Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K243410

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-01-30

    (90 days)

    Product Code
    Regulation Number
    866.3385
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The simpli-COLLECT STI Test is a test system intended for in vitro detection and identification of Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), Trichomonas vaginalis (TV), and Mycoplasma genitalium (MG) in home-collected specimens. The specimens are shipped to a clinical laboratory for testing using the Alinity m STI Assay with the automated Alinity m System for the direct, qualitative detection and differentiation of ribosomal RNA from CT, DNA from NG, ribosomal RNA from TV, and ribosomal RNA from MG, to aid in the diagnosis of disease(s) caused by infection from these organisms. The assay may be used to test the following self-collected specimens from symptomatic and asymptomatic individuals for the following analytes:

    • · CT: vaginal swabs, female urine and male urine .
    • NG: vaginal swabs, female urine, and male urine .
    • . · TV: vaginal swabs, female urine and male urine
    • . • MG: vaginal swabs and male urine

    The simpli-COLLECT STI Test contains all the necessary components for the selfcollection and transport of urine from male and female patients (simpli-COLLECT Urine Collection Kit) or vaginal swabs from female patients (simpli-COLLECT Swab Collection Kit) in their home, or in similar environments. The simpli-COLLECT Collection Kits may also be used to self-collect specimens in a clinic.

    Device Description

    The simpli-COLLECT STI Test is a test system intended for in vitro detection and identification of Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), Trichomonas vaginalis (TV), and Mycoplasma genitalium (MG) in home-collected specimens (simpli-COLLECT Urine Collection Kit [09N93001] and the simpli-COLLECT Swab Collection Kit [09R02-001]).

    This test system uses the Alinity m STI Assay (cleared under K202977 and K222379) for real time RT-PCR to amplify and detect Chlamydia trachomatis (CT) ribosomal RNA sequences, Neisseria gonorrhoeae (NG) genomic DNA sequences, Trichomonas vaginalis (TV) ribosomal RNA sequences, Mycoplasma genitalium (MG) ribosomal RNA sequences, and human genomic DNA sequences that have been extracted from vaginal swab specimens or male and female urine specimens.

    The Alinity m STI assay requires two separate assay-specific kits as follows:

    • . Alinity m STI AMP Kit (09N17-095), which consists of multi-well amplification plates containing lyophilized, unit-dose RT-PCR amplification/detection reagents, and multi-well activator plates containing liquid, unit-dose activation reagents (MgC12. TMAC, and KC1). The intended storage condition for the Alinity m STI AMP Kit is 2°C to 8°C.
    • . Alinity m STI CTRL Kit (09N17-085), which consists of negative controls and positive controls, each supplied as liquid in single-use tubes. The intended storage condition for the Alinity m STI Control Kit is -15°C to -25°C.

    The steps of the Alinity m STI assay consist of sample preparation. RT-PCR assembly, amplification/detection, and result calculation and reporting. All stages of the Alinity m STI assay procedure are executed automatically by the Alinity m System. No intermediate processing or transfer steps are performed by the user. The Alinity m System is designed to be a random-access analyzer that can perform the Alinity m STI assay in parallel with other Alinity m assays on the same instrument.

    Nucleic acids from specimens are extracted automatically on-board the Alinity m System using the Alinity m Sample Prep Kit 1, Alinity m Lysis Solution, Alinity m Ethanol Solution or Alinity m Bottle for Ethanol Use filled with Ethanol supplied by customers, and Alinity m Diluent Solution. The Alinity m System employs magnetic microparticle technology to facilitate nucleic acid capture, wash, and elution. The resulting purified nucleic acids are then combined with the liquid unit dose activator reagent, lyophilized unit-dose Alinity m STI amplification reagents, and Alinity m Vapor Barrier Solution, and transferred by the instrument to an amplification/detection module for reverse transcription, PCR amplification, and real-time fluorescence detection.

    Assay controls are tested at or above an established minimum frequency to help ensure that instrument and reagent performance remain satisfactory. During each control event, a negative control and a positive control are processed through sample preparation and RT-PCR procedures that are identical to those used for specimens. Assay controls are used to demonstrate proper sample processing and assay validity. The CTRL kit configuration includes 12 vials at 0.47 mL of both the Alinity m STI Negative CTRL and Alinity m STI Positive CTRL.

    The Alinity m STI amplification reagents include primers and probes that amplify and detect the single copy human gene, ß-globin. Amplification and detection of the ß-globin gene demonstrates proper sample processing and adequate sample input. In addition, an exogenous internal control (containing an armored RNA sequence) is included in the lyophilized Alinity m STI amplification reagents and is used to confirm that no PCR inhibitors are present in the sample. The ß-globin control and internal control are both used to demonstrate assay validity. The AMP kit configuration includes 4 trays (96 tests per tray) of both an AMP TRAY 1 and ACT TRAY 2. The AMP Kit provides sufficient reagents for 384 tests.

    The simpli-COLLECT Urine Collection Kit is used to collect, stabilize, and transport male urine specimens for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae. Trichomonas vaginalis, and Mycoplasma genitalium, and female urine specimens for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis. Each kit can be used to collect 1 urine specimen. The collected specimens are intended for testing with the Alinity m STI assay. The simpli-COLLECT Urine Collection Kit contains the following components: 1 Abbott Sample Collection pack, which contains 1 Alinity m Sample Tube with Liguid Buffer and 1 Transfer Pipette, 1 Tube and Bag Label Sheet, 1 Urine Cup/Urine Collection Cup, 1 simpli-COLLECT Urine Collection Kit Patient Instructions For Use, 1 Biohazard Bag with Absorbent Pad, 1 Tube and Cap Holder, and 1 simpli-COLLECT Urine Collection Kit Box.

    The simpli-COLLECT Swab Collection Kit is used to collect, stabilize, and transport vaginal swab specimens for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis, and Mycoplasma genitalium. Each kit can be used to collect 1 vaginal swab specimen. The collected specimens are intended for testing with the Alinity m STI assay. The simpli-COLLECT Swab Collection Kit contains the following components: 1 Abbott Swab Collection pack, which contains 1 Alinity m Sample Tube with Liguid Buffer and 1 Specimen Collection Swab, 1 Tube and Bag Label Sheet, 1 Biohazard Bag with Absorbent Pad, 1 Tube and Cap Holder, 1 simpli-COLLECT Swab Collection Kit Patient Instructions For Use, and 1 simpli-COLLECT Swab Collection Kit Box.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the simpli-COLLECT STI Test, based on the provided FDA 510(k) summary:

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided document details the performance in terms of usability and absence of interference, rather than specific quantitative diagnostic accuracy metrics (like sensitivity/specificity) for the simpli-COLLECT STI Test itself. The diagnostic accuracy is implicitly covered by the reference to the cleared Alinity m STI Assay (K202977 and K222379).

    Acceptance Criteria CategoryReported Device Performance
    Human Factors/Usability (Lay Users)Lay users are able to collect and ship urine and vaginal swab specimens with minimal error using the simpli-COLLECT Urine Collection Kit and simpli-COLLECT Swab Collection Kit. User label comprehension was also demonstrated to be easy to understand by lay users. (Pass)
    Interference by Hand ContaminantsNo interference observed in the presence of 9 out of 11 tested hand contaminants at specified concentrations. Limitations for assay use were identified for Purell Advanced Hand Sanitizer, Germ X Advanced Moisturizing Hand Sanitizer with Aloe (at concentrations >0.1% v/v in urine and swab matrix), and Vaseline Intensive Care Deep Restore Lotion (at concentrations >0.5% v/v in urine matrix). These limitations are reflected in assay labeling. (Pass, with noted limitations addressed in labeling)

    2. Sample Size Used for the Test Set and Data Provenance

    • Human Factors Study:

      • Sample Size: 223 participants.
      • Data Provenance: Prospective, simulated home environment study conducted in the United States.
    • Interference Study:

      • Sample Size: Not explicitly stated as a number of "samples" but involved testing 11 potential hand contaminants diluted into negative or positive swab and urine matrices. The number of replicates for each condition is not specified in this summary.
      • Data Provenance: Laboratory study, likely conducted internally by Abbott Molecular.
    • Clinical Performance (Reference to K202977 & K222379):

      • The document states that "Performance characteristics of the Alinity m STI assay with swab and urine specimens were established in a multicenter clinical study conducted in the United States to support the clearance of K202977 and K222379." The sample sizes for these previous clearances are not detailed in the provided K243410 summary.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of those Experts

    This information is not directly stated for the specific studies presented in this document (Human Factors and Interference).

    • For the Human Factors study, "ground truth" was evaluated by observing participants' actions and evaluating packaged samples for errors based on laboratory accessioning criteria. This doesn't involve medical experts establishing diagnostic ground truth.
    • For the Interference study, "ground truth" refers to the known positive or negative status of the spiked matrices, against which assay performance (presence/absence of interference) was assessed. This is laboratory-controlled.
    • For the underlying Alinity m STI assay (K202977 and K222379), clinical studies would have involved a gold standard for establishing ground truth, likely including culture, other cleared NAATs, and/or clinical diagnosis, but the details are not available in this summary.

    4. Adjudication Method for the Test Set

    This information is not explicitly provided for the studies in this summary.

    • For the Human Factors study, "difficulties were noted" and "packaged samples were then evaluated for errors according to the laboratory accessioning criteria." This suggests an objective assessment based on predefined criteria rather than a multi-expert adjudication of clinical diagnoses.
    • For the Interference study, it's a technical and controlled laboratory experiment, not requiring adjudication in the clinical sense.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size of Improvement with AI vs. without AI Assistance

    This is not applicable as the simpli-COLLECT STI Test is a molecular diagnostic test system for in vitro detection, not an AI-assisted diagnostic imaging or interpretation device. Therefore, no MRMC study or AI assistance effect size is mentioned or relevant.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) Was Done

    This is not applicable in the context of an "algorithm only" performance. The simpli-COLLECT STI Test is a collection and transport system intended to be used with the Alinity m STI Assay, which performs the actual detection. The Alinity m STI Assay operates automatically on the Alinity m System (an automated instrument), so its "standalone" performance would be its analytical and clinical performance as an automated assay, which was established in K202977 and K222379. The current submission focuses on the collection and transport component for home use.

    7. The Type of Ground Truth Used

    • Human Factors Study: Ground truth was based on pre-defined protocol steps for correct specimen collection and packaging, and laboratory accessioning criteria for evaluating collected samples.
    • Interference Study: Ground truth was established by preparing matrices with known positive (spiked with target organisms) or negative status, and then adding interfering substances at defined concentrations.
    • For the Alinity m STI Assay (from referenced K202977 and K222379): Likely clinical diagnosis, culture, and/or comparison to other legally marketed nucleic acid amplification tests (NAATs). The specific details are not in this summary.

    8. The Sample Size for the Training Set

    • Human Factors Study: 223 participants used as the test set. There isn't a separate "training set" mentioned for this usability evaluation. The design presumably refined the kit instructions prior to this summative study, but specific training set details are not provided.
    • Interference Study: No explicit "training set" concept applies here; it's a validation experiment.
    • For the Alinity m STI Assay (from referenced K202977 and K222379): Not detailed in this summary.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there's no explicitly defined "training set" for the type of studies presented here for the simpli-COLLECT STI Test. For the underlying Alinity m STI Assay, the ground truth for its training and validation would have been established through methods applicable to clinical diagnostic assays, as mentioned in point 7.

    Ask a Question

    Ask a specific question about this device

    K Number
    DEN200070

    Validate with FDA (Live)

    Device Name
    Simple 2 Test
    Date Cleared
    2023-11-15

    (1094 days)

    Product Code
    Regulation Number
    866.3385
    Type
    Direct
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Simple 2 Test is intended for in vitro detection and identification of Chlamydia trachomatis (CT) and/or Neisseria gonorrhoeae (GC) in home-collected specimens which are shipped to a clinical laboratory for testing using the Aptima Combo 2 Assay on the Panther System. This product is available over-the-counter (OTC) to consumers 18 years of age and older.

    The Simple 2 Test contains all the necessary components to collect urine from male patients (Simple 2 Urine Home Collection Kit (Penile)) or vaginal swabs from female patients (Simple 2 Swab Home Collection Kit (Vaginal)) in their home, or in similar environments, without supervision from a healthcare provider.

    The Simple 2 Test Collection Kits may also be used to self-collect specimens in a clinic.

    The testing is performed, as determined to be appropriate, based on the results of LetsGetChecked Suitability Questionnaire.

    This test system is not a substitute for visits to a healthcare provider. The information provided by this product should not be used to start, stop, or change any course of treatment unless advised by your healthcare provider.

    Testing is limited to the manufacturer, Priva Path laboratories (d.b.a. LetsGetChecked. Inc.).

    Device Description

    The LetsGetChecked Simple 2 Test is composed of the Simple 2 Urine Home Collection Kit (Penile) and the Simple 2 Swab Home Collection Kit (Vaginal) and the samples are shipped to LetsGetChecked's Clinical Laboratory Improvement Amendments (CLIA)-certified laboratory for processing using the Aptima Combo 2 Assay on the Panther System. The Aptima Combo 2 Assay was previously cleared for the qualitative in vitro detection of Chlamydia trachomatis (CT) and/or Neisseria gonorrhoeae (GC) when used with male urine and self-collected vaginal swabs collected in clinical settings.

    The home collection kits are intended to be distributed for purchase online without the need for prescription from a physician or healthcare professional (over-the-counter use). After purchase, the user activates the kit on LetsGetChecked's website and is requested to fill out the Suitability Questionnaire to determine whether this test is appropriate for this individual. The user follows detailed directions for self-collecting a urogenital specimen (male urine or female vaginal swab, as applicable), packaging and shipping it to the LetsGetChecked CLIA certified laboratory for testing (PrivaPath lab). The test results are delivered to the individual via LetsGetChecked online portal. Positive and invalid/inconclusive results are followed up with a call from the LetsGetChecked Care Team. If the patient received a positive chlamydia result, treatment options are discussed. Patients receiving a positive gonorrhea test result, will be advised to contact their healthcare provider to receive appropriate treatment. The LetsGetChecked Care Team will also contact all patients who test negative for chlamydia and gonorrhea, but do report symptoms, or concerns, or where further investigation is indicated. These patients are internally flagged for follow-up.

    AI/ML Overview

    The provided text describes the evaluation of the Simple 2 Test, a device for the in vitro detection and identification of Chlamydia trachomatis (CT) and/or Neisseria gonorrhoeae (GC) in home-collected specimens. The device is intended for over-the-counter use by consumers 18 years of age and older.

    The acceptance criteria for the device are focused on usability and comprehension by lay users and the analytical performance of the collection kits under various challenging conditions (flex studies, interfering substances, shipping stability), ensuring that the home collection process does not compromise the accuracy of the downstream testing performed by the Aptima Combo 2 Assay on the Panther System.

    Here's a breakdown of the requested information based on the provided document:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a single table outlining predefined "acceptance criteria" alongside specific performance metrics the device must meet. Instead, it describes various studies and their outcomes, implicitly demonstrating the device's acceptable performance. The "Success Rate" shown in Tables 3, 4, 7, and 8 for usability/comprehension, and the "Agreement with expected result" in Tables 9, 10, 11, 12, 13, 14, 16, 18, 19, and 20 for analytical performance, serve as the evidence of meeting the unstated acceptance goals.

    Based on the summaries of the studies, the implicit acceptance criterion for usability and comprehension appears to be a high success rate (generally aiming for 100% in critical steps or demonstrating that modifications resolve issues) for proper specimen collection, packaging, and comprehension of instructions and results. For analytical performance, the criterion is largely 100% agreement with expected results under various challenging conditions, or demonstration that the test robustly performs within acceptable limits despite certain challenging conditions, with any identified limitations clearly called out in labeling.

    Implicit Acceptance Criteria and Reported Performance (Selected examples from the document):

    CategoryStudy/ParameterImplicit Acceptance Criteria (Goal)Reported Device Performance (Key Findings)
    Usability & Comprehension (Male Urine Kit)Ability to transfer correct urine volume (after modification)High success rate"The results from this study showed that 9% (8/89) of lay users had difficulty transferring correct volume of urine... Therefore, modifications to the home collection kit and instructions were necessary..." (Initial study). Modifications made: graduated transfer pipette and revised instructions. The second study's "Success Rate" for various steps indicates high user compliance, though exact percentage for volume transfer is redacted in Table 3. The text states: "replacing generic transfer pipette with the graduated transfer pipette allows the users to transfer an appropriate amount of urine..."
    Comprehension of IFU, warnings, and general infoHigh success rateData redacted in Table 3, but the text states: "...results from the questionnaire support the conclusion that lay users demonstrated comprehension of the critical elements in the labeling..."
    Usability & Comprehension (Female Vaginal Swab Kit)Ease of use of collection kitHigh success rateInitial study led to modifications for closer alignment with Hologic's instructions and FAQs. Success rates for various steps are redacted in Table 7, but the text states: "...results from the questionnaire support the conclusion that lay users demonstrated comprehension of the critical elements in the labeling..."
    Flex Studies (Urine Kit - Underfilled Tubes)CT/GC detection at LoD with varying urine volumes100% agreement with expected results (or robust performance within acceptable limits)CT: 100% agreement when at least [b-4] of urine transferred; 80% at lower volumes. GC: 100% agreement when at least [b-4] of urine transferred; 60% at lower volumes. The conclusion states: "...underfilling the Transport Tube with urine will generate accurate results if at least [b-4] of the specified volume) of urine is transferred."
    Flex Studies (Urine Kit - Overfilled Tubes)CT/GC detection at LoD with varying urine volumes100% agreement with expected resultsCT/GC: 100% agreement across all tested overfilled volumes (Table 10). The conclusion states: "The results also showed that the test is not sensitive to overfilling the Transport Tube."
    Flex Studies (Urine Kit - Delay of Urine Transfer)CT/GC detection at LoD with delay in transfer100% agreement until specified delay limitCT: 100% agreement up to 6 days, then drops to 60% at Week 3. GC: 100% agreement up to 1 day, then drops to 0% at 2 days. The conclusion states: "False negative results for CT were obtained when the urine was transferred... three weeks... False negative results were obtained for GC when the transfer of urine... was delayed more than one day." Mitigation: IFU directs immediate transfer and same-day shipping.
    Interfering Substances (Urine Kit)CT/GC detection at LoD in presence of contaminants100% agreement with expected resultsCT: 100% agreement with all substances. GC: False negatives obtained with certain brands of hand soap (0% and 67%) and hand sanitizer (50%). Mitigation: Labeling cautions and instructions to wash/dry hands.
    Interfering Substances (Vaginal Swab Kit)CT/GC detection at LoD in presence of contaminants100% agreement with expected resultsCT/GC: 100% agreement with all substances (Table 14).
    Shipping Stability (Urine Kit - Summer/Winter)CT/GC detection at LoD after exposure to extreme temperaturesMaintain sample integrity allowing for expected results (>95% positivity at LoD)Summer: 100% positive for both CT/GC. Winter: [b-4] positive for CT, [b-4] positive for GC. The conclusion states: "The data demonstrate that the urine sample integrity is maintained even when exposed to extremes of temperature during shipping." Acceptable as >95% positive at LoD when a certain (redacted) number of samples were tested.
    Shipping Stability (Vaginal Swab Kit - Summer/Winter)CT/GC detection at LoD after exposure to extreme temperaturesMaintain sample integrity allowing for expected resultsSummer/Winter: 100% positive for both CT/GC. The conclusion states: "The study results demonstrate that the vaginal swab sample integrity is maintained even when exposed to extremes of temperature during shipping."

    2. Sample Size Used for the Test Set and Data Provenance

    The test sets are primarily derived from usability and analytical performance studies.

    • Usability Studies (Test Set):

      • Simple 2 Urine Home Collection Kit (Penile):
        • Initial study: 89 male participants.
        • Final usability study: 32 male participants.
      • Simple 2 Swab Home Collection Kit (Vaginal):
        • Initial study: 85 female participants.
        • Final usability study: 34 participants (33 female, 1 transgender male).
      • Data Provenance: The studies were conducted remotely from lay users' homes via online video conferencing. No specific country of origin is mentioned beyond being a US FDA submission, implying the studies were conducted in the US or for the US market. The studies appear to be prospective in nature, as they involve participants actively performing tasks following instructions and providing feedback/data.
    • Analytical Performance Studies (Flex, Interfering Substances, Shipping Stability - Test Set):

      • These studies involved specific numbers of replicates for each condition (e.g., [b-4] positive and [b-4] negative replicates for flex studies on urine volume). The exact total sample sizes for these analytical tests are scattered across tables with redacted information (e.g., "[b-4] positives/[b-4] tested").
      • Data Provenance: These are laboratory-based analytical studies, not human clinical trials. The data provenance is internal to the manufacturer's testing or a clinical laboratory. No specific country of origin is stated, but given the FDA submission, the data is expected to be relevant to US regulatory standards. These are experimental evaluations, likely prospective in nature within a controlled lab setting, designed to mimic real-world conditions.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Usability Studies: Ground truth for these studies was generally based on the objective observation of successful completion of tasks (e.g., transferring correct urine volume, proper packaging) and comprehension of instructions/information as assessed by study staff questions. The document does not specify the number or qualifications of experts involved in observing or assessing these lay user interactions directly. However, the design of the modifications and the evaluation criteria would have been informed by regulatory requirements and potentially human factors experts.
    • Analytical Performance Studies: For these studies, the ground truth is the expected presence or absence of CT/GC in the spiked or unspiked samples. This is a scientific, laboratory-defined ground truth, established by the precise spiking of organisms at known concentrations into negative matrices or using truly negative samples. The "experts" in this context are the laboratory scientists and technicians conducting the assays and preparing the samples, presumed to be qualified in molecular diagnostics. No specific number or external qualifications are mentioned for establishing this analytical ground truth, as it's inherent to the experimental design (e.g., "spiked with CT or GC organisms at the target concentration of LoD").

    4. Adjudication Method for the Test Set

    • Usability Studies: The success/failure of user actions and comprehension was likely determined by the study staff observing and questioning participants. The document doesn't detail a formal "adjudication" process akin to expert reader consensus, but rather a direct assessment of task completion and questionnaire responses. Issues identified (e.g., difficulty transferring urine) led to design modifications, implying an iterative evaluation process rather than a strict adjudication of initial failures.
    • Analytical Performance Studies: The results (e.g., #positives/#tested, agreement with expected result) are quantitative outcomes of the biochemical assay. There is no mention of an "adjudication method" in the sense of multiple human experts reviewing results. The expectation is that the laboratory results directly represent the device's performance under the tested conditions.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    There is no mention (and no indication) of a Multi-Reader Multi-Case (MRMC) comparative effectiveness study involving human readers with and without AI assistance. This device is not an AI-assisted diagnostic. It is a home collection kit for a laboratory test, wherein the "device" is the collection system and the final analysis is done by an established IVD system (Aptima Combo 2 Assay on the Panther System). The studies focus on the usability and analytical integrity of the home-collected samples, not on AI-assisted interpretation of diagnostic images or data.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    This question is Not Applicable in the context of this device. The Simple 2 Test is a collection kit, not a standalone algorithm. The "algorithm" (nucleic acid amplification assay) is the Aptima Combo 2 Assay on the Panther System, which is a pre-existing cleared/approved device. The performance data presented relates to the integrity and suitability of the home-collected samples for use with that established assay, not a novel standalone algorithm.

    7. Type of Ground Truth Used

    • Usability Studies: The ground truth for these studies was the observed proper execution of instructed tasks and comprehension of information by lay users, assessed against predefined criteria for successful use of the collection kit and understanding of the accompanying materials.
    • Analytical Performance Studies: The ground truth was analytically established through precise spiking of known concentrations of CT and GC organisms into negative matrices, or the use of confirmed negative samples. This constitutes a laboratory-defined ground truth (e.g., "spiked with GC or CT at 3x LoD").

    8. Sample Size for the Training Set

    The document describes two phases of usability/comprehension studies (initial and final) for both the urine and vaginal swab kits. The initial studies for both kits served a similar function to a training set or preliminary evaluation, leading to modifications in the kit and instructions.

    • Simple 2 Urine Home Collection Kit (Penile): 89 male participants in the initial study.
    • Simple 2 Swab Home Collection Kit (Vaginal): 85 female participants in the initial study.
      These initial studies acted as "training" or optimization phases by identifying deficiencies that informed product improvements.

    For the analytical "flex studies, interfering substances, and shipping stability" tests, the concept of a "training set" is not applicable in the typical machine learning sense. These are experimental validations. The initial LoD (Limit of Detection) establishment, mentioned briefly, might involve some preliminary testing that could be seen as "training" for setting analytical parameters, but no specific sample size for such an activity is provided.

    9. How the Ground Truth for the Training Set Was Established

    For the usability studies, the ground truth for the initial "training" phase was based on direct observation of user performance and comprehension assessments, identifying areas where users struggled or misunderstood. For example, the 9% of users having difficulty transferring urine volume in the initial penile kit usability study highlighted a deficiency that needed to be addressed. This identified "ground truth" (i.e., areas of user error) then informed the modifications.

    For the analytical studies, as noted in point 7, ground truth is laboratory-defined by precise manipulation of samples (e.g., spiking with known concentrations, ensuring negative samples are truly negative). This analytical ground truth would be established through standard laboratory and molecular biology techniques.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1