510(k) Data Aggregation

    K Number
    K251572

    Validate with FDA (Live)

    Date Cleared
    2025-12-19

    (211 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    4 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K251572
    Trade/Device Name: eRapid with eTrack System
    Regulation Number: 21 CFR 868.5630
    510(k) Number: K223840
    Classification Name: Nebulizer Direct Patient Interface (21 CFR 868.5630
    Proprietary Name:* eRapid NCP Nebulizer System
    510(k) Number: K223840
    Regulation No.: 868.5630
    /Device Name:** AireHealthTM Nebulizer
    510(k) Number: K201167
    Regulation Number: 21 CFR 868.5630
    | Nebulizer (direct patient interface) 21 CFR 868.5630 | Identical |
    | 510k No. | K223840 | K251572

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The eRapid Nebulizer System is to be used with patients for whom doctors have prescribed medicine for nebulization. It is intended for adult and pediatric patients age 4 and older who can coordinate breathing through a mouthpiece, and may be used in hospitals, hospital-type facilities, nursing homes, sub-acute institutions and home environments.

    Device Description

    The eRapid with eTrack controller is a single-patient use, reusable electronic nebulizers, using micro-perforated vibrating membrane technology to aerosolize liquid medications. It is for adult and pediatric inhalation therapy in a home care, nursing home, sub-acute institution, or hospital environment. The devices are hand-held and portable, consisting of a controller and a nebulizer handset, connected with a connection cord. Power input is provided by either AA batteries, or a DC or AC adapter. Alternate power cords, plugs and adapters allow their use in any country.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251659

    Validate with FDA (Live)

    Date Cleared
    2025-11-14

    (168 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    China

    Re: K251659
    Trade/Device Name: Mesh Nebulizer (H6)
    Regulation Number: 21 CFR 868.5630
    Nebulizer
    5) Review Panel: Anesthesiology
    6) Product Code: CAF
    7) Regulation Number: 21 CFR 868.5630

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Mesh Nebulizer designed to aerosolized liquid medications for inhalation by patient, the device may be used with pediatric (> 4 years of age) and adult patients in the home, hospital and sub-acute care settings.

    It is not intended for use with Pentamidine.

    Device Description

    The Mesh Nebulizer H6 is a portable handheld device that uses micromesh vibration technology to generate aerosols for inhalation by patients. The H6 consists of a main unit, a nebulizer cup and optional accessories, including inhalation masks (available in child and adult sizes), a mouthpiece and a power cord. The main unit housing is made of ABS material, the nebulizer cup is made of PC material, the inhalation mask is made of PP&TPE&silicone material, and the mouthpiece is made of PP&silicone material. It can be powered by an internal lithium battery or by an adapter that complies with the IEC 60601-1 standard.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K244035

    Validate with FDA (Live)

    Date Cleared
    2025-09-19

    (263 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    China

    Re: K244035
    Trade/Device Name: Portable mesh nebulizer (JM821)
    Regulation Number: 21 CFR 868.5630
    Review Panel:** Anesthesiology
    Product Code: CAF
    Device Class: II
    Regulation Number: 868.5630
    (Direct patient interface)
    Product Code: CAF
    Device Class: II
    Regulation Number: 868.5630
    -------------------|--------------------------------------|----------|
    | Regulation number | 21 CFR 868.5630
    | 21 CFR 868.5630 | Substantial equivalence |
    | Regulatory class | Class II | Class II | Substantial

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The portable mesh nebulizer is intended to aerosolize medicine liquid for inhalation by the patient. The device is used with adult and pediatric (≥3 years old) both in hospital, home, and sub-acute settings.

    It is not intended for use with Pentamidine.

    Device Description

    JM821 portable mesh nebulizer is a portable vibrating mesh nebulizer, which incorporates a piezoelectric transducer that vibrates at a nominal frequency when electrical current is applied. It is designed to nebulize liquid medications into fine particulates for inhalation by a patient, so as to therapy respiratory diseases.

    The subject device is portable size, handheld design, it is powered by a 3.7V d.c. internally lithium battery, which is charged by an adapter.

    The subject device does not contain any medicine. Only use physician-prescribed solutions that are approved for use with a general-purpose nebulizer. Consult drug manufacturer's instructions regarding suitability for nebulization.

    The portable mesh nebulizer is single-patient, multiple-use. The mask can be can used for 30 sessions of aerosol treatment.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251615

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-09-02

    (98 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K251615
    Trade/Device Name: Aerogen Pro-X1 Controller System
    Regulation Number: 21 CFR 868.5630
    Re: K251615
    Trade/Device Name: Aerogen Pro-X1 Controller System
    Regulation Number: 21 CFR 868.5630

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Aerogen® Pro-X1 controller System is a portable medical device system inclusive of the Aerogen Solo Nebulizer (Single-patient, Multiple use) which is intended to aerosolize prescribed medications for inhalation to paediatric (29 days and older) and adult patients during invasive ventilation, non-invasive respiratory support or to conscious and spontaneous breathing patients in the hospital environment.

    Device Description

    The Aerogen® Pro-X1 controller System is a portable medical device system inclusive of the Aerogen Solo Nebulizer (Single-patient, Multiple use) which is intended to aerosolize prescribed medications for inhalation to paediatric (29 days and older) and adult patients during invasive ventilation, non-invasive respiratory support or to conscious and spontaneous breathing patients in the hospital environment.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K243244

    Validate with FDA (Live)

    Date Cleared
    2025-07-25

    (287 days)

    Product Code
    Regulation Number
    868.5270
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    1102, NB-1103 |
    | Common Name | Nebulizer |
    | Regulatory Class | Class II |
    | Classification | 21CFR §868.5630

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Heated Breathing Tube is intended to be used for non-invasive respiratory therapy, such as CPAP/BiPAP therapy. It provides air connection between positive pressure ventilation, respiratory humidification therapy instrument, and ventilation mask, nasal cannula, trachea cannula etc. With the function of heating inside breathing tube, it can prevent condensation of the therapy air in the tube.

    This device is single patient use only for adults.

    Device Description

    The Compressor Nebulizer is mainly composed of the compressor and nebulizer kit(Optional). The compressor is mainly composed of shell, compressed motor, pump, fuse wire, air filter, power cord and plug (NB-1100,NB-1101,NB-1102,NB-1103 applicable), PCB (only model NB-1102,NB-1103applicable). The device is equipped with a nebulizer kit including Nebulizer Cup, Air Tube, Mouthpiece(Optional), Adult Mask(Optional), Child Mask(Optional) to easily delivery the medical aerosol. The Nebulizer kit is available in three models/configurations as below.

    • NK-101: Nebulizer Cup, Air Tube, Adult Mask and/or Child Mask, Mouthpiece;
    • NK-301: Nebulizer Cup, Air Tube, Adult Mask and/or Child Mask;
    • NK-501: Nebulizer Cup, Air Tube, Mouthpiece
      This device operates on the Venturi principle. According to the principle of Venturi, the compressed air of the motor is used to form a high-speed air flow through the small pipe mouth. The negative pressure generated drives the liquid or other fluid to spray together on the barrier, and under the high-speed impact makes the droplets turn into mist particles to spray from the outlet trachea.
    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary pertain to a "Compressor Nebulizer" and a "Heated Breathing Tube," but the main body of the 510(k) summary and the comparative particle test tables focus on the "Compressor Nebulizer" (Model NB-1100, NB-1101, NB-1102, NB-1103) and its predicate "NE-C801 Nebulizer Compressor System." The "Heated Breathing Tube" mentioned in the clearance letter is inconsistent with the detailed submission summary. Therefore, the analysis will focus on the Compressor Nebulizer (JOYTECH NB-1103).

    Based on the provided document, the acceptance criteria are implicitly derived from the comparative particle test results between the subject device (JOYTECH NB-1103) and the predicate device (OMRON NE-C801). The study aims to demonstrate substantial equivalence by showing that the differences in technological characteristics do not raise different questions of safety or effectiveness. The core of this demonstration lies in the comparative aerosol performance data.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state numerical acceptance criteria in a "pass/fail" format. Instead, it presents a comparison table and concludes that the devices are "Equivalent" or "Similar" for various parameters. For the aerosol performance metrics, the implication is that the subject device's performance should be comparable to, or within an acceptable range of, the predicate device's performance across different drug types and patient interfaces.

    Given the structure, the reported device performance is the reported data in the comparative particle test tables. The "acceptance criteria" are implicitly that the subject device's performance metrics (MMAD, GSD, Respirable Dose, Respirable fraction, Total delivered Dose, Total delivered Dose fraction, Coarse Particle Fraction, Fine Particle Fraction, Ultra-Fine Particle Fraction) are comparable to (i.e., not significantly worse than) the predicate device.

    Key Performance Metrics for Aerosol Performance (Based on Comparative Particle Test)

    Acceptance Criteria CategorySpecific MetricPredicate Device (OMRON NE-C801) Performance (Adult Mask, Albuterol Sulfate)Subject Device (JOYTECH NB-1103) Performance (Adult Mask, Albuterol Sulfate)Comparison Result/Implicit Acceptance
    Aerosol Particle Size DistributionMMAD (μm)4.173±0.1263.466±0.173Subject device has smaller MMAD, potentially better penetration. Considered "Equivalent."
    GSD1.845±0.0461.988±0.033Slightly higher GSD for subject device, indicating a wider particle size distribution. Considered "Equivalent."
    Coarse Particle Fraction (%) (>4.7μm)45.607±2.48635.924±2.212Subject device has lower coarse particle fraction. Considered "Equivalent."
    Fine Particle Fraction (%) (<4.7μm)54.393±2.48664.076±2.212Subject device has higher fine particle fraction. Considered "Equivalent."
    Ultra-Fine Particle Fraction (%) (<1.0μm)3.207±0.3515.891±0.795Subject device has higher ultra-fine particle fraction. Considered "Equivalent."
    Drug Delivery EfficiencyRespirable Dose (μg)1239.14±150.6741628.633±99.49Subject device delivers more respirable dose. Considered "Equivalent."
    Respirable fraction58.136±2.58367.273±2.066Subject device has higher respirable fraction. Considered "Equivalent."
    Total delivered Dose (μg)2131.073±210.7112418.382±90.219Subject device delivers more total dose. Considered "Equivalent."
    Total delivered Dose fraction (%)40.801±4.14346.227±1.75Subject device has higher total delivered dose fraction. Considered "Equivalent."

    Note: The table above uses Albuterol Sulfate with an adult mask as an example condition. Similar comparisons are presented in the document for other drugs (Ipratropium Bromide, Budesonide), patient interfaces (mouthpiece), and pediatric conditions. The consistent conclusion (Explicitly stated in the document: "Equivalent") across these detailed comparisons serves as the overall acceptance criteria for aerosol performance.

    2. Sample Size Used for the Test Set and Data Provenance

    The document states, "Table: Comparative particle test comparison" and provides mean values with standard deviations (e.g., 3.466±0.173). This indicates that each reported value is the result of multiple measurements. However, the exact sample size (e.g., number of runs, 'n' for each mean and standard deviation calculation) for the particle characterization testing is not explicitly stated in the provided text.

    The data provenance is not mentioned. It is a non-clinical test conducted for regulatory submission rather than a clinical study with patient data origins.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    This type of testing (particle size characterization) is generally conducted in a laboratory setting using specialized equipment (e.g., cascade impactors) and established protocols (e.g., USP <1601> or <1602>). It does not involve human experts establishing a "ground truth" in the way a diagnostic imaging study would. The data generated is objective, quantitative measurements of aerosol properties by an instrument. Therefore, this question is not applicable to the type of non-clinical study described.

    4. Adjudication Method for the Test Set

    Since the ground truth is established through objective laboratory measurements rather than human interpretation, an adjudication method (like 2+1 or 3+1 for expert review) is not applicable.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done

    No, an MRMC comparative effectiveness study was not done. The study described is a non-clinical laboratory comparison of aerosol performance between the subject device and a predicate device. It assesses the physical characteristics of the aerosol produced, not human reader performance with or without AI assistance. This question is not applicable to this type of device and study.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    This question typically applies to AI/software as a medical device (SaMD). The device in question is a Compressor Nebulizer, a physical medical device. Therefore, a standalone algorithm-only performance assessment is not applicable. The performance tested is the physical device's ability to generate aerosols.

    7. The Type of Ground Truth Used

    The ground truth for the device's performance (specifically aerosol characteristics) is established by objective, quantitative laboratory measurements of particle size, distribution, and drug delivery efficiency, as obtained using standard analytical methods (e.g., based on FDA guidance and potentially pharmacopeial standards for aerosol drug delivery systems). This is presented as "Particle Size characterization testing" on Page 13.

    8. The Sample Size for the Training Set

    The document describes non-clinical testing for a physical device, comparing its performance to a predicate device. There is no mention of a training set as this is not a machine learning or AI-based device. This question is not applicable.

    9. How the Ground Truth for the Training Set was Established

    As there is no training set for this device, this question is not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243468

    Validate with FDA (Live)

    Date Cleared
    2025-07-02

    (236 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    1101); Compressor Nebulizer (NB-1102); Compressor Nebulizer (NB-1103)
    Regulation Number: 21 CFR 868.5630
    1102, NB-1103 |
    | Common Name | Nebulizer |
    | Regulatory Class | Class II |
    | Classification | 21CFR §868.5630

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Compressor Nebulizer system is intended to provide air to the pneumatic nebulizer in order to aerosolize medications for inhalation by the patient for respiratory disorders. The nebulizer is driven by the integral air compressor.

    The system is designed for use with pediatric (ages 2 years and above) and adult patients in the home, hospital, and sub-acute settings.

    Device Description

    The compressor Nebulizer is mainly composed of the compressor and nebulizer kit(Optional). The compressor is mainly composed of shell, compressed motor, pump, fuse wire, air filter, power cord and plug (NB-1100,NB-1101,NB-1102,NB-1103 applicable), PCB (only model NB-1102,NB-1103applicable). The device is equipped with a nebulizer kit including Nebulizer Cup, Air Tube, Mouthpiece(Optional), Adult Mask(Optional), Child Mask(Optional) to easily delivery the medical aerosol. The Nebulizer kit is available in three models/configurations as below.

    • NK-101: Nebulizer Cup, Air Tube, Adult Mask and/or Child Mask, Mouthpiece;
    • NK-301: Nebulizer Cup, Air Tube, Adult Mask and/or Child Mask;
    • NK-501: Nebulizer Cup, Air Tube, Mouthpiece
      This device operates on the Venturi principle. According to the principle of Venturi, the compressed air of the motor is used to form a high-speed air flow through the small pipe mouth. The negative pressure generated drives the liquid or other fluid to spray together on the barrier, and under the high-speed impact makes the droplets turn into mist particles to spray from the outlet trachea.
    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for JOYTECH Healthcare Co., Ltd.'s Compressor Nebulizer (K243468) primarily details the substantial equivalence of the new device to a predicate device, focusing on non-clinical performance testing, specifically particle size characterization.

    It's important to note that this document does not describe a study involving human subjects or artificial intelligence (AI). The "acceptance criteria" and "study that proves the device meets the acceptance criteria" in this context refer to the engineering and performance specifications for a nebulizer, evaluated through laboratory testing against a predicate device and relevant standards. Therefore, many of the requested points related to AI/MRMC studies, expert ground truth, adjudication methods, and training sets for algorithms are not applicable to this specific device clearance.

    Below is an interpretation of the provided information within the framework of your request, focusing on the relevant parts and explicitly stating where information is not available or not applicable.


    Acceptance Criteria and Device Performance for JOYTECH Compressor Nebulizer (K243468)

    The acceptance criteria for this device are established by demonstrating substantial equivalence to a legally marketed predicate device (Omron Compressor Nebulizer Systems NE-C801, K110860) and by meeting relevant performance standards, particularly regarding aerosol particle characterization. The 'study' proving this is primarily the "Particle Size characterization testing" detailed in the submission.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implicitly defined by performing "comparative particle test comparison" against the predicate device. The goal is to show that the proposed device performs similarly or equivalently to the predicate across key aerosolization parameters. The performance data provided is the direct result of this testing.

    Table: Comparative Particle Test Comparison (Summary of Select Parameters)

    Test ItemEndpoint (Acceptance Criteria Implicitly Compared to Predicate)Subject Device (JOYTECH NB-1103) Performance (Range across drugs/interfaces)Predicate Device (OMRON NEC801) Performance (Range across drugs/interfaces)Comparison Result (as per Submitter)
    MMAD ($\mu$m)Particle size distribution suitable for inhalation therapy, comparable to predicate.3.413 - 5.7573.7 - 6.248Equivalent / Similar
    GSDParticle size distribution uniformity, comparable to predicate.1.764 - 2.3811.605 - 2.141Equivalent / Similar
    Respirable Dose ($\mu$g)Amount of drug delivered in respirable range, comparable to predicate.51.307 - 1628.63350.723 - 1239.14Equivalent / Similar
    Respirable Fraction (%)Proportion of aerosolized drug in respirable range, comparable to predicate.39.103 - 67.95831.781 - 63.741Equivalent / Similar
    Total Delivered Dose ($\mu$g)Total amount of drug delivered, comparable to predicate.112.976 - 2562.202146.303 - 2131.073Equivalent / Similar
    Total Delivered Dose Fraction (%)Proportion of initial drug dose delivered, comparable to predicate.21.305 - 49.06327.55 - 40.801Equivalent / Similar
    Fine Particle Fraction (%) (<4.7$\mu$m)Percentage of particles less than 4.7 $\mu$m, comparable to predicate.35.454 - 64.7727.946 - 60.533Equivalent / Similar
    Coarse Particle Fraction (%) (>4.7$\mu$m)Percentage of particles greater than 4.7 $\mu$m, comparable to predicate.35.232 - 64.54739.467 - 72.054Equivalent / Similar
    Ultra-Fine Particle Fraction (%) (<1.0$\mu$m)Percentage of particles less than 1.0 $\mu$m, comparable to predicate.Ranges provided are minimal/absent for Budesonide, otherwise 4.006-5.891Ranges provided are minimal/absent for Budesonide, otherwise 2.456-4.26Equivalent / Similar

    Note: The ranges represent the lowest and highest values across the tested drugs (Albuterol Sulfate, Ipratropium Bromide, Budesonide) and patient interfaces (adult mask, child mask, mouthpiece) for both adult and pediatric conditions. The "Comparison Result" is the submitter's statement from the document.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: The tables show mean and standard deviation values for each parameter, implying multiple measurements were taken for each drug and interface combination. However, the exact number of replicates (sample size for each data point in the tables) is not explicitly stated in the provided text. It is typically standard practice in such testing to perform a minimum of triplicate measurements.
    • Data Provenance: The data is generated from laboratory performance testing of the device and its predicate. This is a non-clinical study.
      • Country of Origin: The manufacturer, JOYTECH Healthcare Co., Ltd., is located in Hangzhou City, Zhejiang, China. The predicate manufacturer, Omron Healthcare, Incorporated, is typically based in Japan with a strong presence in the US. The testing itself would have been conducted in a certified lab, likely in China or an associated region.
      • Retrospective or Prospective: This is prospective laboratory testing conducted specifically for this 510(k) submission.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    Not applicable. This study does not involve expert interpretation of medical images or patient data to establish a ground truth. Instead, it involves physical and chemical measurements (particle size and drug delivery) performed on the nebulizer using standardized laboratory methods outlined in FDA guidance and relevant ISO standards (e.g., ISO 18562 series). The "ground truth" is derived from these objective measurements and comparison to the predicate's performance.

    4. Adjudication Method for the Test Set

    Not applicable. As this is laboratory performance testing, there's no "adjudication" in the sense of reconciling human expert opinions. The results are quantitative measurements.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    No, an MRMC comparative effectiveness study was not done. This device is a medical device for drug delivery, not an AI diagnostic or assistive tool for human readers. Therefore, there is no human-in-the-loop performance to improve with AI assistance.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) was Done

    Not applicable. This device is hardware (a compressor nebulizer), not a software algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" for this device's performance testing is objective physical and chemical measurement data obtained through standardized laboratory protocols (e.g., cascade impaction for particle sizing, chemical analysis for drug quantity) rather than expert consensus, pathology, or outcomes data. The acceptability is determined by evaluating if these measurements are comparable to the well-established performance of a predicate device already on the market and align with general principles for effective nebulizer function.

    8. The Sample Size for the Training Set

    Not applicable. This is not an AI/machine learning device, so there is no "training set."

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. There is no "training set" or "ground truth" in the context of an AI model for this device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250022

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-06-30

    (178 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Texas 78746

    Re: K250022
    Trade/Device Name: HeroTracker Sense
    Regulation Number: 21 CFR 868.5630
    Name:** HeroTracker® Sense
    Common/Usual Name: Nebulizer Accessory
    Regulation Number(s): 868.5630
    ---------------------------|------------|
    | Product Code | CAF | CAF | Same |
    | Regulation Number | 868.5630
    | 868.5630 | Same |
    | Intended for Use | Nebulizer accessory for recording nebulizer use and technique

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The HeroTracker Sense Device (HTS) is an add-on device which is attached by patients on a metered-dose inhaler (MDI).

    HTS is intended for single-patient multiple use in the home environment as an electronic data capture accessory for monitoring and recording actuation, inhaler shake, inhaler orientation, inhalation coordination, and inspiratory strength and duration for prescribed inhaler usage.

    HTS may be used in the following applications: in clinical practice or clinical trials, where specialists, general practitioners, nurses and educators need to know if a patient has used their prescribed medication or assess inhaler technique.

    HTS is designed to work only with the MDI and medication indicated on the HTS label.

    HTS is not intended to indicate the remaining quantity of medication in an inhaler and does not include a dose counting function.

    HTS is not intended to provide spirometry measurements.

    HTS is intended to be used by Metered Dose Inhaler (MDI) users aged 12 years and over.

    Device Description

    The HeroTracker Sense (HTS) is a nebulizer accessory. It is an add-on device which is attached by patients on a metered dose inhaler (MDI) and is used to record and analyze data related to medication actuation and technique of use for prescribed inhaler usage. Data is transferred to a mobile application with appropriate settings and is displayed to end users.

    AI/ML Overview

    The provided FDA 510(k) Clearance Letter for HeroTracker Sense (HTS) does not contain the detailed information necessary to answer all parts of your request regarding acceptance criteria and a study proving the device meets those criteria. The document primarily focuses on demonstrating substantial equivalence to a predicate device based on non-clinical performance data.

    Here's a breakdown of what can be gleaned from the document and what information is missing:

    Missing Information: The document explicitly states "No clinical data was necessary to determine the substantial equivalence of this device." This means there was likely no "performance study" in the traditional sense, with a clinical test set, ground truth experts, adjudication, or MRMC studies. The acceptance criteria for performance would have been established and demonstrated through non-clinical testing.

    Therefore, many of the sections you requested (e.g., sample size for test set, number of experts, adjudication, MRMC, specific effect sizes, ground truth type for test set the training set) cannot be answered from the provided text.

    Inference from Document's Purpose: The 510(k) process for this device relies heavily on demonstrating that the HeroTracker Sense (HTS) functions similarly to its predicate device (Hailie® Sensor NF0110) and that any differences do not raise new questions of safety or effectiveness. The performance validation would have been against defined specifications for each function, likely derived from the predicate device's capabilities and internal design requirements.


    Acceptance Criteria and Device Performance (Based on available non-clinical data)

    Since clinical data was not required, the "acceptance criteria" for the device would be met by passing the non-clinical performance and safety tests. The "reported device performance" is essentially that it "passed" these tests and met its internal specifications.

    Table of Acceptance Criteria and Reported Device Performance (Inferred from Non-Clinical Testing):

    Acceptance Criteria CategorySpecific Criteria (Inferred from testing)Reported Device Performance
    BiocompatibilityMaterials are biocompatible (ISO 10993-1)Passed - "Materials can be considered as biocompatible."
    Electrical SafetyCompliance with IEC 60601-1, IEC 60601-1-11, IEC 60601-1-6Passed
    Electromagnetic Disturbance (EMD)Compliance with IEC 60601-1-2Passed
    Software FunctionalityCorrect functionality of HTS software, modules, and mobile app association (IEC 62304/FDA Guidance)Passed - "verified"
    Breathing Gas Pathway Biological SafetyRisk-based evaluation adequacy (ISO 18562-1)Passed - "considered adequately addressed."
    Core Performance (Data Recording Accuracy)Device meets specifications for recording actuation, inhaler shake, inhaler orientation, inhalation coordination, inspiratory strength and durationPassed - "Device was verified to meet specifications and the correct functionality and compatibility for the HTS with the concerned MDI inhalers was verified"
    Service LifeAt least 1 year service lifePassed - "Supports 1 year service life"
    Shelf-LifeAt least 2 years shelf lifePassed - "Supports 2 years shelf life"
    Transportation ImpactTransport has no impact on device (ASTM 4169)Passed - "confirmed the transport has no impact on device."

    Study Details (Based on available information and limitations)

    Given the explicit statement that "No clinical data was necessary to determine the substantial equivalence of this device," the following sections reflect this limitation. The "study" refers to the non-clinical verification and validation activities.

    1. A table of acceptance criteria and the reported device performance:

      • (Provided above, based on non-clinical testing outcomes).
    2. Sample sizes used for the test set and the data provenance:

      • Test Set Sample Size: Not applicable in the context of a clinical test set. For non-clinical performance testing (e.g., electrical safety, software validation, sensor accuracy), the sample sizes would refer to the number of devices or test iterations used. This specific detail is not provided in the document.
      • Data Provenance: Not applicable in the sense of patient data. The tests were performed in a lab or testing facility environment.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. No clinical ground truth experts were used as no clinical data was required. Ground truth for non-clinical performance (e.g., whether a sensor accurately detects an actuation) would be established by validated test methods and reference standards, not human expert consensus.
    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

      • Not applicable. There was no human expert adjudication as no clinical test set with subjective interpretations was used.
    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done:

      • No. The document explicitly states "No clinical data was necessary." Therefore, no MRMC study comparing human readers with and without AI assistance was performed.
    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • Yes, implicitly. The "Performance Testing" section confirms that the device was "verified to meet specifications" and its "correct functionality and compatibility" was verified. This implies standalone performance testing of the device's ability to record and analyze data from the MDI. The "algorithm" itself (which processes sensor data to identify events like actuation, shake, etc.) would have been validated against controlled physical actions.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • Instrumental/Physical Ground Truth: For the non-clinical performance tests, the "ground truth" would be established by controlled physical inputs and reference measurements. For example:
        • For "actuation," the ground truth would be a definitively measured actuation event.
        • For "inhaler shake," the ground truth would be a quantitatively measured shaking motion.
        • For software functionality, the ground truth would be predefined correct outputs for given inputs.
    8. The sample size for the training set:

      • Not applicable / Not specified. This device is an electronic data capture accessory. While it uses sensors and potentially algorithms to interpret movements, the document doesn't indicate that it employs machine learning or AI that would require a "training set" in the typical sense (e.g., for image classification or complex pattern recognition). Its function seems to be based on pre-defined thresholds and sensor data processing rather than adaptive learning from a large training dataset. If any "calibration" or initial parameter setting was done, the size of that dataset is not provided.
    9. How the ground truth for the training set was established:

      • Not applicable. As no training set is indicated.
    Ask a Question

    Ask a specific question about this device

    K Number
    K250583

    Validate with FDA (Live)

    Date Cleared
    2025-06-20

    (113 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Trade/Device Name:* AdheResp Smart Breath-actuated Mesh Nebulizer
    Regulation Number: 21 CFR 868.5630
    Respironics AAD** | |
    | K250583 | K202171 | K042991 | |
    | Classification | 21 CFR 868.5630
    CAF - Nebulizer - Direct patient interface | 21 CFR 868.5630 CAF - Nebulizer - Direct patient interface
    | 21 CFR 868.5630 CAF - Nebulizer - Direct patient interface | Similar |
    | Indications for use |

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AdheResp Smart Breath-actuated Mesh Nebulizer is a system to aerosolize liquid medications for inhalation for patients ranging from pediatrics equal to or greater than 5 years old to adults who can coordinate breathing.

    The environment of use are Hospital/institutional settings, home care use, schools, and long-term care facilities.

    Device Description

    The AdheResp Smart Breath-actuated Mesh Nebulizer consists of a main unit, medication reservoir, mouthpiece, key tag and charging cable, or power adapter. The medication reservoir could be further separated into a medication container and an aerosol chamber.

    Principle of Operation: There are two key features in the AdheResp Smart Breath-actuated Mesh Nebulizer, which are vibrating mesh nebulization and breath-actuation functions. The AdheResp Smart Breath-actuated Mesh Nebulizer is an active mesh nebulizer. Active mesh nebulizers operate by electrically activating a piezoelectric (PZT) ceramic element that rapidly contracts and expands when applied a voltage to it. The vibrations of the PZT are transmitted to the mesh membrane, which is in contact with the liquid medication loaded in the medication container. This vibration pushes the liquid or suspension through the fine conical holes of the mesh, forming aerosol droplets for the user to inhale.

    AI/ML Overview

    This document is a 510(k) clearance letter for the AdheResp Smart Breath-actuated Mesh Nebulizer. It outlines the device's characteristics and its equivalence to predicate devices, particularly focusing on performance data related to aerosol delivery.

    Here’s the breakdown of the acceptance criteria and the study that proves the device meets them, based on the provided text:

    Important Note: The provided text is a 510(k) summary and clearance letter. It summarizes findings and states that acceptance criteria were met, but it does not provide the detailed study protocols, raw data, or the explicit acceptance criteria values themselves in a direct, quantifiable manner for all aspects. Instead, it presents comparative performance data and lists categories of testing. Therefore, some information will be inferred from the context or noted as 'not explicitly stated' if the document does not provide it.


    1. Table of Acceptance Criteria and Reported Device Performance

    The document doesn't explicitly state quantitative acceptance criteria for each parameter in a "limit" vs. "result" format. Instead, it presents comparative performance data against a predicate device and states that the subject device "met its acceptance criteria" and that its performance is "similar." For the purpose of this table, I will present the reported performance of the Subject Device and mention the comparison to the Predicate. The implicit acceptance criterion for the comparative performance data is that the subject device's performance is demonstrably non-inferior or similar to the predicate.

    Acceptance Criterion (Implicit)Reported Device Performance (Subject Device)
    Particle Size (MMAD): Similar to predicate device15 LPM: Albuterol 3.98 ±0.18 µm, Ipratropium 3.984 ±0.11 µm, USP Cromolyn 4.07 ±0.14 µm (Predicate generally higher MMAD)
    30 LPM: Albuterol 3.48 ±0.15 µm, Ipratropium 3.39 ±0.21 µm, USP Cromolyn 3.58 ±0.15 µm (Predicate generally higher MMAD)
    Geometric Standard Deviation (GSD): Similar to predicate15 LPM: Albuterol 1.82 ±0.03, Ipratropium 1.94 ±0.10, USP Cromolyn 1.88 ±0.02 (Predicate generally higher GSD)
    30 LPM: Albuterol 1.89 ±0.09, Ipratropium 1.98 ±0.16, USP Cromolyn 1.90 ±0.07 (Predicate generally higher GSD)
    Total Delivered Dose (mg): Similar to predicate15 LPM: Albuterol 4.25 ±0.36, Ipratropium 0.45 ±0.07, USP Cromolyn 16.23 ±1.35 (Subject generally slightly higher or similar to Predicate)
    30 LPM: Albuterol 3.83 ±0.29, Ipratropium 0.40 ±0.04, USP Cromolyn 14.65 ±1.09 (Subject generally slightly higher or similar to Predicate)
    Respirable Dose <5µm [mg]: Similar to predicate15 LPM: Albuterol 2.71 ±0.32, Ipratropium 0.28 ±0.03, USP Cromolyn 10 ±0.85 (Subject generally higher than Predicate)
    30 LPM: Albuterol 2.67 ±0.21, Ipratropium 0.27 ±0.03, USP Cromolyn 9.95 ±0.71 (Subject generally higher than Predicate)
    Coarse Particle Dose <4.7µm [mg]: Similar to predicate15 LPM: Albuterol 1.47 ±0.10, Ipratropium 0.15 ±0.02, USP Cromolyn 5.85 ±0.65 (Subject generally lower or similar to Predicate)
    30 LPM: Albuterol 1.05 ±0.28, Ipratropium 0.11 ±0.01, USP Cromolyn 4.55 ±0.72 (Subject generally lower or similar to Predicate)
    Fine Particle Dose <4.7µm [mg]: Similar to predicate15 LPM: Albuterol 2.56 ±0.30, Ipratropium 0.27 ±0.03, USP Cromolyn 9.41 ±0.65 (Subject generally higher than Predicate)
    30 LPM: Albuterol 2.54 ±0.21, Ipratropium 0.26 ±0.03, USP Cromolyn 9.46 ±0.48 (Subject generally higher than Predicate)
    Ultra-Fine Particle Dose <1µm [mg]: Similar to predicate15 LPM: Albuterol LOD, Ipratropium 0.01 ±0.00, USP Cromolyn LOD (Similar to Predicate)
    30 LPM: Albuterol 0.21 ±0.06, Ipratropium 0.02 ±0.01, USP Cromolyn 0.58 ±0.05 (Similar to Predicate)
    Nebulization Rate: Must meet specified rate>0.25 ml/min (Similar to predicate)
    Inter- and Intra-sample Variability: Must meet criteriaMet acceptance criteria (no specific values given)
    Minimum Breath Actuation Tests: Must meet criteriaMet acceptance criteria (no specific values given)
    Biocompatibility (ISO 10993 & ISO 18562): Must pass testsApplicable ISO 10993 and ISO 18652 testing was performed and passed.
    Reprocessing, Sterility, and Shelf-Life: Must pass testsCleaning Validation, Aging, Simulated Life (cleaning, aging, drop) were performed and passed. (implicitly met acceptance criteria related to these tests)

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set:
      • For the comparative performance testing (Breath Actuated Particle Characterization): "Testing was performed with 3 samples of each device in triplicate with the 3 drugs." This implies $3 \text{ devices} \times 3 \text{ replicates} = 9$ runs per drug per flow rate for both the subject and predicate devices.
    • Data Provenance: Not explicitly stated (e.g., country of origin). The study is non-clinical bench testing ("Bench testing," "Non-Clinical Testing Summary"), meaning it's a controlled lab environment, not patient data. It is a prospective study in the sense that the tests were conducted specifically for this submission.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    • Number of Experts: Not applicable. This device is a nebulizer, and the tests described are bench tests (e.g., particle size, dosage, flow rates). These are physical measurements, not interpretations of medical images or patient conditions that would require expert human readers to establish ground truth.
    • Qualifications of Experts: N/A, as noted above.

    4. Adjudication Method for the Test Set

    • Adjudication Method: Not applicable. This is not a study involving human interpretation of data, where adjudication of disagreements would be necessary. The performance data is derived from direct and repeatable physical measurements.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    • MRMC Study: No. An MRMC study is typically performed for AI/CADe (Computer-Assisted Detection/Diagnosis) devices that assist human readers in interpreting medical images. This device is a nebulizer, a drug delivery system, and its performance is evaluated through bench testing.

    • Effect Size of Human Readers' Improvement: Not applicable, as no MRMC study was performed.


    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    • Standalone Performance: Yes, in essence. The "AdheResp Smart Breath-actuated Mesh Nebulizer" itself has an algorithm for "Breath Actuation" that "Measures breath and averages the cycle, then delivers aerosol during the designated period." The "Breathe Actuated Particle Characterization Performance Comparison" is a standalone evaluation of the device's physical output based on this internal algorithm responding to simulated breathing patterns (15 LPM and 30 LPM). There is no "human-in-the-loop" for the output of the device itself.

    7. The Type of Ground Truth Used

    • Type of Ground Truth: The ground truth for this device's performance is established by standardized laboratory measurements using traceable equipment and protocols (e.g., measuring particle size, drug quantity, flow rates) under controlled conditions. This is considered an objective physical truth, not a subjective interpretation. The comparison is made against a legally marketed predicate device's performance.

    8. The Sample Size for the Training Set

    • Training Set Sample Size: Not applicable. This device is a physical medical device (nebulizer) with an embedded algorithm, not a machine learning/AI model that requires a "training set" of data in the typical sense for image recognition or diagnostic purposes. The device's "algorithm" is for controlling the nebulization based on breath patterns, which would be developed through engineering and control system design, not data-driven machine learning.

    9. How the Ground Truth for the Training Set Was Established

    • Ground Truth for Training Set Establishment: Not applicable, as there is no "training set" in the context of a machine learning model. The "ground truth" for the device's operational parameters (like breath-actuation logic or aerosol delivery range) would be based on established engineering principles, physiological understanding of human breathing, and clinical requirements for drug delivery, validated through rigorous bench testing and potentially human factors testing, though the latter is not detailed in this summary.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242354

    Validate with FDA (Live)

    Device Name
    AllNEB
    Date Cleared
    2025-04-29

    (264 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Petersburg, Florida 33704

    Re: K242354
    Trade/Device Name: AllNEB
    Regulation Number: 21 CFR 868.5630
    Common/Usual Name:** Nebulizer
    Classification Name: Nebulizer (direct patient interface) 21CFR 868.5630
    Common/Usual Name:** Nebulizer
    Classification Name: Nebulizer (direct patient interface) 21CFR 868.5630
    Trudell Medical International | |
    | Prescriptive | Rx | Rx | Similar |
    | Classification | 21 CFR 868.5630

    • CAFNebulizer - Direct patient interface | 21 CFR 868.5630 - CAFNebulizer - Direct patient
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    AllNEB Breath Actuated Nebulizer is intended for adults and pediatric patients over 5 years old, who are under the care or treatment of a licensed healthcare provider or physician. AllNEB is intended for the administration of aerosolized medication prescribed by a physician or healthcare professional. AllNEB is to be used at home or in hospitals and clinics.

    Device Description

    AllNEB is a jet nebulizer intended to administer medication (prescribed by a physician or health care provider) in the form of an aerosol for patient inhalation. It operates in conjunction with a compressed air source and a liquid medication. The subject device is designed to produce and deliver aerosolized medication only during the patient inspiratory cycle, reducing fugitive emissions to the environment. It can be used in hospitals, clinics and in the home.

    AI/ML Overview

    This document is a 510(k) clearance letter for a medical device called "AllNEB Breath Actuated Nebulizer." It demonstrates the device's substantial equivalence to a legally marketed predicate device, the AeroEclipse II Breath Actuated Nebulizer (K053605).

    The core of the acceptance criteria and proof revolves around comparative performance testing, showing that the AllNEB device performs similarly to the predicate device across various aerosolization metrics.

    Here's an analysis of the acceptance criteria and the study that proves the device meets them, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria for this device are implicitly derived from the performance of the predicate device. The goal is to demonstrate "substantial equivalence," meaning the new device performs similarly to the predicate. The performance of the predicate device, AeroEclipse II Breath Actuated Nebulizer (K053605), serves as the "acceptance criteria," and the "Reported Device Performance" is that of the AllNEB device.

    The tables provided in the 510(k) summary (pages 7-16) present a direct comparison of various aerosolization parameters for both the AllNEB (Subject Device) and the AeroEclipse II (Predicate Device) under different conditions (Breath Actuated Mode, Constant-Output Mode, Adult settings, Pediatric settings, and Simulated Breathing).

    Key Performance Metrics (Acceptance Criteria are inferred to be "similar to predicate"):

    • MMAD (Mass Median Aerodynamic Diameter): A measure of the central tendency of the particle size distribution.
    • GSD (Geometric Standard Deviation): A measure of the spread or variability of the particle size distribution.
    • Total Dose Delivered: The total amount of medication delivered by the nebulizer.
    • Total Respirable Dose (0.5-5 µm): The amount of medication delivered as particles within the respirable range (able to reach the lower respiratory tract).
    • Coarse Particle Dose (>4.7 µm): The amount of medication delivered as larger particles.
    • Fine Particle Dose (<4.7 µm): The amount of medication delivered as smaller particles.
    • Ultra-Fine Particle Dose (<1.0 µm): The amount of medication delivered as very small particles.

    Example Excerpt from the Tables (Acceptance Criteria vs. Reported Performance):

    Metric (Albuterol Sulfate, Breath Actuated Mode – Adult settings, 5 lpm)Acceptance Criteria (Predicate)Reported Performance (AllNEB)Comment
    MMAD2.031.51Similar
    GSD1.702.43Similar
    Total Dose Delivered1,3671,228Similar
    Total Respirable Dose (0.5-5 um)847834Similar
    Coarse Particle Dose (>4.7 um)350218Similar
    Fine Particle Dose (<4.7 um)1,0171,010Similar
    Ultra-Fine Particle Dose (<1.0 um)307397Similar

    (Self-Correction: The "Similar" comment applies to all comparative data points presented in the submission, indicating that the observed differences were deemed acceptable for substantial equivalence for all the data points included in these tables.)

    The acceptance criterion for each measured value is that the AllNEB device's performance is "similar" to that of the predicate device. The tables, consistently marked with "Similar" in the comment column, indicate that this criterion was met for all tested parameters and conditions.

    2. Sample Size Used for the Test Set and Data Provenance

    The provided document does not specify the sample size (e.g., number of nebulizers tested, number of runs per nebulizer) used for the comparative performance testing. It presents the mean values for various measurements. The typical practice for such in vitro performance testing of nebulizer devices would involve multiple repetitions to ensure reproducibility and statistical validity, but the exact N is not given here.

    The data provenance is also not explicitly stated regarding the country of origin or whether it was retrospective or prospective. However, given that this is a 510(k) submission for a new device, the performance testing would undoubtedly be prospective and conducted by the manufacturer (Enchant Tek Co. Ltd.) as part of their pre-market submission requirements. The location of the sponsor (Taipei, TW) suggests the testing likely occurred in Taiwan or through a contract research organization.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    This document describes the performance testing of a physical medical device (nebulizer) based on in vitro aerosolization characteristics, not a diagnostic AI/ML algorithm that requires expert adjudication of medical images or patient data.

    Therefore, the concept of "experts used to establish the ground truth" in the sense of medical professionals (e.g., radiologists, pathologists) is not applicable here. The "ground truth" for the performance data is established by the methods and equipment used for aerosol particle sizing and dose measurement (e.g., cascade impactors, spectrophotometry), which are standard industry practices and governed by international standards (e.g., ISO 27427 for nebulizing systems). The "experts" would be the engineers and technicians proficient in running these highly standardized tests.

    4. Adjudication Method for the Test Set

    As explained above, since this is a performance test for a physical device, not an AI/ML diagnostic system based on human interpretation, an "adjudication method" (like 2+1 or 3+1 reviewer consensus for image reads) is not applicable. The data are quantitative measurements obtained through standardized laboratory procedures.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    No, an MRMC comparative effectiveness study was not conducted. This type of study is typically performed for diagnostic devices (especially those involving interpretation of medical images or signals) to assess how human performance (e.g., accuracy, efficiency) changes with and without AI assistance. The AllNEB is a drug delivery device, not a diagnostic tool requiring human interpretation of output.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done

    Not Applicable. This question is relevant for AI/ML devices where the algorithm's performance can be evaluated independently. The AllNEB is a mechanical device, and its performance is inherently "standalone" in terms of its aerosolization characteristics (it functions as designed regardless of a human interface beyond its intended use).

    7. The Type of Ground Truth Used

    The "ground truth" for the device's performance is established by physical measurements and testing using standardized laboratory equipment and methods. These methods quantitatively assess:

    • Particle size distribution (MMAD, GSD)
    • Drug delivery efficiency (Total Dose Delivered, Respirable Dose, etc.)

    These measurements are considered the objective "ground truth" for the device's physical performance characteristics. The comparison is made against the results obtained with the predicate device using the same methodologies.

    8. The Sample Size for the Training Set

    Not Applicable. This device is a mechanical nebulizer, not an AI/ML algorithm that requires a "training set."

    9. How the Ground Truth for the Training Set was Established

    Not Applicable. As there is no training set for a mechanical device, there is no ground truth to be established for it.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242667

    Validate with FDA (Live)

    Date Cleared
    2025-01-15

    (132 days)

    Product Code
    Regulation Number
    868.5630
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K242667

    Trade/Device Name: AeroChamber2go Anti-Static Valved Holding Chamber Regulation Number: 21 CFR 868.5630
    Name: Holding Chambers, Direct Patient Interface Medical Specialty: Anesthesiology Requlation Number: 868.5630
    Name: Holding Chambers, Direct Patient Interface Medical Specialty: Anesthesiology Requlation Number: 868.5630
    | Similar |
    | RegulationNumber | 21 CFR 868.5630

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This product is intended to be used by patients (5+ years) who are under the care or treatment of a physician or licensed healthcare professional. The device is intended to be used by these patients to administer aerosolized medication from most pressurized Metered Dose Inhalers. It is a single patient, multiple use device intended for home use.

    Device Description

    The AeroChamber2go* Anti-Static Valved Holding Chamber (VHC) is a portable holding chamber intended to be used by patients (5+ years) who are under the care or treatment of a physician or licensed healthcare professional. The device is intended to be used by these patients to administer aerosolized medication from most pressurized Metered Dose Inhalers. It is a single patient, multiple use device intended for home use. This device is not used with a specific druq nor is it distributed with such drugs.

    AI/ML Overview

    The provided text is a 510(k) summary for a medical device (AeroChamber2go Anti-Static Valved Holding Chamber). It describes the non-clinical testing performed to demonstrate substantial equivalence to a predicate device.

    It does NOT describe a study that proves the device meets the acceptance criteria of an AI/ML model for an image analysis task.

    Therefore, I cannot fulfill your request for information related to AI/ML model performance, ground truth, expert adjudication, or MRMC studies based on this document. The document pertains to the physical and chemical properties of a medical device, not a software-driven diagnostic or image analysis tool.

    The "acceptance criteria" discussed in this document refer to the device's mechanical, material, and aerosol delivery performance characteristics, not the performance of an AI system.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 24