510(k) Data Aggregation

    K Number
    K081612

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2008-06-25

    (16 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K960475

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The intended use of the product(s) is to communicate the laser beam of a CO, surgical laser to the target site for the incision, excision, ablation, or photocoagualtion of soft tissue. Representative examples of clinical applications include:

    Gynecology--excision and vaporization of cervical, vulvar, and perineal condyloma: ablation of vaginal and vulvar intraepithelial neoplasia; herpes vaporization of urethral caruncle; I&D Bartholin's and nubothian cysts

    Dermatology--port wine hemangioma removal; rhinophyma reduction; telangiectasia removal; wart removal; basal squamous cell carcinomoa removal; blepharoplasty, xanthalasma removal; removal of neurofibromas hemangiomas, nevi, and tircoeptiheliomas; dermabrasion for lentigos, keratoses, actinic keratosis and actinic chleilitis

    Dentistry/Oral Surgery-gingivectomy; frenum release; gingivoplasty; removal of soft tissue, cysts, and tumors

    General Surgery--hemorthoid removal; skin tag vaporization; pilodidal cyst removal and repair; debridement of decubitus ulcers and stasis ulcers; mastectomy; breast biopsy, reduction mammoplasty; cytoreduction for metastatic disease; many dermatological procedures

    Laparoscopic Surgery--vaporization, incision, excision, ablation, or photo-coagulation of soft tissue such as endometriosis ablation, excision of adhesions, salpingotomy

    Otorhinolaryngology--lymphangioma removal; turbinectomy, subglottic stenosis vaporization, tonsilectomy, removal of vocal cord papillomas, nodules, and polyps

    Podiatry-plantar wart vaporization; fungal nail treatment; partial and complete mattixectomy; porokeratoma ablation; Morton's neurome removal; ingrown toenail treatment

    Orthopedic -- menisectorny, chondromalacia abalation, partial synovectomy, lateral release, PMMA removal

    No new indications for use are sought beyond those associated with the predicate devices.

    Device Description

    This is a family of detachable devices that comprise the distal portion of a beam delivery system to be used with a CO, surgical laser such as that described in K96075. Specifically, the devices consist of a flexible hollow lightpipe (fiber), handpieces that connect to the fiber, and various tips that connect to the handpieces. The tips are short, rigid hollow alumina lightpipes producing a variety of spot sizes. The user may "mix and match" handpieces and tips to suit the clinical task at hand.

    AI/ML Overview

    This document does not contain information about acceptance criteria or a study proving the device meets acceptance criteria. Instead, it is a 510(k) summary for the Aesculight family of fibers, handpieces, and tips for CO2 surgical lasers. It aims to demonstrate substantial equivalence to a predicate device, not to establish performance against specific acceptance criteria through a clinical study.

    Therefore, I cannot provide the requested information in the table format or answer the questions related to studies, sample sizes, experts, ground truth, or MRMC studies, as this information is not present in the provided text.

    The document discusses:

    • Product Description: Detachable devices for CO2 surgical lasers (flexible hollow lightpipe, handpieces, and tips).
    • Intended Use: To communicate the laser beam for incision, excision, ablation, or photocoagulation of soft tissue in various medical fields.
    • Technological Characterization: Compares the Aesculight products with the predicate device (Modified LX-20 Laser System) focusing on construction differences (e.g., fiber material, tip construction) and asserting that these differences do not introduce new safety or performance concerns. It states that the Aesculight fiber exhibits "somewhat better transmission efficiency" and the tips "have power-handling capabilities that equal or exceed those of the predicate tips."
    • Conclusion: Claims the Aesculight products are substantially equivalent to the predicate products, with "very similar physical and optical characteristics," and that "a user could not distinguish a difference between the predicate products and the Aesculight products, nor do the Aesculight products raise any new safety issues."
    • FDA Clearance Letter: Confirms substantial equivalence to legally marketed predicate devices.

    The information provided is geared towards proving substantial equivalence for FDA 510(k) clearance, which typically relies on demonstrating that the new device is as safe and effective as a legally marketed predicate device, rather than meeting quantitative acceptance criteria through a specific performance study as might be seen for novel devices or in clinical trials.

    Ask a Question

    Ask a specific question about this device

    K Number
    K991628

    Validate with FDA (Live)

    Date Cleared
    1999-08-09

    (90 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K960475, K963229, K935563

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The modified LX-20 Laser System Family is a general surgical instrument used to vaporize, incise, excise, ablate, or photo coagulate soft tissue in surgical procedures in the listed surgical specialties.

    The system may be effectively utilized for those applications recognized as within the accepted indications for use of C0, laser devices performed within the listed specialties and which require power densities as calculated by power and spot size referenced in the power density charts in the operator's manual.

    Indications for Use - Gynecology
    Representative examples: Condyloma, excision and vaporization, cervical, vulvar, & perineal; vaginal intraepithelial neoplasia ablation (VAIN); vulvar intraepithelial neoplasia ablation (VIN); herpes vaporization; urethral caruncle vaporization; I&D Bartholin's & nubothian cysts.

    Indications for Use - Laparoscopic Surgery
    Vaporization, incision, excision, ablation, or photo coagulation of soft tissue in endoscopic and laparoscopic surgery including GYN laparoscopy where delivery of energy by the hollow fiber may be more convenient than delivery of energy by a handpiece. Representative examples: endometriosis ablation; excision of adhesions; salpingotomy; metroplasty,

    Indications for Use - Dermatology
    Representative examples: Tattoo removal; port wine hemangioma removal; rhinophyma reduction; telangiectasia removal; keloid reduction; wart removal; basal & squamous cell carcinoma removal; blepharoplasty; xanthalasma removal; removal of neurofibromas, hemangiomas, nevi, and tricoepitheliomas; dermabrasion such as for lentigos, keratoses, actinic keratosis & cheilitis.

    Indications for Use - Dental/Oral Surgery
    Representative examples: Gingivectomy; frenum release; removal of soft tissue, cysts, and tumors.

    Indications for Use - Orthopedic
    Representative examples: Menisectomy; chondromalacia ablation; partial synovectomy; lateral release; PMMA removal.

    Indications for Use - General Surgery
    Representative examples: Hemorthoid removal; skin tag vaporization; pilodidal cyst removal and repair: debridement of decubitus ulcers and statis ulcers; mastectomy, breast biopsy, reduction mammoplasty; cytoreduction for metastatic disease; many dermatological procedures.

    Indications for Use - Otorhinolaryngology (ENT)
    Representative examples: Subglottic stenosis vaporization; tonsillectomy; removal of vocal cord papillomas, nodules, and polyps; lymphangioma removal; pulmonary bronchial and tracheal lesion removal: turbinectomy; removal of leukoplakia of larynx; ablation of choanal atresia. Myringotomy/tympanostomy; Laser Assisted Uvulopalatoplasty (LAUP).

    Indications for Use - Podiatry
    Representative examples: Plantar wart vaporization; fungal nail treatment; partial and complete matrixectomy; porokeratoma ablation; Morton's neruoma removal; ingrown nail treatment.

    Device Description

    The Luxar modified LX-20 Surgical Laser System produces laser (infrared) energy at a wavelength of 10.6 microns which is directed to soft tissue through a knuckled beam delivery assembly, articulated arm or articulated arm plus hollow fiber waveguide, handpieces, and sterile delivery tips.

    AI/ML Overview

    The provided text describes a 510(k) summary for the Luxar modified LX-20 C0, Surgical Laser System. This document focuses on demonstrating substantial equivalence to previously cleared devices rather than presenting new clinical study data to prove the device meets acceptance criteria.

    Key takeaway: The submission states, "There are no new indications for use beyond those cleared for the predicate devices, and no clinical data were presented." This directly indicates that a study proving the device meets acceptance criteria, as typically understood for new performance claims, was not conducted or presented in this 510(k) submission. Therefore, I cannot provide information on acceptance criteria or a study proving they were met.

    However, I can extract information related to the device's intended use and the basis for its clearance:


    1. Table of acceptance criteria and the reported device performance

    • Acceptance Criteria: Not explicitly stated as this is a substantial equivalence submission based on predicate devices, not a de novo clearance requiring new performance data. The "acceptance criteria" effectively are that the device performs equivalently to the predicate devices for the stated uses.
    • Reported Device Performance: The document states that "Basic system operation and performance are unchanged from the cleared LX-20 Laser System Family." The modified LX-20 shares the same RF excited lasing tube, main chassis, power supply, safety systems, microprocessor controller, and much of the same electronics. The primary modification is the addition of a Sharplan articulated arm, which the submitter believes "do not raise any new issues of safety and effectiveness."

    The following information cannot be provided as no new clinical data was presented or a study described in this 510(k) submission:

    • 2. Sample sized used for the test set and the data provenance
    • 3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
    • 4. Adjudication method for the test set
    • 5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    • 6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
    • 7. The type of ground truth used
    • 8. The sample size for the training set
    • 9. How the ground truth for the training set was established

    Summary of Device Information Presented:

    • Device Name: Luxar modified LX-20 C0, Surgical Laser System
    • Intended Use: Vaporization, incision, excision, ablation, or photocoagulation of soft tissue in various surgical specialties (Gynecology, Laparoscopic Surgery, Dermatology, Dental and Oral surgery, Orthopedic, General Surgery, Otorhinolaryngology, Podiatry).
    • Basis for Clearance: Substantial equivalence to the Luxar LX-20 C0, Surgical Laser System Family (K960475) and Sharplan 20C C02 Laser (K963229 and K935563).
    • Key Modification: Addition of the Sharplan articulated arm.
    • Performance Claim: "Basic system operation and performance are unchanged from the cleared LX-20 Laser System Family." No new clinical data was presented to support new performance claims or new indications for use.