510(k) Data Aggregation

    K Number
    K171729

    Validate with FDA (Live)

    Device Name
    Fixtemp C&B
    Date Cleared
    2017-12-13

    (184 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K122039, K033022, K042820, K013674

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Fixtemp® C&B is a resin based material used to fabricate temporary crowns and bridges.

    Device Description

    Fixtemp® C&B is a two-component automatically mixable composite on the basis of multifunctional (meth)acrylates provided in standard double cartridges. The material is dispensed and mixed by cartridge/mixing tip combination and it is used for the manufacturing of temporary crowns and bridges for use until the permanent restoration is fabricated. It can be also used for inlays, onlays and veneers and is available in tooth-colors A1, A2, A3, A3.5, B1, Bleach X and D2. This is a prescription only material. The labeling and working instructions are designed for health care professionals.

    AI/ML Overview

    Acceptance Criteria and Device Performance for Fixtemp® C&B

    The Fixtemp® C&B device is a resin-based material used to fabricate temporary crowns and bridges. Its performance was evaluated against a set of non-clinical criteria to establish substantial equivalence to a predicate device.

    1. Table of Acceptance Criteria and Reported Device Performance

    CharacteristicAcceptance Criteria (or Reference Standard)Reported Device Performance
    Working / Processing time≥ 45 sec≥ 45 sec
    Curing time in mouth (flexible phase)≥ 2 - 3 min≥ 2 - 3 min
    Setting time≥ 6 min≥ 6 min
    Hardness (1h)≥ 75 Shore D≥ 75 Shore D
    Hardness (24h)≥ 80 Shore D≥ 80 Shore D
    Compressive strength≥ 200 MPa (according to DIN EN ISO 4049:2010)≥ 200 MPa (according to DIN EN ISO 4049:2010)
    Flexural strength≥ 60 MPa (according to DIN EN ISO 4049:2010)≥ 60 MPa (according to DIN EN ISO 4049:2010)
    E-modulus> 1500 (according to DIN EN ISO 4049:2010)> 1500 (according to DIN EN ISO 4049:2010)
    Water absorptionPass (according to DIN EN ISO 4049:2010)Pass (according to DIN EN ISO 4049:2010)
    Radiopacity≥ 1.00 mm aluminium/mm material (according to DIN EN ISO 4049:2010)≥ 1.00 mm aluminium/mm material (according to DIN EN ISO 4049:2010)
    CytotoxicityNo biological reactivity (Grade 0) based on ISO 10993-5No biological reactivity (grade 0) of the cells exposed to the test article. (Test report: "Toxikon Europe Final GLP Report: 17-01389-G1")
    Carcinogenic potentialNo evidence for causing cancer within the time period of use (up to 29 days)Different evaluations and assessments have been made for cured Fixtemp® C&B and they have shown that there is no evidence for causing cancer within the time period of use in the patients mouth for up to 29 days.
    Mutagenic potentialNo evidence for mutagenic reactions within the time period of use (up to 29 days)Different evaluations and assessments have been made for cured Fixtemp® C&B and they have shown that there is no evidence for mutagenic reactions within the time period of use in the patients mouth for up to 29 days.
    Irritating potentialNo evidence for irritation within the time period of use (up to 29 days)Different evaluations and assessments have been made for cured Fixtemp® C&B and they have shown that there is no evidence for irritation within the time period of use in the patients mouth for up to 29 days.
    Sensitizing potentialNo evidence for sensitization within the time period of use (up to 29 days)Different evaluations and assessments have been made for cured Fixtemp® C&B and they have shown that there is no evidence for sensitization within the time period of use in the patients mouth for up to 29 days.
    Shelf life2 yearsThe results of stability tests at 23 °C/37 °C justify to assume a shelf life of 2 years for Fixtemp® C&B.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the specific sample sizes used for each individual test (e.g., number of specimens for compressive strength). It generally refers to "a series of in-house tests" and adherence to specific ISO standards (e.g., DIN EN ISO 4049:2010).

    For the cytotoxicity testing, the test was conducted by the independent laboratory Toxikon Europe. The provenance of the data is indicated as "Toxikon Europe Final GLP Report: 17-01389-G1". The country of origin for the manufacturing company (Dreve Dentamid GmbH) is Germany. It is implied that these are prospective tests performed on the Fixtemp® C&B material.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    This information is not provided in the document. The performance evaluation relies on standardized tests (e.g., ISO standards) and laboratory findings rather than expert consensus on a test set in the typical sense of diagnostic imaging or clinical studies. The cytotoxicity test was conducted by an "independent laboratory," but the qualifications of the individuals establishing the ground truth (i.e., interpreting the cytotoxicity results) are not detailed.

    4. Adjudication Method for the Test Set

    Not applicable. The reported tests are objective measurements based on standardized procedures and laboratory analysis, not subjective interpretations requiring adjudication by multiple experts.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No MRMC comparative effectiveness study was done. This type of study is typically performed for diagnostic devices where human readers interpret medical images or data. Fixtemp® C&B is a material for fabricating dental prosthetics, and its performance is evaluated through material properties and biocompatibility, not reader interpretation.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    Not applicable. Fixtemp® C&B is a dental material, not an algorithm or software. Its performance is inherent to its physical and chemical properties.

    7. The Type of Ground Truth Used

    The ground truth for the performance tests consists of:

    • Standardized measurement directly from testing: This applies to properties like working time, curing time, setting time, hardness, compressive strength, flexural strength, E-modulus, water absorption, and radiopacity, where the "ground truth" is a measured physical or chemical property that meets or exceeds a predefined numerical threshold from an established standard (e.g., DIN EN ISO 4049:2010).
    • Laboratory findings: For cytotoxicity, the ground truth is established by the results of the ISO 10993-5 test conducted by an independent laboratory, indicating the absence of biological reactivity.
    • Evaluations and assessments: For carcinogenic, mutagenic, and irritating/sensitizing potentials, the ground truth is based on "different evaluations and assessments" indicating no evidence of these effects within the specified time frame. While the specifics of these evaluations are not detailed, they likely rely on established toxicological principles and potentially other in-vitro or in-vivo studies not explicitly listed.

    8. The Sample Size for the Training Set

    Not applicable. Fixtemp® C&B is a physical material, not an AI model or software that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for this device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K073296

    Validate with FDA (Live)

    Device Name
    TEMPXN28
    Date Cleared
    2008-01-09

    (47 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K033022, K013674, K992645

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Fabrication of temporary crowns, bridges, inlays, onlays and veneers.
    Fabrication of long-lasting temporary restorations. Lining material for prefabricated temporary crowns made of composite and metal.

    Device Description

    TempXN28 is a temporary crown and bridge resin intended to make a temporary prosthesis, such as a crown or bridge, for use until a permanent restoration is fabricated. Temporary crown and bridge resin is designated at 21 C.F.R § 872.3770 as a Class II device.
    Like Protemp™ 3 Garant™, TempXN28 is available in the proven Garant™ mixing and dispensing system.

    AI/ML Overview

    The provided text is a 510(k) Summary for a dental material (TempXN28) and not a study describing the performance of an AI/ML powered device. As such, the requested information pertaining to AI/ML device acceptance criteria, study design, and performance metrics (e.g., sample size for test set, ground truth establishment, MRMC studies, standalone performance) is not available in the given document.

    The document discusses the safety and effectiveness of the dental material TempXN28 by demonstrating its substantial equivalence to predicate devices (Protemp™ 3 Garant™, Luxatemp Fluorescence, and Sinfony).

    Here's what can be extracted and what cannot:

    1. A table of acceptance criteria and the reported device performance:

    • Acceptance Criteria: Not explicitly stated as quantifiable metrics for a software/AI device. For this dental material, acceptance criteria would typically involve biocompatibility, mechanical properties (e.g., flexural strength, wear resistance), polishability, color stability, and ease of use, all within acceptable ranges or comparable to predicate devices.
    • Reported Device Performance: The document generally states: "To provide evidence for safety biocompatibility testing was carried out. The results show that TempXN28 is a safe device. The comparison for chemistry, performance data and indications for use shows that TempXN28 is substantially equivalent to the predicate devices."
      • No specific performance values (e.g., strength in MPa, fill rate, etc.) are provided in this summary.
    Acceptance Criteria (Implied for Dental Material Equivalence)Reported Device Performance (Implicit from Summary)
    Biocompatibility (Safety)Biocompatibility testing carried out, results show TempXN28 is a safe device.
    Performance Data (e.g., mechanical, chemical properties)Comparison for chemistry and performance data shows substantial equivalence to predicates.
    Indications for UseSubstantially equivalent to predicate devices for stated indications.

    The following questions cannot be answered from the provided text as they relate to AI/ML device evaluation, which is not the subject of this 510(k) summary:

    1. Sample size used for the test set and the data provenance.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts.
    3. Adjudication method for the test set.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, and the effect size.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.).
    7. The sample size for the training set.
    8. How the ground truth for the training set was established.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1