510(k) Data Aggregation

    K Number
    K231939

    Validate with FDA (Live)

    Device Name
    Renasys Edge
    Date Cleared
    2024-05-24

    (329 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    |
    | Regulation Number | 21 CFR 878.4783

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RENASYS™ EDGE pump is indicated for patients who would benefit from a suction pump (NPWT), as it may promote wound healing via removal of fluids, including irrigation fluids, wound exudate and infectious materials. Appropriate wound types include:

    • Chronic
    • · Acute
    • · Traumatic
    • Sub-acute and dehisced wounds
    • · Ulcers (such as pressure or diabetic)
    • · Partial-thickness burns
    • · Flaps
    • Grafts

    The RENASYS™ EDGE pump is compatible with the following accessory dressing kits:

    • RENASYS™ Foam Dressing Kits
    • · RENASYS™ Foam Dressing Kit XL
    • · RENASYS™ Gauze Dressing Kits
    • · RENASYSTM Abdominal Dressing Kit
    • · RENASYS™ Y Connector Kit
    • · RENASYSTM White Foam Wound Dressing

    When used with the RENASYS™ AB Abdominal Kit with Soft Port, the RENASYS EDGE™ pump is indicated for temporary bridging of abdominal wall openings where primary closure is not possible and/or repeat abdominal entries are necessary. It is intended to be used in open abdominal wounds with exposed viscera, including but not limited to abdominal compartment syndrome. The use of RENASYS™ AB Abdominal Kit with Soft Port is intended for use in acute hospital care settings (trauma, general and plastic surgery wards) and should ideally be applied in the operating theatre.

    Device Description

    The RENASYS™ EDGE device is a software controlled suction device consisting of an electric motor driven, diaphragm, vacuum pump. The device is designed to provide Negative Pressure Wound Therapy at a range of pressure settings between 25-200mmHg to a closed environment over one or two wounds. The device removes exudate from the wound site(s) to a disposable container, which may promote wound healing via removal of fluids, including irrigation of body fluids, wound exudates and infectious materials.

    RENASYS™ EDGE can be operated by either a mains power supply or internal battery. The RENASYS™ EDGE device is compatible with Smith & Nephew RENASYS™ Dressing Kits.

    AI/ML Overview

    The provided text is a 510(k) summary for the RENASYS™ EDGE device. This document focuses on demonstrating substantial equivalence to a previously cleared device, not an AI/ML powered device, and thus does not contain the information requested in points 1, 2, 3, 4, 5, 6, 7, 8, and 9 of the prompt, which are typically associated with performance studies for AI/ML medical devices.

    The submission is specifically for adding "RENASYS™ White Foam dressing kits" as compatible accessories to the existing RENASYS™ EDGE negative pressure wound therapy system. It explicitly states: "No clinical data was provided to support the demonstration of substantial equivalence."

    Instead, the document details non-clinical tests performed to demonstrate that the overall system performance of the RENASYS™ EDGE device is not impacted by the use of the new dressing. These tests are:

    • Simulated wound model tests: To ensure satisfactory performance, including fluid management and Negative Pressure Wound Therapy (NPWT) delivery.
    • EMC Testing: In accordance with IEC 60601-1-2 and RTCA DO-160G.
    • Cybersecurity testing: In accordance with FDA guidance "Content of Premarket Submissions for Device Software Functions Guidance for Industry and Food and Drug Administration Staff".
    • Software design and testing: In accordance with the framework set out in IEC 62304:2006.
    • Low air pressure environment testing: EMC testing (RTCA DO-160G) and NPWT wound model testing were carried out to support the new environment for use (aircraft).

    Therefore, I cannot provide a response for the requested information regarding acceptance criteria, device performance tables, sample sizes, expert ground truth, adjudication methods, MRMC studies, standalone performance, ground truth types, or training set details, as this information is not present in the provided document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K223263

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-02-13

    (112 days)

    Product Code
    Regulation Number
    878.4783
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Device

    Trade/Device Name: Prevena™ Plus 125 Therapy Unit Regulation Number: 21 CFR 878.4783 Regulation

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Prevena Plus 125 Therapy Unit is indicated for use with both the Prevena™ Dressings and compatible V.A.C.® Dressings.

    The Prevena Plus 125 Therapy Unit when used with the Prevena™ Dressings (Prevena Plus Incision Management System), manages the environment of closed surgical incisions and removes fluid away from the surgical incision via the application of -125mmHg continuous negative pressure. When used with legally marketed Prevena Dressings for up to seven days, Prevena Plus 125 Therapy Units are intended to aid in reducing the incidence of seroma and, in patients at high risk for post-operative infections, aid in reducing the incidence of superficial surgical site infection in Class I and Class II wounds.

    The Prevena ™ Plus 125 Therapy Unit, when used with compatible V.A.C.® Dressings on open wounds (Prevena Plus Negative Pressure Wound Therapy System), is intended to create an environment that promotes wound healing by secondary or tertiary (delayed primary) intention by preparing the wound bed for closure, reducing edema, promoting granulation tissue formation and by removing exudate and infectious material. Open wound types include: chronic, acute, traumatic, subacute and dehisced wounds, partial-thickness burns, ulcers (such as diabetic, pressure or venous insufficiency), flaps and grafts.

    Device Description

    The Prevena™ Plus 125 Therapy Unit may be used part of as either of these systems:

    A) Prevena Incision Management System Consist of:

    • Prevena™ Therapy Unit .
    • Prevena 150mL Canister & adaptor .
    • Prevena Dressing kit ●

    B) Prevena Plus Negative Pressure Wound Therapy System Consist of:

    • Prevena™ Plus 125 Therapy Unit .
    • Prevena 150mL Canister & adaptor .
    • V.A.C. Dressing kit ●

    The Prevena™ Plus Incision Management System (Prevena™ Plus Therapy Unit when used with Prevena Dressings) is designed for use over linear, non-linear, intersecting incisions.

    The Prevena™ Plus Negative Pressure Wound Therapy System (Prevena™ Plus Therapy Unit when used with V.A.C. Dressings) is designed for use in a variety of open wound types such as: chronic, acute, traumatic, subacute and dehisced wounds, partial-thickness burns, ulcers (such as diabetic, pressure or venous insufficiency), flaps and grafts.

    The Prevena Plus 125 Therapy Units are negative pressure pumps that deliver -125mmHg continuously for up to 7 or 14 days.

    AI/ML Overview

    The provided text is a 510(k) premarket notification summary for the Prevena Plus 125 Therapy Unit. It describes the device's indications for use, comparison to predicate devices, and performance data. However, it does not include a detailed study proving that the device meets specific acceptance criteria in the way typically required for AI/ML-driven medical devices.

    Instead, this document focuses on demonstrating substantial equivalence to previously cleared predicate devices. The performance data presented refers to non-clinical tests and human factors evaluation for a negative pressure wound therapy device, not a diagnostic AI system with performance metrics like sensitivity, specificity, or AUC against a ground truth.

    Therefore, many of the requested elements for an AI/ML device study are not applicable or present in this document. I will answer based on the information available:


    1. Table of Acceptance Criteria and Reported Device Performance

    As this is a non-AI/ML negative pressure wound therapy device seeking substantial equivalence, "acceptance criteria" and "device performance" are framed differently than for an AI diagnostic algorithm. The document states that the device functions "as intended" and maintains "negative pressure within specifications." Specific quantitative acceptance criteria (e.g., minimum pressure maintained, maximum leakage) are not detailed in this summary, nor are corresponding "reported device performance" values in a comparative table for such criteria.

    Acceptance Criteria (Implicit from device function)Reported Device Performance (Implicit from study conclusions)
    Maintain negative pressure within specifications when used with dressings."Prevena™ Plus Negative Pressure Wound Therapy System negative pressure test demonstrates the Prevena Plus Therapy Unit when used with small and medium V.A.C. Dressing as part of a system, maintains negative pressure within specifications."
    Function as intended when used with V.A.C. Dressings."In all instances, the Prevena™ Plus 125 Therapy Unit functioned as intended with V.A.C. Dressings and all test results observed were as expected."
    Be safe and effective for its indicated uses.The submission concludes "the subject device is substantially equivalent as the predicate devices" and "does not raise different questions of safety or effectiveness."

    2. Sample size used for the test set and the data provenance

    • Sample Size: Not specified in the non-clinical tests mentioned. The "negative pressure test" and "human factors evaluation" would likely involve laboratory or simulated testing rather than patient data in the context of an established device's performance characteristics.
    • Data Provenance: Not applicable in the context of patient data for an AI/ML algorithm. These are non-clinical (laboratory/engineering) tests.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. There is no ground truth established by experts as this is not a diagnostic AI/ML device study.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not applicable. There is no ground truth established by experts.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No, an MRMC comparative effectiveness study was not done. This device is a negative pressure wound therapy unit, not an AI diagnostic tool that assists human readers.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not an AI algorithm. The device performance stands alone as a physical therapy unit.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    Not applicable. The "ground truth" for the non-clinical tests would be engineering specifications and functional requirements (e.g., pressure output, functionality as per design).

    8. The sample size for the training set

    Not applicable. There is no AI/ML model with a training set described in this document.

    9. How the ground truth for the training set was established

    Not applicable. There is no AI/ML model with a training set described in this document.


    Summary of the Study per the Document:

    The provided document describes a 510(k) submission for the Prevena Plus 125 Therapy Unit, aimed at demonstrating substantial equivalence to predicate devices. The "studies" conducted were non-clinical tests and a human factors evaluation. These tests confirmed that the device "maintains negative pressure within specifications" and "functioned as intended" when used with V.A.C. Dressings. The purpose was to show that adding the "open wound" indication, similar to a reference device, does not raise new questions of safety or effectiveness. The standard for substantial equivalence for this type of medical device does not typically require the extensive clinical validation and AI-specific study details requested in the prompt.

    Ask a Question

    Ask a specific question about this device

    K Number
    K223041

    Validate with FDA (Live)

    Date Cleared
    2022-11-22

    (54 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    RegulationNumber | 21 CFR 878.4783

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RENASYS EDGE pump is indicated for patients who would benefit from a suction pump (NPWT), as it may promote wound healing via removal of fluids, including irrigation fluids, wound exudate and infectious materials. Appropriate wound types include:

    • Chronic
    • Acute
    • · Traumatic
    • Sub-acute and dehisced wounds
    • · Ulcers (such as pressure or diabetic)
    • Partial-thickness burns
    • · Flaps
    • · Grafts

    When used with the RENASYS AB Abdominal Kit with Soft Port, the RENASYS EDGE pump is indicated for temporary bridging of abdominal wall openings where primary closure is not possible and/or repeat abdominal entries are necessary. It is intended to be used in open abdominal wounds with exposed viscera, including but not limited to abdominal compartment syndrome. The use of RENASYS AB Abdominal Kit with Soft Port is intended for use in acute hospital care settings (trauma, general and plastic surgery wards) and should ideally be applied in the operating theatre.

    Device Description

    The RENASYS EDGE device is a software controlled suction device consisting of an electric motor driven, diaphragm, vacuum pump. The device is designed to provide Negative Pressure Wound Therapy at a range of pressure settings between 25-200mmHg to a closed environment over one or two wounds. The device removes exudate from the wound site(s) to a disposable container, which may promote wound healing via removal of fluids, including irrigation of body fluids, wound exudates and infectious materials.

    RENASYS EDGE can be operated by either a mains power supply or internal battery. The RENASYS EDGE device is compatible with Smith & Nephew RENASYS Dressing Kits.

    AI/ML Overview

    The provided document is a 510(k) Premarket Notification for the RENASYS EDGE device, a negative pressure wound therapy (NPWT) system. Based on the document, here's an analysis of the acceptance criteria and the study performed:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly present a table of acceptance criteria with reported device performance in a quantitative manner as typically seen for diagnostic devices. Instead, it lists various verification activities conducted to demonstrate the overall system performance and substantial equivalence to a predicate device.

    The "acceptance criteria" here are implicitly linked to compliance with relevant medical device standards and the successful completion of specific types of testing to ensure the device performs as intended and is safe and effective when compared to the predicate device.

    Acceptance Criteria (Implicit)Reported Device Performance
    Electrical Safety (IEC 60601-1, IEC 60601-1-11)Successful completion of electrical safety testing per IEC 60601-1 (general medical electrical equipment) and IEC 60601-1-11 (for home healthcare environment).
    Electromagnetic Compatibility (EMC per IEC 60601-1-2)Successful completion of EMC testing per IEC 60601-1-2.
    Human Factors/Usability (IEC 62366, IEC 60601-1-6, FDA Guidance)Successful completion of human factors testing per IEC 62366, IEC 60601-1-6, and applicable FDA guidance "Applying Human Factors and Usability Engineering to Medical Devices."
    Bench-top Performance (including challenge conditions)Successful completion of "simulated wound model tests" and other bench-top performance testing under various challenge conditions. This likely includes: - Exudate Management: Ability to remove fluids, wound exudate, and infectious materials. - Therapeutic Pressure Setting: Ability to maintain negative pressure within the 25-200mmHg range. - Alarm Functionality: Proper functioning of alarms to notify users of therapy loss. - Auto-restart Function: Effective re-initiation of therapy after pause.
    Software VerificationSuccessful completion of software verification testing.
    Substantial EquivalenceDemonstrated through evaluation of indications for use, principle of operation, materials, technology, product specifications, and energy requirements, alongside performance testing, software verification, EMC, and electrical safety testing.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document explicitly states: "No clinical data were provided to support the demonstration of substantial equivalence."
    Therefore, there is no sample size for a test set of patients, nor is there any provenance information such as country of origin or retrospective/prospective nature, as no human clinical studies were performed. The testing conducted was entirely non-clinical.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. Since no clinical data was provided and no human test set was used, there were no experts establishing ground truth for a clinical test set. The validation was based on engineering and performance criteria against standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable, as no clinical test set requiring adjudication was used.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. The RENASYS EDGE device is a physical medical device (NPWT pump), not an AI-powered diagnostic or assistive tool for human readers. Therefore, an MRMC study is not relevant to its evaluation.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not an algorithm-only device. The evaluation focused on the physical device's performance characteristics.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for the non-clinical tests would have been the engineering specifications and established performance parameters defined by the manufacturer and relevant international medical device standards (e.g., specific negative pressure range, exudate removal rates, alarm trigger conditions, electrical safety limits, EMC limits). Compliance with these predefined technical criteria constituted the "ground truth."

    8. The sample size for the training set

    Not applicable. This is a medical device, not an AI model that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable, as there was no training set for an AI model.

    Ask a Question

    Ask a specific question about this device

    Why did this record match?
    510k Summary Text (Full-text Search) :

    Therapy System, PICO 14 Single Use Negative Pressure Wound Therapy System Regulation Number: 21 CFR 878.4783
    |
    | Regulation Number | 21 CFR 878.4783
    |
    | Product Code | QFC (21 C.F.R. § 878.4783
    | QFC (21 C.F.R. § 878.4783

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PICO Single Use Negative Pressure Wound Therapy System is indicated for patients who would benefit from a suction device (negative pressure wound therapy) as it may promote wound healing via removal of low to moderate levels of exudate and infectious materials. PICO Single Use Negative Pressure Wound Therapy Systems are suitable for use both in a hospital and homecare setting. Appropriate wound types include:

    • Chronic
    • Acute
    • Traumatic
    • Subacute and dehisced wounds
    • Partial-thickness burns
    • Ulcers (such as diabetic or pressure)
    • Flaps and grafts
    • Closed surgical incisions

    When used on closed surgical incisions, PICO Single Use Negative Pressure Wound Therapy System is intended to aid in reducing the incidence of:

    • Superficial and deep incisional surgical site infections for high risk patients in Class II wounds
    • Post-operative seroma
    • Dehiscence

    Note: When used on closed incisions for the reduction of SSI, the safety and effectiveness for Class III (contaminated) and Class IV (Dirty/Infected) wounds have not been demonstrated. Furthermore. Class IV surgical wounds are not expected to be closed primarily. The device has not been demonstrated to reduce organ space surgical site infections. The device is intended to aid in reducing the incidence of, but not treat, seroma, dehiscence, or infected wounds - the use of PICO does not preclude the need to develop and follow a comprehensive infection management protocol.

    PICO 7 Single Use Negative Pressure Wound Therapy System is indicated for patients who would benefit from a suction device (negative pressure wound therapy) as it may promote wound healing via removal of low to moderate levels of exudate and infectious materials. PICO 7 Single Use Negative Pressure Wound Therapy Systems are suitable for use both in a hospital and homecare setting. Appropriate wound types include:

    • Chronic
    • Acute
    • Traumatic
    • Subacute and dehisced wounds
    • Partial-thickness burns
    • Ulcers (such as diabetic or pressure)
    • Flaps and grafts
    • Closed surgical incisions

    When used on closed surgical incisions, PICO 7 Single Use Negative Wound Therapy System is intended to aid in reducing the incidence of:

    • Superficial and deep incisional surgical site infections for high risk patients in Class II wounds
    • Post-operative seroma
    • Dehiscence

    Note: When used on closed incisions for the reduction of SSI, the safety and effectiveness for Class III (contaminated) and Class IV (Dirty/Infected) wounds have not been demonstrated. Furthermore, Class IV surgical wounds are not expected to be closed primarily. The device has not been demonstrated to reduce organ space surgical site infections. The device is intended to aid in reducing the incidence of, but not treat, seroma, dehiscence, or infected wounds - the use of PICO does not preclude the need to develop and follow a comprehensive infection management protocol.

    PICO 7Y Single Use Negative Pressure Wound Therapy System is indicated for patients who would benefit from a suction device (negative pressure wound therapy) as it may promote wound healing via removal of low to moderate levels of exudate and infectious materials. PICO 7Y Single Use Negative Pressure Wound Therapy Systems are suitable for use both in a hospital and homecare setting. Appropriate wound types include:

    • Chronic
    • Acute
    • Traumatic
    • Subacute and dehisced wounds
    • Partial-thickness burns
    • Ulcers (such as diabetic or pressure)
    • Flaps and grafts
    • Closed surgical incisions

    When used on closed surgical incisions, PICO 7Y Single Use Negative Pressure Wound Therapy System is intended to aid in reducing the incidence of:

    • Superficial incisional surgical site infections for high risk patients in Class I wounds
    • Post-operative seroma
    • Dehiscence

    Note: When used on closed incisions for the reduction of SSI, the safety and effectiveness for Class II (Clean/ Contaminated), Class III (contaminated) and Class IV (Dirty/Infected) wounds have not been demonstrated. Furthermore, Class IV surgical wounds are not expected to be closed primarily. The device has not been demonstrated to reduce organ space surgical site infections. The device is intended to aid in reducing the incidence of, but not treat, seroma, dehiscence, or infected wounds - the use of PICO does not preclude the need to develop and follow a comprehensive infection management protocol.

    PICO 14 Single Use Negative Pressure Wound Therapy System is indicated for patients who would benefit from a suction device (negative pressure wound therapy) as it may promote wound healing via removal of low to moderate levels of exudate and infectious materials. PICO 14 Single Use Negative Pressure Wound Therapy Systems are suitable for use both in a hospital and homecare setting. Appropriate wound types include:

    • Chronic
    • Acute
    • Traumatic
    • Subacute and dehisced wounds
    • Partial-thickness burns
    • Ulcers (such as diabetic or pressure)
    • Flaps and grafts
    • Closed surgical incisions

    When used on closed surgical incisions for up to 7 days, PICO 14 Single Use Negative Pressure Wound Therapy is intended to aid in reducing the incidence of:

    • Superficial and deep incisional surgical site infections for high risk patients in Class II wounds
    • Post-operative seroma
    • Dehiscence

    Note: When used on closed incisions for the reduction of SSI, the safety and effectiveness for Class III (contaminated) and Class IV (Dirty/Infected) wounds have not been demonstrated. Furthermore, Class IV surgical wounds are not expected to be closed primarily. The device has not been demonstrated to reduce organ space surgical site infections. The device is intended to aid in reducing the incidence of, but not treat, seroma, dehiscence, or infected wounds - the use of PICO does not preclude the need to develop and follow a comprehensive infection management protocol.

    Device Description

    The PICO Family of devices, PICO (cleared under K163387), PICO 7 (cleared under K180698), PICO 7Y (cleared under K182323), PICO 14 (cleared under K191760) all have the same main function of management of fluid through dressing absorbency and evaporation with added benefit of negative pressure. The pump provides a -80mmHg nominal pressure under the dressing, applying Negative Pressure Wound Therapy (NPWT) to the wound. The PICO Single Use Negative Therapy Systems consist of:

    • PICO Pump
    • Dressing (s)
    • Fixation strips
    • Batteries
    • Connection tubing
    • Instructions for Use

    The system is a canister-less system - fluid is managed by the dressing. The pump that delivers the NPWT is a portable, battery-powered, software-controlled system that can provide continuous application of negative pressure to the wound as a delivery pressure at a nominal value of -80mmHg. The PICO Systems are designed to be used at home or within a healthcare setting by an appropriate healthcare professional.

    AI/ML Overview

    The PICO family of devices (PICO, PICO 7, PICO 7Y, and PICO 14) are Negative Pressure Wound Therapy Systems intended for use in wound treatment.

    1. A table of acceptance criteria and the reported device performance

    The provided document does not explicitly state "acceptance criteria" with numerical thresholds for performance. Instead, it demonstrates the device's effectiveness through a systematic literature review and meta-analyses, aiming to show a "statistically significant reduction" in the incidence of certain wound complications compared to standard care. The reported device performance is presented as Odds Ratios (OR) with 95% Confidence Intervals (CI). A favorable effect is suggested by an OR less than 1.

    Here's a summary of the meta-analysis results as reported:

    OutcomeDevice Performance (Odds Ratio [95% CI])Interpretation (Favorable Effect if OR < 1)
    Surgical Site Infections (SSI) - Overall0.36 [0.27; 0.49]Favorable
    Superficial SSI0.30 [0.17; 0.53]Favorable
    Deep SSI0.67 [0.46; 0.96]Favorable
    Post-operative Seroma0.37 [0.16; 0.86]Favorable
    Dehiscence0.63 [0.43; 0.92]Favorable

    2. Sample sizes used for the test set and the data provenance

    The "test set" for this submission is comprised of studies identified through a systematic literature review. This means the data is retrospective, as it relies on previously published research. The provenance of the data is global, as the literature review included studies from various researchers and institutions, not limited to a single country.

    • Overall SSI Meta-analysis:

      • Evaluable patients: 2,737 in the PICO Family therapy group, 2,936 in the SOC (control) group.
      • Total studies: 17 (12 RCTs, 5 prospective observational).
    • Superficial SSI Meta-analysis:

      • Evaluable patients: 356 in the PICO Family therapy group, 367 in the SOC (control) group.
      • Total studies: 8 (5 RCTs, 3 prospective observational).
    • Deep SSI Meta-analysis:

      • Evaluable patients: 1,146 in the PICO Family therapy group, 1,138 in the SOC (control) group.
      • Total studies: 6 (4 RCTs, 2 prospective observational).
    • Post-operative Seroma Meta-analysis:

      • Evaluable patients: 608 in the PICO Family therapy group, 618 in the SOC (control) group.
      • Total studies: 10 (7 RCTs, 3 prospective observational).
    • Dehiscence Meta-analysis:

      • Evaluable patients: 551 in the PICO Family therapy group, 656 in the SOC (control) group.
      • Total studies: 7 (6 RCTs, 1 prospective observational).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    The ground truth for the test set (the outcomes of the studies included in the meta-analysis) was established by the original researchers and clinicians who conducted each individual study. The document states:

    • "Two (2) independent reviewers performed the study selection."
    • "In case of disagreement a third reviewer made the final decision after reading the full text paper or conference abstract."
    • "Data was extracted from included studies by one reviewer using a predefined and standardized data extraction form and checked by a second reviewer for accuracy."

    The qualifications of these specific reviewers are not provided in the document. However, the outcomes themselves (SSI, seroma, dehiscence) are medical diagnoses and complications identified by the healthcare professionals directly involved in the patient care and study follow-up within the original research for each of the 25 articles. These would typically be surgeons, nurses, and other medical personnel, under the guidance of the study investigators.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    For the selection of studies for inclusion in the meta-analysis:

    • "Two (2) independent reviewers performed the study selection."
    • "If either reviewer deemed an article as potentially relevant, then the article progressed to full text screening."
    • "In case of disagreement a third reviewer made the final decision after reading the full text paper or conference abstract."
      This indicates a 2-reviewer initial screening with a third reviewer for adjudication in case of disagreement (2+1 method) for study selection.

    For data extraction:

    • "Data was extracted from included studies by one reviewer using a predefined and standardized data extraction form and checked by a second reviewer for accuracy."
      This implies a single reviewer for initial extraction with a second reviewer for verification, which is a form of 1+1 review.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC comparative effectiveness study was done, nor is this device an AI-powered diagnostic tool. The document describes a medical device (Negative Pressure Wound Therapy System) and its clinical effectiveness compared to standard care through a meta-analysis of existing clinical trials, not an AI system. Therefore, details regarding human reader improvement with/without AI assistance are not applicable.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This refers to a medical device, a wound therapy system, not an algorithm or AI system. Therefore, the concept of "standalone algorithm performance" (without human-in-the-loop) is not applicable. The device operates independently of human interpretation in its direct therapeutic action (applying negative pressure), but its application and management involve healthcare professionals.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth for the effectiveness claims of the PICO family of devices (reduction in SSI, seroma, and dehiscence) is based on outcomes data from various clinical studies. These outcomes (e.g., incidence of infection, presence of seroma, occurrence of dehiscence) were reported by the original study investigators, presumably determined through clinical assessment, and potentially supported by other diagnostic methods (e.g., microbiology for infection, imaging for seroma, clinical examination for dehiscence), depending on the specific protocols of each individual study included in the meta-analysis. For infection, the CDC guidelines for defining SSI were used, which involve clinical criteria.

    8. The sample size for the training set

    This document describes a medical device and its clinical effectiveness evaluated through a meta-analysis of clinical studies, not an AI/machine learning algorithm that requires a "training set." Therefore, the concept of a training set sample size is not applicable here.

    9. How the ground truth for the training set was established

    As explained in point 8, the concept of a "training set" is not applicable to this submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    DEN180013

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2019-04-19

    (400 days)

    Product Code
    Regulation Number
    878.4783
    Type
    Direct
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    NEW REGULATION NUMBER: 21 CFR 878.4783

    CLASSIFICATION: Class II

    PRODUCT CODE: QFC

    BACKGROUND

    Negative pressure wound therapy device for reduction of wound complications Class: II

    Regulation: 21 CFR 878.4783

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PREVENA 125 and PREVENA PLUS 125 Therapy Units manage the environment of closed surgical incisions and remove fluid away from the surgical incision via the application of -125mmHg continuous negative pressure. When used with legally marketed compatible dressings, PREVENA 125 and PREVENA PLUS 125 Therapy Units are intended to aid in reducing the incidence of seroma and, in patients at high risk for post-operative infections, aid in reducing the incidence of superficial surgical site infection in Class I and Class II wounds.

    Device Description

    The PREVENA 125 and PREVENA PLUS 125 Therapy Units ("PREVENA pumps") are singleuse, compact and portable powered suction pumps. The therapy units are packaged with compatible sterile canisters (45 ml for PREVENA 125 or 150 ml for PREVENA PLUS 125) and sterile tubing set. The therapy units can be used with compatible, legally marketed wound dressings classified under 21 CFR 878.4780, such as the PEEL & PLACE dressing and the CUSTOMIZABLE dressing, which, when combined are referred to as the PREVENA Incision Management Systems ("PREVENA systems"). The PREVENA Incision Management Systems deliver a pre-set, continuous negative pressure of 125 mmHz to the incision site. The systems are intended to be applied to incision sites immediately after surgery for a minimum of 2 days up to a maximum of 7 days depending on the surgeon's preference. The therapy units can be used up to 192 hours, after which they will automatically shut off.

    AI/ML Overview

    The provided text describes the regulatory evaluation of the PREVENA 125 and PREVENA PLUS 125 Therapy Units, focusing on clinical evidence from a systematic literature review and meta-analyses rather than a single, dedicated device performance study with specific acceptance criteria that would typically be seen for AI/ML devices. Therefore, a direct table of "acceptance criteria and reported device performance" as one might expect for a diagnostic AI/ML device is not explicitly present in the document.

    However, based on the meta-analysis results and the FDA's granted indications for use, we can infer the "acceptance criteria" were met by demonstrating a favorable trend in reducing SSI and seroma, particularly in specific subgroups. The study essentially is the meta-analysis of existing clinical data.

    Here's an interpretation of the information provided, structured to address your points, with explanations where direct parallels to AI/ML device criteria are not exact due to the nature of this submission (a device for wound therapy, not an AI/ML diagnostic).


    Inferred Acceptance Criteria and Reported Device Performance (Based on Meta-Analysis Conclusion)

    While explicit numerical acceptance criteria for a single study were not provided, the FDA's granting of the De Novo request signifies that the overall body of evidence from the meta-analysis met the regulatory standard for demonstrating safety and effectiveness for the specified indications. The "acceptance" was based on a "small but consistent trend" and "greater absolute percentage reduction" in specific high-risk populations.

    Acceptance Criterion (Inferred)Reported Device Performance (as per Meta-Analysis)
    Aid in reducing incidence of seroma for closed surgical incisions.Overall Favorable Trend: Odds Ratio (OR) of 0.31 (95% CI: 0.13, 0.75) for seroma incidence, indicating a reduction with PREVENA compared to control. (7 studies, N=366 treatment, 586 control)
    Aid in reducing incidence of superficial surgical site infection (SSI) in Class I and Class II wounds in patients at high risk for post-operative infections.Superficial SSI Reduction (Class I & II): - For Superficial Incisional SSI (all wounds analyzed for depth): OR of 0.19 (95% CI: 0.08, 0.46), showing a significant reduction. (5 studies) - For Class I wounds: OR of 0.36 (95% CI: 0.24, 0.55) for overall SSI, consistent reduction. (11 studies) - For Class II wounds: OR of 0.27 (95% CI: 0.11, 0.68) for overall SSI, consistent reduction. (3 studies) - For high-risk patients (overall SSI): OR of 0.40 (95% CI: 0.27, 0.62). Greater absolute percentage reduction observed (5.5% in treatment vs. 12.9% in control vs. 4.2% vs. 5.8% in overall). (9 studies)
    Device demonstrates acceptable safety profile.Similar Safety Profile to Conventional Dressings: No significant differences in Adverse Events (AEs) or Serious Adverse Events (SAEs) between PREVENA and control groups in the 3 studies that reported this data. Post-market data (7 years, hundreds of thousands of units shipped) consistent with anticipated AEs (skin irritation, blisters, pain, etc.), and no device-related SAEs.
    Non-clinical performance (pressure maintenance, exudate removal, alarms).Device capable of maintaining -125±25 mmHg, removing simulated wound fluid, and alarms function as intended under worst-case scenarios.
    Usability demonstrated.Usability testing showed intended users can operate the device (reviewed from prior 510(k) K141017).

    Study Details:

    1. Sample sizes used for the test set and the data provenance:

      • Test Set Sample Size:
        • For SSI meta-analysis: 20 prospective studies, total of up to 6,403 evaluable patients (1,367 in PREVENA group, 5,036 in control group).
        • For Seroma meta-analysis: 7 prospective studies, total of 952 evaluable patients (366 in PREVENA group, 586 in control group).
      • Data Provenance: The data comes from a systematic literature review and meta-analyses of published and unpublished prospective clinical studies. The geographic origin of these individual studies is not explicitly stated but implied to be global as it's a literature search. The studies are prospective. Seven articles identified as retrospective were removed to minimize bias.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Study Selection/Ground Truth Establishment:
        • Study Selection: Six (6) independent reviewers performed the initial study selection. A subset of two (2) independent reviewers assessed abstracts and manuscripts for inclusion/exclusion criteria. When discordance was identified, these two reviewers deliberated until a consensus was reached.
        • Characteristic Extraction: At least two additional independent reviewers extracted study characteristics.
        • Wound Classification (Ground Truth for Subgroup Analysis): CDC wound classification was assigned to each study by "two individuals with appropriate medical and clinical trials background."
      • Qualifications: The specific qualifications (e.g., number of years of experience, board certification) of these reviewers/experts are not detailed beyond "independent reviewers" and "individuals with appropriate medical and clinical trials background."
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • Study Selection: "When discordance was identified, the two reviewers deliberated until a consensus was reached." This suggests a consensus-based adjudication among the two reviewers, rather than a third expert "tie-breaker" (2+1).
      • Wound Classification: "a CDC wound classification was assigned by two individuals with appropriate medical and clinical trials background." It is implied a consensus or adjudication method was used if there was disagreement, but not explicitly stated.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No, an MRMC study was NOT done. This submission is for a medical device (a wound therapy unit), not an AI/ML diagnostic or assistive technology for human readers. The study is a meta-analysis of clinical trials comparing the device to conventional wound dressings. Therefore, the concept of "human readers improving with AI assistance" is not applicable here.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Not applicable. This is a physical wound therapy device, not a standalone algorithm. Its performance is evaluated in a clinical context on patients.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • The "ground truth" for effectiveness (reduction in SSI and seroma) was the clinical outcomes data reported directly by the individual prospective studies included in the meta-analysis. These outcomes were typically assessed by the clinical investigators of each respective study.
    7. The sample size for the training set:

      • Not applicable. This is a device, not an AI/ML model that requires a training set. The "training data" in a broader sense would be all the accumulated medical knowledge and device design iterations that led to the PREVENA system. The studies reviewed form the evidence base for its effectiveness, not a training set for an algorithm.
    8. How the ground truth for the training set was established:

      • Not applicable. As stated above, there is no AI/ML training set in this context.