medical devices.
    • Sterilization: ISO standards for sterilization processes and sterility assurance.
    • Functional Performance: The established specifications of the predicate device (Drug Relief K173861) serve as the benchmark for "equivalent performance."

    8. The Sample Size for the Training Set

    This is not applicable and not provided, as there is no mention of an algorithm or AI model requiring a training set in this submission.

    9. How the Ground Truth for the Training Set was Established

    This is not applicable and not provided, for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201873

    Validate with FDA (Live)

    Date Cleared
    2021-01-02

    (179 days)

    Product Code
    Regulation Number
    882.5896
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    California 92110

    Re: K201873

    Trade/Device Name: Sparrow Therapy System Regulation Number: 21 CFR 882.5896
    Percutaneous nerve stimulator for substance use disorders |
    | Regulation Number: | 21 CFR 882.5896
    However, the submission demonstrated compliance to the Special Controls per 21 CFR 882.5896.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Sparrow is a transcutaneous nerve field stimulator that is intended to be used in patients experiencing opioid withdrawal in conjunction with standard symptomatic medications and other therapies for opioid withdrawal symptoms under the supervision of trained clinical personnel.

    Device Description

    The Sparrow Therapy System is a non-invasive, battery-operated, prescription device designed to transcutaneously stimulate nerves on and/or around the auricle to be used in patients experiencing opioid withdrawal in conjunction with standard symptomatic medications and other therapies for opioid withdrawal symptoms under the supervision of trained clinical personnel. The system includes three components: Earpiece, Patient Controller, and the Clinician Application. Sparrow is used in clinical environments (i.e., rehab centers and hospitals) and at home. Users of the subject device include experiencing opioid withdrawal symptoms.

    AI/ML Overview

    Here's a summary of the acceptance criteria and the study that proves the device meets them, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Key MetricAcceptance Criteria (Implied)Reported Device Performance (All Subjects, N=26)Reported Device Performance (Study Completers, N=14)
    COWS score percent reduction at 60 minutes≥15% reduction from baseline50.4%50.5%
    Percentage of patients who passed the naloxone challengeNot explicitly stated as acceptance criteria, but reported.10/26 (38.5%)10/14 (71.4%)
    Percentage of patients completing the studyNot applicable (outcome of study, not a performance metric)14/26 (53.8%)---
    Percentage of patients transitioning to MATNot explicitly stated as acceptance criteria, but reported.12/26 (46.2%)7/14 (50.0%)
    Prevalence of adverse events (AEs)Acceptable safety profile (no explicit numeric threshold)Documented and considered in benefit-risk analysisDocumented and considered in benefit-risk analysis
    Prevalence of serious adverse events (SAEs)Acceptable safety profile (no explicit numeric threshold)Documented and considered in benefit-risk analysisDocumented and considered in benefit-risk analysis
    Prevalence of adverse device events (ADEs)Acceptable safety profile (no explicit numeric threshold)Documented and considered in benefit-risk analysisDocumented and considered in benefit-risk analysis
    Prevalence of serious adverse device effects (SADEs)Acceptable safety profile (no explicit numeric threshold)Documented and considered in benefit-risk analysisDocumented and considered in benefit-risk analysis
    Prevalence of unanticipated serious adverse device effects (USADEs)Acceptable safety profile (no explicit numeric threshold)Documented and considered in benefit-risk analysisDocumented and considered in benefit-risk analysis
    Prevalence of device deficienciesAcceptable safety profile (no explicit numeric threshold)Documented and considered in benefit-risk analysisDocumented and considered in benefit-risk analysis

    Primary Effectiveness Endpoint and Acceptance Criteria:
    The primary effectiveness endpoint of the clinical study was a successful mean percent change in COWS score (defined as a ≥15% reduction) from baseline to 60 minutes after the start of active tAN therapy. The reported performance of 50.4% reduction for all subjects and 50.5% for study completers demonstrates that the device met this primary acceptance criterion.

    2. Sample Size Used for the Test Set and Data Provenance:

    • Sample Size: 26 participants (N=26) were enrolled in the study. 14 completed the study.
    • Data Provenance: Prospective. The study was conducted at one US site. The text indicates it was a "double-blind, randomized, prospective study."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    The document does not explicitly state the number or qualifications of experts used to establish the ground truth (COWS scores) for the test set. COWS (Clinical Opiate Withdrawal Scale) is a standardized tool, typically administered by trained clinical personnel. The study was conducted "under the supervision of trained clinical personnel," implying these professionals would have been responsible for assessing COWS scores.

    4. Adjudication Method for the Test Set:

    The document does not explicitly detail an adjudication method for the COWS scores or other assessments used in the test set. Given that COWS is a clinical assessment, it's typically performed directly by clinicians during the study visits.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve With AI vs Without AI Assistance:

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. The device, the Sparrow Therapy System, is a transcutaneous nerve stimulator, not an AI-based diagnostic or assistive software that involves human readers interpreting images or data. Therefore, the concept of human readers improving with AI assistance is not applicable to this device type.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

    The Sparrow Therapy System is a physical medical device (nerve stimulator) that delivers therapy. It operates independently as intended once activated, but its use is "under the supervision of trained clinical personnel." It is not an algorithm or software-only device where "standalone" performance in the absence of human input would be a relevant metric in the same way it would be for an AI diagnostic tool. However, the effectiveness study (reduction in COWS scores) represents the "standalone" performance of the device in its intended clinical setting in achieving the therapeutic effect.

    7. The Type of Ground Truth Used:

    The primary ground truth used for effectiveness was the Clinical Opiate Withdrawal Scale (COWS) score. This is a clinical assessment tool used to quantify the severity of opioid withdrawal symptoms.

    8. The Sample Size for the Training Set:

    The document does not mention a separate "training set" in the context of device development or clinical validation for the Sparrow Therapy System. This suggests that the clinical study described (with N=26 participants) served as the primary means of evaluating the device's effectiveness. For medical devices, particularly physical ones, a "training set" in the sense of machine learning algorithms is often not applicable unless the device incorporates complex adaptive algorithms. The device's design and stimulation parameters were likely developed through engineering and preclinical testing.

    9. How the Ground Truth for the Training Set Was Established:

    As no specific "training set" is mentioned in the context of clinical data for the device, this question is not directly applicable. If the device incorporates an adaptive algorithm, the methods for establishing ground truth for any data used to train such an algorithm would need to be described, but this information is not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K173861

    Validate with FDA (Live)

    Device Name
    Drug Relief
    Manufacturer
    Date Cleared
    2018-05-02

    (133 days)

    Product Code
    Regulation Number
    882.5896
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    San Mateo, California 94401

    Re: K173861

    Trade/Device Name: Drug Relief Regulation Number: 21 CFR 882.5896

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Drug Relief is a percutaneous nerve field stimulatory (PNFS) system, that can be used as an aid to reduce the symptoms of opioid withdrawal, through application to branches of Cranial Nerves V, VII, IX, and X, and the occipital nerves identified by transillumination.

    Device Description

    The Drug Relief™ is designed to aid in the treatment of opiate withdrawal symptoms by the method of electrical stimulation at the auricular stimulation points. The Drug Relief is a wearable, battery-operated device that is designed to administer periodical low-level electrical pulses to the ear over five days / 120 hours (2 hours ON/1 minute OFF) from the time of activation of the device. The electrical pulse from the device will be delivered to the branches of Cranial Nerves on the ear through a set of wire assembly and Stimulation needles. Three zinc air batteries with 1.4 V each provides the required stimulation energy for a maximum of 120 hours. There are three Stimulation electrodes and one ground electrode - which constitute of a needle and lead/ wire with the snap-fit ring. The stimulation needles are inserted at three specific points, which have the ability to stimulate the cranial nerves. The ground electrode is inserted at one specific point (constant in all treatments) which forms the functional earthing to the device. This constant current source guarantees equivalent stimulation energy regardless of the individual impedance of the skin. The stimulation pattern consists of rectangular pulses with differing inter-pulse intervals. A 3-pin connector is provided, which is used to check the output voltage of the device once it is activated and before applying to the patient with any one of the voltage measuring devices available in the market with the appropriate regulatory compliance.

    AI/ML Overview

    The provided text is a 510(k) summary for the medical device "Drug Relief," a percutaneous nerve stimulator for opioid withdrawal. This document focuses on demonstrating substantial equivalence to a predicate device (NSS-2 BRIDGE) rather than presenting a clinical study with detailed acceptance criteria and performance metrics for the device itself.

    Therefore, the information required to answer your request fully, particularly regarding specific acceptance criteria for "device performance" in a clinical setting, sample sizes for test sets, expert ground truth establishment, MRMC studies, and effect sizes, is not present in the provided document. The document primarily describes non-clinical performance and summarizes testing done to show equivalence to a predicate device.

    However, I can extract and present the available information to address as many of your points as possible:


    Summary of Acceptance Criteria and Device Performance (Based on Available Data)

    Based on the provided 510(k) summary, the "acceptance criteria" appear to be primarily focused on demonstrating substantial equivalence to the predicate device (NSS-2 BRIDGE) through performance testing of the device's electrical characteristics and compliance with recognized standards, rather than clinical efficacy metrics.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategoryReported Device Performance / Comparison to Predicate
    Electrical Performance
    Pulse Width0.980mSec (Equivalent to Predicate)
    Operating Time120 hrs (5 days), 2 Hours ON (Periodically) (Equivalent to Predicate)
    FrequencyPulses with modulating frequency (1 Hz - 10 Hz) (Equivalent to Predicate)
    WaveformRectangular pulse (Equivalent to Predicate)
    Max Charge Density (per needle)65.67 @ 1K ohm; 7.96 @ 10K ohm (Compared to Predicate: 48.91 @ 1K ohm; 5.79 @ 10K ohm)
    Max Average Power Density (per needle)0.346 @ 1K ohm; 0.0509 @ 10K ohm (Compared to Predicate: 0.2645 @ 1K ohm; 0.0371 @ 10K ohm)
    Output Voltage Measurement Feasibility3-pin connector provided to measure output voltage. (Feasible on subject device, not on predicate)
    Mechanical/Physical Equivalence
    Device ShapeRectangle (Equivalent to Predicate)
    Device AdhesiveFoam pad connected to adhesive – gel pad (Different from Tegaderm on predicate)
    Needle Dimensions0.42 mm (widthlength) (Slightly different from predicate: 0.5mm width x 2mm length)
    Wire Assembly4 units of wire with snap-fit ring (Different configuration than predicate)
    Sterilization MethodEtO Sterilization (Different from Irradiation (Gamma) on predicate)
    Shelf Life6 Months (Different from 12 months on predicate)
    Compliance with Standards
    Electrical SafetyIEC 60601-1 (Compliance stated)
    EMCIEC 60601-1-2 (Compliance stated)
    BiocompatibilityISO 10993 (Compliance stated for several parts)
    SterilizationISO 11135 and other related ISO standards (Compliance stated)
    Functional Performance
    Continuous PerformanceMonitored for 120 hours (Assumed to meet internal specifications for equivalence)
    Effectiveness"Validate the effectiveness of each unit" (Implied through functional test and comparison to predicate's "effectual output")

    Note: The document explicitly states that "These differences do not affect the safety and effectiveness of the device." This implies that the observed differences were deemed acceptable for substantial equivalence.

    2. Sample Sizes Used for the Test Set and Data Provenance

    • Test Set Sample Size: The document does not specify a sample size for a "test set" in the context of clinical performance or a human study. The "performance testing" described appears to be bench testing on the device units themselves.
    • Data Provenance: Not applicable as no clinical study data for device performance or efficacy is presented. The comparison is against the specifications of a predicate device.

    3. Number of Experts and Qualifications for Ground Truth

    • Not applicable. The ground truth for this submission is based on the technical specifications and performance of a legally marketed predicate device, and compliance with recognized standards. There is no mention of expert-established ground truth for clinical performance.

    4. Adjudication Method for the Test Set

    • Not applicable. No clinical test set requiring adjudication is described.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No evidence of an MRMC study. The document focuses on device characteristics and substantial equivalence, not on human reader performance with or without AI assistance. The device itself is a stimulate, not an AI diagnostic tool.

    6. Standalone (Algorithm Only) Performance

    • Not applicable for an AI algorithm. This device is a percutaneous nerve stimulator. Its "performance" is based on its electrical output and how it delivers stimulation. The summary states that "The Drug Relief device and its components are subjected to performance testing to validate the effectiveness of each unit." This describes a standalone device performance test, but not an algorithm's performance.

    7. Type of Ground Truth Used

    • The "ground truth" for this 510(k) submission is primarily:
      • Predicate Device Specifications: The technical and performance characteristics of the legally marketed predicate device (NSS-2 BRIDGE).
      • Industry Standards: Compliance with recognized international standards (IEC, ISO) for medical devices, electrical safety, EMC, biocompatibility, and sterilization.
      • Bench Testing Results: Measured electrical outputs and functional performance over time.

    8. Sample Size for the Training Set

    • Not applicable. This document describes a physical medical device, not a machine learning or AI model that requires a "training set."

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable. As above, there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    DEN170018

    Validate with FDA (Live)

    Device Name
    NSS-2 System
    Date Cleared
    2017-11-15

    (243 days)

    Product Code
    Regulation Number
    882.5896
    Type
    Direct
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    NEW REGULATION NUMBER: 21 CFR 882.5896

    CLASSIFICATION: Class II

    PRODUCT CODE: PZR

    BACKGROUND

    Device Type: Percutaneous nerve stimulator for substance use disorders Class: II Regulation: 21 CFR 882.5896

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NSS-2 BRIDGE is a percutaneous nerve field stimulator (PNFS) system, that can be used as an aid to reduce the symptoms of opioid withdrawal, through application to branches of Cranial Nerves V, VII, IX and X, and the occipital nerves identified by transillumination.

    Device Description

    NSS-2 BRIDGE is a device that electrically stimulates branches of Cranial Nerves V. VII. IX and X, and the occipital nerves identified by transillumination through percutaneous electrodes to aid in the reduction of opioid withdrawal symptoms. The device consists of (1) a percutaneous nerve field stimulator (PNFS; Figure 1), (2) a multi-pin wire harness percutaneous electrode array (Figure 2), and (3) a pen light for use in the transillumination technique that aids in positioning of the percutaneous electrodes (Figure 3).

    AI/ML Overview

    Acceptance Criteria and Study for NSS-2 BRIDGE

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific CriteriaReported Device Performance/Study Findings
    EffectivenessThe device, when used as an aid to reduce symptoms of opioid withdrawal, should demonstrate a clinically significant reduction in opioid withdrawal symptoms. A COWS score change of 15% for a given individual is considered clinically significant.Clinical Study Results: A single-arm, open label, multi-center retrospective study (n=73) demonstrated a significant reduction in COWS scores: - Baseline: Mean COWS score of 20.1 (±6.1) - 20 minutes post-placement: Mean COWS score reduced to 7.5 (±5.9), a 62.7% reduction (p<0.001 vs baseline) - 60 minutes post-placement: Mean COWS score reduced to 3.1 (±3.4), an 84.6% reduction (p<0.001 vs baseline) - Day 5 post-placement (subset n=33): Mean COWS score of 0.6, a 97.1% reduction (p<0.001 vs baseline) - Overall: 100% (73/73) subjects had a reduction in COWS scores by 30 minutes with a minimum decrease of at least 31%. At 60 minutes, 78% (57/73) had withdrawal scores of ≤3. - MAT Transition: 88.8% (64/73) successfully transitioned to medically assisted therapy (MAT).
    Safety- Biocompatibility for patient-contacting materials. - Compliance with electrical, mechanical, and thermal safety standards. - Sterility of percutaneous components. - Absence of significant adverse events.- Biocompatibility: Biocompatibility information was leveraged from the previously cleared EAD device (K140530) for most patient-contacting materials (fixation plasters, foam adhesive, metal of electrode arrays). No additional testing was required for changes in electrode configuration or housing material due to the non-patient-contacting nature of the housing with the adhesive. - Electrical/Mechanical/Thermal Safety: Conformed to IEC 60601-1, IEC 60601-1-2, and IEC 60601-2-10 (leveraged from K140530). - Sterility: Sterilization Validation conducted using VDMAX25 method according to ISO 11137-2:2007 demonstrated SAL of 10^-6. Fulfilled requirements of ISO 11737-2:2009. - Adverse Events (Clinical Study): No adverse events were recorded in any subject (n=73) during the entire time of neurostimulation. - Adverse Events (Retrospective Chart Review): A separate retrospective chart review of 1207 PNFS devices (19312 punctures) across 6 US sites for various indications reported: bleeding (n=11), pain (n=2), dermatitis (n=11). All resolved spontaneously upon device removal. No infections noted for this device.
    Performance (Bench)- Verification of temporal characteristics and amplitude of pulse train. - Verification of pulse train duty cycle. - Verification of maximum operating time (120 hours).- Additional electrical bench testing (leveraged from K140530) was performed under 1kΩ resistance. - Successfully verified new output duty cycle and pulse characteristics for NSS-2 BRIDGE. - Successfully verified temporal characteristics and amplitude of the pulse train. - Successfully verified that the device does not exceed maximum operating time of 120 hours.
    Software- Software verification and validation (for "Minor" level of concern).- Software information leveraged from K140530. - Additional software verification successfully performed for NSS-2 BRIDGE to verify the new output duty cycle performed as specified (2 hours on, 1 minute off, repeating over 120 hours). Software was considered "Minor" level of concern.
    Shelf Life/Packaging- Continued sterility, package integrity, and device functionality over specified shelf life.- Shelf life and sterility information leveraged from K140530 as no changes to sterilization method, shelf life, or packaging. - Validation of packaging system performed per ISO 11607-1:2009 and ASTM F1980-07:2011 (accelerated aging).
    Use Environment- Splash-proof, not watertight.- Stated limitation: "The appliance is splash-proof but not watertight. When showering, the device must not be allowed to come into direct contact with water." (This is a design characteristic, implicitly met if labeling reflects it).

    2. Sample Size for Test Set and Data Provenance

    • Sample Size: 73 patients.
    • Data Provenance: Retrospective study. Data was collected from participating outpatient drug treatment clinics located across five US states: St. Louis, MO (27 patients), Liberty, IN (13), Florence, KY (12), Anchorage, AK (9), Rising Sun, IN (6), Richmond, IN (2), Dayton, OH (2), and Indianapolis, IN (2).

    3. Number of Experts and Qualifications for Ground Truth

    The study does not mention the use of experts to establish ground truth for the test set. The ground truth for opioid withdrawal symptoms was established through the Clinical Opioid Withdrawal Scale (COWS) scores, which were recorded as part of the treatment protocol in the participating clinics. These scores are obtained by medical professionals (e.g., clinicians, nurses), but the study does not specify their exact qualifications or the number of individuals involved in scoring each patient. The COWS is a standardized, subjective assessment tool.

    4. Adjudication Method for the Test Set

    The study does not mention any specific adjudication method for the COWS scores in the test set. Scores were "recorded" and "extracted from the medical chart," implying a single assessment per time point per patient.

    5. Multi Reader Multi Case (MRMC) Comparative Effectiveness Study

    No, a Multi Reader Multi Case (MRMC) comparative effectiveness study was not done. The study was a single-arm, open-label retrospective study, evaluating the device's effect without a direct comparison to human readers' performance with and without AI assistance or a control group receiving no intervention/placebo in the same manner.

    6. Standalone (Algorithm Only) Performance Study

    No, a standalone (algorithm only) performance study was not done. The device (NSS-2 BRIDGE) is a hardware device that electrically stimulates nerves; it does not involve an AI algorithm to analyze data or provide a diagnosis. Its performance is directly tied to its physical application and electrical stimulation.

    7. Type of Ground Truth Used

    The ground truth used was expert assessment using a standardized clinical scale, specifically the Clinical Opioid Withdrawal Scale (COWS). The COWS is a widely recognized tool for assessing the severity of opioid withdrawal symptoms, typically administered by trained healthcare professionals. While not "pathology" or "outcomes data" in the direct sense of a biological marker, it represents a clinical judgment based on observable signs and reported symptoms.

    8. Sample Size for the Training Set

    The document does not define a "training set" in the context of this device's effectiveness study. The NSS-2 BRIDGE is a medical device, not an AI/machine learning algorithm requiring a distinct training phase with a dedicated dataset. The clinical study described served as the primary evidence for its efficacy for regulatory purposes.

    9. How the Ground Truth for the Training Set Was Established

    As there was no distinct "training set" for an AI/ML algorithm, this question is not applicable. The device's mechanism of action is electrical stimulation, not a learned algorithm.