510(k) Data Aggregation

    K Number
    K252974

    Validate with FDA (Live)

    Device Name
    EMPOWR Knee
    Manufacturer
    Date Cleared
    2025-12-19

    (93 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K173890, K172524

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When a mechanical alignment approach is utilized, these devices are indicated for patients suffering from disability due to:

    • degenerative, post-traumatic or rheumatoid arthritis;
    • avascular necrosis of the femoral condyle;
    • post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy;
    • moderate valgus, varus or flexion deformities;
    • treatment of fractures that are unmanageable using other techniques.

    These devices may also be indicated in the salvage of previously failed surgical attempts.

    When the EMPOWR® Dynamic Natural Alignment (DNA) approach is utilized, these devices are indicated for patients with disability due to:

    • degenerative, post-traumatic or rheumatoid arthritis;
    • avascular necrosis of the femoral condyle;
    • moderate valgus, varus or flexion deformities.

    All EMPOWR devices except for the EMPOWR Revision Knee™, EMPOWR PS Knee™, and EMPOWR Partial Knee™ may be implanted using the EMPOWR® Dynamic Natural Alignment (DNA) surgical technique.

    All devices are intended for cemented applications except for the EMPOWR Porous® Knee Femur, EMPOWR Porous® Knee Tibia, and Porous Patella which are intended for cementless applications.

    While knee replacements are not intended to withstand activity levels and loads of normal healthy bone, they are a means of restoring mobility and reducing pain for many patients.

    Enovis™ knee devices are intended for treatment of patients who are candidates for knee arthroplasty per the Indication for use. While total knee replacements are not intended to withstand activity levels and loads of normal healthy bone, they are a means of restoring mobility and reducing pain for many patients.

    Device Description

    The purpose of this submission is to obtain clearance for the EMPOWR® Dynamic Natural Alignment (DNA) surgical technique. The proposed technique is a kinematic alignment (KA) strategy, providing an alternative alignment approach to the current mechanical alignment (MA) strategy. The purpose of the KA technique is to restore normal knee function by preserving the patient's native joint line. The technique may be used to implant all EMPOWR devices except for the EMPOWR Revision Knee™ and the EMPOWR PS Knee™. This is a labeling change only. No design changes are being introduced to the implant systems.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K222566

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-10-17

    (54 days)

    Product Code
    Regulation Number
    888.3565
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K172524

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When a mechanical alignment approach is utilized, this device is indicated for patients with severe knee pain and disability due to:

    • Rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis
    • Collagen disorders, and/or avascular necrosis of the femoral condyle
    • Post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy
    • Moderate valgus, varus, or flexion deformities
    • The salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery.

    When a kinematic alignment approach is utilized, this device is indicated for patients with severe knee pain and disability due to:

    • Rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis
    • Collagen disorders, and/or avascular necrosis of the femoral condyle.
    • Moderate valgus, varus, or flexion deformities.
      The kinematic alignment (KA) surgical technique may only be used with Persona CR femoral components, Persona CR or UC articular surface components, and cemented nonporous Persona tibial components without a stem extension.

    Porous coated components may be used cemented or uncemented (biological fixation). All other femoral, tibial baseplate, and all-polyethylene (UHMWPE and VEHXPE) patella components are indicated for cemented use only.

    Device Description

    Zimmer Inc Persona Personalized Knee System offers Vivacit-E polyethylene components that are sterile packaged with a shelf life of 5 years. The purpose of this submission is to extend the shelf life of these polyethylene components by re-packaging and re-sterilizing unexpired product and product expired up to 3 months post-expiration date. The rework of these devices to extend the shelf life by an additional 5 years does not change the intended use or fundamental scientific technology of the device.

    AI/ML Overview

    Based on the provided text, the submission is for extending the shelf life of an existing medical device, the Zimmer Persona Personalized Knee System. It is not a submission for a new AI/ML-driven medical device, and therefore, the document does not contain information about acceptance criteria or a study proving an AI/ML device meets those criteria.

    The text focuses on non-clinical data related to:

    1. Shelf life extension of the Vivacit-E polyethylene components after ethylene oxide re-sterilization.
    2. Biological safety assessment of the re-sterilized components.

    The "Summary of Performance Data (Nonclinical and/or Clinical)" section explicitly states that the listed items are "Non-Clinical Tests." There is no mention of a comparative effectiveness study involving human readers with and without AI assistance, or any standalone algorithm performance testing, or the use of experts to establish ground truth for a test set.

    Therefore, I cannot fulfill your request to describe acceptance criteria and a study proving an AI/ML device meets those criteria, as the provided document pertains to a resubmission for a non-AI/ML device's shelf-life extension.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201343

    Validate with FDA (Live)

    Date Cleared
    2020-07-10

    (51 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K172524, K173890, K193515

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    General Total Knee Arthroplasty (TKR) Indications:

    · Painful, disabling joint disease of the knee resulting from: noninflammatory degenerative joint disease (including osteoarthritis, traumatic arthritis, or avascular necrosis), rheumatoid arthritis or post-traumatic arthritis.

    · Post-traumatic loss of knee joint configuration and function.

    · Moderate varus, valgus, or flexion deformity in which the ligamentous structures can be returned to adequate function and stability.

    · Revision of previous unsuccessful knee replacement or other procedure.

    · Fracture of the distal femur and/or proximal tibia that cannot be standard fracture-management techniques.

    The Triathlon Tritanium Tibial Baseplate and Tritanium Metal-Backed Patella components are indicated for both uncemented and cemented use.

    The Triathlon Total Knee System beaded with Peri-Apatite components are intended for uncemented use only.

    The Triathlon All Polyethylene tibial components are indicated for cemented use only.

    Additional Indications for Posterior Stabilized (PS) Components:

    • · Ligamentous instability requiring implant bearing surface geometries with increased constraint.
    • · Absent or non-functioning posterior cruciate ligament.
    • · Severe anteroposterior instability of the knee joint.
    Device Description

    This submission covers Mako Total Knee Application-compatible components of the Triathlon® Total Knee System intended for use with the Mako System during a total knee arthroplasty. These include cruciate-retaining (CR), condylar stabilized (CS) and posterior stabilized (PS) components, tibial baseplates and TS tibial inserts. Triathlon® Total Knee System PSR tibial inserts are being reviewed for compatibility with the Mako Total Knee Application under K193515. The Triathlon® Total Knee System components have been previously cleared in prior 510(k) submissions and are commercially available. The Mako Total Knee Application-compatible Triathlon® Total Knee System components are manufactured from the following materials: Cobalt Chromium Alloy, Titanium Alloy, Commercially Pure Titanium, Ultra-High Molecular Weight Polyethylene and Calcium Phosphate.

    AI/ML Overview

    This FDA 510(k) summary for the Triathlon® Total Knee System (K201343) does not describe a study involving an AI/CADe device and therefore does not include the requested information about acceptance criteria or a study proving device performance against such criteria in the context of AI.

    The submission is for the addition of an individualized alignment preoperative planning methodology for the Triathlon® Total Knee System components used in conjunction with the Mako System during total knee arthroplasty. The Mako System itself (a robotic arm assisted surgery system) is not the subject of this 510(k), but rather the specific set of knee replacement components compatible with its planning application.

    The document indicates that:

    • The Triathlon® Total Knee System components have been previously cleared.
    • This submission focuses on compatibility and an individualized alignment preoperative planning method for these components.
    • Non-clinical laboratory assessments were previously performed on the components.
    • Clinical testing was not required as a basis for substantial equivalence for this specific submission.

    Therefore, I cannot provide the requested information. The document explicitly states "Clinical testing is not required as a basis for substantial equivalence," meaning no new clinical study was conducted for this specific submission to demonstrate performance against acceptance criteria for an AI or CADe device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K173890

    Validate with FDA (Live)

    Date Cleared
    2018-08-23

    (245 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K172524

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Evolis®/GMK® knee prosthesis is designed for cemented use in total knee arthroplasty, if there is evidence of sufficient sound bone to seat and support the components.

    This knee replacement system is indicated in the following cases:

    • · Severely painful and/or disabled joint as a result of arthritis, traumatoid arthritis, theumatoid arthritis.
    • · Avascular necrosis of femoral condyle.
    • · Post traumatic loss of joint configuration.
    • · Primary implantation failure.

    GMK Sphere can be implanted using a kinematic alignment approach. When a kinematic alignment approach is utilized, this knee replacement system is indicated in the following cases:

    • · Severely painful and/or disabled joint as a result of arthritis, traumatoid arthritis or polyarthritis.
    • · Collagen disorders, and/or avascular necrosis of the femoral condyle.
    • · Moderate valgus, varus, or flexion deformities.

    Tibial wedges cemented are to be attached to the tibial baseplate with both the fixing cylinders and bone cement. The screwed tibial augments are for screwed fixation to the tibial baseplate.

    In case a semi-constrained liner is used, an extension stem must be implanted both on the femoral components.

    In case a GMK Revision tibial tray is used, an extension stem must be implanted.

    Device Description

    The purpose of this submission is to gain clearance for the GMK Sphere – Kinematic Alignment surgical technique and the technique specific instruments. The proposed kinematic alignment technique is an alternative alignment strategy to the traditional mechanical alignment used for total knee arthroplasty. The purpose of the kinematic alignment technique is to restore normal knee function by aligning the distal and posterior femoral joint lines of the tibial component to those of the normal or pre-arthritic state.

    The GMK Sphere - Kinematic Alignment surgical technique will be used with the following components of the GMK Sphere System cleared under K121416, K140826, and K162035:

    • o Tibial Insert Fixed Flex: Left and Right, Sizes 1 - 6, 10 - 20 mm (including intermediate sizes 11 mm and 12 mm), UHMWPE Type 1, Fixation Screw: Ti6Al4V;
    • Femoral Component Left and Right, Sizes 1 7, Co-Cr-Mo; ●
    • Femoral Component Left and Right, Sizes 1+ 6+ (intermediate sizes), Co-Cr-Mo; ●
    • Tibial Tray Fixed Cemented Left and Right, 4 intermediate sizes, Co-Cr-Mo; ●
    • o Tibial Insert Fixed Flex, Left and Right, Sizes 1 - 6, 10 mm - 20 mm, UHMWPE Type 1, Ti6Al4V:
    • o Tibial Insert Fixed Flex, Left and Right, Sizes 1 - 6, 11 mm and 13 mm, UHMWPE Type 1. Ti6Al4V: and
    • instrumentation. ●
    AI/ML Overview

    This document is a 510(k) premarket notification for the "GMK Sphere - Kinematic Alignment" knee replacement system. It primarily focuses on demonstrating substantial equivalence to previously cleared predicate devices, particularly concerning the introduction of a new kinematic alignment surgical technique and associated instruments.

    Based on the provided text, the device itself is a "Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis." The study described is a demonstration of substantial equivalence rather than a study proving the device meets clinical acceptance criteria through, for example, a clinical trial or a study assessing AI performance.

    Therefore, the information requested in the prompt, especially concerning AI performance metrics, expert roles, and multi-reader multi-case studies, is not applicable to the content of this 510(k) submission.

    However, I can extract information related to the engineering and mechanical performance testing of the device, which aligns with device acceptance criteria for a physical medical device.

    Here's an interpretation based on the provided document:

    Study Type: This is a 510(k) Premarket Notification, which aims to demonstrate substantial equivalence to legally marketed predicate devices, not specifically to prove AI performance or the effect of AI assistance on human readers. The "study" described is a series of non-clinical, benchtop and cadaveric performance tests to ensure the new surgical technique and instruments maintain the safety and effectiveness of the existing GMK Sphere system.

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document mentions that "verification activities, as identified through risk analysis, were conducted to written protocols with pre-defined acceptance criteria." However, the specific numerical acceptance criteria and the detailed reported performance values are not provided in this summary document. Only the types of tests performed are listed.

    Acceptance Criterion (Type of Test)Reported Device Performance (Summary from document)
    Mechanical resistance of the femoral component under physiological static and dynamic loadsDemonstrated to support substantial equivalence. (Implied: met pre-defined acceptance criteria, but specific values not reported in this summary).
    Wear behaviorDemonstrated to support substantial equivalence. (Implied: met pre-defined acceptance criteria, but specific values not reported in this summary).
    Range of motion (ROM)Tested for both predicate and subject devices. (Implied: results were consistent with predicate, met pre-defined acceptance criteria, but specific values not reported in this summary).
    Mechanical resistance of the tibial tray under physiological static and dynamic loadsDemonstrated to support substantial equivalence. (Implied: met pre-defined acceptance criteria, but specific values not reported in this summary).
    Sterilization validationDemonstrated to support substantial equivalence. (Implied: met pre-defined acceptance criteria, but specific values not reported in this summary).
    Shelf lifeDemonstrated to support substantial equivalence. (Implied: met pre-defined acceptance criteria, but specific values not reported in this summary).
    PyrogenicityDemonstrated to support substantial equivalence. (Implied: met pre-defined acceptance criteria, but specific values not reported in this summary).
    Expected LoadsTested for subject devices. (Implied: met pre-defined acceptance criteria, but specific values not reported in this summary).
    Level of ConstraintsTested for subject devices. (Implied: met pre-defined acceptance criteria, but specific values not reported in this summary).
    Primary and Secondary FixationTested for subject devices. (Implied: met pre-defined acceptance criteria, but specific values not reported in this summary).
    Cadaveric workshop for validation of the surgical technique and the relative dedicated instruments setConducted. (Implied: validated the technique and instruments).

    2. Sample Size Used for the Test Set and Data Provenance:

    • Sample Size: The document does not specify the numerical sample sizes for the various mechanical and cadaveric tests (e.g., number of components tested, number of cadavers used). It refers to "verification activities... conducted to written protocols."
    • Data Provenance: The tests are described as non-clinical (benchtop) and cadaveric, meaning they are laboratory or ex-vivo studies. The document does not provide information about the country of origin of the data beyond implicitly being part of Medacta's internal R&D process (Medacta International SA is based in Switzerland). The data is prospective in the sense that these tests were conducted specifically for this submission.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications:

    This concept, as it relates to expert review of medical images for ground truth, is not applicable to this type of device and submission. The "ground truth" for mechanical and cadaveric tests would be established by the physical and engineering properties of the materials and the biomechanical behavior observed, measured against engineering standards and specifications. There's no mention of interpreting visual data by human experts for this purpose.

    4. Adjudication Method for the Test Set:

    Not applicable in the context of expert consensus for imaging or clinical outcomes. Test results are likely adjudicated against pre-defined engineering specifications and standards, not through a human consensus process.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done:

    No. This type of study (MRMC) is relevant for AI-powered diagnostic devices where human readers interpret medical images. This 510(k) is for a physical knee implant and surgical technique, not an AI product assisting in diagnosis.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    No. This concept applies to AI algorithms. The "device" here is a physical implant and surgical instruments.

    7. The Type of Ground Truth Used:

    The "ground truth" for these tests are:

    • Engineering Specifications/Standards: Performance measured against established industry standards and internal design specifications for mechanical properties (e.g., strength, wear, range of motion).
    • Biomechanical Principles: For cadaveric studies, the "ground truth" is the observed anatomical and biomechanical response of the tissues and device under simulated physiological conditions.

    8. The Sample Size for the Training Set:

    Not applicable. There is no "training set" in the context of an AI algorithm described here. The development of the device (implant and technique) is based on engineering design, material science, and prior surgical experience, not machine learning from a dataset.

    9. How the Ground Truth for the Training Set was Established:

    Not applicable. As there is no training set for an AI algorithm, this question is not relevant to the provided document.