510(k) Data Aggregation

    K Number
    K201728

    Validate with FDA (Live)

    Date Cleared
    2021-03-08

    (258 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Versalock Periprosthetic Femur Plates is indicated for temporary internal fixation and stabilization of fractures and osteotomies of the femur, including:

    • · Periprosthetic fractures
    • Comminuted fractures
    • Supracondylar fractures
    • Trochanteric fractures
    • · Fractures in normal and osteopenic bone
    • Non-unions and Malunions.
    Device Description

    The purpose of this submission is to obtain marketing clearance for the Versalock Periprosthetic Femur Plates System which is composed of plates, screws and, a cerclage cable and related device.

    The subject devices are designed for the treatment of femur fractures, particularly, periprosthetic femur fractures. The plates are available in the following design-types to be used according to the fracture location: Proximal and Distal Femur Periprosthetic Plates, Trochanteric Periprosthetic Plates and Condylar Femur Plates.

    The plates are for use with the subject device screws to fix them to the bone. The following compatible screws are available for this purpose: Cortical Screws, Versalock Variable Angle Locking Screws, Versalock Variable Angle Screws, Versalock Variable Angle Cannulated Screws and Versalock Variable Angle Periprosthetic Screw. The Trochanteric Plate Fastening Screw is to connect one plate to another when a Trochanteric Periprosthetic Plates is used. The Versalock Spacer Screw is threaded into the plate hole prior to plate insertion to act as a spacer providing no contact between the plate and the bone surface.

    The Gama Cable is a cerclage cable indicated to provide fixation and/or stabilization of the bone when it is not possible the usage of any screw. The Gama Cable related devices are the Gama Cable Lock and the Versalock Connector Screw. During the installation of the Gama Cable Lock is crimped to lock the movement of the cable, maintaining the tensioning applied while the Versalock Connector Screw , which holds the cable to the plate and set the proper cable routing position. The Gama Cable and related devices are used in conjunction with the Proximal or Distal Femur Periprosthetic Plates, or Condylar Femur Plates

    The subject devices are made of made of titanium alloy (ASTM F136) with exception of the Gama Cable Lock which it is made of commercially pure titanium (ASTM F67). All the subject devices are coloredanodized.

    The devices must only be used by qualified surgeons mastering the surgical technique, having been trained and qualified in orthopedic surgeries.

    AI/ML Overview

    The provided document is a 510(k) summary for the Versalock Periprosthetic Femur Plates System - GMReis. This document outlines the regulatory submission for a medical device and, as such, does not contain information about a study that proves the device meets specific acceptance criteria in terms of clinical performance or diagnostic accuracy. Instead, it focuses on demonstrating substantial equivalence to a predicate device through non-clinical performance testing.

    Therefore, many of the requested sections related to clinical studies, sample sizes for test and training sets, expert ground truth adjudication, MRMC studies, or standalone algorithm performance will not be available in this document.

    Here's a breakdown of the information that can be extracted or inferred from the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document doesn't provide a table of explicit acceptance criteria with specific numerical targets. Instead, it states that performance was demonstrated through mechanical testing according to established ASTM standards. The "performance" in this context refers to the device's mechanical integrity and functionality, rather than a clinical outcome.

    Acceptance Criteria (Standard Adherence)Reported Device Performance (Demonstrated Adherence)
    Adherence to ASTM F382 for plates (static and dynamic testing)Performance of subject device plates was demonstrated through static and dynamic testing according to ASTM F382.
    Adherence to ASTM F543 for screws (mechanical testing)Performance of subject screws was demonstrated through mechanical testing according to ASTM F543.
    Adherence to ASTM F2180 for cerclage cable (mechanical testing)Performance of the cerclage cable was demonstrated through mechanical testing according to ASTM F2180.
    System construct testing for cerclage cablePerformance of the cerclage cable was demonstrated through system construct testing.
    Biocompatibility established via risk assessment following ISO 10993-1Biocompatibility was established through a risk assessment following ISO 10993-1.
    Equivalence in indications for use, design principles, materials, physical dimensions, and sterilization method to predicate deviceThe subject and predicate devices have equivalent intended use and equivalent technological characteristics. The subject and predicate devices are all manufactured from identical or equivalent materials and share equivalent design characteristics. The subject and predicate devices encompass equivalent physical dimensions and are to be sterilized by identical or equivalent method.
    No new issues of safety or efficacy raised by technological differencesAny difference in the technological characteristics do not raise new issues of safety or efficacy.

    2. Sample size used for the test set and the data provenance:

    • Sample Size: Not applicable. This document describes mechanical testing of physical device components, not a study involving patient data or a "test set" in the context of AI/diagnostic device performance. The sample sizes would refer to the number of plates, screws, and cables tested in the lab. This specific number is not provided, though it would typically be defined by the ASTM standards.
    • Data Provenance: Not applicable. The data comes from internal mechanical testing, not patient data from a specific country or collected retrospectively/prospectively.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable. Ground truth as typically defined for diagnostic AI/clinical studies (e.g., expert consensus on images, pathology results) is not relevant to this type of device submission. The "ground truth" here is the adherence to mechanical engineering standards, which is determined by test procedures and measurement against those standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • Not applicable for the reasons stated above.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No. This is not a diagnostic AI device, and therefore, an MRMC study is not relevant or mentioned.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • No. This is a physical medical implant device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    • For the non-clinical performance (mechanical testing), the "ground truth" is adherence to established engineering standards (ASTM F382, ASTM F543, ASTM F2180) and a risk assessment based on biocompatibility standards (ISO 10993-1).
    • For the substantial equivalence claim, the "ground truth" is the characteristics of the predicate device, which the subject device is compared against.

    8. The sample size for the training set:

    • Not applicable. There is no training set mentioned as this is not an AI/machine learning device.

    9. How the ground truth for the training set was established:

    • Not applicable. There is no training set.
    Ask a Question

    Ask a specific question about this device

    K Number
    K141527

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2015-03-30

    (294 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K090047, K092247, K030310, K100776, K120689, K110354

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DePuy Synthes Variable Angle Locking Hand System is intended for fracture fixation of the hand and other small bones and small bone fragments, in adults and adolescents (12-21) particularly in osteopenic bone.
    System indications include the following:

    • Open reduction and internal fixation of fractures, mal-unions, and non-unions
    • Following excision of benign bone tumors
    • Replantations and reconstructions
    • Arthrodeses of joints involving small bones
    • Osteotomies, including deformity correction such as rotation, lengthening, shortening
    • Pathological fractures, including impending pathologic fractures
    Device Description

    The DePuy Synthes Variable Angle Locking Hand System consists of metallic plates and screws that offer screw-to-plate locking designed for various fracture modes of the hand. Generally, the system consists of plates, screws, and instruments which feature variable angle locking technology. The plates contained in the DePuy Synthes Variable Angle Locking Hand System are offered in a range of configurations to accommodate patient anatomy and surgical need. The plates are designed to accept existing 1.5mm cortex screws (K090047), previously cleared 1.5mm Locking Screws at the nominal angle only (K090047), and new 1.5mm VA Locking Screws. The new 1.5mm VA Locking Screws feature existing variable angle locking technology (K100776, K120689, K110354), and are designed to fit in the 1.5mm holes of the subject plates.

    AI/ML Overview

    The provided text is a 510(k) premarket notification for a medical device (DePuy Synthes Variable Angle Locking Hand System). This type of document focuses on demonstrating substantial equivalence to a legally marketed predicate device rather than presenting extensive clinical study data with acceptance criteria for device performance as would be seen in a PMA or De Novo submission.

    Therefore, the document does not contain information typically found in acceptance criteria and study reports for software/AI devices (e.g., sample size, expert qualifications, adjudication methods, MRMC studies, effect sizes, standalone performance, training set details).

    However, it does describe the non-clinical testing performed to demonstrate the substantial equivalence of the mechanical aspects of the device.

    Here's an analysis of what information is available in the provided text, structured to address your request as much as possible given the limitations of the document:


    Acceptance Criteria and Study to Prove Device Performance

    This 510(k) submission primarily relies on demonstrating substantial equivalence to predicate devices through non-clinical mechanical testing rather than clinical performance metrics with specific acceptance criteria typically associated with software or AI devices. The information below reflects the mechanical performance testing mentioned.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state numerical "acceptance criteria" for the non-clinical tests in the format of a table, nor does it provide the quantitative results of these tests. Instead, it lists the types of tests performed to support the device's performance and substantial equivalence to predicates.

    Acceptance Criteria Category (Implied)Reported Device Performance (Implied by testing)
    Mechanical Strength & DurabilityDynamic Fatigue Testing: Performed on representative constructs to assess long-term durability and resistance to cyclic loading.
    Screw Torsional PropertiesTorsional properties of 1.5mm VA Locking Screws per ASTM F543: Demonstrates the screw's resistance to twisting forces during insertion or under load.
    Screw Pullout StrengthPullout strength of 1.5mm VA Locking Screws per ASTM F543: Assesses the strength of the screw's fixation in bone.
    Screw Insertion TorqueInsertion Torque of 1.5mm VA Locking Screws per ASTM F543: Evaluates the force required to insert the screws.
    Structural Integrity & Stress DistributionFinite Element Analysis (FEA): Used to determine worst-case constructs and analyze stress distribution within the device and its interaction with simulated bone.
    Material BiocompatibilityNot explicitly mentioned in the "Substantial Equivalence" section but implied for all implantable devices.

    2. Sample Size and Data Provenance

    • Sample Size for Test Set: Not specified for the mechanical tests. For non-clinical mechanical testing, sample sizes are typically determined by relevant ASTM standards or internal validation protocols, often involving a small number of representative samples.
    • Data Provenance: The tests are non-clinical (laboratory-based) and conducted by the manufacturer (DePuy Synthes). Country of origin is implied to be within the manufacturer's operational locations (e.g., USA, as the submitting entity is Synthes USA). The data is by nature "prospective" in the sense that the tests were designed and executed to evaluate this specific device configuration.

    3. Number of Experts and Qualifications for Ground Truth

    Not applicable. This device is a mechanical implant, not an AI/software device requiring expert interpretation for ground truth establishment. The "ground truth" for mechanical testing is established by the physical properties of the materials and designs under standardized test conditions.

    4. Adjudication Method

    Not applicable. Adjudication methods (e.g., 2+1, 3+1) are used for clinical image interpretation or diagnostic decisions, not for mechanical testing of orthopedic implants.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    Not applicable. This is a mechanical orthopedic implant, not an imaging device or AI diagnostic tool that would typically involve human readers.

    6. Standalone Performance

    The "standalone performance" in this context refers to the device's mechanical performance in laboratory settings, independent of human interaction during the test itself. The non-clinical tests (Dynamic Fatigue, Torsional, Pullout, Insertion Torque, FEA) evaluate the device in this standalone capacity.

    7. Type of Ground Truth Used

    For the mechanical tests, the "ground truth" is defined by:

    • Standard ASTM methodologies: (e.g., ASTM F543 for screw properties).
    • Engineering principles and material properties: Used in Finite Element Analysis.
    • Physical measurements under controlled laboratory conditions.

    This differs significantly from a "ground truth" for a diagnostic medical device which would involve expert consensus, pathology, or outcomes data.

    8. Sample Size for Training Set

    Not applicable. This is a mechanical device, not an AI/machine learning algorithm that requires a training set.

    9. How Ground Truth for Training Set Was Established

    Not applicable, as there is no training set for an AI/ML algorithm involved in the primary function or evaluation of this mechanical device.