510(k) Data Aggregation

    K Number
    K252582

    Validate with FDA (Live)

    Date Cleared
    2025-11-18

    (95 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K083192, K160979, K193401, K113779, K153268, K152509

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Inclusive® Titanium Abutments are premanufactured prosthetic components connected to endosseous dental implants in edentulous or partially edentulous maxilla or mandible to provide support for cement-retained or screw-retained prosthetic restorations. All digitally designed abutments for use with Inclusive® Titanium Abutments for CAD/CAM are intended to be sent to a Prismatik Dentalcraft validated milling center for manufacture.

    Compatible Implant Systems: Camlog® CONELOG®, Dentium® NR Line

    Compatible Implant Fixtures:
    Camlog® CONELOG®: 3.3 mm/3.3 mm, 3.8 mm/3.8 mm, 4.3 mm/4.3 mm, 5.0 mm/5.0 mm
    Dentium® NR Line: 3.1 mm/3.2 mm, 3.6 mm

    Device Description

    Inclusive® Titanium Abutments are premanufactured prosthetic components directly connected to endosseous dental implants and are intended for use as an aid in prosthetic rehabilitation. Inclusive® Titanium Abutments are designed and fabricated to be compatible with Camlog® CONELOG® and Dentium® NR Line Implant Systems. The products are made from titanium alloy Ti-6Al-4V ELI, which meets ASTM F136-13(2021), Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications (UNS R56401). They include Inclusive® Titanium Abutment Blanks intended to be used to fabricate one-piece, all-titanium, patient-specific abutments using CAD/CAM technology and Inclusive® Titanium Abutments 4.5mmH and 6mmH intended to be used for support of fabricated crowns/bridges or a zirconia coping to complete the two-piece abutment. The zirconium coping intended for use with the Inclusive® Titanium Abutments 4.5mmH and 6mmH devices are made from zirconium oxide ceramic, conforming to ISO 13356 Implants for surgery – Ceramic materials based on yttria-stabilized tetragonal zirconia (Y-TZP). Inclusive® Titanium Abutments 4.5mmH and 6mmH devices are a two-piece abutment with a titanium base and a ceramic top-half which when cemented together (Shofu MonoCem K020481) constitutes the final finished abutment. Each patient-specific abutment is prescribed by a clinician and manufactured by an authorized milling center validated by Prismatik Dentalcraft Inc. Inclusive® Titanium Abutments are provided non-sterile and intended for single use and prescription use.

    Inclusive® Multi-Unit Coping is manufactured from titanium alloy, Ti-6Al-4V ELI conforming to ASTM F136-13(2021) and used in conjunction with the Camlog® CONELOG® and Dentium® NR Line multi-unit abutments. Inclusive® Multi-Unit Coping is bonded with the dental restoration prior to being seated on the multi-unit abutment via a multi-unit prosthetic screw. The non-engaging configuration of the multi-unit coping does not have an internal connection feature and seats onto the flat mating surface of the multi-unit abutment. The multi-unit coping is used in combination with screw-retained multi-unit dental prosthetics, e.g. bridges and bars, which are used to reconstruct the function and aesthetics of lost teeth. The multi-unit coping is straight with no angle correction and provided non-sterile. The device is intended for singe use and prescription use.

    The design parameters for the Titanium Abutment Blanks are:

    • the minimum wall thickness is no less than 0.5 mm.
    • the gingival margin diameter is no less than 0.5 mm wider than implant.
    • maximum angle correction is no greater than 30°. *
    • minimum margin height is no less than 0.5 mm.
    • maximum gingival height is no greater than 6 mm, and
    • minimum post height above the gingival collar is no less than 4.0 mm.

    *Angulation up to 30° for Titanium Abutment Blanks only allowed for compatible implant bodies of Camlog® CONELOG® Ø3.3mm Implants and Dentium® NR Line Ø3.1mm Implants for anterior use in the mouth under single-unit loading.

    Inclusive® Titanium Abutments Blanks compatible with Camlog® CONELOG® Ø3.8mm, Ø4.3mm, and Ø5.0mm Implants are not to be used as angled abutments in the posterior region.

    The design parameters for the zirconia coping for the Titanium Abutment 4.5mmH and 6mmH are:

    • the minimum wall thickness is no less than 0.5mm.
    • the gingival margin diameter is no less than 0.5 mm wider than implant.
    • no angulation correction, straight (0°) only.
    • minimum margin height is no less than 0.5 mm.
    • maximum gingival height is no greater than 6 mm, and
    • minimum post height above the gingival collar is no less than 4.0 mm.
    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K212702

    Validate with FDA (Live)

    Date Cleared
    2022-10-13

    (413 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K192436, K161689, K182091, K120847, K152509

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The IM/ST Fixture System is indicated for use in partially or fully edentulous mandibles and maxillae, in support of single or multiple-unit restorations including; cemented retained, or overdenture restorations, and final or temporary abutment support for fixed bridgework. It is intended for delayed loading.

    Device Description

    The proposed device, IM/ST Fixture System, is indicated for use in partially or fully edentulous mandibles and maxillae, in support of single or multiple-unit restorations including; cemented retained, screw retained, or overdenture restorations, and final or temporary abutment support for fixed bridgework. It is intended for delayed loading.

    Implant system contain dental implant and abutment. The dental implant system, IM Implant System and ST Implant System, both of which are divided into mini implant and regular implant. IM Implant and ST Implant have different designs for the external thread section. The external thread part of IM implant is composed of conical shape, double thread and spiral groove, while The external thread part of ST implant is composed of conical shape, single thread, neck micro thread and cutting groove. Both IM implant and ST implant are available in diameters of 3.75, 4.2, 4.6 and 5.05mm and lengths of 7, 8.5, 10, 11.5, 13 and 15mm, and both are bone level. The "mini" and "regular" differ in size, but abutments are cross-compatible with both IM and ST implant types, and the abutment is attached to the implant by abutment screw and fastened to the implant. The material of abutment screw is Titanium Alloy (Ti-6A1-4V, ASTM F136).

    The implants are bone level. The implants were made of Pure Titanium Grade 4 and underwent sandblasting and acid etching process. Modified surface testing (SEM/EDS) for blasted/etched surfaces was conducted to demonstrate removal of particles and chemicals from implant surface.

    Abutment can be divided into healing abutment, straight abutment, multi-abutment, multi-angled abutment and temporary abutment. And it is divided into mini abutment and regular abutment. In addition, abutment also has three types of cylinder, angled cylinder and temporary cylinder.

    AI/ML Overview

    The provided document is a 510(k) summary for the Guilin FiTeeth Medical Instrument Co., Ltd. IM/ST Fixture System. It describes the device and its comparison to predicate and reference devices to demonstrate substantial equivalence, rather than establishing acceptance criteria and proving performance against them through a clinical study with detailed metrics like sensitivity, specificity, or AUC.

    Therefore, the requested information for acceptance criteria and study details cannot be extracted as the document pertains to a medical device submission for substantial equivalence based on non-clinical tests and technological characteristics comparison, not an AI/Software as a Medical Device (SaMD) performance study with specific acceptance criteria, test sets, ground truth establishment, or human-in-the-loop effect sizes.

    The document states:

    • "No clinical study is included in this submission." on page 6.

    Instead, the submission relies on:

    • Non-clinical testing: This included biocompatibility (ISO 10993-1, USP <85>), dynamic fatigue (ISO 14801), material specifications (ASTM F136, ASTM F67), sterilization validation (ISO 17665-1, ISO 17665-2, ISO 11137-2, ISO 11137-1), accelerated aging (ASTM F1980), and MRI safety review. These tests verify that the device meets design specifications and complies with relevant standards.
    • Technological characteristics comparison: The proposed device was compared in detail to a primary predicate device (K121995, OSSTEM IMPLANT CO.,LTD TS FIXTURE SYSTEM) and several reference devices for its abutment components. Differences in structure, body diameter, implant length, shelf life, and dimensions of various abutment types were assessed, and the manufacturer argued these differences do not affect substantial equivalence based on mechanical testing, coverage by predicate/reference ranges, or biocompatibility evaluations.

    Since this is a submission for a traditional medical device (dental implant system) and not an AI/SaMD, the typical acceptance criteria and study details related to AI performance (e.g., sensitivity, specificity, AUC, human reader improvement with AI assistance, independent test sets, expert ground truth adjudication) are not applicable or provided in this document.