Search Filters

Search Results

Found 383 results

510(k) Data Aggregation

    K Number
    K254283

    Validate with FDA (Live)

    Date Cleared
    2026-01-30

    (30 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    92612

    Re: K254283
    Trade/Device Name: BruxZir® Shaded 16 PLUS
    Regulation Number: 21 CFR 872.6660
    CAD/CAM block
    Classification Name: Porcelain powder for clinical use
    Regulation Number: 872.6660

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is indicated for use by dental technicians in the construction of custom made all ceramic restorations for anterior and posterior location.

    Device Description

    BruxZir Shaded 16 PLUS blanks are used for the production of full-contour zirconia and zirconia-based substructures for crowns and bridges (restorations). Multiple thicknesses and shades (A1, A2, A3, A3.5, A4, B1, B2, B3, B4, C1, C2, C3, C4, D2, D3, D4, BL1, BL3, and White) are available for milling into BruxZir restorations. The manufactured restorations are made utilizing the CAD/CAM system for design and manufacturing. The designed and manufactured restorations are then sintered and glazed. BruxZir Shaded 16 PLUS restorations are designed to match the body shade in the glazed state; however, precolor and stain should be applied if polychromatic (gingival to incisal) blending or other esthetic effects are desired. The sintered material exhibits maximum strength, color, and translucency similar to natural dentition.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253973

    Validate with FDA (Live)

    Date Cleared
    2026-01-09

    (29 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :
    • Gradual Dental Zirconia Blank - GT(F) P1, GT(F) P2, and SP Series
      Regulation Number: 21 CFR 872.6660
      Classification Name:** Powder, Porcelain
      Device Classification: II
      Regulation Number: 21 CFR 872.6660
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is indicated for fabrication of anterior and posterior dental restorations using different CAD/CAM or manual machines. All blanks are processed through dental laboratories or by dental professionals.

    Device Description

    "Gradual Dental Zirconia Blank- GT(F) P1, GT(F) P2, and SP Series" are derived from zirconia powder that has been processed through various molding and sintering techniques - into their final net shapes. These blanks are then further fabricated into various prosthetic dental devices intended for use in the production of artificial teeth in fixed or removable dentures, or for jacket crowns, facings, and veneers. The zirconia powder is composed of ZrO₂+ Y₂ O₃ + HfO₂+ Fe₂O₃+ Er₂O₃. The performance of formed zirconia dental blanks conforms to ISO 6872, Dentistry, Ceramic Materials.

    "Gradual Dental Zirconia Blank - GT(F) P1, GT(F) P2, and SP Series" are ceramic dental blanks designed for the manufacture of ceramic dental prosthetic devices. The dental prosthetic devices are fabricated by CAD/CAM machining processes. All prosthetic dental devices are intended for single use applications. At the dental lab, the blanks are held to the CAD/CAM machine which is used to machine to the final dental restoration. At the completion of the machining steps, the dental restoration is fired (i.e., sintered) in the oven to harden the ZrO₂ so that its final properties can be achieved.

    "Gradual Dental Zirconia Blank - GT(F) P1, GT(F) P2, and SP Series" are different from the predicate device as they have different manufacture process. GT(F) P1 and GT(F) P2 series use six-layer padding process to produce multi-layer aesthetic effect, while the SP series does not use padding process, produce single aesthetic effect.

    GT(F) P1 and SP series have Flexural Strength of >800 MPA, They belong to Type II, Class 5 ceramics per ISO 6872.

    GT(F) P2 series have Flexural Strength of >500 MPa, They belong to Type II, Class 4(a) ceramics per ISO 6872.

    "Gradual Dental Zirconia Blank - GT(F) P1, GT(F) P2, and SP Series" are supplied in different shapes, such as blocks, discs, rods, or customer ordered shapes. It is also supplied in the combinations of fifty different colors.

    The different colors are originated from the different constituent of color additives (such as Fe₂O₃, Er₂O₃); the different translucencies are originated from small difference in the amount of Y₂ O₃, and the multilayer aesthetic effect is originated from the different padding method used in the process of dry pressing.

    The GT(F) P1 and GT(F) P2 series are supplied in gradual changing translucencies, and multi-layer aesthetic effect. The SP series are supplied with no gradual changing translucencies, and in single-layer aesthetic effect.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252789

    Validate with FDA (Live)

    Device Name
    Glass Ceramic
    Date Cleared
    2025-12-08

    (97 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Guangdong 523800
    China

    Re: K252789
    Trade/Device Name: Glass Ceramic
    Regulation Number: 21 CFR 872.6660
    Classification Name: Porcelain powder for clinical use
    Classification Regulation: 21 CFR 872.6660
    Lithium Disilicate Glass-Ceramic | --- |
    | Product code | EIH | EIH | Same |
    | Regulation number | 21 CFR 872.6660
    | 21 CFR 872.6660 | Same |
    | Classification | Class 2 | Class 2 | Same |
    | Indications for use | Glass

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Glass Ceramic is used for the preparation of veneers, inlays, onlays, crowns, and three-unit bridges not involving molar restoration using hot press or CAD/CAM techniques.

    Device Description

    Glass Ceramic products are grouped into two main categories: CAD/CAM Glass Ceramic and Hot Press Glass Ceramic. CAD/CAM Glass Ceramic shapes include rectangular and customized shapes, and Hot Press Glass Ceramic shapes include rectangular, cylinder, and customized shapes. Glass Ceramic is available in 33 colors, and its performance conforms to ISO 6872 Dentistry: Ceramic Materials. Glass Ceramic is composed of silicon dioxide, lithium oxide, potassium oxide, phosphorus pentoxide, aluminum oxide and other oxides. This product is for prescription use only.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252446

    Validate with FDA (Live)

    Device Name
    BruxZir® NOW
    Date Cleared
    2025-09-03

    (30 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    California 92612

    Re: K252446
    Trade/Device Name: BruxZir® NOW
    Regulation Number: 21 CFR 872.6660
    CAD/CAM Block
    Classification Name: Porcelain powder for clinical use
    Regulation Number: 872.6660

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is used for dental restorations using different CAD/CAM or manual milling machines. All blocks are processed through dental laboratories or by dental professionals.

    Contraindication: BruxZir® NOW Bridge Block design is limited to a maximum of four units with a maximum of two pontics between pillars.

    Device Description

    BruxZir® NOW is a pre-shaded, fully sintered zirconia CAD/CAM block used for fabricating single-unit or multiple-unit dental restorations. BruxZir® NOW is used for fabricating single-unit dental restorations, while BruxZir® NOW Bridge Block is used for fabricating multiple-unit dental restorations. BruxZir® NOW is available in the following shades: Bleach White, Bleach 1, Bleach 3, and 16 VITA Classical shades (A1, A2, A3, A3.5, A4, B1, B2, B3, B4, C1, C2, C3, C4, D2, D3, D4). BruxZir® NOW Bridge Block is available in the following 6 VITA Classical shades: A1, A2, A3, B1, C2, D2. The method of fabricating the restoration is with CAD/CAM milling systems.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251593

    Validate with FDA (Live)

    Date Cleared
    2025-08-25

    (90 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K251593
    Trade/Device Name: DenMat Multilayered Zirconia Disc
    Regulation Number: 21 CFR 872.6660
    DenMat Multilayered Zirconia Disc
    Common Name: Powder, Porcelain
    Regulation Number: 21 CFR 872.6660

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Multilayered Zirconia Disc is indicated for fabrication of anterior and posterior dental restorations using different CAD/CAM or manual machines. All discs are processed through dental laboratories or by dental professionals.

    Device Description

    DenMat Multilayered Zirconia Discs are made of Zirconium Oxide (Y-TZP ZrO2). For dental applications in accordance with ISO 6872, (DIN EN ISO 6872), this material is specially made for manufacturing of permanent and removable dental prosthetics. After completion of the final sintering, all DenMat Multilayered Zirconia meets the requirements of ISO 6872, Type II, Class 5. It is necessary to mill the disc with an appropriate enlargement factor to account for the shrinkage that occurs during full sintering. DenMat Zirconia Multilayered (ML) discs can be used with any compatible CAD/CAM machine.

    Material Used:
    DenMat Multilayered Zirconia Discs are composed of zirconia ceramics (ZrO2) based on yttria-stabilized tetragonal zirconia (Y-TZP). The material is biocompatible according to ISO 10993-1: 2018 "Biological Evaluation of medical devices – Part 1: Evaluation and testing within a risk management process"

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for the DenMat Multilayered Zirconia Disc do not describe a study involving an AI/Machine Learning device or a Multi-Reader Multi-Case (MRMC) comparative effectiveness study comparing AI assistance to human readers.

    Instead, the document describes the physical and chemical properties of a dental material (zirconia discs) and compares them to a predicate device. The performance data presented are results from laboratory tests conducted on the material itself, not clinical studies involving human readers or AI algorithms for disease detection/diagnosis.

    Therefore, many of the requested items (e.g., sample size for test set, data provenance, number of experts for ground truth, adjudication method, MRMC study, standalone performance, training set details) are not applicable to this type of device clearance.

    However, I can extract the acceptance criteria and performance data for the material's physical properties as presented in the document.


    Acceptance Criteria and Reported Device Performance (for Material Properties)

    The acceptance criteria and reported performance relate to the physical and chemical properties of the DenMat Multilayered Zirconia Disc, as evaluated against ISO standards for dental ceramics.

    Table of Acceptance Criteria and Reported Device Performance:

    Test PerformedAcceptance CriteriaReported Device Performance (Single Crown)Reported Device Performance (Single Crown Units & 3 Unit Bridges)Applied StandardResult
    Biaxial Flexural strength≥ 100 MPa (for Single Crown)≥ 500 MPa (for Single Crown Units & 3 Unit Bridges)568.72 ± 168.22 MPa740.45 ± 252.32 MPaISO 6872: 2024Pass
    Coefficient of Thermal Expansion (CTE)10.40 ± 0.34 (x10⁻⁶ K⁻¹)10.40 ± 0.02 (x10⁻⁶ K⁻¹)10.43 ± 0.05 (x10⁻⁶ K⁻¹)ISO 6872: 2024, ASTM E831Pass
    Chemical solubility< 100 µg/cm²< 100 µg/cm²< 100 µg/cm²ISO 6872: 2024Pass
    Fracture toughness KIC> 1.0 MPa√m (for Single Crown)> 3.5 MPa√m (for Single Crown Units & 3 Unit Bridges)Minimum for Class 5: 4.0 MPa√m (overall)4.14 ± 0.43 MPa√m4.21 ± 0.48 MPa√mISO 6872: 2024 (ISO 18756/ASTM C1421)Pass
    Sintered Density≥ 6.0 g/cm³6.11 ± 0.05 g/cm³6.05 ± 0.03 g/cm³ISO 13356: 2015Pass
    RadioactivityNot more than 1.0 Bq g⁻¹ of Uranium238< 0.0174 Bq⋅g⁻¹ of ²³⁸UN/A (Tested once for material composition)ISO 6872:2024 Section 5.2Pass
    Average Flexural Strength (Overall material property)> 800 MPa1085.51 ± 265.06 MPaN/A (Tested once for material composition)ISO 6872: 2024Pass

    Non-Applicable or Unknown Information (Due to the Nature of the Device)

    The following information pertains to AI/ML device studies and is not applicable to this 510(k) for a dental material:

    1. Sample size used for the test set and the data provenance: Not applicable. These are laboratory tests on material samples, not patient data. The quantity of material samples tested is not explicitly stated in the summary, but typical for these types of tests (e.g., multiple specimens for each property). Data provenance is "lab testing."
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Ground truth for material properties is established by adherence to certified test methods and instrumentation, not expert consensus on medical images/data.
    3. Adjudication method (e.g., 2+1, 3+1, none) for the test set: Not applicable.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is not an AI/imaging device.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. This is a dental material, not an algorithm.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Ground truth for material properties is defined by the physical/chemical standards and measurements themselves as per ISO and ASTM guidelines (e.g., measured force for flexural strength, measured mass change for solubility).
    7. The sample size for the training set: Not applicable. This is not an AI device that requires a training set.
    8. How the ground truth for the training set was established: Not applicable.

    In summary, the DenMat Multilayered Zirconia Disc is a dental material, and its acceptance criteria and proving study focus on demonstrating that its physical and chemical properties meet established international standards (ISO, ASTM) for dental restorative materials, ensuring its safety and effectiveness for its intended use. It is not an AI software device, and therefore the assessment methodologies typically associated with AI/ML-based medical devices do not apply here.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250063

    Validate with FDA (Live)

    Date Cleared
    2025-07-10

    (181 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    KOREA

    Re: K250063
    Trade/Device Name: ARENA Star, Galaxy Star
    Regulation Number: 21 CFR 872.6660
    For Clinical Use

    • Primary Product Code: EIH
    • Panel: Dental
    • Regulation Number: 21 CFR 872.6660
      Porcelain Powder For Clinical Use |
      | Product Code | EIH | EIH |
      | Regulation Number | 21 CFR 872.6660
      | 21 CFR 872.6660 |
      | Indications for Use | Non-Sterile Zirconia Block (Model name: ARENA Star,
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Non-Sterile Zirconia Block (Model name: ARENA Star, Galaxy Star) are indicated for the production of artificial teeth in fixed or removable dentures, or for jacket crowns, facings, and veneers. All zirconia block are processed through dental laboratories or by dental professionals.

    Device Description

    Non-Sterile Zirconia Block (Model name: ARENA Star, Galaxy Star) used to produce dental restoration to support designing computer for dental use and to process cutting as a manufacture unit, on which CAD/CAM system is applied for processing and sintering. After application, this material cannot to be reused for fabrication.

    AI/ML Overview

    The provided FDA 510(k) clearance letter pertains to a Non-Sterile Zirconia Block used for dental restorations. This document focuses on demonstrating the substantial equivalence of the new device (ARENA Star, Galaxy Star) to a predicate device (Non-Sterile Zirconia Block, K223253) based on its material properties and chemical composition, not on an AI or software-driven diagnostic or assistive system.

    Therefore, the requested information about acceptance criteria, study design for AI performance, expert ground truth, adjudication methods, MRMC studies, or standalone algorithm performance does not apply to this submission. This is a material science and manufacturing equivalency clearance, not a performance study for AI.

    However, I can extract the acceptance criteria related to the material properties and the type of non-clinical testing performed.

    Updated Information based on the provided document:

    Acceptance Criteria and Device Performance for ARENA Star, Galaxy Star (Non-Sterile Zirconia Block)

    The acceptance criteria for this device are based on demonstrating mechanical and biological equivalence to a predicate device and adherence to international standards for dental ceramic materials.

    1. Table of Acceptance Criteria and Reported Device Performance:
    CriteriaAcceptance Standard (Predicate Device)Reported Device Performance (Subject Device)
    Density (post sintering)6.00 g/cm³6.00 g/cm³
    Flexural Strength>800 MPa per ISO 6872:2015 Type II Class 5>800 MPa per ISO 6872:2015 Type II Class 5
    Sintering temperature1500 ± 50 ℃1500 ± 50 ℃
    BiocompatibilityMeets ISO 10993 requirementsMeets ISO 10993 requirements
    Chemical CompositionZrO2 with others (Specific raw materials listed)ZrO2 with others (Specific raw materials listed)
    Non-Clinical Performance TestsConformance to specified tests including Visual, Dimensions, Packaging, Uniformity, Extraneous materials, Chemical Solubility, Linear Thermal Expansion (all per ISO 6872)Conforms to all specified tests per ISO 6872
    CytotoxicityConformance to ISO 10993-5:2009Conforms to ISO 10993-5:2009
    Intracutaneous Reactivity TestConformance to ISO 10993-10:2010Conforms to ISO 10993-10:2010
    Sensitization TestConformance to ISO 10993-10:2010Conforms to ISO 10993-10:2010
    Acute Systematic ToxicityConformance to ISO 10993-11:2017Conforms to ISO 10993-11:2017

    The remaining information requested is typically relevant for AI/ML-based medical devices, which operate on analyzing data (e.g., images, signals) and often involve performance metrics like sensitivity, specificity, accuracy, and comparisons to human expert performance. This 510(k) submission is for a physical medical device (zirconia block), where the "study" demonstrating criteria fulfillment is primarily non-clinical bench testing and chemical analysis to confirm material properties and biocompatibility.

    Therefore, for aspects like "Sample size for the test set," "Experts used to establish ground truth," "Adjudication method," "MRMC study," "Standalone performance," "Type of ground truth," "Training set sample size," and "Ground truth for the training set" – these points are not applicable to this specific device and the information provided in the 510(k) clearance letter. The "ground truth" here is established through standardized material testing methods and chemical analysis, not through expert interpretation of data.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250826

    Validate with FDA (Live)

    Device Name
    Multi M Series
    Manufacturer
    Date Cleared
    2025-06-12

    (86 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    , California 92612

    Re: K250826
    Trade/Device Name: Multi M Series
    Regulation Number: 21 CFR 872.6660

    • Porcelain Powder for Clinical Use
    • Product Code: EIH
    • Classification regulation: 21 CFR 872.6660
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Multi M Series is used in the manufacture of dental prosthesis.

    Device Description

    Multi M Series is zirconia-based ceramic provided in various shapes such as round and it is used to manufacture cores of all ceramic crowns and is classified into ISO 6872 Type 2 Class 5. It is used to manufacture ceramic restorations through cutting process by dental MAD/MAM, computer-assisted design system, or CAD/CAM system. The subject device offers 278 different shades to meet the needs of different patients' tooth colors. It also offers various shape types to be used with various jigs for CAD/CAM milling machine. Multi M Series offers various types as follows: W-type, Z-type. These different types are to accommodate the different types of the jig that is built-in CAD/CAM machine. Users can choose a type which fits the jig they have.

    AI/ML Overview

    This document is a 510(k) clearance letter for a medical device called "Multi M Series", which is a dental material. The standard 510(k) clearance process by the FDA does not typically include the kind of clinical study details usually associated with AI/ML-based diagnostic devices (e.g., sample size for test sets, expert consensus, MRMC studies, effect size of AI assistance). This device is a material, not a diagnostic algorithm.

    Therefore, many of the requested points regarding acceptance criteria and study details (like sample size for test set, number of experts, adjudication methods, MRMC studies, standalone performance) are not applicable to this type of device and submission. The "study" here refers to non-clinical performance and biocompatibility testing against international standards.

    However, I can extract the relevant information where it exists:


    The device in question, "Multi M Series," is a dental material (zirconia-based ceramic) used to manufacture dental prosthetics, not an AI-powered diagnostic device. Therefore, the "acceptance criteria" and "study" described are based on non-clinical performance and biocompatibility testing against established international standards for dental materials, rather than clinical efficacy studies with human subjects or AI algorithm performance benchmarks.

    Acceptance Criteria and Device Performance

    The acceptance criteria are derived from ISO 6872 (for ceramic materials) and ISO 10993 (for biocompatibility).

    1. Table of Acceptance Criteria and Reported Device Performance

    Criterion TypeStandard/RequirementPredicate Device (Zmaxx T Series) PerformanceSubject Device (Multi M Series) PerformanceMeets Acceptance Criteria?
    Mechanical/Physical
    CTEISO 6872(10.6 ± 0.5) × 10⁻⁶ K⁻¹(10.6 ± 0.5) × 10⁻⁶ K⁻¹Yes
    Flexural StrengthISO 6872> 600 MPa> 800 MPaYes (exceeds predicate)
    Chemical SolubilityISO 6872< 2000 µg/cm²< 100 µg/cm²Yes (exceeds predicate)
    Biocompatibility
    CytotoxicityISO 10993-5Non-toxic and biocompatibleNon-toxic and biocompatibleYes
    SensitizationISO 10993-10Non-toxic and biocompatibleNon-toxic and biocompatibleYes
    IrritationISO 10993-10Non-toxic and biocompatibleNon-toxic and biocompatibleYes
    Systemic ToxicityISO 10993-11Non-toxic and biocompatibleNon-toxic and biocompatibleYes

    Note: The reported performance for "Multi M Series" either meets or exceeds the requirements set by the ISO standards and, in some cases, the performance of the predicate device (e.g., higher flexural strength, lower chemical solubility).

    2. Sample size used for the test set and the data provenance

    The document does not specify exact sample sizes for each mechanical or chemical test. Typically, these are defined within the referenced ISO standards (e.g., ISO 6872 specifies sample numbers for flexural strength testing).
    The testing was conducted by DMAX Co., Ltd., which is based in Daegu, Korea. The data would be considered prospective, as it was generated specifically for this 510(k) submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This is not applicable as the device is a material, not a diagnostic or AI device requiring expert interpretation for ground truth. "Ground truth" for this device is based on objective, quantifiable physical, chemical, and biological measurements performed according to standardized protocols.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable for the same reasons as above. There is no expert adjudication for material property testing.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This is not applicable. This is not an AI-assisted diagnostic device, and therefore, no MRMC study or AI assistance evaluation was performed.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    This is not applicable as the device is a dental material, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for this device relies on objective measurements defined by international standards:

    • Physical/Chemical Properties: Measured values obtained through standardized laboratory tests (e.g., flexural strength, chemical solubility, CTE) as per ISO 6872 and ISO 13356. These are quantitative and inherently objective.
    • Biocompatibility: Results from established in vitro and in vivo toxicology tests (e.g., cytotoxicity, sensitization, irritation, systemic toxicity) as per ISO 10993 series, which assess the material's interaction with biological systems based on predetermined endpoints.

    8. The sample size for the training set

    This is not applicable as this is a physical material, not a software algorithm requiring a training set.

    9. How the ground truth for the training set was established

    This is not applicable as this is a physical material, not a software algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K251084

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-06-05

    (57 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Trade/Device Name: zirkon; structure; LFU shades, stains and glazes
    Regulation Number: 21 CFR 872.6660
    shades, stains and glazes
    Common Name: dental ceramic
    Product code: EIH
    FDA Regulation: 21 CFR 872.6660

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Types of restorations:

    1. Anterior and posterior crowns
    2. Veneers, inlays, onlays.
    Device Description

    zirconia layering porcelain system layering ceramic powders and pastes are used in dental laboratories by the dental technician to create ceramic restorations.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary are for "zirkon; structure; LFU shades, stains and glazes," which are dental ceramic materials (porcelain powder for clinical use), not a medical device that relies on an algorithm or AI for diagnostic or treatment assistance. Therefore, the document does not contain any information regarding acceptance criteria related to device performance in the context of AI/algorithm a medical device, nor does it describe a study to prove such performance.

    The "acceptance criteria" and "study" described in the input prompt are typically associated with AI/ML-based medical devices or diagnostic tools where performance metrics like sensitivity, specificity, or reader improvement are critical for demonstrating safety and effectiveness.

    The information provided in the FDA document focuses on the equivalence of the dental ceramic materials to a predicate device based on:

    • Intended Use: Types of dental restorations (crowns, veneers, inlays, onlays).
    • Technological Characteristics: Physical state (powder/paste), material composition (silicate glass ceramics), and classification according to ISO 6872:2019.
    • Bench Testing: Compliance with physical properties (flexural strength, chemical solubility, thermal expansion, glass transition temperature, radioactivity) and biocompatibility according to ISO 7405:2018 and ISO 10993:2018.

    Therefore, it is impossible to extract the requested information (table of acceptance criteria with device performance, sample sizes, expert details, adjudication methods, MRMC studies, standalone performance, ground truth types, or training set details) from the provided text, as these concepts are not applicable to the type of device described.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250673

    Validate with FDA (Live)

    Device Name
    CERABIEN MiLai
    Date Cleared
    2025-05-29

    (84 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    , 100-0004
    JAPAN

    Re: K250673
    Trade/Device Name: CERABIEN MiLai
    Regulation Number: 21 CFR 872.6660
    Porcelain powder for clinical use |
    | Classification Name | Powder, Porcelain |
    | Regulation Number | 872.6660

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For use in prosthetic dentistry to create an all-ceramic prosthesis.

    • Ceramic for coverage of a zirconia substructure
    • Ceramic for coverage of a lithium disilicate substructure
      [CTE: 9.5~11.0×10-6/K (50-500°C)]
    Device Description

    CERABIEN MiLai is a specific type of porcelain for dental restorations. The system consists of Powder, Paste and Liquids for powder/paste, to be applied utilizing layering technique and baked onto a ceramic frame of zirconia (ZrO2) or different lithium disilicate glasses.

    AI/ML Overview

    The provided FDA 510(k) clearance letter pertains to CERABIEN MiLai, a porcelain powder for clinical use in prosthetic dentistry. The documentation focuses on demonstrating substantial equivalence to predicate devices through compliance with established international standards for dental ceramics.

    1. A table of acceptance criteria and the reported device performance

    The acceptance criteria are derived from the requirements of the recognized consensus standards ISO 6872:2015 and ISO 9693:2019. The reported device performance indicates compliance with these standards. Specific quantitative acceptance criteria or detailed device performance values (e.g., specific flexural strength values, CTE measurements) are not explicitly itemized in the document but are stated to have been met.

    Acceptance CriteriaReported Device Performance
    ISO 6872:2015 (Dental ceramic - Strength): This standard specifies requirements for dental ceramic materials for fixed dental prostheses, including flexural strength. The specific numerical acceptance criteria within this standard are not detailed in the provided document, but compliance implies meeting these thresholds.The subject device met the requirements of ISO 6872:2015, indicating its mechanical strength properties are suitable for its intended use and comparable to predicate devices.
    ISO 9693:2019 (Dental ceramic - Compatibility): This standard specifies requirements for the compatibility of ceramic materials intended for veneering metallic and ceramic substructures for dental restorations. It includes tests for thermal compatibility (e.g., thermal shock) and bond strength. For the thermal shocking testing, the acceptance criterion implies no cracking, checking, or delamination after the specified thermal cycles.The subject device met the requirements of ISO 9693:2019 for compatibility testing for ceramic-ceramic systems. Specifically, it met the requirement of thermal shocking testing according to ISO 9693:2019, confirming its suitability with zirconia and lithium disilicate substructures within the specified CTE range (9.5~11.0×10-6/K).
    Thermal Shock Testing (Specifically for CTE range 9.5~11.0×10-6/K): The specific acceptance criterion for the thermal shocking testing with different lithium disilicate substrates is that the device "meets the requirement of thermal shocking testing according to ISO 9693:2019." This implies no failures such as cracking or delamination.The subject device met the requirement of thermal shocking testing according to ISO 9693:2019 when tested with different lithium disilicate substrates with CTEs ranging from 9.5×10-6/K to 11.0×10-6/K.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document does not explicitly state the sample sizes used for the non-clinical tests (physical and mechanical tests, thermal shocking tests). It only indicates that "Physical and mechanical tests were conducted according to ISO 6872: 2015 and ISO 9693: 2019" and "the thermal shocking testing was conducted according to ISO 9693: 2019."
    The provenance of the data (country of origin, retrospective/prospective) is not mentioned. However, since the applicant is Kuraray Noritake Dental Inc. located in Tokyo, Japan, it is reasonable to infer the testing was conducted either in Japan or under their direction.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable as the device is a material (porcelain powder) for dental prosthetics, not a diagnostic or screening device that requires expert interpretation for ground truth establishment. The performance is assessed through objective physical and mechanical tests based on recognized international standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable for a physical material testing study. Adjudication methods like 2+1 or 3+1 are used in studies involving human interpretation or diagnostic agreement, which is not the case here.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This is not applicable. MRMC studies are typically performed for AI or diagnostic imaging devices where human readers interpret medical images. The CERABIEN MiLai is a dental material, and its performance is evaluated through non-clinical physical and mechanical testing.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This is not applicable. The device is a material, not an algorithm. Its performance is inherent to its physical and chemical properties and is tested in a standalone manner against established standards without human-in-the-loop interaction in the performance evaluation.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For this type of device, the "ground truth" is established by the well-defined physical and mechanical requirements and test methods outlined in the recognized international standards ISO 6872:2015 and ISO 9693:2019. This includes objective measurements of properties like flexural strength and thermal compatibility, rather than subjective expert consensus or pathology.

    8. The sample size for the training set

    This is not applicable. The device is a physical product, not a machine learning algorithm. Therefore, there is no "training set" in the context of AI.

    9. How the ground truth for the training set was established

    This is not applicable for the reasons mentioned in point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250534

    Validate with FDA (Live)

    Date Cleared
    2025-05-20

    (85 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    200120
    CHINA

    Re: K250534
    Trade/Device Name: Biomic Color Opaque
    Regulation Number: 21 CFR 872.6660
    Classification name:** Porcelain Powder For Clinical Use
    Product code: EIH
    Regulation number: 21 CFR 872.6660
    Name:** Pre-Sintered Zirconia Coloring Liquid
    Product code: EIH
    Regulation number: 21 CFR 872.6660
    Pre-Sintered Zirconia Coloring Liquid | -- |
    | Product Code | EIH | EIH | Same |
    | Regulation No. | 21 CFR 872.6660
    | 21 CFR 872.6660 | Same |
    | Class | II | II | Same |
    | Indications for Use | Biomic Color Opaque is

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Biomic Color Opaque is liquid used for coloring pre-sintered zirconia restorations. It is used for the internal surface of dental zirconia material prosthesis.

    Device Description

    Biomic Color Opaque is a liquid primarily composed of Methylacryloyl propyl trimethoxy silane, deionized water, 1, 3-butanediol, ferric chloride, citric acid, cerium nitrate, erbium nitrate, cobaltous nitrate, manganous acetate, and aluminum nitrate.

    This product is designed for use on the internal surface of dental zirconia material prostheses. It penetrates tightly with the zirconia surface, forming an extremely thin shade layer that reduces the internal surface permeability of the zirconia material prosthesis. The devices are intended to be used solely by dental technicians for the fabrication of zirconia restorations for individual dental patients.

    For staining, the zirconia materials must be immersed into the staining solution or brushed with the liquid before sintering at high temperature. The staining solution consists of two components: Type I - a color component (A、B、C、D、W、L、M、R、S、X), and Type II - an OP component, 1:1 collocation is recommended. These components are mixed together for use on the zirconia material to achieve the desired shade.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and its accompanying summary for the "Biomic Color Opaque" device do not contain information about clinical studies or performance data related to AI/algorithm-driven performance, ground truth establishment, or multi-reader multi-case (MRMC) studies.

    The document explicitly states under Section 7.0, "Summary of Clinical Test," that "Clinical testing was not required for this submission." This indicates that the device's clearance was based on non-clinical data (bench testing, biocompatibility, sterility, shelf-life) and a comparison to a predicate device, not on AI/algorithm performance. The device itself is a "Porcelain Powder For Clinical Use" (specifically a pre-sintered zirconia coloring liquid), not an AI-driven diagnostic or image analysis tool.

    Therefore, it is impossible to provide the requested information regarding acceptance criteria, study details, sample sizes, expert involvement, and ground truth for an AI/algorithm-driven study based solely on the provided text.

    However, I can extract the acceptance criteria and performance related to the physical and chemical properties of the device, as that is the type of testing described.

    Here's a summary of the acceptance criteria and performance as described for this specific device (a coloring liquid), not for an AI algorithm:

    Acceptance Criteria and Reported Device Performance (Non-AI Device)

    Acceptance Criteria CategorySpecific Test Items (Acceptance Criteria)Reported Device Performance
    Physical and Mechanical Properties- AppearanceVerified to meet acceptable criteria
    - UniformityVerified to meet acceptable criteria
    - No Foreign MatterVerified to meet acceptable criteria
    - Flexural StrengthVerified to meet acceptable criteria
    - Chemical SolubilityVerified to meet acceptable criteria
    - Linear Expansion CoefficientVerified to meet acceptable criteria
    Biocompatibility- Cytotoxicity (ISO 10993-5)Addressed and performed according to standards (ISO 10993-1, ISO 7405)
    - Sensitization (ISO 10993-10)Addressed and performed according to standards (ISO 10993-1, ISO 7405)
    - Oral Mucosa Irritation (ISO 10993-23)Addressed and performed according to standards (ISO 10993-1, ISO 7405)
    - Acute Systemic Toxicity (ISO 10993-11)Addressed and performed according to standards (ISO 10993-1, ISO 7405)
    - Pyrogen Test (ISO 10993-11)Addressed and performed according to standards (ISO 10993-1, ISO 7405)
    - Subcutaneous Implant Test (ISO 10993-6)Addressed and performed according to standards (ISO 10993-1, ISO 7405)
    - Bacterial Reverse Mutation Test (ISO 10993-3)Addressed and performed according to standards (ISO 10993-1, ISO 7405)
    - TK Gene Mutation Test (ISO 10993-3)Addressed and performed according to standards (ISO 10993-1, ISO 7405)
    - Chemical Characterization Study (ISO 10993-18)Addressed and performed according to standards (ISO 10993-1, ISO 7405)
    Sterility and Shelf-Life- SterilityProvided non-sterile
    - Shelf-Life18 months (based on testing report)

    Regarding the AI/Algorithm-Specific Questions:

    Since the device is a dental coloring liquid and not an AI-driven device, the following information is not applicable or not provided in the document:

    • Sample size used for the test set and the data provenance: Not applicable; no AI test set described.
    • Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable; no ground truth for AI performance required.
    • Adjudication method (e.g., 2+1, 3+1, none) for the test set: Not applicable.
    • If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable.
    • If a standalone (i.e., algorithm only without human-in-the-loop performance) was done: Not applicable.
    • The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not applicable to an AI device. The ground truth for this device's performance relates to its physical/chemical conformity to standards.
    • The sample size for the training set: Not applicable; no AI training set.
    • How the ground truth for the training set was established: Not applicable.

    In conclusion, the provided FDA document details the regulatory clearance for a traditional medical device (dental coloring liquid) based on its physical, chemical, and biological properties, and its substantial equivalence to a predicate device. It does not pertain to the evaluation of an AI-powered medical device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 39