510(k) Data Aggregation

    K Number
    K213299

    Validate with FDA (Live)

    Date Cleared
    2022-05-11

    (222 days)

    Product Code
    Regulation Number
    882.1400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K142834, K120485

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Pascall Systems, Inc. Wireless EEG System, is intended to be used for measuring the electrical activity of a patient's brain, obtained by placing electrodes on the forehead and wirelessly transmitting the electroencephalographic (EEG) signals for storage and display. The Pascall Systems, Inc. Wireless EEG System, is intended for use in the acquisition of EEG signals, displaying them in real time and storing them for later review and analysis. The Pascall Systems, Inc. Wireless EEG System, is intended for use in a hospital Operating Room, Post Anesthesia Care Unit, Intensive Care Unit, Emergency Department, or in other medical facilities such as inpatient and outpatient (ambulatory) surgery settings.

    The Pascall Systems, Inc. Wireless EEG System is indicated for use on patients 18 years of age or older and is to be used by licensed medical professionals that have been adequately trained in the use and interpretation of raw EEG data for determination of brain state during anesthesia. The Pascall Systems, Inc. Wireless EEG System does not provide any diagnostic conclusion about the patient's condition.

    Device Description

    The Pascall Systems Wireless EEG system is a brain monitoring or Electroencephalographic (EEG) device. The system is designed to record and display four channels of electroencephalograms (EEGs) obtained from noninvasive electrodes placed on a patient's head. The acquired EEG waveforms (4 channels) and processed EEG variables which include a Spectrogram, Artifact index, electromyography (EMG) index, burstsuppression probability, and phase-amplitude modulogram are continuously displayed by the system. Licensed medical professionals which include anesthesiologists, nurse anesthetists, etc. combine and interpret the data presented by the Pascall Systems Wireless EEG with information provided by other instruments in the operating room. The primary purpose of the Pascall Systems Wireless EEG is in the acquisition of electroencephalographic (EEG) signals, displaying them along with the processed variables in real time and storing them for later review and analysis. The Wireless EEG system is intended for use in a hospital Operating Room, Post Anesthesia Care Unit, Intensive Unit, Emergency Department, or in other medical facilities such as inpatient and outpatient (ambulatory) surgery settings.

    AI/ML Overview

    The provided text describes the Pascall Systems, Inc. Wireless EEG System and its substantial equivalence to predicate devices, but it does not contain a specific study demonstrating direct acceptance criteria for an AI/algorithm's performance. Instead, it focuses on the device's overall performance as an EEG system against established medical device standards and a comparison to predicate devices, particularly regarding its functional components and display features.

    However, the document does mention testing related to the "Burst Suppression Ratio" (BSR) which involves a comparison to "manual review of the raw EEG timeseries." This can be interpreted as a form of algorithm performance evaluation.

    Here's an attempt to extract and synthesize the information based on your request, focusing on the BSR "study" as the most relevant part, and acknowledging the limitations in the provided text:

    Study and Acceptance Criteria Description (Focused on Burst Suppression Ratio - BSR)

    The Pascall Systems, Inc. Wireless EEG System underwent non-clinical bench performance testing, which included a specific test to establish substantial equivalence of its Burst Suppression Ratio (BSR) output.

    1. Table of Acceptance Criteria and Reported Device Performance

    Performance CharacteristicAcceptance CriteriaReported Device Performance & Results
    Burst Suppression Ratio< 5% difference from manual review for 100% agreementAll runs of the 49 segments passed the acceptance criteria, demonstrating a 100% level of agreement (meaning < 5% difference from manual review).

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: 49 segments of EEG signals from 10 patients.
    • Data Provenance: Not explicitly stated (e.g., country of origin). The data is implicitly retrospective as it involved "segments of EEG signals from 10 patients."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    • Number of Experts: Not specified.
    • Qualifications of Experts: Not specified, but the ground truth was "manual review of the raw EEG timeseries," implying review by qualified professionals (likely neurologists or neurophysiologists experienced in EEG interpretation, though not explicitly stated).

    4. Adjudication Method for the Test Set

    • Adjudication Method: Not explicitly stated. However, since the ground truth was "manual review," it implies direct human interpretation rather than a multi-reader consensus method like 2+1 or 3+1. It's possible a single expert or an unspecified number of experts performed the "manual review."

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • Was it done?: No. The document does not describe an MRMC study comparing human readers with and without AI assistance. The testing focuses on the device's internal performance against a manual ground truth.

    6. Standalone (Algorithm-Only) Performance Study

    • Was it done?: Yes, for the Burst Suppression Ratio (BSR) calculation. The device's algorithm for BSR was tested by "repeatedly inputting 49 segments of EEG signals" and comparing its output to "manual review." This represents a standalone performance evaluation of the BSR computation. The validation of the real-time Spectrogram, Phase-Amplitude display, and EMG Index using "known simulated input signals" also constitutes a standalone performance evaluation of these specific algorithms/outputs.

    7. Type of Ground Truth Used

    • Ground Truth Type: Expert consensus/manual review (specifically, "manual review of the raw EEG timeseries" for BSR). For other outputs like Spectrogram, Phase-Amplitude, and EMG Index, "known simulated input signals" were used, which acts as a defined ground truth.

    8. Sample Size for the Training Set

    • Training Set Sample Size: Not specified. The document does not provide details about a training set, implying that either the device's algorithms are not machine learning-based in a way that requires explicit training data disclosure in this context, or that information was not deemed necessary for this 510(k) summary.

    9. How the Ground Truth for the Training Set Was Established

    • Ground Truth Establishment for Training Set: Not applicable as a training set is not described.

    Summary of Device Performance (General)

    Beyond the specific BSR study, the document broadly describes the Pascall Systems, Inc. Wireless EEG System's performance in comparison to predicate devices and relevant standards:

    • Non-Clinical Bench Performance Testing: The system was tested in accordance with performance standards for electroencephalographic devices (IEC 60601-1, IEC 60601-1-2, IEC 80601-2-26, ISO 10993 Parts 5 and 10).
    • Test Objectives: To verify claimed ranges of measurement, essential performance requirements (amplitude/rate accuracy, dynamic range, noise, frequency response, common mode rejection).
    • Test Methods: Bench testing on end-to-end systems with simulated input.
    • Pass/Fail Criteria: Compliance with claimed range and precision in labeling.
    • Results Summary: The system met all applicable specifications and was found substantially equivalent to the predicate device.
    • Biocompatibility: Patient-contacting materials passed ISO 10993 tests for cytotoxicity, skin sensitization, and skin irritation.

    Overall Conclusion from the document: The Pascall Systems, Inc. Wireless EEG System is substantially equivalent to the predicate device based on review of test results and comparison of characteristics and specifications.

    Ask a Question

    Ask a specific question about this device

    K Number
    K130238

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2015-03-04

    (762 days)

    Product Code
    Regulation Number
    882.1400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K051178, K963644, K021185, K120485, K131789

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AE-918P EEG Neuro Unit is an 8 channel EEG measuring unit that connects to a Nihon Kohden patient monitor and is intended to monitor brain function. The unit amplifies and analyzes EEG and displays the EEG waveform and the result of analysis on the patient monitor.

    The AE-918P EEG Neuro Unit includes the calculation of a set of quantitative measures intended to monitor and analyze the EEG waveform. These include quantitative EEG functions such as SEF, MDF, PPF, TP, CSA, DSA, %Theta, %Alpha, %Beta, %Gamma, Abs Delta, Abs Alpha, Abs Beta, and Abs Gamma. These quantitative EEG measures should always be interpreted in conjunction with review of the original EEG waveform. The aEEG functionality included in the AE-918P EEG Neuro Unit is intended to monitor the state of the brain.

    The device is intended for use by medical personnel in any location within a medical facility, physician's office, laboratory, clinic or nursing home under direct supervision of a medical professional.

    Device Description

    The AE-918P is an 8 channel digital Electroencephalography (EEG) that connects to a Nihon Kohden patient monitor. It receives EEG data from patients and digitizes the signals, the waveforms and analysis are displayed on a Nihon Kohden Patient Monitor.

    The AE-918P is contained in a small enclosure that contains the EEG amplifier and digital circuitry. This enclosure is mounted to the bottom of the patient monitor and connects to the patient monitor through the multilink cable.

    AI/ML Overview

    The Nihon Kohden AE-918P Neuro Unit is an 8-channel EEG measuring unit that connects to a Nihon Kohden patient monitor. It amplifies and analyzes EEG and displays the EEG waveform and analysis results on the patient monitor, intended for monitoring brain function.

    Here's an analysis of its acceptance criteria and the study proving its performance, based on the provided document:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly list "acceptance criteria" in a quantitative manner for specific performance metrics like accuracy, sensitivity, or specificity. Instead, the performance testing focuses on ensuring the device meets established safety and performance standards for electroencephalographs and demonstrating substantial equivalence to predicate devices. The "reported device performance" is largely qualitative, stating that the device "performed within specifications" and was "equivalent in safety and effectiveness" to its main predicate.

    Acceptance Criteria (Implied from testing standards and predicate comparison)Reported Device Performance
    Safety and Electrical Performance: Conformance to IEC 60601-1 (various parts) for general requirements, electromagnetic compatibility, and particular requirements for electroencephalographs."The AE-918P was subjected to safety and performance testing procedures. The AE-918P has undergone validation and verification testing to ensure conformance to all design requirements.""Testing to the following standards was done: IEC 60601-1 Part1: General requirements for safety 1998-12, Amendment 1 (1991-11), Amendment 2 (1995-03); IEC 60601-1-2 2nd edition (2001-09), Amendment 1 (2004-09); IEC 60601-2-26 Part 2-26: Particular Requirements for the safety of electroencephalograph 2002-11."
    Biocompatibility: Electrodes used with the device are biocompatible."Electrodes used as accessories with the device are the same as those of the predicate device and have previously been testing for biocompatibility for a surface contacting device of prolonged duration according to ISO 10993-1 Biological Evaluation of Medical Devices Part 1: Evaluation and Testing."
    Quantitative EEG Measures (SEF, MDF, PPF, TP, CSA, DSA, %Theta, %Alpha, %Beta, %Gamma, Abs Delta, Abs Alpha, Abs Beta, Abs Gamma, aEEG): Calculation and display of trends are substantially equivalent to predicate devices."Additionally, the system has undergone comparison testing to ensure the substantial equivalence of the calculation and display of EEG trends. These tests verified that the device performed within specifications."The device includes calculation of these measures, with specific functions like MDF, TP, and aEEG being supported by additional predicates (K051178, K963644, K021185, K120485, K131789).
    Overall Equivalence: Safety and effectiveness are equivalent to the main predicate device EEG-1200A."Based on the comparison information in the technical comparison chart above and confirmed by verification/validation testing in compliance with the Design Control requirements, the AE-918P was shown to be equivalent in safety and effectiveness to the main predicate device EEG-1200A."

    2. Sample Size Used for the Test Set and the Data Provenance

    The document explicitly states: "No Clinical testing was required." This indicates that the performance testing for this device primarily relied on bench testing, comparison to predicate devices, and internal validation/verification testing according to design control processes. Therefore, there is no test set of patient data and consequently, no specified data provenance (country of origin, retrospective/prospective).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts

    As no clinical testing was performed and no patient-specific "test set" was used, there were no experts used to establish ground truth for such a set. The "ground truth" for the device's technical specifications and performance was based on engineering validation against established standards and comparison to well-characterized predicate devices.

    4. Adjudication Method for the Test Set

    Since no clinical test set was used, there was no adjudication method employed for a test set.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs without AI Assistance

    No MRMC comparative effectiveness study was done. This device is an EEG measuring unit, not an AI-assisted diagnostic tool that would typically involve human readers interpreting AI output. Its function is to amplify, analyze, and display EEG waveforms and quantitative measures for medical personnel to interpret in conjunction with the original waveform.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    The device's functionality involves "amplifies and analyzes EEG and displays the EEG waveform and the result of analysis on the patient monitor." The quantitative EEG measures "should always be interpreted in conjunction with review of the original EEG waveform." This implies the device provides analytical output that is not intended to be used in a standalone, algorithm-only fashion without human interpretation and review of the raw EEG data. The performance testing verified the device's ability to calculate and display these measures and trends accurately, rather than its diagnostic performance in a standalone mode.

    7. The Type of Ground Truth Used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for demonstrating the device's performance was primarily:

    • Engineering specifications and design requirements: Verifying that the device met its intended technical parameters.
    • Regulatory standards: Conformance to IEC 60601 series for safety and performance of medical electrical equipment, particularly for electroencephalographs.
    • Predicate device characteristics: The comparison testing aimed to show "substantial equivalence" of the calculation and display of EEG trends to those of legally marketed predicate devices. This indicates that the established, accepted performance of existing devices served as a benchmark for "ground truth."

    8. The Sample Size for the Training Set

    The document does not mention any "training set" of data. As previously noted, no clinical testing was required, and the device's validation appears to be based on engineering tests and comparison to existing technologies, not on machine learning or AI models that require specific training data.

    9. How the Ground Truth for the Training Set Was Established

    Since there was no mention of a training set, the method for establishing its ground truth is not applicable to this submission.