Search Filters

Search Results

Found 3 results

510(k) Data Aggregation

    K Number
    K241676

    Validate with FDA (Live)

    Device Name
    TriVerity
    Manufacturer
    Date Cleared
    2025-01-10

    (213 days)

    Product Code
    Regulation Number
    866.3215
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K042613

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TriVerity test is an automated ve in vitro diagnostic test that measures the relative expression levels of host response genes in RNA isolated from whole blood collected in the PAXgene Blood RNA tube using reverse transcription loop-mediated isothermal amplification (RT-LAMP) on the Myrna instrument.

    The TriVerity test is indicated for use in conjunction with clinical assessments and other laboratory findings as an aid to differentiate bacterial infections, viral infections, and non-infectious illness, as well as to determine the likelihood of 7day need for mechanical ventilation, vasopressors, and/or renal replacement with suspected acute infection or suspected sepsis presenting to the emergency department.

    The test generates three scores that each fall within one of five discrete interpretation bands based on the increasing likelihood of

    1. bacterial infection,

    2. viral infection, and

    3. severe illness, as defined by the need for mechanical ventilation, vasopressors, and/ or renal replacement therapy (RRT) within seven days.

    Device Description

    The TriVerity test is an in vitro diagnostic test for simultaneous amplification and detection of 29 informative host response RNA transcripts and 3 housekeeping transcripts (listed in measurands) using total RNA extracted from human blood. The test has been designed, manufactured, and validated for use on the Myrna instrument. The TriVerity test is performed with a TriVerity cartridge, a single-use, disposable, multi-chambered fluidic cartridge that runs on the Myrna instrument. All processing steps are automated and occur within a TriVerity cartridge, including sample extraction/purification and qRT-LAMP for the detection and relative quantification of the 29 informative host response RNA transcripts and 3 housekeeping transcripts (listed in measurands). All cartridge steps in this process, following the addition of the sample, are fully automated and completely integrated. In approximately 30 minutes, the test generates three scores that each fall within one of five discrete interpretation bands based on the increasing likelihood of

      1. bacterial infection,
      1. viral infection, and
      1. severe illness, as defined by the need for mechanical ventilation, vasopressors, and/or renal replacement therapy (RRT) within seven days.

    The specimen used for the TriVerity test is a sample of whole blood collected by venipuncture using the PAXgene blood collection tubes within the PAXgene Blood RNA System (K042613). The cartridge contains all the necessary reagents to perform RNA isolation and subsequent amplification from the sample.

    The TriVerity test quantifies the amount of each transcript in the sample based on the detection of fluorescence by the Myrna instrument. The cartridge includes the reagents for reverse transcription and LAMP. All 32 transcripts (and two in cartridge controls) are amplified and quantified. These values are input to two fixed classifiers which output the three separate scores, each with five discrete interpretation bands. The bands reflect monotonically increasing likelihood of bacterial infection, viral infection, and severe illness, as defined by the need for mechanical ventilation, vasopressors, and/or renal replacement therapy (RRT) within seven days.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study that proves the device meets them, based on the provided FDA 510(k) summary for the TriVerity device:

    TriVerity Device Performance Study Summary

    The TriVerity test is an automated in vitro diagnostic test that measures the relative expression levels of host response genes in RNA isolated from whole blood. It is indicated for use in conjunction with clinical assessments and other laboratory findings as an aid to differentiate bacterial infections, viral infections, and non-infectious illness, and to determine the likelihood of 7-day need for mechanical ventilation, vasopressors, and/or renal replacement therapy (RRT) in adult patients with suspected acute infection or suspected sepsis presenting to the emergency department. The device generates three scores (bacterial, viral, and severe illness) each falling within one of five discrete interpretation bands.


    1. Table of Acceptance Criteria and Reported Device Performance

    The document describes performance in terms of accuracy metrics (PPA, NPA, Likelihood Ratios, AUROC) and analytical performance (reproducibility, linearity, analytical sensitivity, detection limits, analytical specificity). The acceptance criteria for clinical performance are primarily articulated through performance targets for the "Very Low" and "Very High" interpretation bands, aiming to minimize false negatives and false positives, respectively.

    Acceptance Criteria for Clinical Performance (Qualitative, as stated):

    • "Very Low" Band PPA ≥95%: Minimize false negative patients.
    • "Very High" Band NPA ≥95%: Minimize false positive patients.
    • Monotonicity: Likelihood ratios should monotonically increase across interpretation bands.
    • Non-overlapping CIs: 80% CIs for likelihood ratios in non-adjacent bands should not overlap.
    Metric (Outcome)Interpretation BandExpected Result (Acceptance Criteria per document)Reported Device Performance (Forced Adjudication)Reported Device Performance (Consensus Adjudication)
    Bacterial Infection
    PPAVery Low≥95%95.7%97.2%
    NPAVery High≥95%94.2%95.5%
    LR (Bacterial)All BandsMonotonically Increasing; Non-overlapping CIs0.16 (VL) to 5.24 (VH); CIs non-overlapping0.08 (VL) to 8.04 (VH); CIs non-overlapping
    AUROCOverallHigh0.760.83
    Viral Infection
    PPAVery Low≥95%88.7%95.5%
    NPAVery High≥95%97.7%98.6%
    LR (Viral)All BandsMonotonically Increasing; Non-overlapping CIs0.25 (VL) to 20.04 (VH); CIs non-overlapping0.09 (VL) to 40.93 (VH); CIs non-overlapping
    AUROCOverallHigh0.830.91
    Severe Illness(Prognostic Endpoint)N/A
    PPAVery Low≥95% (Implicitly, to minimize false negatives)91.8%N/A
    NPAVery High≥95% (Implicitly, to minimize false positives)98.7%N/A
    LR (Severity)All BandsMonotonically Increasing; Non-overlapping CIs0.22 (VL) to 11.33 (VH); CIs non-overlappingN/A
    AUROCOverallHigh0.78N/A

    Note: "Very Low" (VL), "Low" (L), "Moderate" (M), "High" (H), "Very High" (VH). PPA (Positive Percent Agreement), NPA (Negative Percent Agreement), LR (Likelihood Ratio), AUROC (Area Under the Receiver Operating Characteristic curve).

    2. Sample Sizes and Data Provenance

    • Test Set (Clinical Study - SEPSIS-SHIELD; NCT04094818):
      • Total Consented: 1,441 participants.
      • Evaluable for Diagnostic Endpoint: 1,222 participants (for bacterial and viral infection differentiation).
      • Evaluable for Prognostic Endpoint: 1,120 participants (for severe illness prediction).
      • Provenance: Prospective, multi-center clinical study conducted in twenty-one geographically diverse locations throughout the United States plus one site in Europe.
      • Data Type: Clinical data and biological samples collected from participants with suspected acute infection or suspected sepsis presenting to the emergency department.

    3. Number of Experts and Qualifications for Ground Truth

    • The document mentions "consensus and forced clinical adjudication" for establishing ground truth for bacterial and viral infections, but it does not specify the number or qualifications of the experts involved in this adjudication process. This information is typically detailed in the study protocol or full clinical study report.

    4. Adjudication Method

    • Forced Adjudication: All patients were adjudicated as "Yes" and/or "Probable" vs. "No" and/or "Unlikely" for bacterial and viral infection.
    • Consensus Adjudication: Only participants with a "certain (Yes or No)" infection status were included. This inherently excludes "Probable" and "Unlikely" cases, leading to a smaller, more definitive ground truth dataset. The document explicitly states that "higher accuracy results were observed when applying the consensus adjudication as the reference standard... due to the exclusion of participants with uncertain (Probable and Unlikely) bacterial infection status."

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No MRMC comparative effectiveness study was mentioned in this summary. The device is an in vitro diagnostic test that provides scores, not an AI-assisted diagnostic tool for human readers (e.g., radiology AI). The study focuses on the standalone performance of the device against clinical adjudication and compares its performance to traditional biomarkers (PCT, CRP, WBC, Lactate, qSOFA).

    6. Standalone Performance

    • Yes, standalone performance was done. The entire clinical study (SEPSIS-SHIELD) evaluates the diagnostic and prognostic performance of the TriVerity test on its own, providing scores that are interpreted by clinicians as an aid for diagnosis and prognosis. The device outputs scores, and its accuracy is measured against clinical ground truth.

    7. Type of Ground Truth Used

    • Expert Consensus/Clinical Adjudication: For bacterial and viral infection differentiation. This involves clinical assessment and other laboratory findings.
    • Outcomes Data: For severe illness prediction, defined as the "need for mechanical ventilation, vasopressors, and/or renal replacement therapy (RRT) within seven days."

    8. Sample Size for the Training Set

    • The document states that "Illness Severity Score thresholds were set (tuned) using predicted probabilities and ground truths for 399 patient samples collected from Emergency Department settings."
    • "Bacterial and Viral Score thresholds were tuned using predicted probabilities and ground truths for 472 patient samples collected from Emergency Department and ICU studies."
    • These tuning studies were described as "independent from the final clinical study (INF-04)".

    9. How Ground Truth for the Training Set was Established

    • The ground truth for the training (tuning) sets was established using "predicted probabilities and ground truths" from patient samples collected from Emergency Department and ICU studies. While the document doesn't explicitly detail the method of ground truth establishment for these specific tuning sets (e.g., expert adjudication, culture results), it implies a similar clinical assessment as used for the test set, given they are designated as "ground truths." It also notes these samples were collected in PAXgene blood tubes and processed on the Myrna instrument using GMP-grade TriVerity cartridges, indicating they were real patient samples with associated clinical outcomes or diagnoses.
    Ask a Question

    Ask a specific question about this device

    K Number
    K203748

    Validate with FDA (Live)

    Device Name
    SeptiCyte RAPID
    Manufacturer
    Date Cleared
    2021-11-29

    (341 days)

    Product Code
    Regulation Number
    866.3215
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K042613

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SeptiCyte ® RAPID test is a gene expression assay using reverse transcription polymerase chain reaction to quantify the relative expression levels of host response genes isolated from whole blood collected in the PAXgene ® Blood RNA Tube. The SeptiCyte ® RAPID test is used in conjunction with clinical assessments and other laboratory findings as an aid to differentiate infection-positive (sepsis) from infectionnegative systemic inflammation in patients suspected of sepsis on their first day of ICU admission. The SeptiCyte ® RAPID test generates a score (SeptiScore®) that falls within one of four discrete Interpretation Bands based on the increasing likelihood of infectionpositive systemic inflammation. SeptiCyte ® RAPID is intended for in-vitro diagnostic use on the Biocartis IdyllaTM System.

    Device Description

    SeptiCyte RAPID is an in vitro diagnostic test for simultaneous amplification and detection of two RNA transcripts (PLA2G7 and PLAC8) using total RNA extracted from human blood. The test has been designed, manufactured, and validated for use on the Biocartis Idylla real-time PCR system. The SeptiCyte RAPID test is performed with an Idylla Cartridge, a single-use, disposable, multi-chambered fluidic cartridge that runs on the Biocartis Idylla System. In an automated fashion, all reaction steps take place within the cartridge, including sample extraction/purification, RT-qPCR for the detection and relative quantification of the two human mRNA targets PLAC8. PLA2G7. Test results (measured Cg values and calculated SeptiScore) are available in about 65 minutes.

    The specimen used for the SeptiCyte RAPID is a sample of whole blood collected in a PAXgene blood RNA tube (FDA 510k number K042613). The cartridge contains all of the necessary reagents to perform RNA isolation from the sample.

    SeptiCyte RAPID uses quantitative, real-time determination of the amount of each transcript in the sample based on the detection of fluorescence by the Biocartis Idylla qPCR instrument function. The cartridge includes the reagents for reverse transcription and PCR. Transcripts PLAC8 and PLA2G7 are amplified and quantified. These values are combined to produce the SeptiScore, which is interpreted and categorized into four discrete bands, which are associated with a sequentially higher likelihood of sepsis.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study details for the Immunexpress, Inc. SeptiCyte RAPID device, based on the provided FDA 510(k) summary:

    1. Acceptance Criteria and Reported Device Performance

    The clinical studies for SeptiCyte RAPID had the following acceptance criteria for the primary endpoint:

    1. A monotonic increase in the probability of sepsis across the four SeptiScore interpretation bands.
    2. Non-overlapping 80% confidence intervals for the probability of sepsis between non-adjacent SeptiScore interpretation bands (i.e., between bands 1 and 3; and between bands 2 and 4).

    Here's the performance reported using the Forced RPD Method (as it covers the full dataset and shows the trend across all bands):

    SeptiScore Interpretation BandAcceptance Criteria 1: Monotonic Increase (Observed Probability of Sepsis)Acceptance Criteria 2: Non-overlapping 80% Confidence Intervals (Observed Probability)
    Band 1 (0 - 4.9)0.12(0.08 - 0.18)
    Band 2 (5.0 - 6.1)0.24(0.18 - 0.3)
    Band 3 (6.2 - 7.3)0.48(0.4 - 0.56)
    Band 4 (7.4 - 15.0)0.80(0.74 - 0.84)

    Proof of Acceptance:
    The reported device performance demonstrates:

    1. Monotonic Increase: The observed probabilities of sepsis (0.12, 0.24, 0.48, 0.80) clearly increase monotonically across the four bands, meeting the first criterion.
    2. Non-overlapping 80% Confidence Intervals:
      • Band 1 (0.08 - 0.18) vs. Band 3 (0.4 - 0.56): The intervals do not overlap.
      • Band 2 (0.18 - 0.3) vs. Band 4 (0.74 - 0.84): The intervals do not overlap.
        This meets the second criterion.

    The analysis using Consensus and Unanimous RPD methods also showed similar results, fulfilling the acceptance criteria.

    2. Sample Size and Data Provenance for the Test Set

    • Sample Size: N = 386
      • N = 356 from retrospective studies
      • N = 30 from a prospective study
    • Data Provenance:
      • Retrospective Study: Netherlands-based Molecular diagnosis And Risk Stratification of sepsis (MARS) clinical trial (NCT01905033)
      • Retrospective Study: USA-based Validation of septic gene Expression Using SeptiCyte (VENUS) clinical trial (NCT02127502)
      • Prospective Study: USA-based NEar PatienT MolecUlar TestiNg in Sepsis (NEPTUNE) clinical trial

    3. Number of Experts and Qualifications for Ground Truth Establishment

    • Number of Experts: Three-member expert panel.
    • Qualifications of Experts: Not explicitly stated beyond "external three-member expert panel not involved in the care of the patients." It does not specify their medical specialty (e.g., critical care physicians, infectious disease specialists) or years of experience.

    4. Adjudication Method for the Test Set

    Three different methods of Retrospective Physician Diagnosis (RPD) were used:

    • Consensus: Two or three RPD panelists agree that the patient is either sepsis or SIRS. Indeterminates are excluded.
    • Unanimous: All three RPD panelists, as well as the consensus discharge evaluation of the site investigators, agree that the patient is either sepsis or SIRS.
    • Forced: Applied to patients initially called "indeterminate" by RPD panelists. The panelists are then forced to make a consensus or unanimous call of sepsis or SIRS.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not performed. The device is an in vitro diagnostic (IVD) assay that provides a score to aid in diagnosis, not an imaging AI or a system designed to assist human readers in interpretation. Therefore, the question of human readers improving with AI vs. without AI assistance is not applicable in this context.

    6. Standalone Performance Study

    Yes, a standalone performance study was done. The entire clinical evaluation is based on the SeptiCyte RAPID test (algorithm only) generating a SeptiScore and its associated interpretation bands. The clinical studies aim to validate the device's ability to differentiate infection-positive (sepsis) from infection-negative systemic inflammation based solely on its output.

    7. Type of Ground Truth Used

    The ground truth used was expert consensus or retrospective physician diagnosis (RPD). This involved an external three-member expert panel reviewing clinical cases to determine whether a subject's clinical status was SIRS, sepsis, or indeterminate.

    8. Sample Size for the Training Set

    The document does not explicitly state a separate sample size for a training set. The clinical studies described (MARS, VENUS, NEPTUNE) were primarily for validation and 510(k) clearance of the already developed SeptiCyte RAPID test. It's common for gene expression assays to be developed using earlier research cohorts, but this document focuses on the validation of the specific device. The clinical studies might have been used for final validation and refinement of the SeptiScore cut-offs, but a distinct "training set" for the algorithm itself is not mentioned here.

    9. How the Ground Truth for the Training Set Was Established

    As a distinct training set is not explicitly detailed, the method for establishing its ground truth is also not described. However, given that the clinical validation ground truth was established by expert consensus/RPD, it is highly probable that any development or training earlier in the product lifecycle would have used similar methodologies.

    Ask a Question

    Ask a specific question about this device

    K Number
    K163260

    Validate with FDA (Live)

    Device Name
    SeptiCyte LAB
    Manufacturer
    Date Cleared
    2017-02-17

    (88 days)

    Product Code
    Regulation Number
    866.3215
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K042613, K082562

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    SeptiCyte™ LAB is a gene expression assay using reverse transcription polymerase chain reaction to quantify the relative expression levels of host response genes isolated from whole blood collected in the PAXgene™ Blood RNA Tube. SeptiCyte™ LAB is used in conjunction with clinical assessments and other laboratory findings as an aid to differentiate infection-positive (sepsis) from infection-negative systemic in patients suspected of sepsis on their first day of ICU admission. The test generates a score (SeptiSCORE™) that falls within one of four discrete Interpretation Bands based on the increasing likelihood of infection-positive systemic inflammation. SeptiCyte™ LAB is in-vitro diagnostic use.

    Device Description

    SeptiCyte™ LAB is an in vitro diagnostic test to be used when prescribed by a clinician in professional settings such as central hospital laboratories. SeptiCyte™ LAB is a reverse transcription quantitative polymerase chain reaction (RT-gPCR)-based laboratory test that quantifies the relative expression levels of four host response genes (CEACAM4, LAMP1, PLA2G7, PLAC8) using RNA extracted from the whole blood of critically ill patients suspected of sepsis. It is a kit developed specifically for the Applied Biosystems® 7500 Fast Dx Real-Time PCR System. SeptiCyte™ LAB serves as an indicator of the host response to infection in systemically inflamed patients by measuring the expression of specific genes with roles in immune function, and infection. More specifically it aids in differentiating infection-positive systemic inflammation (IPSI) from infection-negative systemic inflammation (INSI).

    SeptiCyte™ LAB measures the relative expression levels of the four genes by threshold cycle (Ct) in RT-qPCR. Ct values are linearly combined in a SeptiSCORE™ ranging from 0 to 10 by SeptiCyte™ Analysis software. The higher the SeptiSCORE™ value, the greater the likelihood of IPSI; the lower the SeptiSCORE™, the less likely the condition is caused by infection (INSI).

    AI/ML Overview

    The provided text describes the SeptiCyte™ LAB device, an in vitro diagnostic test for aiding in the differentiation of infection-positive (sepsis) from infection-negative systemic inflammation in patients suspected of sepsis.

    Here's the breakdown of the acceptance criteria and study details:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state "acceptance criteria" with specific numerical thresholds for performance metrics. Instead, it describes "Primary Endpoint" and "Secondary Endpoint" which the clinical study "met." I will use these endpoints as the de facto acceptance criteria.

    Acceptance Criteria (Endpoint)Reported Device Performance
    Primary Endpoint: Demonstration that SeptiSCORE™ correlates with probability of sepsis across each SeptiSCORE™ Interpretation Band. Non-adjacent SeptiSCORE™ Interpretation Bands should display non-overlapping 80% confidence intervals (Cls) with respect to sepsis probability.The clinical data exhibited a direct relationship between SeptiSCORE™ and the probability of sepsis across each SeptiSCORE™ Interpretation Band. Non-adjacent SeptiSCORE™ Interpretation Bands displayed non-overlapping 80% confidence intervals (Cls) with respect to sepsis probability. (The study met this endpoint.)
    Secondary Endpoint: Demonstration that SeptiSCORE™ is a significant component of a logistic regression model of sepsis diagnosis, providing diagnostic clinical utility beyond that provided by combinations of other clinical variables and laboratory assessments.The SeptiSCORE™ was always a significant component of the logistic regression models built to classify infection-positive (sepsis) and infection-negative (SIRS/INSI) patients, regardless of whether PCT was available as a variable. SeptiSCORE™ was also the top-ranked variable in all sepsis diagnosis backward-elimination models. (The study met this endpoint.)

    2. Sample size used for the test set and the data provenance

    • Sample Size: 447 adult patients
    • Data Provenance: Observational, prospective clinical trials conducted across eight clinical sites in the US and Europe.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of Experts: Three medical experts.
    • Qualifications of Experts: Assumed to be medical professionals with expertise in critically ill patients and sepsis diagnosis, as they were referred to as an "RPD panel" and "medical experts" providing "independent clinical case review." Specific experience duration (e.g., "10 years experience") is not provided.

    4. Adjudication method for the test set

    The adjudication method involved a "majority opinion of three medical experts."

    • Consensus RPD: Subjects were stratified by diagnosis (SIRS, Sepsis, or Indeterminate) according to the majority opinion. Indeterminate cases (n=37) were excluded from the analysis.
    • Forced RPD: Subjects were stratified by diagnosis (SIRS or Sepsis) according to the majority opinion, with no Indeterminate category allowed, forcing all patients into either SIRS or sepsis categories.

    This closely resembles a 3+1 or simply majority consensus method, where at least two out of three experts had to agree for a definitive diagnosis.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No, a multi-reader multi-case (MRMC) comparative effectiveness study focusing on human readers' improvement with AI assistance was not done. The study evaluated the standalone performance of the SeptiCyte™ LAB device in relation to a retrospective physician diagnosis, and its contribution to logistic regression models alongside other clinical variables. There is no mention of human readers interpreting images or data with and without AI assistance.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Yes, the primary and secondary endpoints evaluate the performance of the SeptiSCORE™ (generated by the device's algorithm) as a standalone diagnostic aid. The SeptiSCORE™ was compared against a ground truth established by medical experts (RPD). The logistic regression models also assessed the SeptiSCORE's contribution amongst other variables, indicating its standalone diagnostic utility.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth used was expert consensus (Retrospective Physician Diagnosis or RPD), established by a panel of three medical experts. This diagnosis was made after the patient was discharged from the hospital and after all clinical information was available at discharge, and the experts were blinded to the SeptiCyte™ LAB test results.

    8. The sample size for the training set

    The document does not specify the sample size for a training set. The clinical study described involved 447 patients, which served as the evaluation (test) set for the device's performance. Information about a separate training set used to develop the SeptiSCORE™ algorithm is not provided in this document.

    9. How the ground truth for the training set was established

    Since the document does not mention a specific training set or its sample size, it does not describe how ground truth for a training set was established.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1