510(k) Data Aggregation

    K Number
    K203818

    Validate with FDA (Live)

    Date Cleared
    2021-06-11

    (164 days)

    Product Code
    Regulation Number
    884.5300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K101098

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Replens Long-Lasting Vaginal Moisturizer is a personal lubricant for vaginal application, intended to moisturize and lubricate, to enhance the ease and comfort of intimate sexual activity and to supplement the body's natural lubrication. This product is compatible with natural rubber latex and polyisoprene condoms. This product is not compatible with polyurethane condoms.

    Device Description

    Replens Long-Lasting Vaginal Moisturizer is a personal lubricant that is non-sterile, water-based, and provides lubrication during intimate sexual activity. It is a smooth, white, homogenous vaginal gel packaged with a reusable applicator. This device is compatible with natural rubber latex and polyisoprene condoms and is not compatible with polyurethane condoms. Its formulation consists of Water, Glycerin, Mineral Oil, Polycarbophil, Carbomer Homopolymer Type B, Hydrogenated Palm Oil Glyceride, Sorbic Acid, Benzyl Alcohol, Ethylhexylglycerin, tocopherol, and Sodium Hydroxide. Replens Long-Lasting Vaginal Moisturizer is packaged in a 35g aluminum tube (14 applications), with a reusable two-piece, blue translucent, polyethylene applicator designed to dispense 2.5g of lubricant.

    The reusable applicator is packaged with an over-wrap in clear, biaxially oriented polypropylene film. The subject device and applicator are packaged together in a carton with a consumer leaflet.

    AI/ML Overview

    The provided document is a 510(k) Pre-market Notification from the FDA regarding a medical device, the Replens Long-Lasting Vaginal Moisturizer. This document focuses on demonstrating substantial equivalence to a previously cleared predicate device, rather than proving that the device meets specific acceptance criteria through a clinical study with a test set, expert ground truth, or MRMC studies.

    Therefore, many of the requested details about acceptance criteria, study design, and performance metrics (like sensitivity, specificity, or reader improvement) are not applicable to this type of regulatory submission. The goal here is to show that the new device is as safe and effective as the predicate device, primarily through non-clinical performance testing and comparison of technological characteristics.

    However, I can extract information related to what is presented as "acceptance criteria" in the context of this submission, which are primarily product specifications and performance testing results.

    Here's a breakdown of the requested information based on the provided document:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document presents product specifications as the "acceptance criteria" for the device itself, rather than acceptance criteria for a diagnostic algorithm's performance. The "reported device performance" is essentially that the device meets these specifications.

    PropertyAcceptance Criteria (Specification)Reported Device Performance (Implied by "demonstrated that the device can maintain its specifications")
    AppearanceWhite to off-white smooth homogenous gelMet
    OdorOdorlessMet
    Viscosity30,000 - 130,000 cPsMet
    pH2.5 - 3.5Met
    Osmolality1200 - 2000 mOsm/KgMet
    Total Aerobic Microbial Count (TAMC)<100 cfu/gMet
    Total Yeast and Mold Count (TYMC)<10 cfu/gMet
    Pseudomonas aeruginosaAbsent/gMet
    Staphylococcus aureusAbsent/gMet
    Candida albicansAbsent/gMet
    Escherichia coliAbsent/gMet
    Salmonella sp.Absent/gMet
    Antimicrobial Effectiveness (E. coli, P. aeruginosa, S. aureus)Not less than 2.0 log reduction from initial count at 14 days, and no increase from 14-day count at 28 days.Met
    Antimicrobial Effectiveness (C. albicans, Aspergillus brasiliensis)No increase from initial calculated count at 14 and 28 days.Met
    BiocompatibilityNon-cytotoxic, non-irritating, non-sensitizing, non-systemically toxic.Met
    Shelf-Life (duration)22 monthsMet (device maintains specifications over this duration)
    Condom CompatibilityCompatible with natural rubber latex and polyisoprene condoms; not compatible with polyurethane condoms.Met

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not applicable in the traditional sense of a "test set" for an AI or diagnostic algorithm. The testing described is primarily laboratory-based (e.g., chemical properties, microbial testing, biocompatibility).
    • Data Provenance: Not explicitly stated regarding country of origin for the non-clinical tests. The tests themselves are laboratory tests following ISO and USP standards. All testing appears to be "prospective" in the sense that it was conducted specifically for this submission.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Not applicable. This submission is for a personal lubricant, not a diagnostic device requiring expert interpretation of images or other clinical data to establish ground truth. Ground truth for the reported properties (e.g., pH, viscosity, microbial counts) is established by analytical methods and laboratory equipment.

    4. Adjudication Method for the Test Set

    • Not applicable. There is no human interpretation or adjudication involved in the type of laboratory testing described.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    • No. This is not an AI/diagnostic device that would require an MRMC study.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    • Not applicable. This device is a personal lubricant, not a software algorithm.

    7. The Type of Ground Truth Used

    The ground truth for the "acceptance criteria" presented (device specifications) is derived from:

    • Analytical Chemistry and Physical Property Measurements: e.g., pH meters, viscometers, osmolality measurements.
    • Microbiological Testing: e.g., plate counts for microbial limits, specific assays for pathogen absence and antimicrobial effectiveness.
    • Biocompatibility Testing Standards: Following ISO 10993 series (cytotoxicity, sensitization, irritation, systemic toxicity).
    • Condom Compatibility Standards: Following ASTM D7661-10.

    8. The Sample Size for the Training Set

    • Not applicable. This is not an AI/machine learning device that uses a "training set."

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable.

    In summary: The provided document is a 510(k) premarket notification for a medical device (a personal lubricant). Its purpose is to demonstrate substantial equivalence to a predicate device, primarily through non-clinical performance data (product specifications, biocompatibility, shelf-life, condom compatibility). It does not involve a clinical study with human subjects, diagnostic performance metrics, or AI algorithms, which are often associated with the detailed "acceptance criteria" and "study" descriptions requested in the prompt.

    Ask a Question

    Ask a specific question about this device

    K Number
    K150883

    Validate with FDA (Live)

    Date Cleared
    2015-09-01

    (152 days)

    Product Code
    Regulation Number
    884.5300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K101098, K070587

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    HyaloGYN® is a personal lubricant for vaginal application intended to moisturize and lubricate, to enhance the ease and comfort of intimate sexual activity and supplement the body's natural lubrication. This product is compatible with polyisoprene condoms.

    Device Description

    HyaloGYN is a line extension to add a formulation of HyaloGYN not made with parabens. It is a nonsterile, colorless, odorless, transparent, aqueous, hydrating gel that contains "Hydeal-D®" (a partial benzyl ester of hyaluronic acid), propylene glycol, a carbomer, preservatives and sodium hydroxide (to balance the pH). The hyaluronic acid is manufactured using a bacterial fermentation process.

    HyaloGYN is a non-hormonal vaginal moisturizer intended to hydrate the vaginal epithelium because of the strong hydrating properties of its hyaluronic acid derivative component. The carbomer and propylene glycol combine with the hyaluronic acid derivative to enable HyaloGYN to achieve its thick, viscous gel form, and the mucoadhesive properties to allow it to adhere to the vaginal mucosa, enhancing the residence time, thus hydrating this tissue. It is provided in an aluminum tube and packaged together with single-use applicators in a cardboard box. HyaloGYN has a shelf life of 3 years.

    AI/ML Overview

    This document is a 510(k) summary for the HyaloGYN Vaginal Hydrating Gel, demonstrating its substantial equivalence to previously cleared devices. It describes the device, its intended use, and provides a summary of performance data including biocompatibility, bench testing, and a clinical study.

    Here's a breakdown of the requested information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of "acceptance criteria" for the device's main function (vaginal moisturizing and lubrication) in the typical sense of numerical thresholds for sensitivity, specificity, or similar metrics for a diagnostic or AI device. Instead, the "acceptance criteria" are implied by the successful completion of various tests and the positive outcomes of the clinical study, demonstrating safety and effectiveness for its intended use.

    However, where an explicit criterion is mentioned (condom compatibility), it is included. For other assessments, the "acceptance criteria" are interpreted as successful completion of the test/study without adverse findings, and "reported device performance" summarizes the key findings.

    Acceptance Criteria (Implied/Explicit)Reported Device Performance
    Biocompatibility:
    - In vitro Cytotoxicity Assay per ISO 10993-5Confirmed safe.
    - Sensitization (Guinea Pig Maximization Test) per ISO 10993-10Confirmed safe.
    - Vaginal Irritation Test per ISO 10993-10Confirmed safe.
    - Acute Systemic Toxicity Rat per ISO 10993-11Confirmed safe.
    Bench Performance:
    - Condom compatibility per ASTM D7661-10The subject device product is compatible with polyisoprene condoms.
    - AppearanceMet product specifications at release.
    - OdorMet product specifications at release.
    - ColorMet product specifications at release.
    - WeightMet product specifications at release.
    - pHMet product specifications at release.
    - Hyaluronic acid contentMet product specifications at release.
    - Total Aerobic Microbial CountMet product specifications at release.
    - Total combined yeasts/molds countMet product specifications at release.
    - Absence of common pathogens (Pseudomonas aeruginosa, StaphylococcusMet product specifications at release.
    aureus, Candida albicans)
    - ViscosityMet product specifications at release.
    - OsmolalityMet product specifications at release.
    Clinical Performance:
    - Safety (absence of adverse events)Safety considered excellent, demonstrated by absence of adverse events and investigator's overall tolerability score (98.7%). No alterations of the vaginal ecosystem.
    - Effectiveness (moisturizing effects on vaginal mucosa)The test material demonstrated moisturizing effects on the vaginal mucosa.
    Stability Testing:
    - Shelf lifeHyaloGYN® has a 36-months shelf life based on the results of shelf life testing.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample size for the test set:
      • Clinical Study: 80 women were enrolled.
      • Biocompatibility and Bench Testing: Sample sizes are not explicitly stated for these tests, but they were conducted on the device material itself.
    • Data provenance:
      • Clinical Study: Conducted in Italy, and was a prospective, open, uncontrolled pilot clinical study.
      • Other tests (Biocompatibility, Bench, Stability): The specific origin of data for these tests is not explicitly stated beyond being conducted by Fidia.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • The document refers to "investigator's overall assessment of tolerability score (98.7%)" in the clinical study. It does not specify the number of investigators/experts or their specific qualifications (e.g., years of experience, specialty beyond being the study investigator) who established ground truth for the clinical performance points like tolerability and moisturizing effects.
    • For biocompatibility and bench testing, "experts" involved are implied to be personnel conducting the tests according to ISO/ASTM standards, but their specific number and qualifications are not detailed.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • The document does not describe an explicit adjudication method (like 2+1 or 3+1) for the clinical study's outcomes. It was an "open, uncontrolled clinical study" where a single investigator's assessment contributed to the "tolerability score."

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done.
    • This device is a vaginal hydrating gel, not an AI or diagnostic imaging device. Therefore, a study assessing human reader improvement with AI assistance is not applicable.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • No, this is not an algorithm or AI device. Therefore, "standalone" algorithm performance is not applicable. The device itself (the gel) is the "standalone" product being tested.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Clinical Study: The ground truth for effectiveness (moisturizing effects) and safety (tolerability, absence of adverse events, no alterations of vaginal ecosystem) was established through clinical observation and assessment by the study investigator based on pre-defined clinical endpoints and patient feedback.
    • Biocompatibility Testing: Ground truth established by adherence to and results of standardized ISO test methods.
    • Bench Testing: Ground truth established by adherence to product specifications at release (e.g., pH, viscosity, microbial counts) and standardized ASTM test methods (condom compatibility).

    8. The sample size for the training set

    • This device is a medical product (gel), not an AI algorithm. Therefore, the concept of a "training set" for an algorithm is not applicable. Its formulation and design would be based on scientific principles and previous research/development, not algorithmic training data.

    9. How the ground truth for the training set was established

    • As stated above, this is not an AI algorithm, so there is no "training set" in the context of machine learning. The "ground truth" for the device's formulation and design would be based on chemical, biological, and pharmaceutical principles, historical data from similar products, and laboratory studies of its components.