510(k) Data Aggregation

    K Number
    K242209

    Validate with FDA (Live)

    Date Cleared
    2025-04-04

    (249 days)

    Product Code
    Regulation Number
    862.1775
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K242209**
    Trade/Device Name: UASure II Blood Uric Acid Monitoring System
    Regulation Number: 21 CFR 862.1775
    Monitoring System |
    | Medical Specialty | Clinical Chemistry |
    | Regulation Citation | 21 CFR 862.1775

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This UASure II Blood Uric Acid Monitoring System measures blood uric acid levels in fresh capillary whole blood drawn from fingertips. It is intended for single-patient home use by prescription and should not be shared. It is intended for self-testing outside the body (in vitro diagnostic use) by people with gout as an aid to monitor the effectiveness of uric acid control.

    The UASure II Blood Uric Acid Monitoring System helps track uric acid levels but does not diagnose Hyperuricemia or Gout. Do not change medications based on test results without talking to a doctor.

    The UASure II Blood Uric Acid Monitoring System includes the UASure II Meter, UASure II Blood Uric Acid Test Strips and UASure II Uric Acid Control Solution.

    Device Description

    The UASure II Blood Uric Acid Monitoring System consists of the UASure II Blood Uric Acid Meter, UASure II Blood Uric Acid Test Strip and UASure II Uric Acid control solution. It is used for testing of blood uric acid by self-testers at home use by prescription only. The UASure II Blood Uric Acid Test Strip and UASure II Uric Acid control solution are purchased separately.

    AI/ML Overview

    The provided FDA 510(k) clearance letter for the UASure II Blood Uric Acid Monitoring System details its intended use and general regulatory information. However, it does not contain the specific information required to describe the acceptance criteria and the study that proves the device meets those criteria in the comprehensive manner requested.

    The document only broadly states:

    • "Non-Clinical Testing: [...] results demonstrate substantial equivalence to the current methods for uric acid measurements."
    • "Clinical Testing: An accuracy study was conducted with home users using finger capillary whole blood. Results demonstrate substantial equivalence to the predicate system."
    • "Conclusion: Clinical and analytical testing demonstrated that the UASure II Blood Uric Acid Monitoring System perform in a substantially equivalent manner to that of the predicate."

    To answer your request comprehensively, information typically found in the applicant's submission (e.g., the 510(k) summary with more detailed study results, or the actual study reports) would be necessary. This includes:

    1. A table of acceptance criteria and reported device performance: This would typically involve specific statistical metrics (e.g., bias, precision, correlation coefficient, Bland-Altman agreement) and their acceptable ranges, and the actual results from the study. The document does not provide these specific numbers.
    2. Sample size used for the test set and data provenance: The document indicates "home users using finger capillary whole blood" but does not specify the number of samples or whether the data was retrospective or prospective, or the country of origin.
    3. Number of experts used to establish ground truth and qualifications: This is not applicable in this context as this is not an imaging AI device requiring expert reads, but rather a blood diagnostic device where ground truth is established by a reference method/laboratory.
    4. Adjudication method: Not applicable for this type of device. Ground truth is typically a direct measurement from a reference method.
    5. Multi Reader Multi Case (MRMC) comparative effectiveness study: Not applicable for this type of in-vitro diagnostic device. MRMC studies are specific to imaging devices often involving human interpretation.
    6. Standalone (algorithm only) performance: For this device, "standalone performance" is essentially the device's accuracy when measuring uric acid, which is compared to a reference method. The letter states "results demonstrate substantial equivalence to the predicate system" but lacks specifics.
    7. Type of ground truth used: For a blood uric acid monitoring system, the ground truth would be established by a well-calibrated, high-precision laboratory reference method for uric acid measurement. The document doesn't explicitly state what reference method was used.
    8. Sample size for the training set: This refers to the data used to develop the device/algorithm. This information is not present in the clearance letter.
    9. How ground truth for the training set was established: Similar to point 8, this information is not provided.

    In summary, based solely on the provided FDA 510(k) clearance letter, I cannot provide the detailed information requested regarding the acceptance criteria and the specific study results proving the device meets them. The letter serves as an official clearance notice, confirming substantial equivalence, but generally does not include the granular data from the performance studies.

    Ask a Question

    Ask a specific question about this device

    K Number
    K181675

    Validate with FDA (Live)

    Date Cleared
    2018-12-10

    (168 days)

    Product Code
    Regulation Number
    862.1775
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    MD6 Uric Acid Monitoring System FORA MD6 Pro Uric Acid Monitoring System Regulation Number: 21 CFR 862.1775
    meets limitations of exemptions21 CFR §862.9(c)(9) (for LFQ) |
    | Regulation Citation: | 21 CFR 862.1775

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Prescription home use: The FORA MD6 Uric Acid Monitoring System is intended for the quantitative measurement of uric acid in capillary whole blood from the fingertip. It is intended foruse outside the body (in vitro diagnostic use) by people with hyperuricemia or gout as an aid to monitor the effectiveness of uric acid control. The system is intended for single-patient home use by prescription only and should not be shared. The system should only be used with FORA MD6 Uric Acid Test Strips, and FORA Uric Acid Control Solutions.

    The system should not be used to alter hyperuricemia or gout treatment by changing any medication schedule or dosage unless specifically instructed by a healthcare professional.

    Point-of-care use: The FORA MD6 Pro Uric Acid Monitoring System is intended for the quantitative measurement of uric acid in capillary whole blood from the fingertip. This system should only be used with single-use, auto-disabling lancing devices. It is for in vitro diagnostic use only.

    This system is intended for multiple patient use by health care professionals at point of care sites as an aid to monitor the effectiveness of uric acid control in people with hyperuricemia or gout

    Device Description

    FORA MD6/ FORA MD6 Pro Uric Acid Monitoring System includes the FORA MD6/ FORA MD6 Pro Meter, the FORA MD6/ FORA MD6 Pro Uric Acid Test Strips and the Uric Acid Control Solutions.

    AI/ML Overview

    The provided text does not contain detailed acceptance criteria and the results of a study proving the device meets those criteria. It is a 510(k) summary for the FORA MD6 Uric Acid Monitoring System and FORA MD6 Pro Uric Acid Monitoring System, which states that performance studies were conducted, but it does not specify the acceptance criteria or report the detailed performance metrics from those studies.

    Therefore, I cannot provide the requested information based on the given input. The document generally states that the studies "demonstrated that the intended users can obtain uric acid results that are substantially equivalent to the current methods for uric acid measurements," but it lacks specific quantitative acceptance criteria and detailed performance data.

    Ask a Question

    Ask a specific question about this device

    K Number
    K160990

    Validate with FDA (Live)

    Date Cleared
    2017-04-11

    (368 days)

    Product Code
    Regulation Number
    862.1775
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    02454

    Re: K160990

    Trade/Device Name: Nova Max Uric Acid Monitoring System Regulation Number: 21 CFR 862.1775
    |
    | Regulation Number: | 21 CFR 862.1775

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Nova Max Uric Acid Monitoring System consists of Nova Max Uric Acid Monitor, Nova Max Uric Acid Test Strips and Nova Max Uric Acid Control Solutions. The Nova Max Uric Acid Monitoring System is intended to the quantitative measurement of Uric Acid in fresh capillary whole blood obtained from the fingertip of gout patients. It is intended for single-patient home use by prescription and should not be shared. It is intended for self-testing outside the body (in vitro diagnostic use) by people with gout as an aid to monitor the effectiveness of Uric Acid control. It is intended for use by patients undergoing treatment for gout or the order of a treating healthcare professional. This system should not be used to alter gout treatment by changing any medication schedule or dosage unless specifically instructed by a healthcare professional. This system should only be used with single-use, auto-disabling Lancing Devices. It should only be used with Nova Max Uric Acid Test Strips and Nova Max Uric Acid Control Solutions.

    Device Description

    The Nova Max Uric Acid Monitoring System uses selective mediated enzymatic action (uricase biosensor) to generate current across the electrodes. The current generated is proportional to the concentration of Uric Acid in the whole blood sample. The device, which is amperometric, measures the Uric Acid concentration in the whole blood sample by measuring the amount of current that was generated and flows through the electrodes on the Test Strips.

    The Nova Max Uric Acid Monitoring System is comprised of Nova Max Uric Acid Test Strips, a portable handheld Nova Max Uric Acid Monitor, and Nova Max Uric Acid Control Solutions.

    Monitor Power Supply: The monitor uses single (3V) lithium, non-rechargeable battery. The battery life is approximately 1,000 tests.

    No-Coding System: The user is not required to enter a Test Strip lot-specific Calibration Code into the monitor by pressing a button or by inserting a Code Key.

    Uric Acid Control Solutions are aqueous assayed solutions, containing buffered Uric Acid, preservatives, FD & C dye, and viscosity additive. They contain no products of human origin. There are three levels of controls (level 1, 2, and 3).

    Safety Lancets are provided as an accessory to the Nova Max Uric Acid Monitoring System. They are commercially available single-use, auto disabling sterilized Lancing Devices.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and study proving the device meets those criteria, based on the provided text:

    Device Name: Nova Max Uric Acid Monitoring System


    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Clinical Study Accuracy
    Linear Regression Correlation Coefficient (R²) ≥ 0.95The "Clinical Study Conclusion" states: "The results of the layperson clinical study confirmed that the Nova Max Uric Acid Monitoring System is safe and effective for the intended use populations (persons diagnosed with Gout) and the Nova Max Uric Acid Monitoring System is substantially equivalent to the predicate device." While a specific R² value isn't explicitly stated in the summary, the conclusion implies this criterion was met.
    Linear Regression Slope of 0.94 - 1.06As above, the clinical study conclusion indicates this criterion was met, even if the specific numerical result is not in the provided text.
    Bench Testing (Sample Criteria)
    Precision: Within-run CV% < 10%Reported in Table 2-1 as "Within run CV% < 10%."
    Measuring Range: 3-18 mg/dLReported in Table 2-1 as "3-18 mg/dL."
    Human Factors Study (Ease-of-Use/Comprehension)
    Subjects' ability to demonstrate understanding of system/use (successful performance of a Uric Acid whole blood capillary fingerstick test and a Uric Acid control solution test)"Conclusions were based on the subjects' ability to demonstrate by action, their understanding of the system, and their understanding of how to use the system (Successful performance of a Uric Acid whole blood capillary fingerstick test and a Uric Acid control solution test)..." The study "demonstrates ease-of-use of the device as well as effectiveness of the Nova Max Uric Acid Monitoring System instructions for use."
    Comprehension of contents of instructions for use"Conclusions were based on...comprehension of the contents of the instructions for use..." The study "demonstrates...effectiveness of the Nova Max Uric Acid Monitoring System instructions for use."
    User assessment questionnaire of ease-of-use"The response to the questionnaire indicates that the participants were comfortable with the Nova Max Uric Acid Monitoring System, and lead to the conclusion that a typical layperson diagnosed with gout will find the monitor easy to operate, and the labeling easy to understand."

    2. Sample Size Used for the Test Set and Data Provenance

    • Clinical Study Test Set:
      • Phase 1: 120 layperson subjects previously diagnosed with gout.
      • Phase 2: An additional 25 layperson subjects previously diagnosed with gout (total 145 subjects for clinical studies).
    • Human Factors Study Test Set: 120 layperson intended use subjects previously diagnosed with gout.
    • Data Provenance: The studies were conducted in the U.S. (explicitly stated for the Human Factors study, implied for the clinical study given the FDA submission). The studies were prospective, involving direct testing of subjects.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    The document does not specify the number or qualifications of experts used to establish ground truth. The ground truth was established by comparison to a legally marketed predicate device:

    • Clinical Study:
      • Phase 1: Comparison to measurements from a venous (lithium heparin) whole blood sample from the same patient by the Siemens Dimension RxL Max Clinical Chemistry System (K043546).
      • Phase 2: Comparison with venous plasma specimens measured on the URCA method on the Siemens Dimension RxL Max Clinical Chemistry System (predicate device, reference method).

    4. Adjudication Method for the Test Set

    The document does not describe any specific adjudication method for establishing ground truth from the reference methods (Siemens Dimension RxL Max Clinical Chemistry System). In this type of diagnostic device submission, the predicate device itself serves as the 'gold standard' reference, and no expert adjudication of its results would typically be required or performed beyond its own validated performance.


    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not conducted. This is an in-vitro diagnostic (IVD) device, and the performance is evaluated by comparing its quantitative measurements to a reference method, not by assessing human reader improvement with AI assistance. The "Human Factors Study" assesses user performance and comprehension, which is related to human interaction with the device, but it is not an MRMC study in the context of image interpretation or other similar diagnostic tasks.


    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Yes, the primary performance evaluation for this IVD device is its standalone performance in measuring uric acid. The "Clinical Study" directly compares the device's measured uric acid levels to those obtained by a reference method (the predicate device), demonstrating the algorithm's accuracy in producing a numerical result without direct human interpretation influencing the measurement itself (though human interaction is required for sample collection and initiation). The Human Factors study assesses the user's ability to operate the device correctly, which is a separate but critical component of the overall system's effectiveness.


    7. The Type of Ground Truth Used

    The ground truth used was comparative measurement against a validated predicate device/reference method: the Siemens Dimension RxL Max Clinical Chemistry System (K043546). This is a common approach for establishing substantial equivalence for new IVD devices.


    8. The Sample Size for the Training Set

    The document does not provide information regarding a separate "training set" or its sample size. For IVD devices like this one, studies typically focus on demonstrating performance on a test set (clinical and bench studies) rather than describing a separate training phase for an AI/ML model. The device's underlying technology is described as an "enzymatic biosensor" and amperometric measurement, implying a biochemical and electrical principle rather than a machine learning algorithm that requires extensive "training data" in the typical AI sense.


    9. How the Ground Truth for the Training Set Was Established

    Since no training set is described (as detailed in point 8), the method for establishing its ground truth is also not applicable/not provided in this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K123322

    Validate with FDA (Live)

    Date Cleared
    2013-05-21

    (207 days)

    Product Code
    Regulation Number
    862.1770
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    . § 862.1775)Product Code KNK | |
    | | Trade Name:

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ACE BUN/Urea Reagent is intended for the quantitative determination of blood urea nitrogen (BUN) concentration in serum and lithium heparin plasma using the ACE, ACE Alera, and ACE Axcel Clinical Chemistry Systems. BUN measurements are used in the diagnosis and treatment of certain renal and metabolic diseases. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    The ACE Creatinine Reagent is intended for the quantitative determination of creatinine concentration in serum and lithium heparin plasma using the ACE, ACE Alera, and ACE Axcel Clinical Chemistry Systems. Creatinine measurements are used in the diagnosis and treatment of renal diseases, in monitoring renal dialysis, and as a calculation basis for measuring other urine analytes. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    The ACE Uric Acid Reagent is intended for the quantitative determination of uric acid concentration in serum and lithium heparin plasma using the ACE, ACE Alera, and ACE Axcel Clinical Chemistry Systems. Uric acid measurements are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions and of patients receiving cytotoxic drugs. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    The ACE CK Reagent is intended for the quantitative determination of creatine kinase activity in serum and lithium heparin plasma using the ACE, ACE Alera, and ACE Axcel Clinical Chemistry Systems. Measurement of creatine kinase is used in the diagnosis and treatment of myocardial infarction and muscle diseases such as progressive, Duchenne-type muscular dystrophy. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    Device Description

    In the ACE BUN/Urea Reagent assay, urea in serum is hydrolyzed in the presence of urease to yield ammonia and carbon dioxide. The ammonia formed then reacts in the presence of glutamate dehydrogenase with 2-oxoglutarate and NADH to yield glutamate and NAD. NADH absorbs strongly at 340 nm, whereas NAD+ does not. The initial rate of decrease in absorbance, monitored bichromatically at 340 nm/647 nm, is proportional to the urea concentration in the sample.

    In the ACE Creatinine Reagent assay, creatinine reacts with picric acid in an alkaline medium to form a red-orange colored complex, which absorbs strongly at 505 nm. The rate of complex formation, determined by measuring the increase in absorbance bichromatically at 505 nm/573 nm during a fixed time interval, is directly proportional to the creatinine concentration in the sample.

    In the ACE Uric Acid Reagent assay, uric acid in serum is oxidized by uricase to allantoin and hydrogen peroxide. The hydrogen peroxide then acts to oxidatively couple dichlorohydroxybenzene sulfonic acid and 4-aminoantipyrine in a reaction catalyzed by peroxidase, producing a red colored quinoneimine complex, which absorbs strongly at 505 nm. The amount of chromogen formed is determined by measuring the increase in absorbance bichromatically at 505 nm/610 nm, and is directly proportional to the uric acid concentration in the sample.

    In the ACE CK Reagent assay, serum creatine kinase initiates the conversion of creatine phosphate to creatine with the transfer of a phosphate group to adenosine diphosphate (ADP), forming ATP. The ATP is then used in the phosphorylation of D-glucose to form D-glucose-6-phosphate and ADP. This reaction is catalyzed by hexokinase. The enzyme glucose-6-phosphate dehydrogenase catalyzes the reduction of D-glucose-6-phosphate and nicotinamide adenine dinucleotide phosphate (NADP+). The series of reactions triggered by serum creatine kinase and ending in the formation of NADPH. NADPH strongly absorbs at 340 nm, whereas NADP+ does not. Therefore, the rate of conversion of NADP+ to NADPH can be determined by monitoring the increase in absorbance bichromatically at 340 nm/378 nm. This rate of conversion from NADP+ to NADPH is a function of the activity of CK in the sample.

    AI/ML Overview

    Here's a summary of the acceptance criteria and supporting studies for the Alfa Wassermann ACE Reagents (BUN/Urea, Creatinine, Uric Acid, CK), based on the provided 510(k) summary.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implicitly derived from comparisons to a predicate device (Alfa Wassermann ACE K930104 reagents) and performance characteristics such as precision, accuracy (correlation/regression with predicate), linearity, detection limits, and interference. The reported device performance is from in-house studies and Point-of-Care (POL) studies.

    Note: The document does not explicitly state "acceptance criteria" numerical targets. Instead, it presents performance data for the candidate device, implying that the data's comparability to the predicate and established analytical standards is the basis for acceptance. I will present the reported performance, which demonstrates the device's meeting the necessary equivalency.

    CharacteristicAcceptance Criteria (Implied)Reported Device Performance (Candidate Device)
    Intended UseSame as predicate (quantitative determination in serum)BUN: Quantitative determination in serum and lithium heparin plasma. Creatinine: Quantitative determination in serum and lithium heparin plasma. Uric Acid: Quantitative determination in serum and lithium heparin plasma. CK: Quantitative determination in serum and lithium heparin plasma. (Extended to lithium heparin plasma compared to predicate, requiring performance studies in this matrix)
    PlatformsCompatible with ACE Clinical Chemistry SystemACE, ACE Alera, and ACE Axcel Clinical Chemistry Systems. (Expanded platforms compared to predicate)
    MethodPhotometric (Same as predicate)Photometric (Same as predicate)
    Calibration Stability7 days (BUN), 2 days (Creatinine), 30 days (Uric Acid)Same
    On-Board Stability30 days (BUN), 10 days (Creatinine), 30 days (Uric Acid), 25 days (CK)Same
    Sample TypeSerum (per predicate)Serum and lithium heparin plasma (Candidate device demonstrates equivalence in both)
    Sample Volume3 µL (BUN, Uric Acid), 20 µL (Creatinine), 5 µL (CK)Same
    Reaction Volume333 µL (BUN), 240 µL (Creatinine), 243 µL (Uric Acid), 170 µL (CK)Same
    Expected ValuesSame as predicateSame
    Measuring Range3-100 mg/dL (BUN), 0.33-25.0 mg/dL (Creatinine), 1.5-16.0 mg/dL (Uric Acid), 11-1350 U/L (CK)Same
    Sample StabilitySame as predicate (storage conditions)Same
    PrecisionLow, Mid, High %CV and SD comparable to predicate/clinical needsIn-House Serum/Plasma: Generally <15% CV for low, <5% CV for mid/high. (See pages 6-7, specific values listed). POL: Generally <10% CV for low, <5% CV for mid/high. (See pages 10-13, specific values listed).
    Matrix ComparisonSerum vs. Lithium Heparin Plasma: Slope, Intercept, Correlation (R) and Std Error Est. demonstrating equivalence (e.g., R > 0.98, Slope ~1, Intercept ~0)BUN: R > 0.99, Slope 0.979-1.009, Intercept -0.1 to 0.4. Creatinine: R > 0.99, Slope 1.003-1.050, Intercept -0.077 to 0.005. Uric Acid: R > 0.98, Slope 1.008-1.028, Intercept -0.29 to -0.09. CK: R > 0.99, Slope 0.978-1.006, Intercept -0.5 to 0.1. (See pages 8-9)
    Method Comparison (POL)Comparison to In-House ACE results: Slope, Intercept, Correlation (R) and Std Error Est. demonstrating equivalence to predicate system (e.g., R > 0.98, Slope ~1, Intercept ~0).BUN: R > 0.99, Slope 0.989-1.039, Intercept -0.1 to 1.4. Creatinine: R > 0.99, Slope 0.977-1.051, Intercept -0.085 to 0.037. Uric Acid: R > 0.99, Slope 0.936-1.034, Intercept 0.02 to 0.58. CK: R > 0.99, Slope 0.962-1.053, Intercept -16.5 to 1.1. (See pages 14-15)
    Detection Limits (LoB, LoD, LoQ)Low values demonstrating capability to measure analytes at clinically relevant low concentrations.BUN: LoB 1.53, LoD 1.97, LoQ 3.0 mg/dL. Creatinine: LoB 0.14, LoD 0.18, LoQ 0.33 mg/dL. Uric Acid: LoB 1.11, LoD 1.34, LoQ 1.50 mg/dL. CK: LoB 4.68, LoD 8.30, LoQ 11.0 U/L. (See page 16)
    LinearityWide linear range covering clinical needs, with high correlation.BUN: Linear to 100.0 mg/dL, R² 0.9991. Creatinine: Linear to 25.0 mg/dL, R² 0.9981. Uric Acid: Linear to 16.0 mg/dL, R² 0.9939. CK: Linear to 1350.0 U/L, R² 0.9975. (See page 16)
    InterferencesNo significant interference at specified levels of common interferents.Demonstrated no significant interference from icterus, hemolysis, lipemia/triglycerides, and ascorbic acid at clinically relevant concentrations for all four analytes. (See page 17)

    Studies Proving Acceptance Criteria:

    The studies are described under "Performance Data" and "Device Comparison with Predicate" sections of the 510(k) summary. These studies aim to demonstrate substantial equivalence to the previously cleared predicate device (Alfa Wassermann ACE BUN/Urea Reagent, ACE Creatinine Reagent, ACE Uric Acid Reagent, and ACE CK Reagents, K930104).

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set (Matrix Comparison: Serum vs. Plasma):

      • BUN: 95 pairs (ACE), 96 pairs (Alera), 51 pairs (Axcel)
      • Creatinine: 102 pairs (ACE), 102 pairs (Alera), 55 pairs (Axcel)
      • Uric Acid: 97 pairs (ACE), 95 pairs (Alera), 55 pairs (Axcel)
      • CK: 94 pairs (ACE), 96 pairs (Alera), 55 pairs (Axcel)
      • Data Provenance: The document states "In-House Precision" and "In-House Matrix Comparison". This typically implies that the data was generated within the manufacturer's laboratory or a testing facility under their control. The country of origin is not explicitly stated but is implicitly the US, given the 510(k) submission to the FDA. The data is retrospective, as it's being used to characterize reagent performance.
    • Test Set (POL - Method Comparison):

      • BUN: 53-54 samples per POL lab for comparison with In-House ACE.
      • Creatinine: 51 samples per POL lab for comparison with In-House ACE.
      • Uric Acid: 49 samples per POL lab for comparison with In-House ACE.
      • Creatinine Kinase: 48-50 samples per POL lab for comparison with In-House ACE.
      • Data Provenance: "POL - Method Comparison" indicates data from Physician Office Laboratories (POLs), likely external to the main testing facility but still considered part of the overall validation. The document refers to "In-House ACE (x) vs. POL 1 ACE (y)", "POL 2 ACE (y)", etc., indicating comparisons against internal reference methods. The data is retrospective.
    • Test Set (Detection Limits, Linearity, Interferences, Alera Precision): The sample sizes for these specific studies are not explicitly detailed in the provided summary beyond "Low level tested," "Upper level tested," and "number of replicates for precision measurements (i.e. '3.2, 4.0%') implies multiple measurements. These are likely in-house, retrospective studies.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    This information is not provided in the document. For in vitro diagnostic devices like these reagents, the "ground truth" is typically established by reference methods or validated comparative methods, often run on established clinical chemistry analyzers. The expertise lies in operating these reference instruments and ensuring proper laboratory practices, rather than expert interpretation of images or clinical cases.

    4. Adjudication Method for the Test Set

    This concept is not applicable to this type of device. Adjudication methods (like 2+1, 3+1) are common in studies involving subjective interpretations (e.g., medical image analysis by radiologists) where discrepancies among readers need to be resolved to establish ground truth. For quantitative IVD reagents, the reference method provides a direct numerical result, not a subjective interpretation requiring adjudication.

    5. Multi Reader Multi Case (MRMC) Comparative Effectiveness Study

    This is not applicable to this type of device. MRMC studies are used to assess the effectiveness of an AI system (or any diagnostic aid) for human readers, particularly in medical imaging. The current device is a diagnostic reagent, which directly measures chemical concentrations, not an AI intended to assist human interpretation of cases.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    This is not applicable in the context of an IVD reagent. The "algorithm" here is the chemical reaction and photometric measurement itself. The performance data presented (precision, linearity, method comparison, etc.) is the standalone performance of the reagent on the specified analyzers, without human interpretive input altering the result.

    7. Type of Ground Truth Used

    The ground truth for all performance studies (precision, matrix comparison, method comparison, linearity) is established by comparison against a reference method or a substantially equivalent predicate method performed on existing, validated clinical chemistry analyzers (specifically, the predicate ACE Clinical Chemistry System and the candidate ACE, ACE Alera, and ACE Axcel systems themselves acting as the "reference" for their own performance claims, and for method comparisons, the "In-House ACE" results). This is a common and accepted approach for demonstrating substantial equivalence for IVD reagents.

    8. Sample Size for the Training Set

    This information is not provided and is generally not applicable in the way it is asked for AI/ML devices. These are chemical reagents, not AI/ML algorithms that require "training sets" in the conventional sense of machine learning. The development process would involve formulation, optimization, and internal testing to define assay parameters, which is a different concept than an AI training set.

    9. How the Ground Truth for the Training Set Was Established

    As stated above, the concept of a "training set" with established ground truth in the AI/ML sense is not applicable to these chemical reagents. The "ground truth" during their development and optimization would be based on established analytical chemistry principles and performance measurements against known standards or reference materials.

    Ask a Question

    Ask a specific question about this device

    K Number
    K113389

    Validate with FDA (Live)

    Date Cleared
    2012-08-10

    (268 days)

    Product Code
    Regulation Number
    862.1770
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    . § 862.1775)Product Code KNK |
    | | Trade

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ACE BUN/Urea Reagent is intended for the quantitative determination of blood urea nitrogen (BUN) concentration in serum using the ACE Axcel Clinical Chemistry System. BUN measurements are used in the diagnosis and treatment of certain renal and metabolic diseases. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    The ACE Creatinine Reagent is intended for the quantitative determination of creatinine concentration in serum using the ACE Axcel Clinical Chemistry System. Creatinine measurements are used in the diagnosis and treatment of renal diseases, in monitoring renal dialysis, and as a calculation basis for measuring other urine analytes. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    The ACE Uric Acid Reagent is intended for the quantitative determination of uric acid concentration in serum using the ACE Axcel Clinical Chemistry System. Uric acid measurements are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions and of patients receiving cytotoxic drugs. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    The ACE CK Reagent is intended for the quantitative determination of creatine kinase activity in serum using the ACE Axcel Clinical Chemistry System. Measurement of creatine kinase is used in the diagnosis and treatment of myocardial infarction and muscle diseases such as progressive, Duchenne-type muscular dystrophy. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    Device Description

    The ACE Axcel Clinical Chemistry System consists of two major components, the chemistry instrument and an integrated Panel PC. The instrument accepts the physical patient samples, performs the appropriate optical or potentiometric measurements on those samples and communicates that data to an integral Panel PC. The Panel PC uses keyboard or touch screen input to manually enter a variety of data, control and accept data from the instrument, manage and maintain system information and generate reports relative to patient status and instrument performance. The Panel PC also allows remote download of patient requisitions and upload of patient results via a standard interface.

    In the ACE BUN/Urea Reagent assay, urea in serum is hydrolyzed to yield ammonia and carbon dioxide in the presence of urease. The ammonia formed then reacts with 2-oxoglutarate and NADH in the presence of glutamate dehydrogenase to yield glutamate and NAD. Two moles of NADH are oxidized for each mole of urea present. NADH absorbs strongly at 340 nm, whereas NAD+ does not. The initial rate of decrease in absorbance, monitored bichromatically at 340 nm/647 nm, is proportional to the urea concentration in the sample.

    In the ACE Creatinine Reagent assay, creatinine reacts with picric acid in an alkaline medium to form a red-orange colored complex, which absorbs strongly at 505 nm. The rate of complex formation, determined by measuring the increase in absorbance bichromatically at 505 nm/573 nm during a fixed time interval, is directly proportional to the creatinine concentration in the sample.

    In the ACE Uric Acid Reagent assay, uric acid in serum is oxidized by uricase to allantoin and hydrogen peroxide. The hydrogen peroxide then acts to oxdatively couple dichlorohydroxybenzene sulfonic acid and 4-aminoantipyrine in a reaction catalyzed by peroxidase, producing a red colored quinoneimine complex, which absorbs strongly at 505 nm. The amount of chromogen formed, determined by measuring the increase in absorbance bichromatically at 505 nm/610 nm, is directly proportional to the uric acid concentration in the sample.

    In the ACE CK Reagent assay, serum creatine kinase initiates the conversion of creatine phosphate to creatine with the transfer of a phosphate group to adenosine diphosphate (ADP), forming ATP. The ATP is then used in the phosphorylation of D-glucose to form D-glucose-6-phosphate and ADP. This reaction is catalyzed by hexokinase. The enzyme glucose-6-phosphate dehydrogenase catalyzes the reduction of D-glucose-6-phosphate and nicotinamide adenine dinucleotide phosphate (NADP+). The series of reactions triggered by serum creatine kinase and ending in the formation of NADPH. NADPH strongly absorbs at 340 nm, whereas NADP+ does not. Therefore, the rate of conversion of NADP+ to NADPH can be determined by monitoring the increase in absorbance bichromatically at 340 nm/378 nm. This rate of conversion from NADP+ to NADPH is a function of the activity of CK in the sample.

    The ACE BUN/Urea Reagent consists of a single reagent bottle. The reagent contains alpha-ketoglutarate, urease, glutamate dehydrogenase, adenosine diphosphate (ADP), nicotinamide adenine dinucleotide and reduced (NADH).

    The ACE Creatinine Reagent consists of two reagent bottles (Sodium Hydroxide Reagent and Picric Acid Reagent). The Sodium Hydroxide Reagent (R1) contains sodium hydroxide. The Picric Acid Reagent (R2) contains picric Acid.

    The ACE Uric Acid Reagent consists of a single reagent bottle. The reagent contains 4-aminoantipyrine, dichlorohydroxybenzene sulfonic acid, peroxidase and uricase.

    The ACE CK Reagent consists of two reagent bottles (Buffer and Substrate). The Buffer Reagent (R1) contains: imidazole buffer, glucose, N-acetyl-cysteine, magnesium acetate, EDTA, NADP and hexokinase. The Substrate Reagent (R2) contains: creatine phosphate, ADP, AMP, diadenosine pentaphosphate, EDTA and glucose-6-phosphate dehydrogenase.

    AI/ML Overview

    This 510(k) summary describes the analytical performance of the Alfa Wassermann ACE BUN, Creatinine, Uric Acid, and CK Reagents when used with the ACE Axcel Clinical Chemistry System. The study aims to demonstrate substantial equivalence to a predicate device by evaluating precision, accuracy, and detection limits.

    1. Table of Acceptance Criteria (Implied) and Reported Device Performance

    The acceptance criteria for this type of device are generally understood to be that the performance of the new device (ACE Axcel System with new reagents) should be comparable to or better than a legally marketed predicate device (Alfa Wassermann ACE Clinical Chemistry System). While explicit numerical acceptance criteria are not strictly stated as "acceptance criteria" but rather as "reported performance," the goal is to show the device performs within acceptable analytical limits for clinical chemistry assays and is strongly correlated with the predicate.

    Reagent (Analyte)Performance MetricImplied Acceptance Criteria (Comparison to Predicate)Reported Device Performance (ACE Axcel vs. ACE Clinical Chemistry System)
    ACE BUN/UreaPrecision (Within-run CV)< 5% (typical clinical chemistry expectation)1.1% to 3.3% (lab), 0.0% to 2.6% (POL)
    Precision (Total CV)< 10% (typical clinical chemistry expectation)3.5% to 4.6% (lab), 3.0% to 5.2% (POL)
    Accuracy (Correlation Coeff.)R > 0.975 (strong correlation)0.9963 (lab), 0.9982 to 0.9988 (POL)
    Accuracy (Slope CI)Close to 1 (e.g., 0.95-1.05)0.995 to 1.028 (lab), 0.983 to 1.039 (POL)
    Accuracy (Intercept CI)Close to 0 (e.g., -5 to 5)-0.3 to 0.6 (lab), -0.7 to 1.6 (POL)
    Detection LimitClinically relevant low level1.1 mg/dL
    ACE CreatininePrecision (Within-run CV)< 10% (typical clinical chemistry expectation)1.3% to 9.6% (lab), 0.9% to 5.1% (POL)
    Precision (Total CV)< 15% (typical clinical chemistry expectation, higher for very low values)2.7% to 9.8% (lab), 2.1% to 6.1% (POL)
    Accuracy (Correlation Coeff.)R > 0.975 (strong correlation)0.9998 (lab), 0.9994 to 0.9998 (POL)
    Accuracy (Slope CI)Close to 1 (e.g., 0.95-1.05)0.975 to 0.983 (lab), 0.961 to 1.027 (POL)
    Accuracy (Intercept CI)Close to 0 (e.g., -0.1 to 0.1)-0.022 to 0.010 (lab), -0.136 to 0.001 (POL)
    Detection LimitClinically relevant low level0.19 mg/dL
    ACE Uric AcidPrecision (Within-run CV)< 5% (typical clinical chemistry expectation)1.8% to 4.9% (lab), 1.5% to 4.4% (POL)
    Precision (Total CV)< 10% (typical clinical chemistry expectation)2.0% to 5.4% (lab), 1.8% to 5.2% (POL)
    Accuracy (Correlation Coeff.)R > 0.975 (strong correlation)0.9958 (lab), 0.9858 to 0.9961 (POL)
    Accuracy (Slope CI)Close to 1 (e.g., 0.95-1.05)1.023 to 1.060 (lab), 0.972 to 1.054 (POL)
    Accuracy (Intercept CI)Close to 0 (e.g., -0.5 to 0.5)-0.18 to 0.07 (lab), -0.31 to 0.28 (POL)
    Detection LimitClinically relevant low level1.13 mg/dL

    Note: Acceptance criteria are implied based on typical expectations for clinical chemistry assays and the intent to demonstrate substantial equivalence to a predicate device. Specific numerical targets for acceptance were not explicitly stated in the provided text, but the strong correlation and low CVs indicate meeting such criteria.

    2. Sample Sizes Used for the Test Set and Data Provenance

    • ACE BUN/Urea Reagent:

      • Accuracy (Correlation Study): 113 samples (clinical laboratory), and patient correlation studies at three Physician Office Laboratory (POL) sites (number of samples not explicitly stated for POL, but implied to be sufficient for regression analysis).
      • Precision: Four BUN levels over 22 days (laboratory study), and three POL sites over 5 days (levels not specified for POL).
      • Data Provenance: Not explicitly stated, but clinical laboratory and Physician Office Laboratory (POL) settings are mentioned, suggesting human serum samples. Whether these were retrospective or prospective is not specified, but typically, method comparison studies use prospective or collected retrospective clinical samples.
    • ACE Creatinine Reagent:

      • Accuracy (Correlation Study): 136 samples (clinical laboratory), and patient correlation studies at three POL sites (number of samples not explicitly stated for POL).
      • Precision: Four creatinine levels over 22 days (laboratory study), and three POL sites over 5 days (levels not specified for POL).
      • Data Provenance: Not explicitly stated, but clinical laboratory and POL settings are mentioned, suggesting human serum samples.
    • ACE Uric Acid Reagent:

      • Accuracy (Correlation Study): 106 samples (clinical laboratory), and patient correlation studies at three POL sites (number of samples not explicitly stated for POL).
      • Precision: Four uric acid levels over 22 days (laboratory study), and three POL sites over 5 days (levels not specified for POL).
      • Data Provenance: Not explicitly stated, but clinical laboratory and POL settings are mentioned, suggesting human serum samples.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    Not applicable. This is an in vitro diagnostic (IVD) device for quantitative measurement of chemical analytes (BUN, Creatinine, Uric Acid, CK) in serum. The 'ground truth' for such devices is established by a reference method or a legally marketed predicate device, not by expert interpretation of images or clinical findings.

    4. Adjudication Method for the Test Set

    Not applicable. As noted above, this is an IVD device for quantitative chemical analysis. Adjudication methods are typically used for qualitative or interpretive diagnostic devices where human expert disagreement might occur (e.g., radiology, pathology). Here, the comparison is directly numerical between the candidate device and the predicate device.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size of How Much Human Readers Improve with AI vs. Without AI Assistance

    Not applicable. This is an IVD device for laboratory chemical analysis, not an imaging or interpretive diagnostic device that involves human readers or AI assistance in interpretation.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Yes, in a sense. The described studies evaluate the performance of the algorithm/system only (the ACE Axcel Clinical Chemistry System with the new reagents) in quantifying the analytes in serum. The performance data (precision, accuracy, detection limit) are intrinsic to the device's analytical capability, independent of human interpretation of the results for the purpose of generating the values themselves. While trained personnel operate the system, the analytical performance is measured as a standalone function of the device.

    7. The Type of Ground Truth Used

    The "ground truth" for the accuracy studies was established by comparing the results from the Alfa Wassermann ACE Axcel Clinical Chemistry System (the new device, 'y') to a legally marketed predicate device, the Alfa Wassermann ACE Clinical Chemistry System ('x'). This is a common method for IVD substantial equivalence, where the predicate is considered the accepted reference for performance. For detection limits, it would typically involve analyzing samples with known, very low concentrations of the analytes or diluting higher concentration samples to determine the lowest measurable level.

    8. The Sample Size for the Training Set

    The provided text describes performance validation studies, not the development or training of an algorithm in the machine learning sense. Therefore, there is no "training set" for an algorithm to learn from in this context. The study focuses on verifying the performance of the already-developed reagent and instrument system.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no "training set" in the machine learning sense for this type of IVD device submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K100263

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2011-05-06

    (463 days)

    Product Code
    Regulation Number
    862.1580
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Systems URIC ACID MONO SLUric acid, "URIC ACID MONO SL"Class IUric acid test system (Sec.862.1775

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ELITech Clinical Systems PHOSPHORUS reagent is for the quantitative in vitro diagnostic determination of inorganic phosphorus in human serum and plasma on the Vital Scientific Selectra/Flexor analyzers. It is not intended for use in Point of Care settings. Measurements of phosphorus (inorganic) are used in the diagnosis and treatment of various disorders, including parathyroid gland and kidney diseases, and vitamin D imbalance.

    ELITech Clinical Systems URIC ACID MONO SL reagent is for the quantitative in vitro diagnostic determination of uric acid in human serum and plasma on the Vital Scientific Selectra/Flexor analyzers. It is not intended for use in Point of Care settings. Measurements obtained by this device are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and of patients receiving cytotoxic drugs.

    ELITech Clinical Systems UREA UV SL reagent is for the quantitative in vitro diagnostic determination of urea nitrogen in human serum and plasma on the Vital Scientific Selectra/Flexor analyzers. It is not intended for use in Point of Care settings. Measurements obtained by this device are used in the diagnosis and treatment of certain renal and metabolic diseases.

    ELITech Clinical Systems ELICAL 2 is a multi-parametric calibrator for in vitro diagnostic use in the calibration of quantitative ELITech Clinical Systems methods on the Vital Scientific Selectra Junior Analyzer and the Vital Scientific Flexor Junior Analyzer.

    ELITech Clinical Systems ELITROL I is a multi-parametric control serum for in vitro diagnostic use in accuracy control of quantitative ELITech Clinical Systems methods on the Vital Scientific Selectra Junior Analyzer and the Vital Scientific Flexor Junior Analyzer. ELITech Clinical Systems ELITROL II is a multi-parametric control serum for in vitro diagnostic use in accuracy control of quantitative ELITech Clinical Systems methods on the Vital Scientific Selectra Junior analyzer and the Vital Scientific Flexor Junior analyzers.

    Device Description

    ELITech Clinical Systems ELICAL 2 is a lyophilized calibrator based on human serum containing constituents to ensure optimal calibration. ELICAL 2 is prepared exclusively from the blood of donors tested individually and found to be negative for HbsAg and to antibodies to HCV and HIV according to FDA-approved methods or methods in compliance with the European Directive 98/79/EC, Annex II, List A.

    The device for this submission is available as kit only. It consists of 2 reagents: Reagent 1 contains Tris buffer (pH 7.60), Adenosine diphosphate potassium salt (ADP), alpha-Ketoglutarate, Urease (jack bean), Glutamate dehydrogenase (GIDH) (bovine liver) and sodium azide. Reagent 2 contains NADH and sodium azide

    The device for this submission is available as kit only. It consists of 1 reagent R. Reagent R consists of sulfuric acid and ammonium molybdate.

    The device for this submission is available as kit only. It consists of 1 reagent R. Reagent R consists of Phosphate buffer (pH 7.0), N-Ethyl-N-(2-Hydroxy-3-Sulfopropyl) m-Toluidine (EHSPT), Ferrocyanide, Amino-4-antipyrine (4-AAP), Uricase (microorganisms), Peroxidase (horseradich) and sodium azide.

    ELITech Clinical Systems ELITROL I and ELITROL II are two level quality control products consisting of lyophilized human serum containing constituents at desired levels. Elitrol I and Elitrol II are prepared exclusively from the blood of donors tested individually and found to be negative for HbsAg and to antibodies to HCV and HIV according to FDA-approved methods or methods in compliance with the European Directive 98/79/EC, Annex II, List A.

    AI/ML Overview

    The provided text describes several in vitro diagnostic (IVD) devices: ELITech Clinical Systems ELICAL 2 (calibrator), ELITech Clinical Systems UREA UV SL (reagent), ELITech Clinical Systems PHOSPHORUS (reagent), ELITech Clinical Systems URIC ACID MONO SL (reagent), and ELITech Clinical Systems ELITROL I and ELITROL II (controls).

    The studies performed for these devices are primarily method comparison and precision studies, focusing on demonstrating substantial equivalence to predicate devices rather than proving a specific clinical utility through a multi-reader multi-case study or a standalone algorithm performance study.

    Here's an analysis based on your requested information:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implicitly defined by demonstrating equivalence to the predicate devices. The performance metrics presented are directly compared.

    For ELITech Clinical Systems UREA UV SL (K100263):

    Performance MetricAcceptance Criteria (Predicate: ABX PENTRA UREA CP)Reported Device Performance (ELITech Clinical Systems UREA UV SL)
    Measuring Range1.03 to 140.3 mg/dL (Automatic post-dilution: 701.5 mg/dL)4.7 to 140.0 mg/dL (Extended measuring range: 140.0 to 670.0 mg/dL)
    Limit of Detection (LoD)Not explicitly stated0.3 mg/dL
    Limit of Quantification (LoQ)0.9 mg/dL2.3 mg/dL
    Precision
    Within Run (Level 7.3 mg/dL)2.27% (for 18.7 mg/dL)CV=2.1%
    Within Run (Level 29.2 mg/dL)1.66% (for 72.8 mg/dL)CV=0.8%
    Within Run (Level 72.4 mg/dL)2.76% (for 6.0 mg/dL) etc.CV=0.7%
    Total (Level 7.3 mg/dL)2.14% (for 18.5 mg/dL)CV=2.8%
    Total (Level 29.2 mg/dL)1.93% (for 71.7 mg/dL)CV=1.3%
    Total (Level 72.4 mg/dL)2.14% (for 19.2 mg/dL) etc.CV=1.6%
    Method Comparisony=0.99 x - 0.06 mg/dL, r²=0.996, range: 1.03 to 138.89 mg/dLy=0.991 x + 0.6 mg/dL, r=0.999, range: 4.4 to 139.8 mg/dL
    Interference (Hemoglobin)No significant influence up to 460 mg/dLNo significant interference up to 500 mg/dL
    Interference (Triglycerides)No significant influence up to 612.5 mg/dLNo significant interference up to 614 mg/dL triglyceride equivalent
    Interference (Total Bilirubin)No significant influence up to 22.23 mg/dLNo significant interference up to 30 mg/dL (unconjugated) / 29.5 mg/dL (conjugated)
    Calibration Frequency8 days7 days
    On-board Stability70 days14 days

    For ELITech Clinical Systems PHOSPHORUS (K100263):

    Performance MetricAcceptance Criteria (Predicate: ABX PENTRA PHOSPHORUS CP)Reported Device Performance (ELITech Clinical Systems PHOSPHORUS)
    Measuring Range0.30 to 24.18 mg/dL (Automatic post-dilution: 96.72 mg/dL)2.0 to 20.0 mg/dL
    Limit of Detection (LoD)0.28 mg/dL0.02 mg/dL
    Limit of Quantification (LoQ)Not explicitly stated1.00 mg/dL
    Precision
    Within Run (Level 2.37 mg/dL)1.25% (for 4.08 mg/dL)CV=1.1%
    Within Run (Level 4.80 mg/dL)0.77% (for 6.34 mg/dL)CV=1.5%
    Within Run (Level 9.55 mg/dL)2.48% (for 2.39 mg/dL) etc.CV=1.7%
    Total (Level 2.37 mg/dL)2.50% (for 4.01 mg/dL)CV=1.9%
    Total (Level 4.80 mg/dL)1.82% (for 6.35 mg/dL)CV=1.7%
    Total (Level 9.55 mg/dL)3.56% (for 2.50 mg/dL) etc.CV=2.2%
    Method Comparisony=1.04x + 0.15 mg/dL, r²=0.998, range: 0.30 to 24.08 mg/dLy=0.999 - 0.09 mg/dL, r=0.999, range: 2.02 to 20.08 mg/dL
    Interference (Hemoglobin)No significant influence up to 125 mg/dLNo significant interference up to 50 mg/dL
    Interference (Triglycerides)No significant influence up to 262.5 mg/dLNo significant interference up to 732 mg/dL
    Interference (Total Bilirubin)No significant influence up to 6 mg/dLNo significant interference up to 15 mg/dL (unconjugated) / 1.5 mg/dL (conjugated)
    Calibration Frequency34 days28 days
    On-board Stability70 days28 days

    For ELITech Clinical Systems URIC ACID MONO SL (K100263):

    Performance MetricAcceptance Criteria (Predicate: ABX PENTRA URIC ACID CP)Reported Device Performance (ELITech Clinical Systems URIC ACID MONO SL)
    Measuring Range0.18 to 25.00 mg/dL (Automatic post-dilution: 75.00 mg/dL)1.5 to 25.0 mg/dL (Extended measuring range: 25 to 78 mg/dL)
    Limit of Detection (LoD)0.19 mg/dL0.02 mg/dL
    Limit of Quantification (LoQ)Not explicitly stated0.50 mg/dL
    Precision
    Within Run (Level 2.49 mg/dL)0.45% (for 4.62 mg/dL)CV=0.8%
    Within Run (Level 5.19 mg/dL)0.34% (for 11.63 mg/dL)CV=1.3%
    Within Run (Level 7.63 mg/dL)1.24% (for 2.53 mg/dL) etc.CV=1.1%
    Total (Level 2.49 mg/dL)2.81% (for 4.64 mg/dL)CV=2.6%
    Total (Level 5.19 mg/dL)1.39% (for 11.73 mg/dL)CV=2.0%
    Total (Level 7.63 mg/dL)2.64% (for 4.67 mg/dL) etc.CV=2.1%
    Method Comparisony=0.95 x + 0.09 mg/dL, r²=0.996, range: 0.18 to 23.59 mg/dLy=1.015 x + 0.03 mg/dL, r=0.999, range: 1.49 to 24.40 mg/dL
    Interference (Hemoglobin)No significant influence up to 500 mg/dLNo significant interference up to 50 mg/dL
    Interference (Triglycerides)No significant influence up to 612.5 mg/dLNo significant interference up to 1070 mg/dL
    Interference (Total Bilirubin)No significant influence up to 36 mg/dLNo significant interference up to 30 mg/dL (unconjugated) / 14.8 mg/dL (conjugated)
    Calibration Frequency15 days28 days
    On-board Stability41 days28 days

    2. Sample size used for the test set and the data provenance

    • UREA UV SL: The method comparison study gives a range of 4.4 to 139.8 mg/dL for the device. The R-value of 0.999 implies a good correlation across the study range. While a specific number of samples isn't explicitly stated, the R-value is usually calculated from a sufficiently large set of patient samples spanning the analytical range. The data provenance is not stated (e.g., country of origin, retrospective/prospective), but it is implied to be clinical samples used for method comparison.
    • PHOSPHORUS: The method comparison study gives a range of 2.02 to 20.08 mg/dL for the device. The R-value of 0.999 implies a good correlation. Similar to UREA UV SL, the number of samples is not explicitly stated, and data provenance is not provided but implied to be clinical samples.
    • URIC ACID MONO SL: The method comparison study gives a range of 1.49 to 24.40 mg/dL for the device. The R-value of 0.999 implies a good correlation. The number of samples is not explicitly stated, and data provenance is not provided but implied to be clinical samples.

    For ELICAL 2, ELITROL I, ELITROL II: These are calibrators and controls; their performance is validated through stability studies and their intended use in calibrating and controlling assays. No "test set" in the sense of patient samples for diagnostic performance is applicable here. The device description for ELICAL 2, ELITROL I, and ELITROL II mentions they are "prepared exclusively from the blood of donors tested individually and found to be negative for HbsAg and to antibodies to HCV and HIV according to FDA-approved methods or methods in compliance with the European Directive 98/79/EC, Annex II, List A." This suggests human-derived materials.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. These are in vitro diagnostic devices for quantitative measurements, not imaging or subjective diagnostic interpretations requiring expert consensus for ground truth. "Ground truth" in this context refers to the measured values obtained by the predicate device or a reference method for the method comparison studies.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not applicable. This is not a study involving human interpretation or adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is an in vitro diagnostic device, not an AI-assisted diagnostic tool requiring human reader studies.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    This is an IVD reagent and calibrator kit, not an algorithm. The performance data presented (e.g., precision, method comparison, LoD, LoQ) represents the "standalone" analytical performance of the device on the specified analyzer (Selectra Junior/Flexor Junior).

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth for the method comparison studies is the quantitative result obtained from the predicate device (ABX PENTRA UREA CP, ABX PENTRA PHOSPHORUS CP, ABX PENTRA URIC ACID CP) or a reference method assumed to be the "truth" for those studies. For precision studies, there isn't an external "ground truth" but rather a measure of the device's own reproducibility.

    8. The sample size for the training set

    Not applicable. These are traditional IVD reagents and calibrators, not machine learning algorithms that require a "training set."

    9. How the ground truth for the training set was established

    Not applicable. As above, no training set for a machine learning algorithm is involved.

    Ask a Question

    Ask a specific question about this device

    K Number
    K102568

    Validate with FDA (Live)

    Date Cleared
    2011-05-06

    (241 days)

    Product Code
    Regulation Number
    862.1775
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Trade Name: Architect Uric Acid Common Name: Uric Acid Governing Regulation: 862.1775 Device Classification
    Drive Irving,TX 75038-4313

    Re: K102568 Trade Name: ARCHITECT Uric Acid Assay Regulation Number: CFR 862.1775

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ARCHITECT Uric Acid test system is a device intended to measure uric acid in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and of patients receiving cytotoxic drugs.

    Device Description

    The Uric Acid assay is an in vitro diagnostic assay for use on the ARCHITECT c8000 System for the quantitative determination of uric acid in human serum, plasma, or urine using a uricase methodology. The Uric Acid assay is a two-part reaction. Uric acid is oxidized to allantoin by uricase with the production of hydrogen peroxide (H2O2). The H2O2 reacts with 4-aminoantipyrine (4-AAP) and N-(3-sulfopropyl)-3-methoxy-5methylanaline (HMMPS) in the presence of peroxidase (POD) to yield a quinoneimine dye. The resulting change in absorbance at 604 nm is proportional to the uric acid concentration in the sample.

    The two-part (R1/R2) configuration of this assay allows reduction of interference from ascorbic acid by inclusion of ascorbic oxidase in the R1 portion of the assay.

    AI/ML Overview

    The provided text describes a medical device, the Architect Uric Acid assay, which is used for the quantitative determination of uric acid in human serum, plasma, or urine. The information focuses on its intended use, technological characteristics, and substantial equivalence to a previously marketed device (Abbott On-Market Uric Acid assay).

    However, the provided text does not contain the specific details required to complete your request, such as a table of acceptance criteria, reported performance, sample sizes for test and training sets, expert qualifications for ground truth, adjudication methods, or results of MRMC or standalone studies.

    The text emphasizes that the new device is "substantially equivalent" to the predicate device, implying that its performance is expected to be similar, but it does not present the specific acceptance criteria or the study data proving that it meets those criteria. The FDA letter confirms the device's substantial equivalence but also does not include the detailed performance data.

    Therefore, I cannot fully answer your request based on the provided input.

    If such information were available in the text, it would typically appear in a section detailing specific performance studies (e.g., precision, accuracy, linearity, interference studies) and their results, often compared against predefined acceptance limits.

    Ask a Question

    Ask a specific question about this device

    K Number
    K081276

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2008-09-12

    (130 days)

    Product Code
    Regulation Number
    862.1345
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    | Device Class | Class I |
    | Classification Name: | §862.1775

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ABX PENTRA Glucose HK CP reagent with associated calibrators and controls are intended for use on ABX PENTRA 400 for quantitative in vitro diagnostic determination of glucose in human serum, plasma and urine using glucose hexokinase method by colorimetry. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.

    ABX PENTRA Uric Acid CP reagent with associated calibrators and controls are intended for use on ABX PENTRA 400 for quantitative in vitro diagnostic determination of uric acid in human serum, plasma and urine based on the enzymatic determination of uric acid using a chromogenic system in the presence of peroxidase and uricase (Trinder method). Measurements obtained by this device are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and of patients receiving cytotoxic drugs.

    ABX PENTRA Urine Control L/H is for use in quality control by monitoring accuracy and precision.

    Device Description

    All the reagents, controls and calibrators included in this submission are for use on the ABX PENTRA 400 (K052007), which is a discrete photometric bench top clinical chemistry analyzer.

    The ABX PENTRA Glucose HK CP is an in vitro diagnostic assay for the quantitative determination of glucose in human serum, plasma and urine based on an enzymatic method using hexokinase coupled with glucose-6-phosphate dehydrogenase. It is composed of a bi-reagent cassette, with 56 ml and 14 ml compartments. Reagents are chemical solutions with additives.

    The ABX PENTRA Uric Acid CP is an in vitro diagnostic assay for the quantitative determination of uric acid in human serum, plasma and urine based on the enzymatic determination of uric acid using a chromogenic system in the presence of peroxidase and uricase (Trinder method). It is composed of a bi-reagent cassette, with 60 ml and 15 ml compartments. Reagents are chemical solutions with additives.

    The ABX PENTRA Urine Control L/H is a two-level (Low and High) quality control consisting of liquid solutions prepared from human urine with chemical additives and materials of biological origin added as required to obtain given component levels. The assigned values of the control components are given in the enclosed annex, ensuring control of the appropriate HORIBA ABX methods on the ABX PENTRA 400 analyzer. Each control level is provided in one vial of 10 ml.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the ABX PENTRA Glucose HK CP and ABX PENTRA Uric Acid CP, focusing on the added urine sample performance. The ABX PENTRA Urine Control L/H is simply a control for these assays and its performance is described in terms of stability, not analytical performance.

    1. Table of Acceptance Criteria and Reported Device Performance

    Performance MetricAcceptance Criteria (Implied)Reported Device Performance (ABX PENTRA Glucose HK CP - Urine)Reported Device Performance (ABX PENTRA Uric Acid CP - Urine)
    Limit of BlankNot explicitly stated1.95 mg/dl2.33 mg/dl
    Limit of DetectionNot explicitly stated2.9 mg/dl3.49 mg/dl
    Limit of QuantitationNot explicitly stated3.3 mg/dl5.20 mg/dl
    Accuracy and PrecisionCV Total < 5% (Implied)CV Total < 4.82%CV Total < 4.36%
    LinearityAdequate range for clinical use (Implied)3.9 mg/dl - 900 mg/dl5.20 mg/dl - 252 mg/dl
    Measuring rangeAdequate for clinical use (Implied)3.9 mg/dl - 900 mg/dl (up to 2700 mg/dl with auto-dilution)5.20 mg/dl - 252.00 mg/dl (up to 756.00 mg/dl with auto-dilution)
    Correlation (R²) vs. Reference> 0.99 (Implied, from context of "correlation coefficient")r² = 0.997 (Y = 0.96 x + 0.84 mg/dl)r² = 0.9949 (Y = 1.01 x + 0.99 mg/dl)
    Calibration stabilityNot explicitly stated21 days15 days
    Reagent stability (closed)Not explicitly stated36 months at 2-8°C36 months at 2-8°C
    Reagent stability (on-board)Not explicitly stated55 days (refrigerated area)41 days (refrigerated area)

    Note: The document states that the performance testing data demonstrated that the devices "met all acceptance criteria." However, explicit numerical acceptance criteria are not provided for all metrics. The reported performance values themselves serve as the demonstration of meeting internal acceptance criteria. For correlation, an R² value of >0.99 is generally considered excellent in such studies, hence the implied criterion. For CV Total, often <5% is an industry standard for analytical precision.


    2. Sample Size Used for the Test Set and Data Provenance

    • Glucose HK CP:
      • Sample Size: n=208 (for correlation study on urine samples).
      • Data Provenance: Not explicitly stated (e.g., country of origin, retrospective/prospective). This information is typically proprietary. The submission is from France, which might imply data from that region, but it's not confirmed. It's likely retrospective data collection from clinical samples.
    • Uric Acid CP:
      • Sample Size: n=226 (for correlation study on urine samples).
      • Data Provenance: Not explicitly stated (same as above).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This type of information is not applicable to this submission. The "devices" in question are in vitro diagnostic assays for quantitative determination of analytes (glucose and uric acid). The "ground truth" for these tests is established by a reference method or a comparative device, not by expert interpretation of images or clinical cases.


    4. Adjudication Method for the Test Set

    This is not applicable as the ground truth is established by a quantitative measurement method, not through expert scoring or review requiring adjudication.


    5. If a Multi-reader Multi-case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This is not applicable. This submission concerns quantitative in-vitro diagnostic assays, not AI-assisted image interpretation or clinical decision support systems involving human readers.


    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    This is not applicable. These are reagent-based assays run on an automated analyzer (ABX PENTRA 400), not standalone algorithms. Their performance is inherently "standalone" in the sense that the analyzer provides a direct quantitative result.


    7. The Type of Ground Truth Used

    The ground truth used for these quantitative assays is a comparative method or reference method. The correlation studies (e.g., Y = 0.96 x + 0.84 mg/dl) indicate a comparison to a "reference" method, where 'x' typically represents the result from the reference method and 'Y' represents the result from the new device. The document does not specify what the exact reference method was, but for glucose and uric acid, these are well-established laboratory techniques.


    8. The Sample Size for the Training Set

    This information is not provided and is generally not applicable in the context of traditional quantitative IVD assays like these. These methods are developed based on chemical principles and validation studies, not "trained" on data sets in the way AI algorithms are.


    9. How the Ground Truth for the Training Set was Established

    This is not applicable for the reasons outlined in point 8. The assays are based on established enzymatic reactions and photometric measurement, not on a "training set" with ground truth established through a separate process.

    Ask a Question

    Ask a specific question about this device

    K Number
    K072141

    Validate with FDA (Live)

    Date Cleared
    2008-06-24

    (327 days)

    Product Code
    Regulation Number
    862.1580
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    . § 862.1775, Product code KNK

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The S-Test Inorganic Phosphorous Reagent is intended for the quantitative determination of inorganic phosphorous concentration in serum or heparin plasma using the S40 Clinical Analyzer. Measurements of phosphorus (inorganic) are used in the diagnosis and treatment of various disorders, including parathyroid gland and kidney diseases, and vitamin D imbalance. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    The S-Test Uric Acid Reagent is intended for the quantitative determination of uric acid concentration in serum or heparin plasma using the S40 Clinical Analyzer. Uric acid measurements are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and of patients receiving cytotoxic drugs. This test is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    Device Description

    The S-Test inorganic phosphorus (IP) reagent cartridge, used with the S40 Clinical Analyzer, is intended for quantitative in vitro diagnostic determination of IP in serum or heparin plasma based on a photometric test measuring the formation of molybdenum blue from IP and ammonium molybdate.

    The S-Test uric acid (UA) reagent cartridge, used with the S40 Clinical Analyzer, is intended for quantitative in vitro diagnostic determination of UA in serum or heparin plasma based on a photometric test measuring the formation of a reddish-purple pigment.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the Alfa Wassermann S-Test IP and S-Test UA reagent cartridges, based on the provided 510(k) summary:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are not explicitly stated as distinct pass/fail thresholds in a separate section. Instead, the "Performance Data" section describes the results of various tests, and the "Conclusions" section states that the device is "safe and effective" and demonstrates "substantial equivalence to the predicate devices" based on this data. I will present the reported performance data, which implicitly serves as the criteria met for acceptance.

    S-Test Inorganic Phosphorus (IP) Reagent Cartridge

    Performance MetricAcceptance Criteria (Implicit from Results)Reported Device Performance
    Precision
    22-day testing (within-run CV)Low variability (e.g., CV < 5%)1.5% to 2.9% (at 3 IP levels)
    22-day testing (total CV)Low variability (e.g., CV < 5%)2.6% to 4.0% (at 3 IP levels)
    5-day POL & in-house (within-run CV)Low variability (e.g., CV < 5%)0.9% to 3.4%
    5-day POL & in-house (total CV)Low variability (e.g., CV < 5%)1.2% to 3.4%
    Accuracy (Correlation to Comparison Method)Strong correlation (e.g., r > 0.95), low error, slope near 1, intercept near 0
    Main Study (Correlation Coefficient)r > 0.950.976
    Main Study (Std. Error Estimate)Low error0.3
    Main Study (Confidence Interval Slope)Encompassing 11.026 to 1.150
    Main Study (Confidence Interval Intercept)Encompassing 0-0.03 to 0.34
    POL Studies (Correlation Coefficient)r > 0.950.992 to 0.998
    POL Studies (Std. Error Estimate)Low error0.10 to 0.21
    POL Studies (Confidence Interval Slope)Encompassing 11.002 to 1.173
    POL Studies (Confidence Interval Intercept)Encompassing 0-0.075 to 0.395
    SensitivityDetect low concentrations (e.g., clinically relevant levels)Detection limit: 1.2 mg/dL

    S-Test Uric Acid (UA) Reagent Cartridge

    Performance MetricAcceptance Criteria (Implicit from Results)Reported Device Performance
    Precision
    22-day testing (within-run CV)Low variability (e.g., CV < 5%)0.9% to 2.1% (at 3 UA levels)
    22-day testing (total CV)Low variability (e.g., CV < 5%)3.1% to 3.5% (at 3 UA levels)
    5-day POL & in-house (within-run CV)Low variability (e.g., CV < 5%)0.3% to 2.2%
    5-day POL & in-house (total CV)Low variability (e.g., CV < 5%)0.7% to 2.3%
    Accuracy (Correlation to Comparison Method)Strong correlation (e.g., r > 0.95), low error, slope near 1, intercept near 0
    Main Study (Correlation Coefficient)r > 0.950.974
    Main Study (Std. Error Estimate)Low error0.7
    Main Study (Confidence Interval Slope)Encompassing 11.003 to 1.087
    Main Study (Confidence Interval Intercept)Encompassing 0-1.03 to -0.49
    POL Studies (Correlation Coefficient)r > 0.950.967 to 0.995
    POL Studies (Std. Error Estimate)Low error0.32 to 0.69
    POL Studies (Confidence Interval Slope)Encompassing 10.968 to 1.202
    POL Studies (Confidence Interval Intercept)Encompassing 0-1.400 to 0.469
    SensitivityDetect low concentrations (e.g., clinically relevant levels)Detection limit: 1.4 mg/dL

    2. Sample Size Used for the Test Set and Data Provenance

    • S-Test IP:
      • Sample Size: 95 samples for the main correlation study. "Patient correlation studies at three separate POL sites" are also mentioned, implying additional samples, but the total number for these POL studies is not explicitly stated.
      • Data Provenance: Not explicitly stated, but "patient correlation studies at three separate POL sites" and "in-house" studies suggest data collected from different clinical settings and the manufacturer's laboratory, likely within the US given the context of a US FDA submission. It is reasonable to assume these were prospective or a mix of retrospective and prospective, as "patient samples" would either be freshly collected or archived. The summary does not specify.
    • S-Test UA:
      • Sample Size: 183 samples for the main correlation study. Similar to IP, "patient correlation studies at three separate POL sites" were also conducted, with the total sample size for these not specified individually.
      • Data Provenance: Similar to IP, likely from various clinical sites (POLs) and in-house, presuming US origin. The summary does not explicitly state if the data was retrospective or prospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not provided in the document. The "ground truth" for these types of diagnostic tests is typically established by comparison to a recognized predicate or reference method run on a different, established analyzer (as indicated by "comparison method" in the accuracy studies) rather than human expert interpretation of raw data.

    4. Adjudication Method for the Test Set

    This information is not applicable/not provided as the ground truth is established through a quantitative comparison method, not expert consensus requiring adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    This information is not applicable. This is not an AI/imaging device that involves human readers or an MRMC study. It is an in vitro diagnostic device for chemical analysis.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This information is not applicable. This describes the performance of a reagent cartridge on a clinical analyzer, which is inherently a "standalone" measurement system for the biochemical assay it performs. There is no "algorithm" in the AI sense, nor a human-in-the-loop component for interpretation of the primary measurement.

    7. The Type of Ground Truth Used

    The ground truth was established by a "comparison method" using predicate or reference devices/methods. This means the results from the S-Test cartridges on the S40 Clinical Analyzer were compared against measurements from other commercially available, legally marketed diagnostic systems (e.g., ACE plus ISE/Clinical Chemistry System, Olympus AU640 Clinical Chemistry Analyzer, Piccolo® xpress Chemistry Analyzer reagents or similar) that measure inorganic phosphorus and uric acid.

    8. The Sample Size for the Training Set

    This information is not provided. Given that this is a traditional in vitro diagnostic device measuring chemical concentrations, there isn't a "training set" in the machine learning sense. The device's performance characteristics (precision, accuracy, sensitivity) are inherently part of its design and manufacturing process, and validated through the performance studies described, rather than "trained" on data.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable as there is no "training set" in the context of this device. The reagents and analyzer are developed and manufactured to perform the specified chemical reactions, with their analytical performance validated through studies against established methods.

    Ask a Question

    Ask a specific question about this device

    K Number
    K062862

    Validate with FDA (Live)

    Date Cleared
    2007-04-06

    (193 days)

    Product Code
    Regulation Number
    862.1775
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    75063-3104

    APR - 6 2007

    Re: K062862 Trade Name: Olympus Uric Acid Reagent Regulation Number: 21 CFR §862.1775

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    System reagent for the quantitative determination of Uric Acid in human serum, heparinized plasma and urine on OLYMPUS analyzers

    Measurements of Uric Acid are used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and of patients receiving cytotoxic drugs.

    Device Description

    Not Found

    AI/ML Overview

    The provided text focuses on the FDA's 510(k) clearance of the Olympus Uric Acid Reagent, establishing its substantial equivalence to a predicate device. However, the document does not contain the detailed study information required to fully answer your request regarding acceptance criteria and performance studies.

    Therefore, I cannot populate the table or provide specific answers to most of your questions based solely on the provided text. The document is a regulatory clearance letter, not a scientific study report.

    Here's what I can extract and what is missing:

    Information Present:

    • Device Name: Olympus Uric Acid Reagent
    • Intended Use: Quantitative determination of Uric Acid in human serum, heparinized plasma, and urine on OLYMPUS analyzers.
    • Clinical Utility: Used in the diagnosis and treatment of numerous renal and metabolic disorders, including renal failure, gout, leukemia, psoriasis, starvation or other wasting conditions, and patients receiving cytotoxic drugs.
    • Regulatory Clearance: 510(k) clearance (K062862) issued on April 6, 2007.

    Information NOT Present (and why it's typically in a study report, not a clearance letter):

    • Acceptance Criteria and Reported Device Performance Table: The document doesn't list specific performance metrics (like accuracy, precision, linearity, limits of detection) or the thresholds for acceptable performance. It only states the device is substantially equivalent, implying its performance is comparable to an existing device.
    • Sample Size for Test Set and Data Provenance: This information would be detailed in a validation study report.
    • Number of Experts and Qualifications: Not relevant for a chemistry reagent validation; typically for image-based diagnostics where human interpretation is involved.
    • Adjudication Method: Not relevant for a chemistry reagent.
    • MRMC Comparative Effectiveness Study: Not relevant for a chemistry reagent. This applies to diagnostic tools where human interpretation is augmented by AI.
    • Standalone Performance: While the "device" (reagent) performs standalone, the document doesn't provide the specific performance data.
    • Type of Ground Truth Used: For a chemistry assay, the ground truth would typically be established using a reference method or certified reference materials with known uric acid concentrations. The document doesn't specify this.
    • Sample Size for Training Set: Not applicable in the context of a chemical reagent validation in the same way it would be for a machine learning model.
    • How Ground Truth for Training Set was Established: Again, not applicable as there's no "training set" in the machine learning sense for this type of device.

    Conclusion:

    The provided document is a regulatory approval letter. While it confirms the device's market readiness and intended use, it does not contain the detailed technical specifications or study results required to answer your specific questions about acceptance criteria and performance study design. This information would typically be found in the 510(k) submission summary or a separate validation study report, which is not included here.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 3