    510k Summary Text (Full-text Search) :

    Flow Humidified Oxygen Delivery Device |
    | Regulation Number: | 21 CFR 868.5454
    | 21 CFR 868.5454

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BONHAWA Respiratory Humidifier is intended to provide high flow warmed and humidified respiratory gases for administration to spontaneously breathing patients 20 kg and up, child to adults in hospitals. It adds heat and moisture to the flow of gases. The flow may be from 2 to 70 L/min depending on the patient interface.

    The BONHAWA Respiratory Humidifier provides high flow gases with simultaneous oxygen delivery to spontaneously breathing patients without bypassed upper airways in hospitals.

    Device Description

    The BONHAWA Respiratory Humidifier is a heated humidifier with integrated blower, heater plate and heated breathing circuit that delivers warm and humidified respiratory gas to a patient via nasal cannula. A blower inside the device blends the externally provided oxygen with entrained filtered air and controls the gas flow rate delivered to the patient per the professional user established setting. An internal oxygen sensor monitors and reports the delivered oxygen concentration. The patient interface, heated breathing circuit chamber and chamber adapter are single use.

    AI/ML Overview

    The provided text is a 510(k) Premarket Notification for the BONHAWA Respiratory Humidifier. It focuses on demonstrating substantial equivalence to a predicate device (Airvo 2 Humidifier series) and a reference device (Airvo 3 High Flow Humidified Oxygen Delivery Device) based on technical characteristics and performance testing against recognized consensus standards.

    However, the document does not contain information about acceptance criteria and a study that proves the device meets those criteria in the context of an AI/ML medical device. The device described is a physical medical device (a respiratory humidifier), not an AI/ML-driven diagnostic or therapeutic software. Therefore, the specific questions related to AI/ML device performance metrics (e.g., sample size for test sets, data provenance, expert ground truth, MRMC study, standalone performance, training set details) are not applicable and are not addressed in this filing.

    The "Performance Testing" section (Page 11) states that substantial equivalence is based on:

    • Product validation and risk mitigation verification testing.
    • Meeting pertinent recognized consensus standards:
      • ISO 80601-2-74:2017 (Respiratory humidifying equipment)
      • IEC 60601-1:2005+AMD1:2012 (General requirements for basic safety and essential performance)
      • IEC 60601-1-2:2014 +A1:2020 (Electromagnetic disturbances)
      • IEC 60601-1-8 (Alarm systems)
      • ISO 10993-1 (Biocompatibility)
      • ISO 18562-1 (Biocompatibility of breathing gas pathways).

    The table "Comparison of Technological Characteristics" (Pages 6, 7, 8, 9) effectively serves as the "acceptance criteria" through a direct comparison to the predicate and reference devices, demonstrating that the subject device's specifications are either identical or offer non-inferior performance without raising new safety or effectiveness concerns.

    Given the nature of the device, the following points address the relevant aspects of your request based on the provided text:

    1. A table of acceptance criteria and the reported device performance:

    The acceptance criteria are implicitly defined by the substantial equivalence comparison to the predicate and reference devices, and adherence to relevant consensus standards. The "reported device performance" is presented through direct specifications and the claim of meeting the standards.

    AttributeAcceptance Criteria (Predicate/Reference Standard)Reported Device Performance (BONHAWA Respiratory Humidifier)Notes/Differences
    Classification NameHumidifier, Respiratory Gas (Direct Patient Interface) (Predicate)Humidifier, Respiratory Gas (Direct Patient Interface)Similar to the predicate.
    Regulation Number21 CFR 868.5450 (Predicate)21 CFR 868.5450Similar.
    Indications for UseHigh flow warmed and humidified respiratory gases for spontaneously breathing patients. (Predicate similar, Reference broader to include infants and sub-acute facilities, and bypassed upper airways).High flow warmed and humidified respiratory gases for administration to spontaneously breathing patients 20 kg and up, child to adults in hospitals. Without bypassed upper airways.The subject device includes a more specific lower weight limit (20kg and up) and explicitly excludes use with bypassed upper airways, aligning more closely with the predicate's narrower scope for non-bypassed upper airways. The overall intended use of delivering high flow breathing gases with humidification remains similar.
    Environment of UseHospitals (Predicate: Hospitals and long-term care facilities; Reference: Hospitals and sub-acute facilities)HospitalsSimilar but not for long-term facility use as the predicate.
    Patient PopulationPediatric to Adult (Predicate) / Infant to Adults (Reference)Pediatric patients, 20kg and above, and AdultSimilar. More specific starting weight.
    Breathing TypeSpontaneously breathingSpontaneously breathingSimilar.
    Flow RatePredicate: up to 60 L/min; Reference: up to 70 L/minPediatric: 2 - 25 L/min, Adults: 10 - 70 L/minSubject device's adult flow rate (70 lpm) matches the reference device and is higher than the predicate (60 lpm), which is considered acceptable for achieving intended FiO2 by matching patient inspiratory demand.
    Operating PrincipleConstant flow of warmed, humidified gas delivery via blower and humidifierConstant flow of warmed, humidified gas delivery via blower and humidifierSimilar.
    Oxygen Input SourceLow-Pressure Oxygen (LPO) low-pressure connector (from rotameter)Low-Pressure Oxygen (LPO) low-pressure connector (from rotameter)Similar. The reference device also has a High-Pressure Oxygen (HPO) inlet.
    Humidity SourceHeated humidification chamberHeated humidification chamberSimilar.
    Humidity PerformanceAt 37°C >= to 33mg/L, At 34°C >= to 12mg/L, At 31°C >= to 12mg/LAt 37°C >= to 33mg/L, At 34°C >= to 12mg/L, At 31°C >= to 12mg/LSimilar.
    Temperature Range31 - 37 °C31 - 37 °C (Adult: 37°C, 34°C, 31°C; Pediatric: 34°C)Similar.
    Ambient Operating Temp18 – 28 °C18 – 28 °CSimilar.
    AlarmsVisual and audible alarm system; Mute buttonVisual and audible alarm system; Mute buttonSimilar.
    Patient InterfacesNasal cannula, Unsealed tracheostomy connector, Unsealed mask adapter (Predicate/Reference)Nasal cannulaSimilar for the patient without bypassed airway (which is the stated indication). The subject device does not include tracheostomy or mask adapter interfaces.
    Heated Breathing TubeSingle-lumen, spiral heater wiresSingle-lumen, spiral heater wiresSimilar.
    Duration of Use14 Days single patient use14 Days single patient useSimilar.
    Oxygen ConcentrationInput Oxygen < 60 lpm (Predicate); Input Oxygen < 70 lpm (Reference)Input Oxygen < 80 lpm; O2 concentration mixing of 21 to 100%Substantially equivalent, allowing for a greater O2 flow input, which facilitates attainment of intended FiO2 by matching patient inspiratory demand.
    Non-Clinical TestingCompliance with IEC 60601-1, IEC 60601-1-2, ANCSI/AAMI ES 60601-1, EN 60601-1, IEC 60601-1-8, ISO 80601-2-74 (Predicate/Reference)Compliance with listed standards (IEC 60601-1, IEC 60601-1-2, ANSI/AAMI ES 60601-1, EN 60601-1, IEC 60601-1-8, ISO 80601-2-74, ISO 80601-2-55 (additional))Similar, demonstrating adherence to recognized safety and performance standards. The subject device specifically lists ISO 80601-2-55:2018 (Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors) in its non-clinical testing section, which is not explicitly listed for the predicate/reference in the table but aligns with its function.
    BiocompatibilityCompliance with ISO 10993-5, ISO 10993-10 (Predicate/Reference also include ISO 10993-11, ISO 10993-18 and ISO 18562-1)Compliance with ISO 10993-5:2009, ISO 10993-10:2010, ISO 18562-1Similar patient contact and duration of use, demonstrating materials safety.
    System ComponentsDevice, power cord, water chamber, water chamber adapter, heated breathing circuit, cannula (Similar for predicate/reference)Device, power cord, water chamber, water chamber adapter, heated breathing circuit, cannulaSame. Substantially equivalent.
    Device Weight4.8 lb (predicate) / 9.8 lb (reference)5.7 lb (unit)Falls within the range of the predicate and reference, considered substantially equivalent as it does not raise new safety or effectiveness concerns.
    Dimensions (H x W x D)11.6" x 6.7" x 6.9" (predicate) / 11.6" x 8.1" x 7.5" (reference)12.5" x 8.7" x 7.2"Considered substantially equivalent.
    Technological CharacteristicsIntake from User chosen flowmeter is mixed by a blower and gas is delivered to the patient after mixing by passing over a heated water chamber to add humidity. Gas is delivered via a heated breathing circuit and cannula interface. (Predicate/Reference)Intake from User chosen flowmeter is mixed by a blower and gas is delivered to the patient after mixing by passing over a heated water chamber to add humidity. Gas is delivered via a heated breathing circuit and cannula interface.Similar. There are no fundamental scientific principle differences. The differences (e.g., higher flow rate, graphical user interface) do not alter the safety or effectiveness or raise new concerns.
    Graphical User InterfaceNot explicitly mentioned in predicate/reference comparison table, but implied by functional description.Graphical user interface - to better inform users of the device function and attainment of intended use.This is a key characteristic differing from the predicate, intended to improve user information and use. The document states this difference does not alter safety or effectiveness.
    User Supplied AccessoriesOxygen source, oxygen flowmeter, oxygen tubingOxygen source, oxygen flowmeter, oxygen tubingIdentical.
    Power Input110-115 V, 50-60 Hz, 2.2-2.4 A max (Predicate/Reference)110-120 V, 50-60 Hz, 1.2 A (1.4 A max)Substantially equivalent. The subject device has a lower maximum current (1.4A vs 2.4A).
    Heater Plate Max Power160 W (Predicate); Not stated (Reference)150 WLower wattage reduces heat and power compared to the predicate, but is still considered substantially equivalent as it does not raise new safety/effectiveness concerns regarding the humidification performance (which is met).
    BatteryNone (Predicate) / Lithium Ion (Reference)NoneSimilar to the predicate.
    Operating ConditionsAmbient temperature 18-28°C, Humidity 10-95%, Altitude 0-2000m (Predicate)Ambient temperature 18-28°C, Humidity 10-95%, Altitude 0-2000m (6,000 ft)Similar to the predicate.

    2. Sample sized used for the test set and the data provenance:

    This information is not provided as it's a physical device and not an AI/ML model evaluated on a data set. The performance testing relies on engineering verification and validation against specified standards. Data provenance (country of origin, retrospective/prospective) is not relevant for this type of device submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    Not applicable, as this is not an AI/ML device requiring expert annotation for ground truth.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    Not applicable.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable, as this is not an AI/ML-assisted diagnostic device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Not applicable. There is no AI/ML algorithm involved to be evaluated in standalone mode.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    Not applicable in the context of AI/ML. The "ground truth" for this device's performance is objective measurement against specified engineering standards (e.g., flow rate, temperature, humidity output) and safety benchmarks, as well as biocompatibility testing.

    8. The sample size for the training set:

    Not applicable, as there is no AI/ML model that requires a training set.

    9. How the ground truth for the training set was established:

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221338

    Validate with FDA (Live)

    Device Name
    F&P Airvo 3
    Date Cleared
    2023-01-27

    (263 days)

    Product Code
    Regulation Number
    868.5454
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Place Auckland, 2013 New Zealand

    Re: K221338

    Trade/Device Name: F&P Airvo 3 Regulation Number: 21 CFR 868.5454
    /High Velocity Humidified Oxygen Delivery Device |
    | Primary Regulatory Class | Class II (21 CFR §868.5454
    Regulation | Class II, Regulation: 21 CFR §868.5454
    | Class II, Regulation: 21 CFR §868.5454
    performed to demonstrate substantial equivalence and to meet the Special Controls requirements of 21 CFR 868.5454

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Airvo 3 is intended to provide high flow warmed and humidified respiratory gases for administration to spontaneously breathing infant, child, adolescent and adult patients in hospitals and sub-acute facilities. It adds heat and moisture to the flow of air, or blended air/medical oxygen mixture, and assures the user of the air/oxygen mixture using an integrated oxygen analyzer and visual display. The flow may be from 2 to 70 L/min depending on the patient interface. The Airvo 3 provides high flow gases with simultaneous oxygen delivery to spontaneously breathing patients with or without bypassed upper airways in hospitals and sub-acute facilities.

    The Airvo 3 provides high flow gases with simultaneous oxygen delivery through nasal cannula interfaces to augment the breathing of spontaneously breathing patients suffering from respiratory distress and/or hypoxemia in the hospital setting. The Airvo 3 is not intended to provide total ventilatory requirements and is not for use during field transport.

    Device Description

    The F&P Airvo 3 is a high-flow device comprised of heated humidifier with integrated flow source, intended to treat spontaneously breathing patients, pediatrics and adults, who would benefit from receiving high flow, warmed and humidified entrained air and oxygen (if required).

    The F&P Airvo 3 can be reprocessed for use on multiple patient interfaces, heated breathing tube, and water chambers are disposable and are for single patient use only, however, the internal outlet elbow is high-level-disinfected for multi-patient use.

    The F&P Airvo 3 is comprised of two main connected functional units: the blower and the humidifier.

    The blower is a motorized fan assembly that provides air flow. The flow is adjustable, where a separate source of oxygen independently controlled can be input and mixed with the entrained air. The blower assembly output connects directly to a humidification chamber at the front of the device.

    The second functional unit of the F&P Airvo 3 is a heated passover humidifier. The water is contained in a humidification chamber positioned on a heater plate at the front of the unit. The gas is warmed and humidified in the chamber to the dew point set temperature, transported through the heated breathing tube and delivered to the patient through the selected interface.

    AI/ML Overview

    The provided text pertains to the FDA 510(k) clearance of the F&P Airvo 3 device, a high flow humidified oxygen delivery device. It outlines the regulatory process and demonstrates substantial equivalence to predicate devices, focusing on non-clinical performance data and adherence to recognized standards.

    However, the document does not contain information regarding:

    • Specific acceptance criteria values and reported device performance in a table for each performance test.
    • Sample sizes used for test sets, their data provenance (country, retrospective/prospective).
    • Number and qualifications of experts for ground truth establishment.
    • Adjudication methods.
    • Multi-reader multi-case (MRMC) comparative effectiveness studies.
    • Standalone algorithm performance studies.
    • The specific type of ground truth used (e.g., pathology, outcomes data), if applicable to this type of device.
    • Sample size for training sets.
    • How ground truth for the training set was established.

    The document primarily focuses on non-clinical (bench) testing and adherence to recognized standards to demonstrate substantial equivalence, rather than clinical study results with human participants or AI performance metrics.

    Therefore, I can provide the available information from the document, but many of your requested points cannot be answered based on the input.


    Available Information from the Document:

    1. A table of acceptance criteria and the reported device performance

    The document states that comparative performance testing was performed to demonstrate substantial equivalence and to meet the Special Controls requirements of 21 CFR 868.5454. It lists the categories of performance testing but does not provide a table with specific quantitative acceptance criteria or detailed reported device performance values for each.

    Test CategoryBasis for EvaluationSpecific Acceptance Criteria & Reported Performance
    Blending accuracyDemonstrates substantial equivalence and meets 21 CFR 868.5454 Special Controls requirements.Not specified in the document.
    Flow rate accuracyDemonstrates substantial equivalence and meets 21 CFR 868.5454 Special Controls requirements.Not specified in the document.
    Continuous use thermal stabilityDemonstrates substantial equivalence and meets 21 CFR 868.5454 Special Controls requirements.Not specified in the document.
    Humidification outputDemonstrates substantial equivalence and meets 21 CFR 868.5454 Special Controls requirements.Not specified in the document.
    BiocompatibilityISO 10993-1, ISO 18562-1 (recognized by FDA)."demonstrates an appropriate biocompatibility profile for the device." (No specific criteria/values provided.)
    Electrical SafetyANSI AAMI ES 60601-1:2005/(R)2012 and A1:2012"The system complies with... demonstrated the appropriate electrical safety profile for the device." (No specific criteria/values provided.)
    EMCIEC 60601-1-2:2014, AIM Standard 7351731 Rev. 2.00 2017-02-23"The system complies with... demonstrated the appropriate electromagnetic compatibility profile for the device." (No specific criteria/values provided.)
    AlarmsANSI AAMI IEC 60601-1-8:2006 and A1:2012Testing performed, implies compliance. (No specific criteria/values provided.)
    SoftwareFDA's Guidance for Industry and FDA Staff, "Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices.""Software verification, validation and hazard analysis was conducted, and documentation was provided as recommended." (No specific criteria/values provided.)
    Cleaning/ReprocessingAAMI TIR30:2011Outlet Elbow classified as semi-critical, subject to cleaning and high-level disinfection. (No specific criteria/values for cleaning effectiveness provided.)
    SpO2 Sensing (New Feature)Internal testing by F&P"F&P has conducted testing that demonstrates that the SpO2 and pulse rate values calculated by the pulse oximetry system are not corrupted during communication to the Airvo 3 and are displayed accurately on the user interface." (No specific criteria/values provided.)

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided in the document. The performance data summarized relates to non-clinical (bench) tests rather than human clinical studies.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    This information is not provided in the document. The device is a medical equipment (high flow humidified oxygen delivery device), not an imaging or diagnostic AI device that typically relies on expert ground truth for interpretation.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not provided in the document.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not provided in the document. The F&P Airvo 3 is a medical device, not an AI-assisted diagnostic or interpretation tool for human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This information is not provided in the document. This is not an AI algorithm but a physical medical device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    This information is not explicitly stated in detail. For physical performance tests (like blending accuracy, flow rate accuracy, thermal stability, humidification output), the "ground truth" would implicitly be defined by the measurement standards and calibrated reference equipment used during bench testing. For biocompatibility, it's adherence to ISO standards; for electrical safety, adherence to IEC/ANSI AAMI standards.

    8. The sample size for the training set

    This information is not provided in the document. This device does not appear to involve machine learning or AI models with "training sets" in the conventional sense.

    9. How the ground truth for the training set was established

    This information is not provided in the document. As noted above, this type of device does not typically have "training sets" or "ground truth" established in this manner.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221318

    Validate with FDA (Live)

    Device Name
    HVT 2.0
    Manufacturer
    Date Cleared
    2022-12-13

    (221 days)

    Product Code
    Regulation Number
    868.5454
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Drive Exeter, New Hampshire 03833

    Re: K221318

    Trade/Device Name: HVT 2.0 Regulation Number: 21 CFR 868.5454
    High Flow Humidified Oxygen Delivery Device |
    | Classification: | 21 CFR 868.5454
    performed to demonstrate substantial equivalence and to meet the Special Controls requirements of 21 CFR 868.5454

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The HVT 2.0 system provides high velocity nasal insufflation (HVNI) with simultaneous warmed and humidified respiratory gas delivery to augment breathing of spontaneously breathing adult and pediatric patients (5 kg and up) suffering from respiratory distress and/or hypoxemia in the hospital setting, via a small bore nasal cannula. HVT 2.0 is not intended to provide total ventilatory requirements of the patient and not for use during field transport. The flow rates may be from 5 to 45 liters per minute (BTPS).

    Device Description

    The HVT 2.0 System is comprised of hardware containing software, and single use disposables that are designed to deliver the same High Velocity Nasal Insufflation (HVNI) as the Vapotherm Precision Flow HVNI.

    The HVT 2.0 system consists of the HVT 2.0 hardware containing software, a Disposable Patient Circuit (DPC), and a patient interface (nasal cannula). The HVT 2.0 system utilizes an integrated internal blower to deliver warmed and humidified breathing gas at flows 5 to 45 L/min (BTPS) to spontaneously breathing patients, without the need of wall air or any pressurized air source. The addition of an external oxygen source (wall or tank for QAV indication) enables FiO2 delivery from 21% to 100%. The device incorporates a blender and flow sensors that allow the oxygen percentage and total gas flow to be set independently.

    The HVT 2.0 main hardware device contains all the electrical and electronic components including the electronic blender and flow controllers, and sensors to monitor the disposable patient circuit. The main hardware device has no water pathways and the gas pathway only contains dry gas at room temperature, and therefore does not require internal cleaning or disinfection.

    AI/ML Overview

    The available text does not describe an acceptance criteria and a study proving the device meets said criteria in the format requested. The document is a 510(k) summary for the HVT 2.0 device, which focuses on demonstrating substantial equivalence to a predicate device rather than presenting a performance study against predefined acceptance criteria for AI or automated system performance.

    Here's why the requested information cannot be extracted and what is provided instead:

    • 1. A table of acceptance criteria and the reported device performance: This is not present. The document includes a comparison table between the predicate and subject device (HVT 2.0) for various characteristics like Indications for Use, Patient Population, Flow Range, etc. While it lists "Temperature Accuracy" as "±2°C" and "Oxygen Accuracy" as "±2%", these are device specifications and not explicitly presented as "acceptance criteria" for a study in the context of an AI/algorithm performance. It then states "SAME" for the subject device, implying it meets these for equivalence.
    • 2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective): Not applicable. The document discusses "bench / performance testing" and "comparative performance testing" but does not detail sample sizes for these tests in a way that would be relevant to a "test set" for an algorithm. There is no mention of data provenance (e.g., country of origin, retrospective/prospective).
    • 3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience): Not applicable. This document does not describe the use of experts to establish a "ground truth" for a test set, as it does not involve the evaluation of an algorithm's diagnostic or predictive performance.
    • 4. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable for the same reasons as point 3.
    • 5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This summary does not describe any MRMC studies or AI assistance for human readers. The device (HVT 2.0) is a high-flow humidified oxygen delivery device, a physical medical device, not an AI or software-as-a-medical-device (SaMD) that typically undergoes such evaluations.
    • 6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. The device is not an algorithm. Its software is mentioned for verification and validation but not as a standalone performance entity.
    • 7. The type of ground truth used (expert concensus, pathology, outcomes data, etc.): Not applicable.
    • 8. The sample size for the training set: Not applicable, as there is no mention of a training set for an algorithm.
    • 9. How the ground truth for the training set was established: Not applicable.

    Summary of what is provided:

    The document describes the HVT 2.0, a High Flow Humidified Oxygen Delivery Device, and its comparison to a predicate device (Precision Flow HVNI). The main point is to demonstrate "substantial equivalence" of the HVT 2.0 to the predicate device, not to prove algorithm performance against specific criteria.

    The "studies" mentioned are non-clinical performance and bench testing, including:

    • Biocompatibility testing (leveraged from prior testing, compliant with ISO 10993-1)
    • Electrical safety and electromagnetic compatibility (compliant with IEC 60601-1 and IEC 60601-1-2)
    • Alarms testing (compliant with IEC 60601-1-8)
    • RFID testing (compliant with AIM 7351731)
    • Software verification, validation, and hazard analysis (compliant with FDA guidance for software and ISO 14971:2019)
    • Bench/Performance Testing, including:
      • Precision Flow and HVT 2.0 Comparison Testing (to demonstrate same HVNI technological characteristics and performance)
      • Oxygen accuracy/Blender Performance
      • Temperature accuracy/Thermal Stability
      • Flow rate accuracy
      • Humidification output (ISO 80601-2-74)
      • Patient contacting surface temperature/Thermal Safety
      • Volume of liquid exiting the humidification chamber outlet
      • Continuous use (Use Lifespan)
      • Operating environment
      • Nurse call compatibility
      • Usability/Human Factors
      • Cleaning Validation (for hardware)

    The conclusion is that "Any differences in technological characteristics of the devices do not raise different questions of safety and effectiveness based on the performance testing, further supported by the prior clearance of the Reference Device HVT 2.0, cleared under K203357. The devices are substantially equivalent."

    Ask a Question

    Ask a specific question about this device

    K Number
    DEN170001

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2018-04-10

    (462 days)

    Product Code
    Regulation Number
    868.5454
    Type
    Direct
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    NEW REGULATION NUMBER: 21 CFR 868.5454

    CLASSIFICATION: Class II

    PRODUCT CODE: OAV

    BACKGROUND

    Product Code: QAV Device Type: High flow humidified oxygen delivery device Class: II Regulation: 21 CFR 868.5454

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Precision Flow® HVNI is intended for use to add warm moisture to breathing gases from an external source for administration to a neonate/infant, pediatric and adult patients in the hospital and subacute institutions settings. It adds heat and moisture to a blended medical air/ oxygen mixture and assures the integrity of the precise air/oxygen mixture via an integral oxygen analyzer. The flow rates may be from 1 to 40 liters per minute via nasal cannula.

    Precision Flow® HVNI provides high velocity nasal insufflation (HVNI) with simultaneous oxygen delivery to augment breathing of spontaneously breathing patients suffering from respiratory distress and/or hypoxemia in the hospital setting. Precision Flow® HVNI is not intended to provide total ventilatory requirements of the patient and not for use during field transport.

    Device Description

    The Precision Flow® HVNI system delivers high flow rates of heated and humidified blended breathing gas through high flow nasal cannulas. The Precision Flow® HVNI system can connect to air and oxygen source. The Precision Flow® HVNI may be operated with limited performance at gas inlet pressures as low as 4 psi (28 kPa). For the full specified range of gas flows and oxygen percentages, both gas inlet pressures must be at minimum 40 psi (276 kPa).The main unit contains an integrated blender that delivers the targeted gas mixture to the disposable patient circuit (DPC). The Disposable Patient Circuit contains:

    • Water path: tubing from sterile water supply to vapor transfer cartridge
    • . Vapor transfer (humidification) cartridge: 2 types; low flow (1-8 lpm) and high flow (5-40 lpm)
    • Delivery Tube: triple lumen tubing
    • . Nasal Cannula

    The device automatically senses cartridge type. The available set temperature range is 33 °C to 39 °C. The device also contains a backup battery to provide power only for 15 minutes.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study information for the Precision Flow® HVNI, based on the provided text:

    Acceptance Criteria and Device Performance

    The acceptance criteria for the Precision Flow® HVNI are primarily non-clinical, focusing on safety, performance standards, software validation, and labeling requirements. The clinical studies establish safety and effectiveness by demonstrating non-inferiority or comparable outcomes to existing treatments.

    Acceptance Criteria CategoryAcceptance CriteriaReported Device Performance/Evidence
    Biocompatibility/MaterialsPatient-contacting components must be demonstrated to be biocompatible (Special Control 1). Tests include Cytotoxicity, Sensitization, Intracutaneous Reactivity, Extractables and Leachables, Volatile Organic Compounds (VOC), and Particulate Matter (PM2.5).All biocompatibility tests passed, demonstrating the biocompatibility of the device, in accordance with ISO 10993-1.
    Shelf Life/Reprocessing/SterilityCleaning instructions for reusable components must be validated (Special Control 3). Acceptance criteria for cleaning validation: no visible soil, protein level <6.4 micrograms/cm², TOC <12 micrograms/cm². Low-level disinfection validated by ≥ 6 log reduction of specified test organisms.Cleaning validation study met acceptance criteria: no visible soil, protein level <6.4 micrograms/cm², and TOC <12 micrograms/cm². Low-level disinfection demonstrated ≥ 6 log reduction of E. coli, S. aureus, K. pneumoniae, and P. aeruginosa.
    EMC/Electrical/Mechanical/Thermal SafetyElectrical safety, thermal safety, mechanical safety, electromagnetic compatibility, and radiofrequency identification (RFID) testing must be performed (Special Control 4). Standards: IEC 60601-1-2:2014, AAMI / ANSI ES60601-1:2005/(R) 2012 and A1:2012, AIM Standard 7351731 (RFID reference).Device passed tests in accordance with IEC 60601-1-2:2014, AAMI / ANSI ES60601-1:2005/(R) 2012 and A1:2012. Tested for RFID exposure using AIM Standard 7351731 as a reference.
    SoftwareSoftware verification, validation, and hazard analysis must be performed (Special Control 5). Adequate software documentation consistent with a "Major" level of software concern (FDA Guidance, May 11, 2005).Adequate software documentation provided. Software validation and verification testing demonstrated that the device met its design, implementation, and cybersecurity requirements.
    Non-clinical Performance TestingDevice performs as intended under anticipated conditions for use (Special Control 2). Specific tests: a. Alarm testing b. Continuous use thermal stability testing c. Humidity output testing d. Blender performance (FiO2 blending accuracy) Additional tests: Battery performance, Cannula pressure drop (blocked tube alarm not initiated). Standards: AAMI / ANSI / IEC 60601-1-8:2006 & A1:2012, ISO 8185:2007, ISO 80601-2-74.Blender performance: Verified set FiO2 at various flowrates (21%-100% FiO2) with high/low flow cartridges. Thermal Stability: Output temperature remained within specifications for 15 days across full range of settings, and another 15 days at max temp (43°C) and max flow (8/40 LPM). Battery performance: No change in set flow and FiO2 observed. Nasal cannula performance: Acceptable pressure drop at applicable flows, blocked tube alarm not initiated. Alarm testing, continuous use thermal stability, humidity output, and blender performance were implied to be successful as per "Additional testing".
    Clinical Effectiveness (Adults)Non-inferiority to NIPPV in avoidance of failure (including intubation/mechanical ventilation) within 72 hours of initiation (Primary Endpoints for Doshi et al. study).Doshi et al. study: Intubation within first 72 hours: 7% (HVNI) vs. 13% (NIPPV). Demonstrated non-inferiority (Wald p<0.001) for intubation rates. While arm failures (crossover) were higher in HVNI (26% vs 17%), the intubation rate was lower, suggesting clinical usefulness. Secondary findings: HVNI favored for pCO2 normalization at 240 min (p=0.02), physician perception (respiratory response, comfort/tolerance, simplicity of use), and patient perception of dyspnea was similar.
    Clinical Effectiveness (Neonates)Safety and effectiveness comparable to CPAP/nCPAP/NIPPV for respiratory distress/hypoxemia, without increasing adverse outcomes (pneumothorax, infection, ROP surgery, extubation failure, BPD, air leaks, IVH, NEC, sepsis). Non-inferiority for intubation rates within 72 hours of therapy initiation (Lavizzari et al. study).McQueen et al.: Compared to VON database (CPAP predominant), HFT did not increase pneumothorax (4.8% vs 4.4%) or nosocomial infection (14.8% vs 15.1%). Lower ROP surgery (2.2% vs 3.2%). Supported effectiveness and safety. Collins et al.: Non-inferior extubation failure rates for HFT (22%) vs nCPAP (34%). Similar clinical outcomes (BPD), trend for shorter supplemental oxygen in HFT. Improved nasal trauma score with HFT. Lavizzari et al.: Non-inferiority for primary endpoint (mechanical ventilation within 72 hrs). Failure rates: HFT (10.8%) vs nCPAP/BiPAP (9.5%). Lower bound of 95% CI (-6.0%) below zero met non-inferiority criteria. Similar secondary outcomes (duration of support, surfactant, air leaks, BPD). Kugelman et al.: Comparable failure to intubate rates for HFT (34.2%) vs NIPPV (31.6%). No clinically meaningful differences in secondary outcomes (air leak, nasal trauma, BPD, IVH, NEC, sepsis).
    LabelingLabeling must meet 21 CFR 801.109, include specific information (FiO2 ranges, flowrates, continuous monitoring warning, condensation warning, alarm description/function, not a CPAP device warning, aspiration risk warning) (Special Control 6).Labeling meets 21 CFR 801.109 and includes all specified warnings and descriptions as per Special Control 6.
    Adverse EventsNo device-related serious adverse events.In the Doshi et al. adult clinical study, there were no adverse events related to the use of the device. All adverse events were related to the underlying patient condition. The neonate studies also did not raise new safety concerns.

    Study Information

    Due to the nature of this particular device (high flow humidified oxygen delivery device) and the provided text, the "studies" are clinical trials and published literature, rather than an AI/ML-specific validation study with test sets, ground truth experts, or training sets in the typical sense. The regulatory submission leverages existing clinical evidence.

    For the Adult Clinical Study (Doshi et al.):

    1. Sample size used for the test set and the data provenance:

      • Sample Size: 204 adult patients (104 in HVNI arm, 100 in NIPPV arm).
      • Data Provenance: Multi-center, prospective, randomized clinical trial conducted at 5 sites. Country of origin not explicitly stated but implies US context for FDA submission.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • This is a clinical trial where clinical outcomes (e.g., intubation, failure to tolerate device, physiological parameters like O2 saturation, PaO2, PCO2, relief of respiratory distress, deteriorating medical status) were the ground truth. These outcomes were assessed by treating clinicians (physicians, nurses, respiratory therapists) at the study sites. The "experts" are the medical professionals directly involved in patient care and decision-making within the clinical trial setting. Specific qualifications beyond "physician" are not detailed in the text.
    3. Adjudication method for the test set:

      • Not explicitly stated as a formal adjudication panel in the typical AI/ML context. Treatment failure was defined by clear clinical criteria (need for intubation, device intolerance, failure to oxygenate/ventilate, failure to relieve distress, deteriorating medical status). These assessments are inherent to clinical practice and were likely made by the treating clinicians in real-time, within the trial's protocol.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No, this was not an MRMC study comparing human readers with and without AI assistance. It was a comparative effectiveness study between two medical devices/therapies (HVNI vs. NIPPV).
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • No, this device is a medical device for patient breathing support; it is not an AI algorithm performing a diagnostic task. Its performance is measured by its clinical impact on patients.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • Outcomes Data: Primary ground truth was clinical outcomes data, specifically "treatment failure rate, defined as the need for intubation, and arm failure rate, defined as the decision for crossover to the alternate therapy, within 72 hours of initiation of assigned therapy." Other outcomes included vital signs, blood gas analysis (e.g., pCO2), physician perception, and adverse events.
    7. The sample size for the training set:

      • Not applicable in the context of this device being a medical hardware system, not an AI/ML algorithm requiring a specific training set of patient data.
    8. How the ground truth for the training set was established:

      • Not applicable for the same reason as above.

    For the Neonate Patient Population (McQueen et al., Collins et al., Lavizzari et al., Kugelman et al.):

    1. Sample size used for the test set and the data provenance:

      • McQueen et al.: Retrospective cohort study. HFT group: Data from five centers, no specific n given for test set, but stated "used Vapotherm HVNI as their primary and predominant mode." Compared to Vermont Oxford Network (VON) database: 176,599 very low birth weight baby admissions (control/comparison data).
      • Collins et al.: 132 low birth weight infants (< 2500g, <32 weeks gestation). Randomized (67 HFT, 65 nCPAP). Data provenance: Randomized Controlled Trial.
      • Lavizzari et al.: Randomized trial, 298 infants (158 HFT, 158 nCPAP/BiPAP). Data provenance: Prospective, randomized clinical non-inferiority trial.
      • Kugelman et al.: 76 infants (<35 week gestational age, >1000g). Randomized (38 HFT, 38 NIPPV). Data provenance: Randomized Pilot Study.
      • Data Provenance for all neonate studies: Published literature, likely international based on author names and journal types, but not explicitly stated for each study.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Similar to the adult study, ground truth involved clinical outcomes assessed by treating medical professionals (neonatologists, nurses, etc.) within the context of their respective clinical trials or retrospective data collection. Specific expert qualifications beyond clinical roles are not detailed within the provided text.
    3. Adjudication method for the test set:

      • Not explicitly stated as a formal adjudication panel. Outcomes were generally defined by protocol-driven clinical events (e.g., extubation failure, need for intubation, physiological parameters).
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No. These are clinical studies comparing therapies, not AI assistance for human readers.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • No.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • Outcomes Data: Primary ground truths included extubation failure rates, rates of intubation/mechanical ventilation, occurrences of pneumothorax, nosocomial infection, ROP surgery, bronchopulmonary dysplasia (BPD), air leaks, IVH, NEC, sepsis, duration of respiratory support, need for surfactant, time to full feeds, length of stay, mortality, and nasal trauma scores.
    7. The sample size for the training set:

      • Not applicable.
    8. How the ground truth for the training set was established:

      • Not applicable.