Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K190665

    Validate with FDA (Live)

    Date Cleared
    2019-12-23

    (283 days)

    Product Code
    Regulation Number
    880.6850
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K142529, K180915

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Neodent Instrument Kit Cases are intended to be used to enclose other medical devices that are to be sterilized by a health care provider. Neodent Instrument Kit Cases are intended to allow sterilization of the enclosed medical devices. Neodent Instrument Kit Cases require the use of FDA cleared wrap to maintain the sterility of the enclosed devices.

    The kits are to be enclosed in a sterilization wrap that is FDA-cleared for the indicated cycles, and moist heat (steam) sterilized using one of the following cycles:

    Fractionated vacuum (pre-vacuum) - Exposure at 132 °C for 4 minutes, 30-minute dry time (for GM Zygomatic Surgical Kit Case) or 20-minute dry time (for GM Helix LG Compact Surgical Kit Case)

    Gravity displacement - Exposure at 132 °C for 15 minutes, 20-minute dry time (only for GM Helix LG Compact Surgical Kit Case)

    Neodent Instrument Kit Cases are intended for sterilization of non-porous loads.

    The combined weight of the GM Zygomatic Surgical Kit Case and the instruments is 738.1 g. The weight of the empty kit case is 515 g.

    The combined weight of the GM Helix LG Compact Kit Case and the instruments is 297.3 g. The weight of the empty kit case is 236 g.

    Neodent Instrument Kit Cases should not to be stacked during sterilization.

    Device Description

    The subject device kit cases are reusable rigid containers, comprising a case bottom (or base), a removable inner tray, and tray lid (lid). The subject device kits are to be used to organize and protect instruments and accessories that are to be sterilized by the healthcare provider. The subject devices include two (2) such kit cases. The lids are manufactured from injection molded polyphenylsulfone resin, the tray and base are manufactured from injection molded polysulfone resin. The designs include grommets and inserts of various geometries manufactured from molded silicone that retain the instruments within the tray and base. The subject device kit cases are provided nonsterile to the end-user.

    AI/ML Overview

    The medical device in question is the Neodent Instrument Kit Cases, intended for use in sterilizing other medical devices by healthcare providers using moist heat (steam). The provided documentation details the acceptance criteria and the studies conducted to demonstrate its performance.

    Here's a breakdown of the requested information:

    1. A table of acceptance criteria and the reported device performance

    Acceptance CriteriaReported Device Performance
    Manual Cleaning Validation
    Hemoglobin Test: - < 0.50 µg/mL - < 55 µg/article - < 0.0078 µg/cm²Passed
    Micro BCA Protein Test: - < 1.1 µg/mL - < 220 µg/article - < 0.018 µg/cm²Passed
    Sterilization Validation (Sterilant penetration and drying time)
    Sterility Assurance Level (SAL) of 10⁻⁶Passed
    Life Cycle (Simulated Usage) Testing (100 cycles)
    Visual and functional inspection following 100 cyclesPassed
    Biocompatibility Testing (Cytotoxicity)
    < 30% inhibition of proliferation of protein contentPassed

    2. Sample size used for the test set and the data provenance

    The document does not specify the exact sample sizes used for each test. For instance, it doesn't state how many kit cases were subjected to manual cleaning validation or how many sterility tests were performed.

    Regarding data provenance:

    • The tests were nonclinical performance data.
    • The document does not explicitly state the country of origin of the data, but the sponsor is "JJGC Indústria e Comércio de Materiais Dentários SA" located in Curitiba, Parana, Brazil. Therefore, the data likely originates from Brazil or a laboratory contracted by the sponsor.
    • The tests as described (validation studies) are inherently retrospective in nature, as they involve testing the manufactured device against pre-defined criteria.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This information is not provided in the document. The studies are nonclinical performance tests and do not involve human expert interpretation of device performance in a medical context where ground truth needs to be established by experts (e.g., radiologists interpreting images). The "ground truth" for these tests is based on objective laboratory measurements and industry standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable/not provided. Adjudication methods like 2+1 or 3+1 are typically used in clinical studies involving multiple human readers to resolve discrepancies in their interpretations. The tests described are laboratory-based performance validations against defined physical and biological criteria, not human-in-the-loop assessments.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No, an MRMC comparative effectiveness study was not done. This type of study is relevant for AI-powered diagnostic or assistive devices, which is not what the Neodent Instrument Kit Cases are. This device is a sterilization accessory.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    No, a standalone algorithm-only performance study was not done. This device is a physical instrument kit case, not a software algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for the nonclinical performance data is based on:

    • Objective laboratory measurements and chemical/biological assays for manual cleaning validation (hemoglobin and protein levels).
    • Sterility Assurance Level (SAL) of 10⁻⁶ which is a a quantitative measure of the probability of a single viable microorganism occurring on an item after sterilization. This is established through microbiological testing.
    • Visual and functional inspection for life cycle testing, against manufacturing specifications.
    • Measurement of cell proliferation inhibition percentage for cytotoxicity testing, an objective biological response measurement.

    These are all objective, measurable criteria derived from recognized standards rather than subjective expert consensus, pathology reports, or patient outcomes data.

    8. The sample size for the training set

    This information is not applicable/not provided. The "Neodent Instrument Kit Cases" is a physical medical device, not an AI, machine learning, or software device that requires a training set.

    9. How the ground truth for the training set was established

    This information is not applicable/not provided as the device is not an AI/ML system requiring a training set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K182865

    Validate with FDA (Live)

    Date Cleared
    2019-05-07

    (208 days)

    Product Code
    Regulation Number
    880.6850
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K142529, K180915

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Neodent Instrument Kits are intended to be used to enclose other medical devices that are to be sterilized by a health care provider. Neodent Instrument Kits are intended to allow sterilization of the enclosed medical devices. Neodent Instrument Kits require the use of FDA cleared wrap to maintain the sterility of the enclosed devices.

    The kits are to be enclosed in a sterilization wrap that is FDA-cleared for the indicated cycles, and moist heat (steam) sterilized using one of the following cycles:

    Fractionated vacuum (pre-vacuum) – Exposure at 132 °C for 4 minutes, 20 minute dry time

    Gravity displacement - Exposure at 132 °C for 15 minutes, 20 minute dry time (or 40 minutes for model number 110.296)

    Neodent Instrument Kits are intended for sterilization of non-porous loads.

    Device Description

    The subject device kits are reusable rigid containers, comprising a case bottom (or base), a removable inner tray base (tray), and tray lid (lid). The subject device kits are to be used to organize and protect instruments and accessories that are to be sterilized by the healthcare provider. The subject devices include six (6) such kits. The lids are manufactured from injection molded polyphenylsulfone resin, the tray base and case bottoms are manufactured from injection molded polysulfone resin. The designs include grommets of various geometries manufactured from molded silicone that retain the instruments within the tray. Certain designs also incorporate a holder of a single geometry made of Ti-6Al-4V-ELI to position items in the trays. The subject device kits are provided nonsterile to the end- user.

    AI/ML Overview

    The provided text does not contain information about an AI/algorithm-based device. Instead, it describes a traditional medical device submission for "Neodent Instrument Kits," which are sterilization trays. As such, the concept of a "test set," "training set," "ground truth," "MRMC comparative effectiveness study," or "AI assistance" is not applicable.

    The document focuses on demonstrating substantial equivalence to a predicate device (K171713) for a Class II medical device (Sterilization Wrap) under product code KCT.

    However, I can extract information related to the performance testing and acceptance criteria for this physical medical device, which is how it meets its intended use.

    Here's an interpretation of the document's content relevant to acceptance criteria and performance:


    The "Neodent Instrument Kits" are reusable rigid containers intended to enclose other medical devices for sterilization by a healthcare provider. The kits themselves must allow sterilization of the enclosed medical devices and maintain their sterility with an FDA-cleared wrap.

    The study proves that the device meets acceptance criteria through a series of non-clinical performance tests, demonstrating its suitability for its intended use and substantial equivalence to a legally marketed predicate device.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document implicitly defines acceptance criteria through the "Purpose of the Testing" and the "Results" sections. The "Conclusion" explicitly states that the device "performs as well as or better than the legally marketed device K171713."

    Acceptance Criteria (Implied from Purpose of Testing)Reported Device Performance
    Manual Cleaning Validation: Device can be effectively cleaned manually.Passed (Custom test)
    Sterilization Validation (Sterilant Penetration and Drying Time): Device allows complete sterilization of enclosed items and dries effectively within specified cycles.Passed (ANSI/AAMI/ISO 17665-1, ANSI/AAMI/ISO 17665-2)
    Life Cycle (Simulate Usage) Testing: Device maintains functionality and integrity over its specified reusable life.Passed (Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling Guidance for Industry and Food and Drug Administration Staff)
    Cytotoxicity Testing: Device materials are not harmful to cells.Passed (ANSI/AAMI/ISO 10993-5)
    Biocompatibility: Device materials are biologically compatible with the body (implicitly, indirectly, through contact with other medical devices).Passed (Assessment per ISO 10993-1, testing per AAMI/ANSI/ISO 10993-5. Results indicate biocompatibility.)
    Intended Use Equivalence: Device performs its intended function (enclosing medical devices for sterilization, allowing sterilization, and maintaining sterility with wrap) comparably to the predicate device."Same" as predicate (K171713) for Intended Use. Performance demonstrated via non-clinical testing.
    Sterilization Cycles and Parameters: Device is compatible with specified steam sterilization cycles (Fractionated vacuum and Gravity displacement) at defined temperatures and times.Successfully demonstrated effectiveness for specified cycles and parameters (132 °C; 4 min exposure, 20 min dry for pre-vacuum; 132 °C; 15 min exposure, 20 or 40 min dry for gravity).
    Reusable Life: Device can be reused for up to 100 cycles after assembly/disassembly, cleaning, and sterilization, verified by visual inspection, dimensional fit, and functional closure."Yes, reusable up to 100 cycles" (Same as predicate)

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the "sample size" in terms of number of devices tested for each non-clinical performance pathway. This type of information is typically found in the full test reports, not a 510(k) summary. However, it implicitly refers to "the device" (singular, representing the device line) being tested.

    • Test Set/Sample Size: Not explicitly stated as a numerical count of individual devices tested, but the results refer to the performance of "the device" and "the subject devices." For physical device testing, a representative sample is used, but the exact number isn't in this summary.
    • Data Provenance: The study was conducted by JJGC Indústria e Comércio de Materiais Dentários S.A. (manufacturer and sponsor) located in Curitiba, Parana, Brazil. The data would be considered retrospective in the context of the 510(k) submission, as it describes tests already performed to support the marketing application.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    This question is not applicable as the device is a physical sterilization tray, not an AI/algorithm-based device requiring expert interpretation of diagnostic images or similar data. The "ground truth" (e.g., sterility, cleanliness, material biocompatibility) is established through standardized laboratory testing methods, not expert consensus in an observational study.

    4. Adjudication Method for the Test Set

    Not applicable. As a physical device undergoing laboratory performance testing, "adjudication" in the sense of reconciling expert opinions on complex data (common in AI studies) is not relevant. Test results are typically objective measurements or qualitative observations (e.g., pass/fail based on predefined criteria in the standards).

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done

    Not applicable. MRMC studies are used for diagnostic interpretation systems (often involving AI) to assess how human reader performance changes with or without AI assistance. This device is a physical sterilization tray.

    6. If a Standalone (algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is not an algorithm. Its "standalone" performance would be its functional performance as a physical object, which is what the non-clinical tests assess (e.g., its ability to withstand sterilization cycles, its material properties).

    7. The Type of Ground Truth Used

    For this physical device, the "ground truth" is derived from several objective and validated methods:

    • Sterility Assurance: Demonstrated by challenging the device with biological indicators (or similar methods) and showing complete kill of microorganisms, consistent with ANSI/AAMI/ISO 17665-1/2 standards.
    • Physical Integrity & Functionality: Demonstrated by visual inspection, component dimensional fit verification, and functional closure verification after repeated cycles of cleaning and sterilization, as per "Life cycle (simulate usage) testing" guidance.
    • Biocompatibility: Demonstrated by standardized cytotoxicity testing (ANSI/AAMI/ISO 10993-5) and broader biocompatibility assessment (ISO 10993-1).
    • Cleanliness: Demonstrated by manual cleaning validation methods.

    These methods establish the "truth" of the device's performance against recognized industry standards and regulatory guidance.

    8. The Sample Size for the Training Set

    Not applicable. This is not an AI/machine learning device; therefore, there is no "training set."

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no "training set" for this physical medical device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1