510(k) Data Aggregation

    K Number
    K200126

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-05-22

    (122 days)

    Product Code
    Regulation Number
    880.2800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K162701, as modified under K181422. (21 CFR 880.2805, OWP)

    4.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The VERIFY Assert Self-Contained Biological Indicator (SCBI) is for routine monitoring, qualification testing, load monitoring and product testing of the following steam sterilization processes.

    Cycle TypeTemperatureTime
    Dynamic Air Removal270°F (132°C)4 minutes
    Dynamic Air Removal275°F (135°C)3 minutes
    Gravity250°F (121°C)30 minutes
    Gravity270°F (132°C)15 minutes

    When used in conjunction with the Reader for the VERIFY Assert Self-Contained Biological Indicator, the VERIFY Assert Self-Contained Indicator provides a fluorescent result within 40 minutes

    Device Description

    The product is intended to monitor the critical parameters of steam sterilization cycles described in the indications for use by producing an optical change (signal) that is detected by the STERIS proprietary reader, VERIFY Incubator for Assert Self-Contained Biological Indicator, in 40 minutes to confirm the viability of the biological indicator at the end of a steam sterilization process. The product consists of a biological organism known to be resistant to steam (Geobacillus stearothermophilus) and a defined nutrient media. A reporter enzyme, which is produced by the organism, reacts with a fluorogenic substrate within the defined nutrient media to produce a fluorescent moiety.

    AI/ML Overview

    The STERIS Corporation VERIFY Assert Self-Contained Biological Indicator (SCBI) is a Class II device (21 CFR 880.2800, Product code FRC) intended for monitoring steam sterilization processes.

    Here's an analysis of its acceptance criteria and the study proving its performance:


    1. Table of Acceptance Criteria and Reported Device Performance

    TestPurpose of the TestAcceptance CriteriaReported Device PerformanceConclusion
    Reduced Incubation Time (RIT) TestingValidate the labeled incubation time of the SCBIMeets FDA's requirement of > 97% alignment of the 40-minute results with the conventional incubation time of 7 days*, ‡Not explicitly quantified in this section, but stated to "PASS"PASS
    Viable spore populationEnumerate the number of viable spores per SCBI1.0 - 4.0 x 10^6 spore/SCBI**, ‡2.7 - 3.7 x 10^6 spore/SCBIPASS
    ResistanceDetermine the resistance of the SCBI to steamD121 ≥ 1.5 min *D132 ≥ 10 s *D135 ≥ 8 s *D121 ≥ 2.13 minD132 ≥ 42 sD135 ≥ 31 sPASS
    Signal GenerationValidate that the SCBI will produce signal in its readerAll unexposed SCBI show positive growth signal in reader within 40 minutes of incubation‡Not explicitly quantified in this section, but stated to "PASS"PASS
    Hold TimeDemonstrate that performance of the SCBI is not affected by delaying incubation up to 72 hoursPerformance not affected if incubated within 72 hours of exposure to steam sterilization‡Not explicitly quantified in this section, but stated to "PASS"PASS
    Simulated UseDemonstrate SCBI performance in a steam sterilizer with the AAMI reference load (16 towel pack)Demonstrate growth when exposed to abbreviated cycle and all kill in a full cycle‡Abbreviated cycle – growthFull cycle – no growthPASS

    Notes on Acceptance Criteria:

    • *: Based on recommendations in FDA Guidance Biological Indicator (BI) Premarket Notification [510(k)] Submissions
    • **: Minimum acceptance criteria based on recommendations in FDA Guidance Biological Indicator (BI) Premarket Notification [510(k)] Submissions
    • : Based on specifications of the reference device, VERIFY Assert Self-Contained BI

    2. Sample size used for the test set and the data provenance

    The document does not explicitly state the specific sample sizes used for each non-clinical test (e.g., number of SCBIs tested for RIT, viable spore population, etc.). It only provides the acceptance criteria and the conclusion (PASS) or the measured performance range.

    The data provenance is from non-clinical testing conducted by STERIS Corporation for their VERIFY Assert Self-Contained Biological Indicator. This would inherently be prospective data collection as it's part of a device validation study. The country of origin of the data is not specified, but the applicant (STERIS Corporation) is based in Mentor, Ohio, USA.


    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This device is a biological indicator for sterilization processes. The "ground truth" for its performance is established through laboratory testing against well-defined, standardized sterilization parameters and biological growth assessment, rather than expert human interpretation of images or clinical data. Therefore, the concept of "experts establishing ground truth for a test set" in the context of interpretation of results (like in a medical imaging AI study) does not directly apply here. The "experts" involved would be the microbiologists and engineers who designed, executed, and analyzed the validation studies, ensuring adherence to standards like those outlined in FDA guidance documents and AAMI. Their qualifications would typically involve expertise in microbiology, sterilization science, and quality assurance for medical devices.


    4. Adjudication method for the test set

    Not applicable. As explained above, the "ground truth" is determined by objective biological and physical measurements and adherence to established scientific and regulatory standards for sterilization indicators, not by a panel of human adjudicators.


    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a biological indicator, not an AI-powered diagnostic tool requiring human interpretation. Its function is to provide an objective fluorescent signal detected by a reader to indicate sterilization success or failure.


    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Yes, in a way. The performance testing described is essentially a "standalone" assessment of the device's ability to accurately indicate sterilization conditions. The VERIFY Assert SCBI, when used with its proprietary reader, provides a fluorescent result within 40 minutes. This means the device itself, in conjunction with its automated reader, generates the result without human interpretation of a complex output. The human role is to observe the positive or negative signal from the reader. The tests confirm the device's intrinsic biological resistance and signal generation properties under various sterilization conditions and incubation parameters.


    7. The type of ground truth used

    The ground truth used for this device is based on:

    • Microbiological Growth Assessment: Direct observation of bacterial growth (or lack thereof) after exposure to sterilization cycles, often confirmed by conventional incubation methods (e.g., 7 days of incubation) to establish true viability.
    • Physical and Biological Standards: Adherence to established performance metrics ($D_{value}$, spore population) defined by regulatory guidance (FDA Guidance Biological Indicator (BI) Premarket Notification [510(k)] Submissions) and industry consensus standards (e.g., AAMI for sterilization processes).
    • Controlled Sterilization Cycles: Exposure to precisely controlled steam sterilization cycles (e.g., abbreviated cycles to show growth, full cycles to show kill) to challenge the BI.

    8. The sample size for the training set

    Not applicable. This device is a biological indicator and does not employ machine learning or AI algorithms that would require a "training set." Its biological and chemical principles of operation are deterministic, based on the survival and metabolic activity of a target microorganism.


    9. How the ground truth for the training set was established

    Not applicable, as there is no "training set" for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K181442

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2018-06-13

    (12 days)

    Product Code
    Regulation Number
    880.2805
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K181442

    Trade/Device Name: VERIFY Assert Self-Contained Biological Indicator Regulation Number: 21 CFR 880.2805
    Classification Name: | Biological Sterilization Process Indicator withRecombinant-DNA Plasmid (21 CFR 880.2805
    and performs as well or better than the legally marketed predicate device, K162701 Class II (21 CFR 880.2805

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The VERIFY Assert Self-Contained Biological Indicator (SCBI) is for routine monitoring, qualification testing and product testing of the following steam sterilization processes.

    Cycle TypeTemperatureTime
    Dynamic Air Removal270°F (132°C)4 minutes
    Dynamic Air Removal275°F (135°C)3 minutes
    Gravity250°F (121°C)30 minutes
    Gravity270°F (132°C)15 minutes

    When used in conjunction with the Reader for the VERIFY Assert Self-Contained Biological Indicator, the VERIFY Assert Self-Contained Indicator provides a fluorescent result within 40 minutes

    Device Description

    The product is intended to monitor the critical parameters of steam sterilization cycles described in the indications for use by producing an optical change (signal) that is detected by the STERIS proprietary reader, VERIFY Incubator for Assert Self-Contained Biological Indicator, in 40 minutes to confirm the viability of the biological indicator at the end of a steam sterilization process. The product consists of a biological organism known to be resistant to steam (Geobacillus stearothermophilus) and a defined nutrient media. A reporter enzyme, which is produced by the organism, reacts with a fluorogenic substrate within the defined nutrient media to produce a fluorescent moiety.

    AI/ML Overview

    The provided document, a 510(k) premarket notification for the VERIFY Assert Self-Contained Biological Indicator, details the device's technical characteristics and nonclinical testing. However, it does not describe a study involving an AI-powered medical device or human readers. Therefore, much of the requested information cannot be extracted from this specific document.

    Here's the information that can be extracted or inferred based on the document's content, formatted as requested:

    1. A table of acceptance criteria and the reported device performance

    TestAcceptance CriteriaReported Device Performance
    Simulated UseBI is inactivated when exposed in a worst-case cycle with a worst-case loadNo growth of BI

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    The document does not specify the sample size for the "Simulated Use" test, nor does it provide details about the data provenance (e.g., country of origin, retrospective/prospective). It only states that performance testing "has been completed" and is summarized.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. This device is a biological indicator for sterilization, not an imaging or diagnostic device requiring expert review for ground truth. The "ground truth" for this device's function is the biological outcome (growth or no growth of the biological indicator) after exposure to sterilization conditions.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not applicable. There's no human interpretation or adjudication described for the biological indicator's performance. The outcome is a direct biological observation (fluorescence, indicating growth, or lack thereof).

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This document describes a biological indicator, not an AI-powered device or a study involving human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. The device is a biological indicator. Its operation involves a "VERIFY Incubator for Assert Self-Contained Biological Indicator" which detects a fluorescent result, suggesting an automated readout. However, this is not an "algorithm only" performance in the context of AI without human-in-the-loop diagnosis or interpretation. The device itself is the indicator, and the incubator provides an automated reading of its state.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The ground truth for this device's performance is the biological outcome: inactivation (no growth) of the Geobacillus stearothermophilus spores after exposure to sterilization conditions, or growth when not adequately sterilized. This is determined by observing fluorescence, which indicates enzymatic activity from viable spores.

    8. The sample size for the training set

    Not applicable. This is not an AI/machine learning device that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable. This is not an AI/machine learning device that requires a training set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K162945

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2017-04-28

    (189 days)

    Product Code
    Regulation Number
    880.2805
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K162945

    Trade/Device Name: Verify Assert Steam Process Challenge Device Regulation Number: 21 CFR 880.2805

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The VERIFY™ Assert™ STEAM Process Challenge Device (PCD) is used for qualification, routine microbial monitoring, and load monitoring of steam sterilizers.

    The validated steam sterilization cycles include:

    • 270°F (132°C) 4-minute dynamic air removal
    • 275°F (135°C) 3-minute dynamic air removal
    Device Description

    Not Found

    AI/ML Overview

    This document is a 510(k) clearance letter for a medical device (VERIFY Assert STEAM Process Challenge Device) and an "Indications for Use" statement. It does not contain information about acceptance criteria, study details, or device performance against those criteria. Therefore, I cannot extract the requested information from this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K163587

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2017-03-24

    (94 days)

    Product Code
    Regulation Number
    880.2805
    Age Range
    12 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Device Name: Verify Incubator For Assert Self Contained Biological Indicators Regulation Number: 21 CFR 880.2805
    |
    | Classification Name: | Recombinant Biological Indicator(21 CFR 880.2805
    equivalent and is as safe and as effective as the legally marketed predicate device Class II (21 CFR 880.2805

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Use the VERIFY® Incubator for Assert™ Self Contained Biological Indicators SCBI (Incubator) to incubate and automatically read VERIFY Assert Self-Contained Biological Indicators at 57 °C for a fluorescent result within 40 minutes.

    Device Description

    The VERIFY® Incubator for Assert™ Self Contained Biological Indicators (Incubator) is an incubator/reader designed for use specifically with the VERIFY Assert Self-Contained Biological Indicator (SCBI), see K162701, currently under review. The incubator/reader provides a constant temperature range to allow for activation and outgrowth of Geobacillus stearothermophilus leading to production of a fluorescent moiety. The presence of an increasing fluorescence signal due to increasing concentrations of this fluorescent moiety in the SCBI is detected by the incubator/reader and indicates the presence of viable test microorganisms.

    AI/ML Overview

    The document provided describes the "VERIFY® Incubator for Assert™ Self Contained Biological Indicators" and its nonclinical testing to demonstrate substantial equivalence to a predicate device. This device is an incubator/reader used to incubate and automatically read self-contained biological indicators for sterilization processes.

    Here's a breakdown of the acceptance criteria and study proving the device meets them:

    1. Table of Acceptance Criteria and the Reported Device Performance:

    TestAcceptance CriteriaReported Device Performance (Conclusion)
    Maintenance of Incubation TemperatureMaintain 55-60 °C for a minimum of 40 minutes (incubation time of Verify Assert SCBI as stated in K162701)PASS
    Qualification testing with Verify Assert SCBI40-minute fluorescent read meets >97% alignment with 7-day growth results per FDA guidance on reduced incubation time.PASS
    Qualification testing with Verify Assert SCBIPass testing with SCBI exposed to full cycle exposure and negative growth result in incubator.PASS
    Qualification testing with Verify Assert SCBIFail testing with SCBI exposed in abbreviated cycle exposure and positive result in incubator.PASS
    Alarm, LED and Print function TestDemonstrate proper function of alarms, LED and print outputs.PASS

    Study Proving the Device Meets Acceptance Criteria:

    The document describes nonclinical performance testing.

    2. Sample size used for the test set and the data provenance:

    • Sample Size: The document does not explicitly state the specific number of biological indicators (sample size) used for the qualification testing. It refers to "testing with SCBI exposed to full cycle exposure" and "testing with SCBI exposed in abbreviated cycle exposure," implying multiple indicators were tested.
    • Data Provenance: The document doesn't specify the country of origin for the data. Given it's a submission to the FDA (United States), it is highly likely the testing was conducted in the USA or by a facility adhering to US regulations. The testing is described as "performance testing," which typically refers to prospectively collected data for validation purposes.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    This device is an incubator/reader for biological indicators. The "ground truth" for this type of device is the actual growth or non-growth of microorganisms in the biological indicator, determined through traditional microbiological culturing methods (e.g., 7-day growth results for biological indicators). There is no mention of human experts (like radiologists) being involved in establishing the ground truth for this specific device, as its function is to automate the reading of a biological indicator. The "7-day growth results" serve as the objective ground truth.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    Not applicable. The ground truth is based on the biological end-point (microbial growth/no growth), not subjective human interpretation requiring adjudication.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable. This device is an automated incubator/reader for biological indicators, not an AI-assisted diagnostic imaging device that involves human reader interpretation. No human readers are involved in the "reading" process of this device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Yes, this is effectively a standalone performance study. The device itself (the incubator/reader) provides the fluorescent read, which is then compared against the established biological "truth" (7-day growth results). Its primary function is automated reading without human interpretation of its output beyond acknowledging the alarm or visual indicator.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The ground truth used is the microbiological growth status of the biological indicators, specifically the "7-day growth results." This is an objective measurement of whether the microorganisms in the biological indicator proliferated or not, which is the definitive indicator of sterilization effectiveness.

    8. The sample size for the training set:

    Not applicable. This document describes a traditional medical device (an incubator/reader) validated through performance testing, not a machine learning or AI-based device that typically requires a separate training set. The device's "knowledge" is built into its design (temperature control, fluorescence detection) rather than learned from a data set.

    9. How the ground truth for the training set was established:

    Not applicable, as there is no training set mentioned for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K162701

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2017-03-24

    (177 days)

    Product Code
    Regulation Number
    880.2805
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K162701

    Trade/Device Name: VERIFY Assert Self-Contained Biological Indicator Regulation Number: 21 CFR 880.2805
    |
    | Classification Name: | Recombinant Biological Indicator (21 CFR 880.2805
    equivalent and is as safe and as effective as the legally marketed predicate device Class II (21 CFR 880.2805

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The VERIFY Assert Self-Contained Biological Indicator (SCBI) is for routine monitoring, qualification testing and product testing of the following steam sterilization processes.

    Cycle TypeTemperatureTime
    Dynamic Air Removal270°F (132°C)4 minutes
    Dynamic Air Removal275°F (135°C)3 minutes
    Gravity250°F (121°C)30 minutes
    Gravity270°F (132°C)15 minutes

    When used in conjunction with the Reader for the VERIFY Assert Self-Contained Biological Indicator, the VERIFY Assert Self-Contained Indicator provides a fluorescent result within 40 minutes.

    Device Description

    The product is intended to monitor the critical parameters of steam sterilization cycles described in the indications for use by producing an optical change (signal) that is detected by the STERIS proprietary reader, Incubator for VERIFY Assert Self-Contained Biolgoical Indicator in 40 minutes to confirm the viability of the biological indicator at the end of a steam sterilization process. The product consists of a biological organism known to be resistant to steam (Geobacillus stearothermophilus) and a defined nutrient media. A reporter enzyme, which is produced by the organism, reacts with a fluorogenic substrate within the defined nutrient media to produce a fluorescent moiety.

    AI/ML Overview

    The document describes the VERIFY Assert Self-Contained Biological Indicator (SCBI) for monitoring steam sterilization processes. The acceptance criteria and testing are detailed for this device.

    1. Table of Acceptance Criteria and Reported Device Performance:

    TestAcceptance CriteriaReported Device Performance
    Reduced Incubation Time (RIT) TestingMeets FDA's requirement of > 97% alignment of the 40-minute results with the conventional incubation time of 7 daysPASS
    Viable spore population1.0 - 4.0 x 10^6 spore/SCBI1.6 - 1.9 x 10^6 spore/SCBI
    ResistanceD121 ≥ 1.5 minD132 ≥ 10 sD135 ≥ 8 sD121 ≥ 2.29 minD132 ≥ 49 sD135 ≥ 40 s
    Survival TimeMeets the longer of FDA and ISO 11138-3 requirements121 C ≥ 9.81 min132 C ≥ 3.51 min135 C ≥ 2.83 min
    Kill TimeMeets the shorter of FDA and ISO 11138-3 requirements121 C ≤ 25.57 min132 C ≤ 9.21 min135 C ≤ 7.73 min
    Carrier growth inhibition / media growth promotionPositive growth of less than 100 spores after primary packaging and media are subject to worst-case steam exposurePASS
    Hold TimePerformance not affected if incubated within 72 hours of exposure to steam sterilizationPASS
    Simulated UseDemonstrate growth when exposed to abbreviated cycle and all kill in a full cycleAbbreviated cycle - growthFull cycle - no growth
    Process indicatorMeets requirements for a “Class 1” process indicator of ISO 11140-1:2005PASS (Testing provided in K112256)

    The provided document is a 510(k) summary for a medical device (Biological Indicator) and lacks specific information regarding studies involving AI, human readers, or image analysis. Therefore, the following sections will indicate that the information is not applicable based on the content.


    2. Sample Size Used for the Test Set and Data Provenance:

    The document describes performance testing for biological indicators used in sterilization. It does not refer to "test sets" in the context of AI/machine learning or human reader studies. The data provenance is laboratory testing related to the performance of biological indicators under specific conditions rather than patient data. Specific sample sizes for each test are not explicitly detailed in the summary, but the resistance and population values are quantitative measurements of the device itself rather than data collected from a large number of 'samples' in the sense of a clinical trial. The testing is likely prospective and conducted in a controlled laboratory environment.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    Not applicable. This device is a biological indicator, and its performance is determined through standardized laboratory tests (e.g., spore count, D-value determination, growth/no growth observation) rather than interpretation by human experts.

    4. Adjudication Method for the Test Set:

    Not applicable. The determination of device performance (e.g., whether spores are killed, whether a fluorescent signal is produced) is based on objective laboratory measurements and biological principles, not expert adjudication.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable. This document pertains to a biological indicator for sterilization monitoring, not an AI-powered diagnostic or interpretive device involving human readers.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    Not applicable. The device itself is a biological indicator. Its "performance" involves a chemical/biological reaction monitored by a specific reader, but this is not an "algorithm" in the context of standalone AI performance. The reader provides a fluorescent result.

    7. The Type of Ground Truth Used:

    The ground truth for the device's performance is established by:

    • Biological Viability: The presence or absence of viable Geobacillus stearothermophilus spores after exposure to sterilization conditions.
    • Fluorescent Signal: The detection of a fluorescent moiety produced by the organism's enzyme reacting with a substrate, indicating viability.
    • Standardized Test Methods: Adherence to established standards like ISO 11138 and FDA guidance for biological indicators.
    • Quantitative Measurements: D-values (decimal reduction time), survival time, kill time, and spore population counts based on microbiological assays.

    8. The Sample Size for the Training Set:

    Not applicable. This document does not describe an AI/machine learning model that requires a training set. The device is a physical biological indicator.

    9. How the Ground Truth for the Training Set was Established:

    Not applicable, as no training set for an AI model is described.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1