510(k) Data Aggregation

    K Number
    K221281

    Validate with FDA (Live)

    Device Name
    Multitom Rax
    Date Cleared
    2022-11-17

    (198 days)

    Product Code
    Regulation Number
    892.1650
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K180727

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Multitom Rax is a device intended to visualize anatomical structures by converting an X-ray pattern into a visible image. The system has medical applications ranging from gastrointestinations to cranial, skeletal, thoracic and lung exposures as well as examinations of the urogenital tract. The unit may also be used in emergency applications, lymphography, endoscopy, myelography, arthrography, interventional radiology, digital angiography, and digital subtraction angiography (DSA). The system may be used on pediatric, adult, and bariatric patients.

    The True2scale Body Scan functionality (i.e., slot-scanning-based acquisition and reconstruction technique) of the Multitom Rax is intended to be used for the genetrically accurate (in scanning direction) 2-D representation of the spine, the lower limbs or the full body which may be used for the assessment of body axes and skeletal alignment. The True2scale Body Scan is not intended to be used for interventional purposes.

    The Real3D functionality (i.e., cone-beam CT acquisition and reconstruction technique) of the Multitom Rax is intended to be used for 3-D bone imaging of the head, the upper and lower extremities as well as the lumbar spine. Real3D is not intended for imaging of the torso of patients with a Body Mass Index (BMI) exceeding 30 kg/m².

    Multitom Rax is not for mammography examinations.

    Device Description

    Multitom Rax is a stationary X-ray system for radiography and fluoroscopy. Multitom Rax consists of a floor mounted patient table (option) and ceiling suspended X-ray tube, and a ceiling suspended Solid State X-ray Imager (SSXI). Together with an X-ray generator and a digital imaging system, Multitom Rax provides comprehensive image acquisition modes to support radiographic and fluoroscopic imaging procedures.

    With the True2scale Body Scan technology, Multitom Rax performs a continuous scan that moves along the patient's vertical axis with a highly collimated radiation beam along a line trajectory using the system's two telescopic arms. The projections, which are acquired during the scanning process, form the basis for a reconstruction to obtain a 2D representation of the scanned object.

    With the Real3D technology, Multitom Rax performs a continuous, circular scan around the patient using the system's two telescopic arms. The projections, which are acquired during the scanning process, form the basis for a reconstruction to obtain a 3D representation of the scanned object.

    AI/ML Overview

    The Siemens Multitom Rax device's Real3D functionality (cone-beam CT) was evaluated by comparing its technological characteristics and performance to a legally marketed predicate device (Multitom Rax with True2scale Body Scan Option) and a reference device (CurveBeam LineUP).

    Here's a breakdown of the acceptance criteria and study information:

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided document doesn't explicitly state "acceptance criteria" in a separate section with numerical targets for each performance metric. Instead, the comparison to the reference device (CurveBeam LineUP) serves as the benchmark to demonstrate performance is at least equivalent or better, especially for the newly added CBCT functionality. The acceptance criteria can be inferred from the comparison table where the subject device's performance is listed against the reference device.

    FeatureReference Device (CurveBeam LineUP) PerformanceSubject Device (Multitom Rax Real3D) PerformanceComment / Implied Acceptance
    kVp100 - 12060 - 130Better for Multitom Rax Real3D (Wider range of kVp, implying flexibility and potentially better image quality for diverse patient types and body regions).
    Voxel size0.3 mm0.2 mm - 0.5 mm (depending on chosen reconstruction kernel)Better for Multitom Rax Real3D (Ability to achieve smaller voxel size, indicating higher spatial resolution).
    Slice spacing0.3 mm0.2 mm - 0.5 mm (depending on chosen reconstruction kernel)Better for Multitom Rax Real3D (Ability to achieve smaller slice spacing).
    FOV (diameter, height)Regular: 20 cm x 20 cm (d, h) Extended: 35 cm x 20 cm (d, h)Real 3D Hi-Res: 15 cm x 15 cm (d, h) Real3D: 23 cm x 23 cm (d, h)Not directly comparable, but Multitom Rax Real3D has a larger regular FOV. Extended FOV not available for Multitom Rax, but its regular FOV is larger than the reference's regular FOV. This indicates suitability for diverse anatomical regions.
    Scan time*23s or 26sReal3D Hi-Res: 14s Real3D: 12s or 16s (depending on anatomy)Better for Multitom Rax Real3D and Real3D Hi-Res (Shorter scan times, reducing patient motion artifacts and patient dose).
    High-contrast resolution (10% MTF)12 lp/cmReal 3D Hi-Res: up to 25 lp/cm (very sharp kernel) Real 3D: up to 15 lp/cm (sharp kernel)Better for Multitom Rax Real3D (Significantly higher line pairs per centimeter, indicating superior ability to resolve fine details).
    Low-contrast detectabilityn/a20 HU @ 4 mm (smooth kernel) 10 HU @ 8 mm (smooth kernel)Not reported for CurveBeam LineUP. Justification for adequacy: Intended use is high-contrast bone imaging, so low-contrast detectability is not as critical as for hemorrhage detection. The reported values are therefore considered acceptable for the intended use.
    Slice Sensitivity Profile / z-axis point spread functionNot directly reported (isotropic voxels assumed)0.42 mm ± 0.1 mm (Real3D) 0.31 mm ± 0.1 mm (Real 3D Hi-Res)Not reported for CurveBeam LineUP. Justification for adequacy: Isotropic resolution for Multitom Rax Real3D is stated, implying consistent resolution in all directions, which is a desirable characteristic.
    Image noisen/aSmooth: 20 ± 15 HU Medium: 60 ± 40 HU Sharp: 100 ± 60 HU Very sharp: 300 ± 150 HUNot reported for CurveBeam LineUP. Justification for adequacy: Noise depends on dose, object, and reconstruction kernel, making direct comparison difficult. The reported values are considered acceptable for the intended diagnostic quality of high-contrast bone imaging.
    Uniformity (in-plane)< 100 HU< 150 HUBetter for CurveBeam LineUP. Justification for adequacy: Despite being higher, the uniformity of <150 HU is considered acceptable as it allows for standard viewing windowing functions typical for bone imaging (e.g., 2000 HU / 300 HU or 1500 HU / 450HU).
    CT Number AccuracyAir: -1000 ± 200 HU Water: 0 ± 150 HU Bone: n/aAir: -1000 ± 250 HU Water: 0 ± 150 HU Bone: 450 ± 150 HUAir: Better for CurveBeam LineUp. Water: Equivalent. Bone: Not reported for CurveBeam LineUp. Justification for adequacy: The CT number accuracy for Multitom Rax Real3D, although slightly wider for air, is still within ranges that allow for standard bone viewing windowing functions and is therefore considered adequate for its intended high-contrast bone imaging use.

    2. Sample Size Used for the Test Set and Data Provenance

    The document mentions an "image quality evaluation of 21 anonymized clinical and phantom data sets."

    • Sample size: 21 data sets (comprising clinical and phantom data).
    • Data provenance: Not explicitly stated (e.g., country of origin, retrospective or prospective). It simply mentions "anonymized clinical and phantom data sets."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    The image quality evaluation was conducted by "expert US board-certified radiologists."

    • Number of experts: Not explicitly stated, but implies a group of experts plural.
    • Qualifications of experts: US board-certified radiologists. No specific years of experience are mentioned.

    4. Adjudication Method for the Test Set

    The document does not describe a formal adjudication method (e.g., 2+1, 3+1). It states the image quality evaluation was conducted by experts "showing that presented 3D images are of sufficient diagnostic quality to assess osseous structures including fractures and bone angles." This suggests a consensus or individual assessment against diagnostic quality, rather than a specific algorithmic adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done

    No, the document does not describe an MRMC comparative effectiveness study that assesses how much human readers improve with AI vs. without AI assistance. The study described is an image quality evaluation by radiologists, not a comparative effectiveness study involving AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Yes, standalone performance was evaluated through the non-clinical tests and the comparison of technological characteristics against a reference device. These tests assessed the intrinsic image quality metrics (high-contrast resolution, low-contrast detectability, CT number accuracy, uniformity, image noise, etc.) of the Real3D functionality without human intervention in the diagnostic process.

    7. The Type of Ground Truth Used

    For the non-clinical performance metrics (e.g., resolution, uniformity, CT number accuracy), the ground truth is established through phantom data and standardized measurement techniques. For the "clinical" aspects of the 21 data sets, the ground truth for diagnostic quality assessment was the expert consensus/opinion of US board-certified radiologists who determined if the images were of "sufficient diagnostic quality to assess osseous structures including fractures and bone angles."

    8. The Sample Size for the Training Set

    The document does not provide information on the sample size used for the training set. The descriptions focus on the validation and verification of software and the performance evaluation of the Real3D functionality.

    9. How the Ground Truth for the Training Set Was Established

    As the document does not provide information on the training set, the method for establishing its ground truth is also not provided.

    Ask a Question

    Ask a specific question about this device

    K Number
    K203187

    Validate with FDA (Live)

    Device Name
    HiRise
    Manufacturer
    Date Cleared
    2020-11-18

    (22 days)

    Product Code
    Regulation Number
    892.1750
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K180727

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The HiRise is intended to be used for 3-D imaging of the upper extremities and pelvis of adult and pediatric patients weighing from 40 to 450 lbs.

    The device is to be operated in a professional healthcare environment by qualified health care professionals only.

    Device Description

    The HiRise is a Cone Beam Computed Tomography Imaging Device that acquires 360-degree rotational projection sequences which are reconstructed into 3D volumetric images of the examined anatomical region. The device uses a gantry assembly, which is comprised of an X- ray source, image detector, and a motorized gantry. The gantry facilitates the acquisition of a full X-ray projection sequence by the acquisition software. For non-weight bearing scans of the lower extremity, a patient positioner accessory allows the patient to sit into a position where he/she can comfortably place his/her anatomy into the imaging bore.

    The gantry assembly is mounted on vertical actuators and can travel vertically to capture weight-bearing anatomy at various heights ranging from the feet to the pelvis regions. The HiRise provides total vertical travel of 37 inches to accommodate patients of various sizes. Images produced by the HiRise can be sent electronically to a DICOM complaint image viewing software.

    AI/ML Overview

    The provided text describes the HiRise, a Cone Beam Computed Tomography (CBCT) X-ray system, and states that it has been determined substantially equivalent to its predicate device, the CurveBeam LineUP.

    Here's an analysis of the acceptance criteria and the study information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria for the HiRise device are primarily established through its demonstrated substantial equivalence to the predicate device, the CurveBeam LineUP. The reported device performance is presented in the context of this comparison and in studies confirming diagnostic quality and safety.

    Feature / Criteria (Derived from comparison to Predicate)Acceptance Criteria (Implied by Predicate Performance)Reported Device Performance (HiRise)
    Indications for Use3-D imaging of foot, knee, hand, elbow.Expands to 3-D imaging of the upper extremities and pelvis of adult and pediatric patients weighing from 40 to 450 lbs. Performance: Datasets of the humerus, elbow, forearm, hand, wrist, pelvis/hip, femur, knee, shin (lower leg or tib/fib) and foot/ankle were reviewed by a board-certified radiologist and found to be of diagnostic quality.
    Patient Weight Range50 lbs to 400 lbsExpands to 40 lbs to 450 lbs. Performance: The increased weight range has been tested and verified by third-party 60601-1 testing.
    Scan AxisHorizontal and verticalHorizontal and vertical Performance: Image sequences captured utilizing the gantry in vertical scanning mode were included in the datasets sent to the board-certified radiologist and found to be of diagnostic quality.
    Tube Voltage (CT scans)100-120 kVp100-130 kVp. Performance: Bench testing determined optimal X-Ray tube voltage for each anatomy and patient size. Higher kVp was determined to be required to clinically image the new anatomy (hips and pelvis).
    Tube Current5 mA5.5 or 6.5 mA. Performance: Increased tube current was required to provide diagnostic quality image sequences in the new anatomy (hips and pelvis).
    Scan Time (CT)21 sec26 sec. Performance: HiRise is slightly slower to allow for greater exposure time required for the denser anatomy. Image quality performance was verified with Bench Testing.
    Image DetectorCMOS flat panelAmorphous Silicon flat panel. Performance: Detector performance testing verified image quality met requirements. Performance testing demonstrated that the image quality of the amorphous silicon flat panel is statistically equivalent to that of the predicate.
    3D Imaging Volume20cm (high) x 35 cm (diameter)Large FOV: 8" (20cm) height x 16" (40cm) diameter; Medium FOV: 8" (20cm) height x 10" (25cm) diameter. Performance: Image sequences captured utilizing both volumes were included in the datasets sent to the board-certified radiologist and found to be of diagnostic quality.
    Typical Resolution0.3 mm voxelLFOV: 0.3mm, MFOV: 0.25mm. Performance: Image sequences captured utilizing both volumes, and subsequent resolutions, were included in the datasets sent to the board-certified radiologist and found to be of diagnostic quality.
    Image Quality (Overall)Diagnostic quality (Implied by predicate)Performance: Image quality phantoms were scanned in the HiRise and evaluated by a medical physicist. The scans were reviewed by a radiologist and found to be of diagnostic quality. Clinical review of images by a radiologist indicated that HiRise is safe and effective when used as labeled.
    Safety and EffectivenessCompliance with regulations and standardsPerformance: Complies with applicable FDA and international standards pertaining to electrical, mechanical, software, EMC, and radiation safety of medical devices (e.g., AAMI ES60601-1, IEC 60601-1-3, IEC 62366, IEC 62304, IEC 60601-2-44, IEC 60601-1-2, IEC 61223-3-5, NEMA PS 3.1-3.20, IEC 60825-1).

    2. Sample size used for the test set and the data provenance

    The document does not specify a distinct "test set" in terms of patient cases for a statistical performance study comparing the HiRise to a ground truth or predicate quantitatively. Instead, it relies on two primary methods:

    • Phantom Scans: "image quality phantoms were scanned in the HiRise and evaluated by a medical physicist." The sample size of phantoms is not specified.
    • Clinical Image Review: "datasets of the humerus, elbow, forearm, hand, wrist, pelvis/hip, femur, knee, shin (lower leg or tib/fib) and foot/ankle were reviewed by a board-certified radiologist and found to be of diagnostic quality." The number of patient cases (datasets) reviewed is not specified.
      The data provenance is not explicitly stated (e.g., country of origin, retrospective or prospective). However, the "clinical review of images" suggests actual patient data, likely retrospective.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of experts: At least one board-certified radiologist.
    • Qualifications: "board-certified radiologist." Specific years of experience are not mentioned.
    • Additionally, a "medical physicist" evaluated image quality phantoms.

    4. Adjudication method

    The adjudication method for the clinical image review is not explicitly described. It states that "a board-certified radiologist... found [images] to be of diagnostic quality." This implies a single expert's assessment without mentioning a consensus process or multiple readers.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done

    No, a multi-reader multi-case (MRMC) comparative effectiveness study comparing human readers with AI assistance versus without AI assistance was not conducted or described. The HiRise device is a Computed Tomography X-Ray System, which directly acquires images, and the provided documentation focuses on its imaging performance versus a predicate device, not on AI-assisted interpretation.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Yes, an assessment of the device's standalone performance was done. The "performance testing by a medical physicist" and "clinical review of images by a radiologist" evaluating the HiRise images themselves indicate a standalone assessment of the device's output quality. There's no mention of a human-in-the-loop component being evaluated for the device's image acquisition functionality.

    7. The type of ground truth used

    The ground truth for evaluating the HiRise's performance was established through:

    • Expert Consensus/Opinion: For clinical images, it was the "diagnostic quality" determined by a "board-certified radiologist."
    • Bench Testing/Phantom Standards: For image quality phantoms, evaluation by a "medical physicist" against established image quality requirements, and verification of "optimal X-Ray tube voltage" and "increased tube current" through bench testing. Additionally, "Detector performance testing" verified image quality met requirements.

    8. The sample size for the training set

    The document describes the HiRise as an imaging device (hardware and associated software for image acquisition and reconstruction), not a machine learning or AI algorithm in the context of image interpretation. Therefore, there is no "training set" for an AI model mentioned in this submission. The "training set" concept is not applicable here as the device's functionality doesn't appear to be based on a trained AI for image analysis.

    9. How the ground truth for the training set was established

    As there is no "training set" for an AI model mentioned, this question is not applicable based on the provided text.