Search Filters

Search Results

Found 242 results

510(k) Data Aggregation

    K Number
    K252151

    Validate with FDA (Live)

    Device Name
    els unibond
    Manufacturer
    Date Cleared
    2025-12-05

    (149 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Point, California 92629

    Re: K252151
    Trade/Device Name: els unibond
    Regulation Number: 21 CFR 872.3200
    Dental Adhesive |
    | Classification Name & Regulation Number | Resin Tooth Bonding Agent – 21 CFR 872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Direct restorations with light-curing composite-based materials.
    • Indirect restorations: at the use of light-curing composite cements to fix inlays, onlays, crowns and bridges
    Device Description

    els unibond is an extra low shrinkage, light-curing, single component, self-etching adhesive, used to create a permanent marginal-gap-free adhesion between the tooth structure and the light-curing filling/fixing material, e.g. els extra low shrinkage® composite and els extra low shrinkage® flow.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252469

    Validate with FDA (Live)

    Date Cleared
    2025-11-06

    (92 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Name:** Magnabond SE; Magnabond UNIVERSAL; Magnabond UNIVERSAL DCA
    Regulation Number: 21 CFR 872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    MAGNABOND SE

    • Bonding agent for direct restorations of all classes of cavities using light-curing composite or compomer filling materials
    • Bonding agent for core build-ups that are made with light-curing composites

    MAGNABOND UNIVERSAL

    • Bonding agent for direct restorations of all classes of cavities using light-curing composite or compomer filling materials
    • Bonding agent for core build-ups that are made of light-curing composites
    • Bonding agent for intraoral repair of composite or compomers restorations, porcelain fused to metal (PFM), ceramic veneers and all-ceramic restorations without an additional primer
    • Sealing of cavities prior to amalgam restorations
    • Sealing of cavities and core preparations prior to the temporary luting of indirect restorations
    • Treatment of hypersensitive teeth
    • Protective varnish for glass ionomer cement restorations

    COMBINED WITH MAGNABOND UNIVERSAL DCA:

    • Bonding agent for direct restorations of all classes of cavities using self or dual curing composites and core build-ups
    • Bonding agent for indirect restorations using self or dual curing luting composites/cements
    • Luting of root posts using self or dual curing luting composites/cements
    Device Description

    Not Found

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251124

    Validate with FDA (Live)

    Device Name
    G-Bond Universal
    Manufacturer
    Date Cleared
    2025-10-02

    (174 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Illinois 60803

    Re: K251124
    Trade/Device Name: G-Bond Universal
    Regulation Number: 21 CFR 872.3200
    Tooth Bonding, Resin, Pit and fissure sealant and conditioner
    Device Classification: Class II, 872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    1. Direct bonding of restorative materials
    2. Bonding of dual-cured core build up composites
    3. Adhesive cementation of indirect restorations
    4. Priming of adherent surface of indirect restorations
    5. Intraoral repair of fractured restorations
    6. Treatment of hypersensitive teeth
    7. Sealing of tooth preparation (cavity or abutment) for indirect restorations
    8. Treatment of exposed root surfaces
    9. Micro-invasive treatment and infiltration of non-cavitated non-carious enamel lesions
    10. Post cementation
    Device Description

    G-BOND Universal is a one component, light-cured bonding agent, which can also be used for micro-invasive treatment and infiltration of non-cavitated non-carious enamel lesions, available in a 5 mL liquid bottle or 0.1 mL unit dose.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K242530

    Validate with FDA (Live)

    Date Cleared
    2024-12-20

    (116 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K242530

    Trade/Device Name: HF-Etchant Hydrofluoric Acid Etching Gel Regulation Number: 21 CFR 872.3200
    Gel Common name: Hydrofluoric Acid Etching Gel Classification name: Resin Tooth Bonding Agent (21 CFR 872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Used for extraoral etching of various types of resin bonded porcelain/ceramic restorations (veneers, crowns, and inlays) prior to the bonding and cementation procedure.

    Device Description

    HF-Etchant Hydrofluoric Acid Etching Gel is composed of water, hydrofluoric acid, thickening agent and pigment. It is a water soluble and miscible flowable gel. Using a disposable dispensing tip, the Hydrofluoric acid etching gel can be directly applied onto the porcelain/ceramic surface. Its color is red, which can be identified easily on tooth or a repairing surface with contrast. HF-Etchant Hydrofluoric Acid Etching Gel is delivered in syringes.

    AI/ML Overview

    Here's a breakdown of the requested information, based on the provided FDA 510(k) summary for the HF-Etchant Hydrofluoric Acid Etching Gel.

    Important Note: The provided document is a 510(k) summary for a medical device (HF-Etchant Hydrofluoric Acid Etching Gel), not an AI/ML-based medical device. Therefore, many of the requested fields related to AI/ML studies (like expert adjudication, MRMC studies, training/test set sample sizes, and ground truth establishment for AI) are not applicable to this type of submission and will be marked as such. The device described is a chemical etching gel, not a software algorithm.


    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Internal Standard SOP)Reported Device Performance
    ThermostabilityQualified
    Hydrofluoric acid contentQualified
    Rotational viscosity valueQualified
    pH valueQualified
    Shelf Life (2-year real-time stability)Reliable and Effective

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: Not specified for formal "test sets" as would be done for an AI/ML algorithm. The performance was determined through internal testing of the device itself.
    • Data Provenance: Not explicitly stated, but the testing was "according to Internal standard SOP of the company." This implies in-house testing by Rizhao HuGe Biomaterials Company, Ltd. (China).
    • Retrospective or Prospective: Not applicable in the context of an AI/ML algorithm. The performance testing appears to be prospective (i.e., conducted on the manufactured device).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of those Experts

    • Not Applicable. This is a chemical device, not an AI/ML system requiring expert-established ground truth for a test set. The "ground truth" for its properties (like pH, viscosity) is determined by standard chemical and physical measurement techniques.

    4. Adjudication Method for the Test Set

    • Not Applicable. See point 3.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No. This is not an AI/ML device. An MRMC study is not relevant.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) Was Done

    • Not Applicable. This is not an algorithm.

    7. The Type of Ground Truth Used

    • For physical and chemical properties (Thermostability, Hydrofluoric acid content, Rotational viscosity value, pH value): The ground truth is established by quantitative measurements against the company's internal standard operating procedures (SOPs).
    • For shelf life: The ground truth is established through real-time stability testing over a 2-year period.

    8. The Sample Size for the Training Set

    • Not Applicable. This is not an AI/ML device, so there is no "training set."

    9. How the Ground Truth for the Training Set Was Established

    • Not Applicable. See point 8.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242749

    Validate with FDA (Live)

    Date Cleared
    2024-11-08

    (57 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K242749

    Trade/Device Name: TopCEM Ceramic Primer Ceramic Coupling Agent Regulation Number: 21 CFR 872.3200
    Agent Common name: Ceramic Coupling Agent Classification name: Agent, Tooth Bonding, Resin (21 CFR 872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    TopCEM Ceramic Primer Ceramic Coupling Agent serves as priming agent and is used to create a durable adhesion between luting composites and glass/oxide ceramic, metal, composite and fiberreinforced composite restorations.

    Device Description

    TopCEM Ceramic Primer Ceramic Coupling Agent is common oral cementation repair auxiliary materials. In the process of using the product, TopCEM Ceramic Primer Ceramic Coupling Agent is placed between the prosthesis and resin adhesives, which can form the bonding layer of tooth tissue - light cure dental adhesive layer - resin cement layer - ceramic coupling agent - prosthesis, so as to achieve better bonding effect. TopCEM Ceramic Primer Ceramic Coupling Agent does not have direct contact with tooth tissue during use. TopCEM Ceramic Primer Ceramic Coupling Agent is mainly composed of silane coupling agent, acid acrylate and volatile organic solvent.

    AI/ML Overview

    The provided document is a 510(k) Premarket Notification from the FDA for a dental bonding agent. It describes the device, its intended use, and compares it to a predicate device to establish substantial equivalence.

    However, the document does not contain any information about a study that proves the device meets specific acceptance criteria based on performance metrics such as sensitivity, specificity, or accuracy, as would be expected for an AI/ML medical device. The device described is a "Ceramic Primer Ceramic Coupling Agent," which is a chemical product used in dentistry, not an AI/ML-driven diagnostic or prognostic device.

    Therefore, I cannot provide the requested information regarding:

    • A table of acceptance criteria and reported device performance (e.g., sensitivity, specificity, accuracy).
    • Sample sizes for test sets or data provenance.
    • Number of experts for ground truth establishment or their qualifications.
    • Adjudication methods.
    • MRMC comparative effectiveness studies or effect sizes.
    • Standalone algorithm performance.
    • Type of ground truth used (e.g., expert consensus, pathology, outcomes data).
    • Sample size for the training set.
    • How ground truth for the training set was established.

    The document primarily focuses on non-clinical testing of physical properties and biocompatibility for a chemical product. It states:

    • "Summary of Non-clinical testing": "The physical properties of the subject device, including Appearance, Solid Content, Bond Strength (MPa), Whether there are traces left on the glass panel surface, Packing Amount Tolerance and Detection of Infrared Characteristic Peaks, were determined and tested according to Internal standard SOP of the company, and the test results demonstrated the qualification and substantial equivalence when compared to the predicate device."
    • "Summary of Clinical testing": "Clinical test is not applicable."

    This indicates that the "acceptance criteria" and "proof" in this context relate to chemical and physical properties, and biocompatibility, as evaluated through internal SOPs and comparison to a predicate device, rather than the performance metrics typically associated with AI/ML diagnostic tools.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242675

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-11-01

    (56 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    -10 5ml, FineEtch-37 1.2ml FineEtch-37 5ml, FineEtch 37% 1.2ml 20ea pack) Regulation Number: 21 CFR 872.3200
    1.2ml 20ea pack) Common name : Dental etchant Classification name : Resin tooth bonding agent [CFR 872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    · Pretreatment etchant before resin (help to having a strong bonding strength between resin and teeth)
    · Remove smear layer of dentin and enamel
    • Pretreatment etchant before sealant (help to having a strong bonding strength between sealant and teeth)

    Device Description

    FineEtch - 10, 37 is a phosphoric acid (H3PO4) semi-gel-type agent intended for use on dentin and enamel. FineEtch will effectively remove the smear layer and help successful bonding.

    AI/ML Overview

    The provided text is a 510(k) premarket notification for a dental etchant called "FineEtch." It discusses the device's classification, indications for use, comparison to a predicate device, and performance testing. However, it does not include the information requested regarding acceptance criteria and the study proving the device meets those criteria for an AI/ML device.

    Specifically, the document states: "9. Performance Testing-Clinical tests Not Applicable". This indicates that no clinical studies, which would typically involve human subjects or human readers (as implied by questions 3-5), were conducted or submitted for this device. The non-clinical tests mention pH, viscosity, shape retention, and etching effect, comparing the device to a predicate and another dental etchant. This type of testing is characteristic of a substance or instrument, not an AI/ML diagnostic or assistive device that would rely on human expert interpretation of data.

    Therefore, I cannot provide the requested information about acceptance criteria for an AI/ML device, ground truth establishment, expert consensus, MRMC studies, or training/test set details, as this document pertains to a chemical dental product, not an AI/ML software device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K240153

    Validate with FDA (Live)

    Date Cleared
    2024-10-02

    (257 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Jersev 07436

    Re: K240153

    Trade/Device Name: Ceramic Etchant (HF-5 and HF-9) Regulation Number: 21 CFR 872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ceramic Etchant is intended for etching the porcelain veneers, crowns, and inlays extraorally. It is also used for pretreating the porcelain veneers, crowns, and inlays extraorally before bonding.

    Device Description

    Not Found

    AI/ML Overview

    I am sorry, but the provided text from the FDA 510(k) clearance letter for the Ceramic Etchant (HF-5 and HF-9) does not contain any information about acceptance criteria, device performance testing, or a study that proves the device meets specific criteria in the way described in your request.

    The document is a standard FDA clearance letter confirming substantial equivalence to a predicate device. It discusses regulatory compliance, general controls, quality system regulations, adverse event reporting, and unique device identification. It also includes the "Indications for Use" for the Ceramic Etchant.

    The information you are looking for, such as sample size, data provenance, expert qualifications, adjudication methods, MRMC studies, standalone performance, ground truth, and training set details, would typically be found in the device's 510(k) summary or a more detailed biocompatibility/performance testing report submitted as part of the 510(k) application, not in the clearance letter itself.

    Therefore, I cannot populate the table or answer the specific questions based on the provided text. The letter only states that the device is "substantially equivalent" to legally marketed predicate devices, which means the FDA has determined it is as safe and effective as a device already on the market. This determination is based on the information provided in the 510(k) submission, which is not fully detailed in this clearance letter.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241445

    Validate with FDA (Live)

    Device Name
    K-Bond Universal
    Manufacturer
    Date Cleared
    2024-07-22

    (61 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Incheon 405-821 SOUTH KOREA

    Re: K241445

    Trade/Device Name: K-Bond Universal Regulation Number: 21 CFR 872.3200
    Classification Name | Agent, Tooth Bonding, Resin | |
    | Regulation Number | 872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    -Bonding of all direct composite restorations
    -Bonding of dual/self cure composite and core build-ups
    -Repairs of composite fillings
    -Root surface desensitization

    Device Description

    K-Bond Universal is a bonding system that offers exceptional bonding strength through a convenient single bottle application. This single-component bonding agent is specifically formulated to effectively bond various types of direct composite restorations to dentin, enamel, as well as composite.

    AI/ML Overview

    The provided text describes the regulatory clearance of a dental bonding agent, K-Bond Universal, and not an AI/ML powered medical device. Therefore, information regarding acceptance criteria and studies for AI/ML devices, such as sample size for test/training sets, expert qualifications, and details about MRMC studies, is not present.

    However, I can extract information related to the performance testing described for the K-Bond Universal device:

    Here's a summary of the available information:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Performance MetricAcceptance CriteriaReported Device Performance (K-Bond Universal)
    Dentin Shear Bond Strength≥15 MPaAs good as the predicate device (exact value not specified beyond meeting criteria)
    Enamel Shear Bond Strength≥8 MPaAs good as the predicate device (exact value not specified beyond meeting criteria)
    Dentin Tubule BlockingEffective blockage confirmedEffective blockage confirmed

    2. Sample size used for the test set and the data provenance:

    • Sample Size: Not specified.
    • Data Provenance: Not specified (implied to be laboratory testing of the device and predicate).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable as this is a material performance test, not a diagnostic device requiring expert opinion for ground truth.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • Not applicable. Performance was measured against ISO standards and internal requirements.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable. This is not an AI/ML device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is not an AI/ML device.

    7. The type of ground truth used:

    • Performance criteria based on ISO 29022 standard for shear bond testing and internal requirements (for dentin and enamel shear bond strength).
    • For root surface desensitization, the ground truth was established by confirming dentin tubule blockage.

    8. The sample size for the training set:

    • Not applicable as this is not an AI/ML device.

    9. How the ground truth for the training set was established:

    • Not applicable as this is not an AI/ML device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K241056

    Validate with FDA (Live)

    Date Cleared
    2024-07-16

    (89 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Shanghai, 200122 China

    Re: K241056

    Trade/Device Name: Light Cure Adhesive Regulation Number: 21 CFR 872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Light Cure Adhesive can be used as a strict self-etch dental bonding agent, or in combination with the traditional total etch or enamel etch procedures:

    • Direct bonding under a light-cured composite or compomer fillings/resin modified glass ionomer restoratives;
    • Repair of dental restorations of ceramic, composites and/or metal alloys;
    • Indirect dental restoration applications in combination with resin cement for cementation of all sorts of dental restorations including crowns, bridges, inlays/onlays, veneers, dental posts and other restorations made from materials of metals/alloys, metal-ceramic and/or porcelain, composites, and their combinations.
    Device Description

    Not Found

    AI/ML Overview

    I am sorry, but the provided text does not contain the information required to answer your request. The document is an FDA 510(k) clearance letter for a "Light Cure Adhesive" device, which is a dental bonding agent. It discusses regulatory matters, such as substantial equivalence, general controls, and good manufacturing practices.

    It does not include details about:

    • Acceptance criteria table and reported device performance for a study proving the device meets the criteria.
    • Sample sizes or data provenance for a test set.
    • Number and qualifications of experts for ground truth establishment.
    • Adjudication methods.
    • Multi-Reader Multi-Case (MRMC) comparative effectiveness studies or their effect sizes.
    • Standalone algorithm performance.
    • Type of ground truth used.
    • Training set sample size or how its ground truth was established.

    This document is a regulatory approval, not a clinical or performance study report for an AI/software-based medical device. Therefore, I cannot extract the requested information from the given text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K233285

    Validate with FDA (Live)

    Date Cleared
    2024-05-24

    (238 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    | Cement, Dental/Agent, Tooth Bonding, Resin |
    | (21 CFR section 872.3275/872.3200

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    KATANA Zirconia ONE For IMPLANT is intended for use in partially or fully edentulous mandibles and maxillae in support of single cement-retained restorations.

    For the SBL 3.3 L titanium bases, the indication is restricted to the replacement of single lateral incisors in the maxilla and lateral and central incisors in the mandible.

    KATANA Zirconia ONE For IMPLANT is used in combination with the TiBase and Sirona Dental CAD/CAM System. KATANA Zirconia ONE For IMPLANT cemented to the TiBase is recommended for two-piece hybrid abutments for single tooth restorations and hybrid abutment crowns, used in conjunction with endosseous dental implants.

    Compatible implant systems and TiBase are as follows.

    Device Description

    The KATANA Zirconia ONE For IMPLANT mesostructure material (conforming to ISO 6872:2015) is a pre-sintered zirconia block to be used as the ceramic mesostructure component of a two-piece titanium base abutment. KATANA Zirconia ONE For IMPLANT is compatible with the specified TiBase and the CAD/CAM component of the Sirona Dental CAD/CAM system (K193408, K200191) as identified in the Indications for Use. This device is further processed by the trained professional to make individually designed mesostructure that are milled into the desired shape of a hybrid abutment or hybrid abutment crown.

    The Zirconia block has identical composition as our own previously cleared reference device, KATANA Zirconia Block (K190436) under product code "EIH".

    The mesostructure material of KATANA Zirconia ONE For IMPLANT is available in shades, A1, A2, A3, A3.5, B1, B2, C1, C2, D2 and NW for flexibility and application variety to meet individual patient needs. The mesostructure material of KATANA Zirconia ONE For IMPLANT is available with one block size and two sizes of access hole, which is small (S) and large (L).

    The abutment must be sterilized after the cementation of the CAD/CAM patient matched mesostructure on the pre-manufactured titanium base component. PANAVIA SA Cement Universal (K183537) is used as the cement to set the mesostructure material to TiBase when the mesostructure material of the subject device set to TiBase prior to sterilization.

    Dentsply Sirona has issued a letter of authorization indicating that the subject mesostructure material of the subject device can be selected in combination with the CAD/CAM system. Kuraray Noritake Dental and Dentsply Sirona have a business agreement for adding this new material to the Sirona CAD/CAM system. Kuraray Noritake Dental has worked with Dentsply Sirona to implement their new material into the Sirona CAD/CAM system libraries.

    KATANA Zirconia ONE For IMPLANT which is the subject of this premarket notification consists of:

    • Sirona Dental CAD/CAM System with CEREC Chairside Software or with inLab Software
    • Sirona TiBase
    • . KATANA Zirconia ONE mesostructured blocks
    AI/ML Overview

    The provided text is a 510(k) summary for a dental device, specifically a zirconia block for implant mesostructures. It details the device's indications for use, design, material composition, and technical characteristics, comparing it to predicate and reference devices.

    Here's the breakdown of the acceptance criteria and study information:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria / Performance AspectDevice Performance / Standards Met
    Material CompositionIdentical to reference device KATANA Zirconia Block (K190436)
    BiocompatibilityEvaluated per ISO 10993 series and ISO 7405; meets requirements
    Material Standards (Zirconia Ceramic)Conforms to ISO 6872:2015
    Dynamic Fatigue Test (Implants)Performed according to ISO 14801:2016 for worst-case representative devices
    SterilizationValidated per ISO 17665-1, achieving SAL of at least 10^-6
    MR Environment CompatibilityNon-clinical worst-case MRI review performed based on scientific rationale and published literature; addressed magnetic displacement force and torque.
    CAD/CAM System CompatibilityConfirmed compatible with Sirona Dental CAD/CAM System (K193408, K200191) through a business agreement and disclosed requirements.
    Abutment Post Height4.0 mm ~ 16.7 mm
    Angulation0° ~ 20° (over 20° is contraindication at TiBase)
    Wall Thickness0.8 mm ~ 9.5 mm
    Diameter3.3 mm ~ 6.0 mm (dependent on selected TiBase)
    Gingival Height1.0 mm (dependent on selected TiBase)

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state a specific "test set" sample size for a clinical study. The performance evaluation relied on non-clinical testing and comparison to predicate devices, referencing international standards and scientific literature.

    • Data Provenance: The document does not specify a country of origin for any data beyond the manufacturer being in Japan. The studies are non-clinical, involving material testing and compatibility assessments. There is no mention of retrospective or prospective data as no human clinical testing was performed.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Not applicable. No human clinical testing was performed, and thus no expert ground truth was established for a clinical test set. The ground truth for material properties and performance would be derived from adherence to international standards and non-clinical testing protocols.

    4. Adjudication Method for the Test Set

    Not applicable. As no clinical test set requiring human interpretation or adjudication was used, this information is not relevant.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. The document explicitly states: "No human clinical testing was performed to support the substantial equivalence of the subject device."

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    This device is not an AI algorithm. It is a physical dental material (zirconia block) used in a CAD/CAM system. Therefore, the concept of "standalone (algorithm only)" performance is not applicable. The performance is related to the material's physical and mechanical properties, its compatibility with the CAD/CAM system, and its ability to meet structural requirements when fabricated into an abutment.

    7. The Type of Ground Truth Used

    The ground truth for this device is based on:

    • International Standards: Adherence to established ISO standards for ceramic dental materials (ISO 6872:2015) and dynamic fatigue testing for dental implants (ISO 14801:2016).
    • Material Composition: Verification of identical chemical composition to a previously cleared reference device (KATANA Zirconia Block, K190436).
    • Biocompatibility Standards: Evaluation against ISO 10993 series and ISO 7405.
    • Engineering Design Parameters: Validation against specified design parameters for abutment post height, angulation, wall thickness, diameter, and gingival height, consistent with CAD/CAM system requirements and FDA recommendations.
    • Compatibility: Confirmation of functional compatibility with the predicate CAD/CAM system (Dentsply Sirona) and associated TiBase components through a business agreement and technical specifications.

    8. The Sample Size for the Training Set

    Not applicable. This device is a physical material, not an AI/ML algorithm that requires a "training set."

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 25