510(k) Data Aggregation

    K Number
    K241488

    Validate with FDA (Live)

    Device Name
    TrainFES Advance
    Manufacturer
    Date Cleared
    2025-02-05

    (257 days)

    Product Code
    Regulation Number
    890.5850
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K080950

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For Prescription and Home Use by prescription from a medical professional:
    The TrainFES advanced is a neuromuscular electrical stimulator indicated for use under medical supervision for adjunctive therapy in the treatment of medical diseases and conditions.

    As a powered muscle stimulator, TrainFES advanced is indicated for the following conditions:

    • Relaxation of muscle spasms
    • Prevention or retardation of disuse atrophy
    • increasing local blood circulation
    • immediate post-surgical stimulation of calf muscles to prevent venous thrombosis
    • Maintaining or increasing range of motion
    • Muscle re-education

    As an external functional neuromuscular stimulator (FES), TrainFES Advanced is indicated for the following conditions:

    • Helps to relearn voluntary motor functions of the extremities.

    TrainFES' Advanced intended population is anybody aged 22 or over.

    Environments of use: TrainFES Advanced devices can be used by both therapists and patients, in the clinic, hospitals or at home.

    Platform: TrainFES is a battery-powered, wireless device, accessible through software.

    Device Description

    TrainFES Advanced is a portable functional electrostimulator with 6 channels designed for use in the clinics and hospitals by the medical professionals as well as in the home environment by the patient. This device generates electrical impulses to stimulate the musculature of paralyzed seqments and facilitate both the relearning of movement and neuromodulation of tone.

    TrainFES Advanced is a battery-powered, wireless device, configurable from the TRAINFES App, available for Smartphone and Tablets, which allows you to adjust different parameters and follow a training plan from your smartphone. Session settings can be retrieved from the PC or Cloud.

    AI/ML Overview

    The provided document describes the FDA 510(k) premarket notification for the "TrainFES Advanced" device, a neuromuscular electrical stimulator. The purpose of this submission is to demonstrate substantial equivalence to a predicate device (Stella BIO, K210002).

    Here's an analysis of the acceptance criteria and study information provided:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document doesn't explicitly state "acceptance criteria" for the device's performance in a quantitative manner (e.g., target accuracy, sensitivity, specificity). Instead, the substantial equivalence justification relies on demonstrating that the TrainFES Advanced device performs similarly to or meets the safety and effectiveness standards of the predicate device, K210002.

    The table below summarizes the comparison of key technical characteristics between the TrainFES Advanced and its predicate, Stella BIO, highlighting where "performance" is discussed in terms of meeting relevant standards or being considered equivalent. The reported "performance" for TrainFES Advanced is intrinsically linked to its compliance with these standards and the assertion that differences do not raise new safety or effectiveness concerns.

    Characteristic / SpecificationAcceptance Criteria (implied by predicate comparison)Reported Device Performance (TrainFES Advanced)
    Basic Device Characteristics
    ClassificationClass IIClass II
    Prescription/OTC UsePrescription and Home UsePrescription and Home Use
    Environment of UseClinics, hospitals, and homeClinics, hospitals, and home
    Indications for UseSimilar to predicate (specific conditions)Similar to predicate, with specific conditions listed, and the functions of powered muscle stimulator and external functional neuromuscular stimulator are exactly the same
    Power SourceBattery-powered, compliant with IEC 62133Battery: Li-Ion 3.7V (4000mAh), compliant with IEC 62133
    Method of Line Current IsolationN/A (Battery)N/A (Battery)
    Patient leakage current (Normal)<100μA<100μA
    Patient leakage current (Single fault)<100μA<100μA
    Number of Output ModesCompliant with IEC 60601-1 and IEC 60601-2-102, compliant with IEC 60601-1 and IEC 60601-2-10
    Software/Microprocessor controlYesYes
    Automatic Overload TripYesYes
    Automatic No-Load TripYesYes
    Automatic Shut OffYesYes
    Patient Override ControlYesYes (Button)
    Indicator Display On/Off StatusYes (Led)Yes (Led)
    Indicator Display Low BatteryYesYes
    Indicator Display Voltage/Current LevelYesYes
    StandardsCompliance with relevant IEC standardsISO 13485:2016, Bluetooth: FCC 15.2473, IEC 60601-1, IEC 60601-1-2, IEC 60601-2-10, IEC 60601-1-11, IEC 62133, IEC 62304:2015, IEC 62366
    Compliance with 21 CFR 898YesYes
    WeightConsidered acceptable if within safety/effectiveness218 g (considered similar enough to 112g of predicate not to raise safety issues)
    DimensionConsidered acceptable if within safety/effectiveness130 x 79 x 33mm (considered similar enough to 91.5 x 68.4 x 24mm of predicate not to raise safety issues)
    Housing material & ConstructionPlastic (ABS)ABS Plastic
    Apply PartBFBF
    Powered Muscle Stimulator (PMS)
    Number of channelsCompliant with IEC 60601-1 and IEC 60601-2-106 Channels, compliant with IEC 60601-1 and IEC 60601-2-10
    Synchronous or alternatingAlternating or Synchronous (if safety/effectiveness not impacted)Alternating (difference from predicate not impacting essential performance or safety)
    Method of channel isolationMultiplexerMultiplexer
    Regulated Current or voltageRegulated CurrentRegulated Current
    Time Range1 - 60 min1 - 60 min
    WaveformBiphasicBiphasic
    ShapeRectangular, also other shapes for predicateRectangular (tested and compliant with IEC 60601-2-10)
    Symmetrical or asymmetricalSymmetricalSymmetrical
    Maximum voltage outputTested and compliant with IEC 60601-2-1050V @500Ω, 164V @2kΩ, 170V @10kΩ (tested and compliant)
    Maximum output CurrentTested and compliant with IEC 60601-2-10100mA @500Ω, 82 mA @2kΩ, 17 mA @10kΩ (tested and compliant)
    Current output channel0 - 100 mA0 - 100 mA (steps 1mA)
    Pulse Width50 µs - 400 µs50 µs - 400 µs
    Frequency1 - 140 Hz1 - 140 Hz
    Net charge (µC per pulse)0µC (Balanced pulses)0µC (Balanced pulses)
    Max phase charge @500Ω40 µC40 µC
    Maximum current density (mA/cm²) @500ΩComplies with FDA guidance for PMS 510(k)s0.224 mA/cm² (25 cm² electrode area) (complies with FDA guidance)
    max. power density (W/cm²)Complies with FDA guidance for PMS 510(k)s0.00062 W/cm² (25 cm² electrode area) (complies with FDA guidance)
    Functional Electrical Stimulation (FES)
    All FES parametersSame as PMS parameters, with differences justified as not impacting essential performance or safety.Same as PMS parameters, with differences justified as not impacting essential performance or safety.

    2. Sample Size for the Test Set and Data Provenance:

    The document explicitly states: "No clinical testing was performed in support of this submission."
    Therefore, there is no test set in the sense of clinical data from human subjects described in this document. The evaluation relies on non-clinical (bench) testing, comparison to a predicate device, and compliance with recognized standards.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications:

    Given that no clinical testing was performed, there were no "experts" involved in establishing ground truth for a clinical test set from human subjects. The assessment relies on the expertise of the engineers and regulatory professionals who performed the non-clinical testing and drafted the 510(k) submission, confirming compliance with engineering standards.

    4. Adjudication Method for the Test Set:

    Not applicable, as no clinical test set was used.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

    No, an MRMC comparative effectiveness study was not done. The submission relies entirely on non-clinical testing and comparison to a predicate device, without involving human readers or a comparative effectiveness study with AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

    No, this question doesn't directly apply here. The "TrainFES Advanced" is a physical medical device (a neuromuscular electrical stimulator) that includes software control, not an AI algorithm intended for diagnostic or prognostic purposes on its own. The "device performance" is assessed through its electrical and mechanical characteristics and compliance with safety standards, not through an algorithm's standalone interpretative accuracy.

    7. The Type of Ground Truth Used:

    For this device, the "ground truth" for the non-clinical testing is based on:

    • Engineering specifications and regulatory standards: The device is tested against established limits and requirements defined in standards like IEC 60601 series, IEC 62133, IEC 62304, IEC 62366, and ISO 14971.
    • Predicate device characteristics: The predicate device (Stella BIO, K210002) serves as a benchmark for comparison, implying that its established safety and effectiveness characteristics represent a "ground truth" for what is acceptable in this device class.

    8. The Sample Size for the Training Set:

    Not applicable, as no AI/machine learning algorithm training using a specific dataset is referenced or implied in the context of this 510(k) submission for this type of medical device.

    9. How the Ground Truth for the Training Set Was Established:

    Not applicable, as no AI/machine learning algorithm training using a specific dataset is referenced.

    In summary: The submission for TrainFES Advanced demonstrates substantial equivalence primarily through comprehensive non-clinical (bench) testing against recognized industry standards (IEC series, ISO 14971) and a detailed comparison of its technical specifications to a previously cleared predicate device (K210002). The core argument is that any differences in characteristics do not raise new questions of safety or effectiveness. No clinical studies, human reader studies, or AI algorithm performance evaluations against clinical ground truth were conducted or presented in this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K213622

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-02-14

    (90 days)

    Product Code
    Regulation Number
    882.5810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K080950

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cionic Neural Sleeve NS-100 is intended to provide ankle dorsiflexion in adult individuals with foot drop and/or to assist knee flexion or extension in adult individuals with muscle weakness related to upper motor neuron disease /injury (e.g. stroke, damage to the spinal cord). The Cionic Neural Sleeve NS-100 electrically stimulates muscles in the affected leg to provide ankle dorsiflexion of the foot and/or knee flexion or extension; thus, it also may improve the individual's gait.

    The Cionic Neural Sleeve NS-100 may also:

    • Facilitate muscle re-education
    • Prevent/retard disuse atrophy
    • Maintain or increase joint range of motion
    • Increase local blood flow
    Device Description

    The Cionic Neural Sleeve NS-100 is a platform for the measurement and augmentation of lower limb mobility composed of a body-worn legging, a battery-powered electronic controller and a mobile application. The Cionic Neural Sleeve NS-100 has embedded sensors to measure limb movement and muscle activity. These data are used by the control unit to generate stimulation intended to activate muscles for exercise or functional assistance.

    The Cionic Neural Sleeve NS-100 is intended to provide ankle dorsiflexion and/or plantarflexion in adult individuals with foot drop and/or to assist knee flexion or extension in adult individuals with muscle weakness related to upper motor neuron disease/injury (e.g. stroke, damage to pathways to the spinal cord). The Cionic Neural Sleeve NS-100 electrically stimulates muscles in the affected leg to provide ankle dorsiflexion and/or plantarflexion of the foot and/or knee flexion or extension; thus, it also may improve the individual's gait.

    The Cionic Neural Sleeve NS-100 system sales carton consists of the following components:

      1. SL-100 a fabric sleeve covering the upper and lower leg containing embedded motion sensors and skin-contacting electrodes. Left and right leg sleeves are available in two sizes: small, and medium.
      1. DC-100 a portable battery-powered Control and Stimulation Unit that connects to, and is worn within the SL-100. The DC-100 communicates over Bluetooth™Low Energy protocol to the Cionic mobile application ("Cionic app").
      1. Power supply and cable to recharge the DC-100 and connect the DC-100 to a user's computer when required.
      1. Adhesive, electrically conductive and replaceable electrode pads.
      1. Electrode cover sheets.
      1. Instructions for Use documents.

    Components are available as accessories to the Cionic Neural Sleeve NS-100 system:

    • Replacement electrode pads.
      The Cionic Neural Sleeve NS-100 requires a password-protected Cionic mobile application that is exclusively available to Cionic Neural Sleeve NS-100 users.

    The Cionic Neural Sleeve NS-100 system consists of a software and hardware architecture that enables users to access a library exercise and augmentation programs. Programs can be added and removed from the user's mobile app. All exercise and assistance programs utilize a standard calibration and stimulation user interface that is extendible to future exercise and augmentation programs.

    AI/ML Overview

    The provided FDA 510(k) summary for the Cionic Neural Sleeve NS-100 (K213622) does not include a detailed study proving the device meets specific acceptance criteria based on performance metrics such as sensitivity, specificity, accuracy, or effect size for human readers with AI assistance.

    The document focuses on demonstrating substantial equivalence to a predicate device (Bioness L300 Go System, K190285) rather than providing a standalone performance study with quantified acceptance criteria for diagnostic or assistive accuracy. The performance data presented is limited to non-clinical testing for safety and technical specifications, not clinical effectiveness in terms of how well it improves patient outcomes or how it performs against a measurable clinical metric.

    Therefore, many of the requested items cannot be extracted directly from this document. However, I can provide what is available and clarify what is missing.


    Acceptance Criteria and Device Performance (Based on Technical and Safety Testing)

    While the document doesn't list quantitative clinical performance criteria, it outlines the non-clinical tests conducted to demonstrate the device performs as "intended" and is "substantially equivalent." The "reported device performance" in this context refers to its adherence to these technical and safety standards.

    Acceptance Criteria (Implied by non-clinical tests)Reported Device Performance
    Safety and Electrical Performance:Demonstrated Compliance:
    Compliance with IEC 60601-1 (Electrical Safety)Compliant (Implied by "successfully verified/validated," "adhere to recognized/consensus electrical safety standards")
    Compliance with IEC 60601-1-11 (Electrical Safety in Home Healthcare)Compliant (Implied by "successfully verified/validated," "adhere to recognized/consensus electrical safety standards")
    Compliance with IEC 60601-2-10 (Muscle and Nerve Stimulators)Compliant (Implied by "successfully verified/validated," "adhere to recognized/consensus electrical safety standards")
    Compliance with IEC 60601-1-2 (Electromagnetic Compatibility)Compliant
    Battery Safety (IEC 62133-2)Compliant
    Stimulation Output Waveforms meet specificationsPerformed as intended
    Stimulation Output Channels and Isolation meet specificationsPerformed as intended
    Hybrid Stimulation functions as intendedPerformed as intended
    Stimulation Electrodes Short and/or Open detection functions as intendedPerformed as intended
    Biocompatibility:
    Biological evaluation of medical devices according to ISO 10993-1Compliant
    Usability and Software:
    Usability according to IEC 62366; IEC 60601-1-6Compliant ("successfully verified/validated")
    Software validation according to IEC 62304Compliant ("successfully verified/validated")
    Functional/Technological Equivalence (to Predicate):
    Provide ankle dorsiflexion and/or plantarflexion, assist knee flexion or extensionYes, similar indications, with additional plantarflexion capability compared to predicate.
    Facilitate muscle re-education, prevent/retard disuse atrophy, maintain/increase ROM, increase local blood flowYes, similar to predicate.
    Other technological characteristics (e.g., output current, power density, control methods)Found "Substantially equivalent," with differences considered minor and having no impact on safety and effectiveness.

    Detailed Information Regarding Study (Based on Document Analysis):

    1. Sample size used for the test set and the data provenance:

      • Sample Size: Not applicable/not provided in this summary. The document describes non-clinical bench testing and verification/validation processes, not a clinical study on a patient test set with performance metrics.
      • Data Provenance: Not applicable, as it's not a clinical data set. It refers to non-clinical testing performed by the manufacturer, Cionic, Inc.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. Ground truth as typically defined for clinical or diagnostic performance studies is not established in this document, as it outlines technical and safety testing.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • Not applicable. There is no mention of a human-reviewed test set or adjudication process for clinical performance.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No. This is not an MRMC comparative effectiveness study involving human readers or AI assistance in a diagnostic context. The device is a functional neuromuscular stimulator, not an AI-assisted diagnostic tool.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • The document implies extensive standalone engineering verification and validation of the device's electrical, mechanical, software, and biocompatibility aspects. However, this is not a clinical "standalone performance" in the sense of an algorithm making a clinical decision without human intervention. The device's function is to directly stimulate muscles based on detected limb movement.
      • The software was validated according to IEC 62304, and the overall system was "verified and validated successfully for its intended use through a combination of original bench testing and verification and validation of all software and firmware."
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • For the non-clinical testing, the "ground truth" was compliance with established engineering standards (e.g., IEC standards for electrical safety, biocompatibility, usability, software validation) and the device's design specifications. There is no clinical outcomes data or pathology-based ground truth presented in this summary for the purpose of demonstrating substantial equivalence.
    7. The sample size for the training set:

      • Not applicable. This document does not describe an AI/machine learning model that would require a "training set" in the traditional sense for diagnostic or predictive performance. The device uses embedded sensors and a control unit to generate stimulation for functional assistance, implying a rule-based or control-loop system rather than a trained AI classification model.
    8. How the ground truth for the training set was established:

      • Not applicable, as there is no mention of a training set for an AI/machine learning model.

    Summary of Conclusions from the Document:

    The Cionic Neural Sleeve NS-100 underwent comprehensive non-clinical testing, including electrical safety, biocompatibility, usability, and software validation. Based on the results, Cionic Inc. concluded that the device is substantially equivalent to the predicate Bioness L300 Go System. The differences noted, such as the ability to provide plantarflexion and variations in technological characteristics (e.g., number of output modes, power sources, stimulation channels, clinician/user control interfaces, and trigger sources), were deemed "minor with no impact to safety and effectiveness" because they either represented a subset of the predicate's capabilities, adhered to recognized safety standards, or achieved similar functional outcomes through different but validated technological means.

    Ask a Question

    Ask a specific question about this device

    K Number
    K130919

    Validate with FDA (Live)

    Device Name
    SENSUS
    Manufacturer
    Date Cleared
    2013-07-02

    (90 days)

    Product Code
    Regulation Number
    882.5890
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K121059, K121305, K080950

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NeuroMetrix SENSUS is intended for use as a transcutaneous electric nerve stimulation device for the symptomatic relief and management of chronic intractable pain.

    The device may be used during sleep. The device is labeled for use only with the NeuroMetrix SENSUS Electrode.

    Device Description

    The SENSUS device, is a transcutaneous electrical nerve stimulator with a single output mode. The device utilizes a microprocessor running embedded software to control a high-voltage circuit that generates stimulating pulses with specific technical characteristics including pulse shape, amplitude (current), duration, pattern, and frequency. The device is powered by a permanent rechargeable Lithium-Ion battery that is charged through a USB cable connected to an AC adapter.

    The device delivers electrical stimulation to the patient through disposable, single-patient use electrodes placed on the patient's body. The device is labeled for use only with the SENSUS Electrode (K121816), to which it connects through insulated female medical snap connectors embedded within its housing.

    The device has a push-button that initiates stimulation, and controls the intensity. The device has a single two color LED for indication of stimulation status, battery charging, and error conditions.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and study for the NeuroMetrix SENSUS device, based on the provided text:

    Acceptance Criteria and Device Performance

    The primary focus of the study described is the validation of the device's electrode peeling detection feature, which allows the device to be safely used during sleep.

    Acceptance Criteria CategorySpecific Acceptance CriteriaReported Device PerformanceOutcome
    Electrode Peeling DetectionFailure rate of 0%, with the upper bound of the one-sided 95% confidence interval for failure rate being below 5% (i.e., 0 out of 60 tests).0 failures out of 66 tests in two separate protocol runs (total 132 tests).Met
    Device must halt stimulation when remaining skin contact area is less than 3.5 cm².Average remaining contact area was 10.2 ± 2.1 cm² (range 6.9 - 19.5 cm²) for the 10-minute run and 10.1 ± 1.7 cm² (range 7.5 - 18.0 cm²) for the 40-minute run. All reported minimum remaining contact areas (6.9 cm² and 7.5 cm²) are greater than 3.5 cm².Met

    Study Details for Electrode Peeling Detection Validation

    1. Sample Size Used and Data Provenance:

      • Test Set Sample Size: 66 subjects and 132 SENSUS electrodes were used. There were two protocol runs, each with 66 tests, totaling 132 tests. The prospective validation sample size was set to 60 tests to meet the 0% failure rate statistical criterion.
      • Data Provenance: The study was described as "prospective validation," indicating it was specifically designed and conducted for this purpose. The country of origin is not explicitly stated, but NeuroMetrix is based in Waltham, MA, USA, suggesting the study was likely conducted in the USA.
    2. Number of Experts and Qualifications for Ground Truth:

      • The document does not explicitly mention the use of external experts to establish ground truth for the electrode peeling detection test. The "ground truth" for this test was the physical measurement of the electrode area remaining on the skin at the instant stimulation halted, as determined by the study methodology.
    3. Adjudication Method:

      • Not applicable/Not mentioned. The study involved objective measurements of physical parameters (electrode contact area).
    4. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

      • No. This was a technical validation study for a safety feature, not a comparative effectiveness study involving human readers.
    5. Standalone (Algorithm Only) Performance:

      • Yes. The study focused on the automatic performance of the device's embedded algorithm in detecting electrode peeling and halting stimulation. There was no human-in-the-loop component for this safety feature.
    6. Type of Ground Truth Used:

      • Objective Measurement/Engineered Truth: The ground truth was established by direct measurement of the electrode-to-skin contact area at the point where the device halted stimulation. The "failure" condition was defined objectively as the remaining contact area being less than 3.5 cm².
    7. Sample Size for Training Set:

      • Not applicable/Not mentioned. The document describes a validation study for a specific safety mechanism (electrode peeling detection). It does not provide details of any machine learning model training or a "training set" in the context of AI. The device uses "embedded software to control a high-voltage circuit," implying rule-based or control system logic rather than a conventional machine learning model with a distinct training phase.
    8. How Ground Truth for Training Set was Established:

      • Not applicable, as no training set for a machine learning model is described. The device's operational parameters and safety thresholds (like the 3.5 cm² peeling threshold) would have been established through engineering design, risk analysis, and relevant standards, rather than a data-driven training process with a ground truth similar to clinical AI models.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1