    Intended Use

    The Dimension Vista® Magnesium Flex® reagent cartridge (MG) method is an in vitro diagnostic test for the quantitative measurement of magnesium in human serum, plasma and urine on the Dimension Vista® System. Magnesium measurements are used in the diagnosis and treatment of hypomagnesemia (abnormally low plasma levels of magnesium) and hypermagnesemia (abnormally high plasma levels of magnesium).

    The Dimension Vista® Chemistry 1 Calibrator (CHEM 1 CAL) is an in vitro diagnostic product for the calibration of Blood Urea Nitrogen (BUN),Calcium (CA), Cholesterol (CHOL), Creatinine (CRENCRE2), Glucose (GLU), Lactic Acid (LA), Magnesium (MG), Thyroxine (T4), Thyronine Uptake (TU) and Uric Acid (URCA) methods on the Dimension Vista® System.

    Device Description

    CHEM 1 CAL is a liquid, frozen multi-analyte, bovine serum albumin based product used to calibrate blood urea nitrogen, calcium, cholesterol, creatinine, glucose, lactic acid, magnesium, thyroxine, thyronine uptake and uric acid. The kit consists of six vials, three vials of Calibrator A and three vials of Calibrator B.

    The Dimension Vista® MG Flex® reagent cartridge uses a modified methylthymol blue (MTB) complexometric technique. MTB forms a blue complex with magnesium. Calcium interference is minimized by forming a complex between calcium and Ba-EGTA (chelating agent). The amount of MG-MTB complex formed is proportional to the magnesium concentration and is measured using a bichromatic (600 and 510 nm) endpoint technique.

    AI/ML Overview

    The provided text describes the performance characteristics of the Dimension Vista® Magnesium Flex® reagent cartridge (MG) and the Dimension Vista® Chemistry 1 Calibrator (CHEM 1 CAL). The focus is on demonstrating substantial equivalence to predicate devices and meeting established clinical laboratory guidelines. However, the information is primarily focused on analytical performance rather than clinical effectiveness or diagnostic accuracy in specific patient populations.

    Here's an attempt to extract the requested information, acknowledging that some categories may not be directly applicable or fully detailed given the nature of an in vitro diagnostic device's analytical validation.


    1. Table of Acceptance Criteria and Reported Device Performance

    Device: Dimension Vista® Magnesium Flex® reagent cartridge (MG) for quantitative measurement of magnesium.

    Performance CharacteristicAcceptance Criteria (Implicit from CLSI Guidelines and Study Design)Reported Device Performance (MG Assay)
    Method Comparison (Correlation)High correlation (e.g., r > 0.975) with a legally marketed device; slope close to 1, intercept close to 0.Serum: Slope: 1.10, Intercept: -0.15 mg/dL, Correlation Coefficient: 1.00 (vs. Beckman AU Magnesium assay)
    Lithium Heparin Plasma: Slope: 1.05, Intercept: -0.01 mg/dL, Correlation Coefficient: 0.994 (vs. Beckman AU Magnesium assay)
    Urine: Slope: 1.05, Intercept: 0.09 mg/dL, Correlation Coefficient: 0.995 (vs. Beckman AU Magnesium assay)
    Precision (Repeatability & Within-Lab CV%)Low Coefficient of Variation (CV%) as per CLSI EP05-A2. (Specific numerical criteria are not explicitly stated, but typical ranges for clinical assays are often <10% for low concentrations and <5% for higher concentrations).Multiqual® Unassayed Control: Level 1 (1.1 mg/dL): Repeatability 4.8%, Within-Lab 5.1%; Level 2 (2.5 mg/dL): Repeatability 2.9%, Within-Lab 2.9%; Level 3 (4.0 mg/dL): Repeatability 1.9%, Within-Lab 2.4%.
    Serum Pool: Pool 1 (1.9 mg/dL): Repeatability 3.4%, Within-Lab 3.7%; Pool 2 (4.5 mg/dL): Repeatability 1.8%, Within-Lab 2.1%.
    Liquichek™ Urine Chemistry Control: Level 1 (7.0 mg/dL): Repeatability 1.2%, Within-Lab 1.5%.
    Urine Pool: Pool 1 (7.3 mg/dL): Repeatability 1.0%, Within-Lab 1.3%.
    Limit of Blank (LoB)Consistent with claimed analytical sensitivity.Serum: 0.002 mg/dL (Claimed: 0.2 mg/dL)
    Urine: 0.2 mg/dL (Claimed: 0.2 mg/dL)
    Limit of Detection (LoD)Consistent with claimed analytical sensitivity, with false positives and negatives <5%.Serum: 0.1 mg/dL (Claimed: 0.3 mg/dL)
    Urine: 0.3 mg/dL (Claimed: 0.3 mg/dL)
    Limit of Quantitation (LoQ)Total Error (TE) ≤ 0.2 mg/dL.Serum: 0.2 mg/dL (Supports claim of 0.3 mg/dL)
    Urine: 0.3 mg/dL (Supports claim of 0.3 mg/dL)
    LinearityHigh correlation coefficient (close to 1), slope close to 1, intercept close to 0 across the assay range.Serum: Range 0.4-11.4 mg/dL, Slope: 1.0109, Intercept: -0.0089, Corr Coef: 0.9998
    Urine: Range 0.3-11.4 mg/dL, Slope: 0.9997, Intercept: 0.0583, Corr Coef: 0.9986

    2. Sample Sizes Used for the Test Set and Data Provenance

    • Method Comparison Study:
      • Serum and Plasma: 239 samples (combined total).
      • Urine: 99 samples.
      • Data Provenance: Retrospective, internal testing by Siemens Healthcare Diagnostics R&D personnel. The country of origin is not specified but implicitly assumed to be the location of the Siemens R&D facility.
    • Precision Testing:
      • Not reported as individual patient samples. Instead, it used control materials (Multiqual QC, Liquichek Urine QC) and pooled serum/urine samples.
      • Each test material was run with two test samples over 20 days, in two separate runs.
    • Limit of Blank/Detection (LoB/LoD):
      • Serum (LoB/LoD): 96 determinations (based on 4 blank and 4 low-level samples, tested n=5 over 3 days, using 2 reagent lots).
      • Urine (LoB/LoD): 96 determinations (based on 4 blank and 4 low-level samples, tested n=5 over 3 days, using 2 reagent lots).
    • Limit of Quantitation (LoQ):
      • Serum: 6 serum samples, 5 replicates (n=5) of each, with 2 reagent lots, over 3 days (total of 90 replicates per lot for serum).
      • Urine: 6 urine samples, 5 replicates (n=5) of each, with 2 reagent lots, over 3 days (total of 90 replicates per lot for urine). Total 180 determinations for LoQ overall.
    • Linearity Testing:
      • Serum: 9 prepared samples (dilutions).
      • Urine: 9 prepared samples (dilutions).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    The term "ground truth" typically applies to diagnostic accuracy studies where expert consensus or a gold standard (e.g., pathology) is used to classify cases. For an in vitro diagnostic device measuring an analyte concentration, the "ground truth" for the test set is established by testing the same samples using a legally marketed predicate device (Beckman AU Magnesium assay in this case) or through reference materials (e.g., NIST SRM 929 for traceability of the calibrator).

    • For Method Comparison: No external experts were explicitly mentioned for interpreting results. The comparison itself uses the Beckman AU Magnesium assay as the reference.
    • For Calibrator Traceability: Magnesium is traceable to NIST SRM 929 (National Institute of Standards and Technology Standard Reference Material). This implies the ground truth for calibration levels is established by a highly reputable and standardized reference.

    4. Adjudication Method for the Test Set

    Adjudication methods (like 2+1, 3+1) are typically used in studies involving subjective interpretation (e.g., imaging) to resolve disagreements among human readers. This concept is not directly applicable to the analytical performance studies of a quantitative in vitro diagnostic device, where results are numerical values. Discrepancies in quantitative measurements would typically be investigated through repeat testing, instrument troubleshooting, or sample re-preparation, rather than expert adjudication of an interpretation.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not done. This type of study assesses how human readers' diagnostic performance changes with and without AI assistance. The submitted device is a quantitative in vitro diagnostic reagent cartridge and calibrator, not an AI-powered diagnostic imaging or interpretation tool designed to assist human readers. Therefore, the concept of "human readers improve with AI vs without AI assistance" is not relevant to this device.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    While the device itself is a standalone analytical system (it measures magnesium concentrations automatically), the studies conducted are analytical performance studies, not a standalone diagnostic performance study in the sense of an algorithm interpreting clinical data to make a diagnosis without human input. The output is a quantitative measure of magnesium, which a clinician then interprets in the context of a patient's overall health.

    The device itself represents "algorithm only" performance in the sense that it mechanically and biochemically performs the assay without human interpretation during the measurement process. The analytical studies (precision, linearity, LoD, etc.) demonstrate this standalone analytical performance.

    7. The Type of Ground Truth Used

    • For Method Comparison: The "ground truth" was established by comparison with a legally marketed predicate device, the Beckman AU Magnesium assay (K981743). This is a common approach for demonstrating substantial equivalence for in vitro diagnostics.
    • For Calibrator Traceability: The ground truth for magnesium levels in the calibrator is traced to NIST SRM 929, which is a primary reference standard. This provides a highly accurate and standardized "ground truth" for the calibrator values.
    • For Studies like LoB, LoD, LoQ, Linearity, Precision: The ground truth for these analytical performance characteristics is derived from statistical analysis of repeated measurements against well-defined samples (e.g., blank samples, low-level samples, serially diluted samples) and comparison to established CLSI guidelines for acceptable performance.

    8. The Sample Size for the Training Set

    The document does not specify a "training set" in the context of machine learning or AI algorithm development. This device is a traditional in vitro diagnostic reagent, relying on a biochemical reaction and photometric measurement, not a machine learning model that requires a discrete training phase. Therefore, the concept of a separate training set is not applicable here. The development and optimization of the reagent formulation and instrument settings would have involved extensive R&D, but this is not typically characterized as a "training set" in the AI/ML sense.

    9. How the Ground Truth for the Training Set Was Established

    As noted above, there is no "training set" in the AI/ML sense for this device. The physical and chemical properties of magnesium and the methylthymol blue reaction are the underlying "truth" guiding the development of the assay. Calibrator values leverage traceability to NIST SRM 929.

    Ask a Question

    Ask a specific question about this device

    K Number
    K140248

    Validate with FDA (Live)

    Date Cleared
    2014-03-11

    (40 days)

    Product Code
    Regulation Number
    862.1160
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K111753, K981743

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The S TEST Reagent Cartridge Carbon Dioxide (CO2) is intended for the quantitative determination of carbon dioxide concentration in serum or lithium heparin plasma using the HITACHI Clinical Analyzer E40. Carbon dioxide measurements are used in the diagnosis and treament of numerous potentially serious disorders associated with changes in body acid-base balance. The S TEST Reagent Cartridge Carbon Dioxide (CO2) is intended for use in clinical laboratories or physician office laboratories. For in vitro diagnostic use only.

    Device Description

    The Hitachi Clinical Analyzer is an automatic, bench-top, wet chemistry system intended for use in clinical laboratories or physician office laboratories. The instrument consists of a desktop analyzer unit, an operations screen that prompts the user for operation input and displays data, a printer, and a unit cover. The analyzer unit includes a single probe, an incubation rotor, carousels for sample cups and reagent cartridges, and a multi-wavelength photometer. The single-use reagent cartridges may be placed in any configuration on the carousel, allowing the user to develop any test panel where the reagent cartridges are available. The S TEST reagent cartridges are made of plastic and include two small reservoirs capable of holding two separate reagents (R1 and R2), separated by a reaction cell/photometric cuvette. The cartridges also include a dot code label that contains all chemistry parameters, calibration factors, and other production-related information, e.g., expiration dating. The dimensions of the reagent cartridges are: 13.5 mm (W) × 28 mm (D) × 20.2 mm (H). System operation: After the sample cup is placed into the carousel, the analyzer pipettes the sample, pipettes the reagent, and mixes (stirs) the sample and reagent together. After the sample and reagent react in the incubator bath, the analyzer measures the absorbance of the sample, and based on the absorbance of the reactions, it calculates the concentration of analyte in the sample. The test system can measure analytes in serum or plasma and results are available in approximately 15 minutes per test. This submission is for Reagent Cartridge Carbon Dioxide.

    AI/ML Overview

    The provided text describes the 510(k) summary for the Hitachi S TEST Reagent Cartridge Carbon Dioxide (CO2), a device for quantitative determination of carbon dioxide concentration in serum or lithium heparin plasma. The document focuses on demonstrating the substantial equivalence of this device to a legally marketed predicate device (Carbon Dioxide L.3K Assay, Sekisui Diagnostics, PEI, Inc., Canada- K042362) through nonclinical and clinical performance studies.

    Here's an analysis of the acceptance criteria and the studies conducted:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of "acceptance criteria" but rather describes the performance characteristics tested and their results, often comparing them to the predicate device or established standards. I will infer acceptance criteria based on standard clinical chemistry performance requirements and the described study outcomes.

    Performance CharacteristicAcceptance Criteria (Inferred/Standard)Reported Device Performance (Hitachi S TEST CO2)
    Analytical Sensitivity (Limit of Detection - LoD)Typically, LoD should be low enough to detect clinically relevant low concentrations. LoQ (Limit of Quantitation) should have acceptable precision (e.g., %CV < 20%).- Limit of Blank (LoB): 0.7 mmol/L - Limit of Detection (LoD): 0.9 mmol/L - Limit of Quantitation (LoQ): ~4 mmol/L with %CVs < 11%
    LinearityVisual inspection of regression, r² > 0.99, slope near 1, y-intercept near 0, within specified reportable range.y = 0.918x + 0.091; r² = 0.9988 Range: 1.4 to 44.0 mmol/L (Reportable range: 5 to 40 mmol/L)
    Precision (In-house)%CVs should be within acceptable clinical limits for different concentration levels (typically lower %CV for higher concentrations).Within-Run %CV (Total %CV) - Low (10.11 mmol/L): 1.3% (4.4%) - Middle (19.41 mmol/L): 1.3% (3.7%) - High (33.06 mmol/L): 1.2% (3.7%)
    Precision (External POL Study)Similar to in-house, %CVs within acceptable clinical limits.Total %CV (n=30 for each level at each site) - Site 1: 4.1% (Low), 4.8% (Mid), 3.2% (High) - Site 2: 6.0% (Low), 4.4% (Mid), 3.7% (High) - Site 3: 3.1% (Low), 1.9% (Mid), 3.7% (High)
    InterferenceRecoveries between 90% and 110% of the neat value in the presence of interferents.No interference from Lipemia (up to 1,000 mg/dL Intralipid), Ascorbic acid (up to 50 mg/dL), Hemoglobin (up to 1,000 mg/dL), Unconjugated bilirubin (up to 19.1 mg/dL)
    Method Comparison (Accuracy)Strong correlation (r > 0.95), slope close to 1, y-intercept close to 0, and agreement with predicate/reference method.In-house (vs. standard lab system): n=96, r=0.981, Slope=1.03 (0.97-1.08), y-intercept=0.98 (-0.17-2.12) External POL Study (vs. comparative method): - Site 1: n=47, r=0.984, y=0.91x+1.49 (Slope CI: 0.87-0.95, Intercept CI: 0.67-2.32) - Site 2: n=45, r=0.970, y=0.92x+0.56 (Slope CI: 0.80-1.04, Intercept CI: -2.31-3.43) - Site 3: n=47, r=0.982, y=0.92x+0.79 (Slope CI: 0.87-0.97, Intercept CI: -0.43-2.01)
    Matrix Comparison (Serum vs. Plasma)Strong correlation between serum and plasma results (r > 0.95), slope close to 1, y-intercept close to 0.n=50, r=0.980, Slope=1.00 (0.94-1.05), y-intercept=-0.34 (-1.97-1.30)
    Stability (Shelf Life)Claimed shelf life supported by real-time stability data.Supported shelf life of 6 months at 2-8°C (real-time testing ongoing).
    Reportable RangeMatch clinical requirements; within demonstrated linearity.5.0 to 40.0 mmol/L (Predicate: 2.9 to 50.0 mmol/L)
    Detection WavelengthNot an acceptance criterion for performance, but a technical specification.405/508 nm (Predicate: 405/415 nm)

    2. Sample Size Used for the Test Set and Data Provenance

    • Analytical Sensitivity (LoD/LoQ): 60 replicates of reagent blank and three low samples. Three low-level specimens in six runs with three instruments over three days for LoQ.
    • Linearity: 10 serial dilutions plus zero standard (n=11), assayed in duplicate.
    • Precision (In-house): Three levels of serum-based commercial controls, each tested in two runs, twice a day, for 20 days.
    • Interference Testing: Two serum pools with approximately 17 and 30 mmol/L carbon dioxide.
    • Method Comparison (In-house): 96 clinical specimens (including 3 spiked and 3 diluted samples).
    • Matrix Comparison: 50 matched serum/plasma samples (including 2 spiked and 4 diluted samples).
    • Precision (External POL Study): Three blinded serum samples (low, middle, high CO2 concentrations). Each sample assayed six times per day for five days, reporting 30 results per level per site.
    • Method Comparison (External POL Study): 47 serum specimens (including three spiked and four diluted samples) per site (Site 2 used 45 samples due to 2 below dynamic range).

    Data Provenance:

    • The studies were performed by Hitachi Chemical Diagnostics, Inc. ("in-house") and at three external Physician Office Laboratory (POL)-type sites.
    • Specific countries of origin for the clinical specimens are not explicitly stated, but the company address is Mountain View, CA, USA, and POL studies suggest U.S. clinical settings.
    • The studies appear to be prospective for the purpose of validating the device's performance characteristics.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The document does not specify the number or qualifications of experts used to establish "ground truth" for the test set in the traditional sense of expert consensus for diagnostic interpretation. Instead, the ground truth is established through:

    • Reference Methods/Comparative Methods: In the method comparison studies, a "standard laboratory system" or "comparative method as the reference method" was used. The qualifications of the operators of these reference methods are not provided.
    • Known Concentrations: For studies like linearity, precision, and interference, known concentrations (e.g., commercial controls, spiked samples, diluted samples) are used.
    • Industry Standards: Adherence to CLSI (Clinical and Laboratory Standards Institute) guidelines (e.g., CLSI EP17-A2, CLSI EP-6A, CLSI EP5-A2, CLSI EP7-A2) implies reliance on established laboratory best practices for determining analytical performance.

    4. Adjudication Method for the Test Set

    This type of in vitro diagnostic device (IVD) performance study (analytical and clinical chemistry accuracy/precision) typically does not involve adjudication by multiple human readers in the same way an imaging or pathology study might. Instead, the device's results are compared against:

    • Reference measurements: From the predicate device or a "standard laboratory system."
    • Known values: For controls, linearity standards, and spiked/diluted samples.
      The document states that method comparison samples were assayed "in singleton and in a blinded fashion" (in-house) and "assayed on the Hitachi E40 Clinical Analyzer... and a comparative method as the reference method" (external POL study), implying direct comparison without a formal adjudication panel.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not done. This type of study design is typically used for diagnostic imaging or pathology devices where multiple human readers interpret cases, and the AI's impact on their performance is assessed. For an in vitro diagnostic (IVD) device like a CO2 reagent cartridge, the evaluation focuses on analytical performance characteristics (accuracy, precision, linearity, etc.) rather than human reader improvement with AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop) Performance Was Done

    Yes, the studies conducted are standalone performance studies. The Hitachi S TEST Reagent Cartridge Carbon Dioxide operates as an in vitro diagnostic device on an automated analyzer (Hitachi Clinical Analyzer E40). The performance results (accuracy, precision, linearity, etc.) described are the performance of the device and its associated system without direct "human-in-the-loop" interpretive input influencing the result generation. Human operators load samples and reagents and review results, but the device itself generates the quantitative CO2 concentration.

    7. The Type of Ground Truth Used

    The ground truth for the performance studies was established using a combination of:

    • Reference Measurement/Comparative Method: For method comparison, results from a "standard laboratory system" or "comparative method" served as the reference.
    • Known Values: For analytical studies like linearity, precision, LoD, and interference, commercial controls, calibrators, and spiked/diluted samples with known or traceable concentrations were used.
    • Industry Standards: Adherence to CLSI guidelines ensures that the methods for establishing ground truth for these analytical parameters align with recognized best practices in laboratory medicine.

    8. The Sample Size for the Training Set

    The document does not describe a "training set" in the context of machine learning or AI development. This is an IVD device providing a quantitative measurement based on a chemical reaction and photometric detection. Its underlying "algorithm" is the chemistry reaction and calculation based on Beer-Lambert Law, not a learned AI model that requires a training set. Manufacturers establish internal specifications and calibration parameters based on extensive R&D and analytical validation, but this typically does not involve an external "training set" as understood in AI/ML.

    9. How the Ground Truth for the Training Set Was Established

    As explained above, there is no "training set" for this type of IVD device in the AI sense. The "ground truth" for manufacturing and calibration would be established through:

    • Primary Reference Materials: Traceability to primary reference standards (e.g., American Chemical Society (ACS) reagent grade sodium carbonate alkalimetric standard for CO2).
    • Internal Validation: Rigorous internal testing and validation during the device's development to ensure the chemical reaction and photometric measurements yield accurate and precise results across the dynamic range.
    • Quality Control: Ongoing use of quality control materials with known values to monitor performance.
      The document states, "Each lot of S TEST Reagent Cartridge Carbon Dioxide (CO2) is calibrated by the manufacturer prior to shipment using material referenced to a standard which is traceable to American Chemical Society (ACS) reagent grade sodium carbonate alkalimetric standard." This describes the process for establishing and maintaining calibration, which is akin to "ground truth" for the device's quantitative output.