Search Filters

Search Results

Found 91 results

510(k) Data Aggregation

    K Number
    K254208

    Validate with FDA (Live)

    Date Cleared
    2026-03-20

    (81 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K253925

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-01-15

    (38 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Aventus Thrombectomy System is indicated for:

    • The non-surgical removal of emboli and thrombi from blood vessels.
    • Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel.

    The Aventus Thrombectomy System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism.

    Device Description

    The Aventus Thrombectomy System is a catheter-based manual aspiration system designed for minimally invasive removal of emboli and thrombi from pulmonary arteries, the peripheral vasculature and/or infusing fluids. The System is comprised of the following major components:

    • Aventus Thrombectomy Catheter
    • Clot Management System consisting of:
      • Aspiration Syringe
      • Clot Canister

    The System is compatible with a standard 24-French (24F) introducer sheath, Navigation Catheters and is to be used with 0.035" guidewires. The System is provided sterile and is intended for single use only.

    The Aventus Thrombectomy Catheter includes an atraumatic radiopaque Distal Tip with embedded sensors, and an angled aspiration orifice for directional aspiration and navigation without a dilator. The Catheter Handle assists the clinician in navigating within the vasculature and includes a Sensing Indicator and houses the Sensing electronics.

    The Aspiration Catheter shaft incorporates a metallic reinforcement layer made of stainless steel, an inner liner and polymeric outer jacket having variable stiffness, and includes a hydrophilic coating applied to the outside of the catheter shaft.

    The System is provided with a 60-cc dual action manual syringe which allows for directional flow control and directs aspirated blood and clot into the Clot Canister.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252509

    Validate with FDA (Live)

    Date Cleared
    2025-11-24

    (108 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cannula is indicated for:

    • the non-surgical removal of thrombi or emboli from the vasculature
    • aspiration and injection of contrast media and other fluids from and into the vasculature

    The Cannula is intended for use in the venous system and for the treatment of pulmonary embolism.

    The Handle is indicated as a vacuum source for the AlphaVac Multipurpose Mechanical Aspiration System.

    The Sheath is intended to be inserted in the vasculature to provide a conduit for the insertion of the AlphaVac Cannula/Obturator and other endovascular devices while minimizing blood loss associated with such insertions.

    Device Description

    The AlphaVac Multipurpose Mechanical Aspiration (MMA) System is a single use-over-wire catheter-based system that facilitates the removal of thrombus, embolus, or clot during minimally invasive percutaneous procedures. The AlphaVac MMA Systems are comprised of six main components packaged together:

    • a flexible AlphaVac Cannula with self-expandable, nitinol reinforced, angled funnel shaped distal tip
    • AlphaVac Sheath
    • AlphaVac Obturator
    • AlphaVac Handle
    • Collection Bags
    • AlphaVac Tubing

    The AlphaVac Cannula is placed within target vasculature using standard percutaneous vascular access techniques (i.e., Seldinger) and commonly available vascular access tools (e.g., guidewire, vascular introducers, etc.). Once the cannula is in place, the AlphaVac Handle and waste bag are connected and primed. The AlphaVac Cannula is advanced out of the sheath and the nitinol basket automatically expands into a funnel, aiding in the removal of thrombus, emboli, and clot. The aspiration handle is pulled back creating suction and pulling the material into the catheter, removing it from the vasculature. The aspirated material is captured and contained within the waste bag for disposal. Target vessels include, but are not limited to, the iliofemoral vein, Inferior Vena Cava (IVC), Superior Vena Cava (SVC), Right Heart (Atrium (RA)), and Pulmonary Artery Vasculature. The device is provided in ~85° angled configuration.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251312

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-10-24

    (179 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vesalio Peripheral Catheter is intended for use in the peripheral arterial vasculature for:

    • the removal of fresh, soft emboli and thrombi
    • infusion of diagnostic agents, such as contrast media
    Device Description

    The Vesalio Peripheral System consists of 1) Peripheral Catheter, 2) Peel away Introducer Sheath and 3) an Aspiration Tubing Set.

    The Peripheral Catheter is a single-lumen, coil-reinforced, flexible, variable stiffness composite catheter that facilitates the removal of thrombus from the peripheral arterial vasculature when connected to a compatible aspiration pump and the Aspiration Tubing Set.

    The catheter is a hollow cylindrical tube constructed using a combination of medical-grade polymers with metal reinforcement, a lubricous inner liner made from PTFE and the outer jacket consisting of thermoplastics made of polyurethane, polyether block amide, and nylon 12. The distal end of the catheter has a hydrophilic coating aimed to reduce friction and aid tracking through the vasculature. The catheter employs radiopaque characteristics for angiographic visualization.

    On the proximal end, the catheter incorporates a flexible strain relief, which provides kink resistance, and a translucent, polycarbonate female luer hub to allow attachment of ancillary devices for navigation, infusion of fluids, and aspiration through the catheter.

    A peel-away introducer sheath is provided in the package to facilitate the insertion of the Peripheral Catheter's distal tip into an appropriate vascular sheath.

    The Aspiration Tubing Set is provided in a separate package and is made of common medical grade polymers. It comprises of a hollow cylindrical tube that is bonded to a standard male rotator fitting on one end. The male rotator allows the tubing to connect to an RHV or the female luer hub of the catheter. The other end of the tubing consists of a hose fitting to enable connection with a vacuum pump. A flow switch is connected in line to provide vacuum control. The Peripheral System is provided sterile, non-pyrogenic, and is intended for single use only.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251488

    Validate with FDA (Live)

    Date Cleared
    2025-07-14

    (61 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Expanse FLOWRUNNER Aspiration System is indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems.

    Device Description

    The Expanse FLOWRUNNER Aspiration System is a peripheral thrombectomy system consisting of several components:

    • FLOWRUNNER Aspiration Catheter
    • FLOWRUNNER Aspiration Sheath
    • Vacuum Fitting
    • High Flow Stopcock Connector
    • Y-Connector with Hemostatic Valve
    • Hand Actuator Clip

    The FLOWRUNNER Aspiration System is designed for the minimally invasive removal of thrombus from the peripheral vasculature using aspiration. The system has demonstrated compatibility with standard vascular implants, including stents and filters. It is a single use, over-the-wire, catheter-based system with the ability to infuse fluid. The FLOWRUNNER Aspiration System consists of one aspiration catheter, one aspiration sheath, one vacuum fitting, one high flow stopcock connector, one Y-connector with hemostatic valve, and a hand actuator clip.

    The FLOWRUNNER Aspiration System is introduced to the site of the primary occlusion. The Aspiration Catheter is advanced through the Aspiration Sheath and targets aspiration directly to the thrombus. The Aspiration Catheter is then retracted back into the Aspiration Sheath. This process of extension and retraction of the Aspiration Catheter is then repeated to fully aspirate the clot. Suction is applied directly to the Aspiration Catheter from an external vacuum source to aspirate thrombus from an occluded vessel (maximum pressure -27.6 in Hg and minimum pressure of -8.0 in Hg).

    Sterile saline flows through the Aspiration Sheath and into the Aspiration Catheter when connected proximally. No saline is injected into the patient during aspiration. The Aspiration Catheter and Sheath are visible under fluoroscopy. The hand actuator is an optional, proximal clip attached to the Aspiration Catheter to assist the user.

    The FLOWRUNNER Aspiration System comes in 12F, 14F compatible diameters and 60cm, 80cm, 100cm and 120cm lengths.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for the FLOWRUNNER Aspiration System are for a medical device (an embolectomy catheter), not an AI/ML powered device. As such, the document does not contain information typically found in submissions for AI/ML devices regarding acceptance criteria, study design for AI performance, ground truth, or expert involvement in classification.

    The information provided focuses on the FLOWRUNNER Aspiration System's equivalence to a predicate device (ICE Aspiration System) for its intended use in removing emboli and thrombi from peripheral vessels. The "performance data" section refers to bench testing, which is standard for hardware medical devices, not AI/ML performance metrics.

    Therefore, I cannot extract the requested information about acceptance criteria, study details, human reader improvement with AI, standalone performance, ground truth establishment, or training set size. This document does not describe a study involving AI/ML.

    Here's a summary of what information can be extracted from the document, related to its non-AI performance claims:

    1. A table of acceptance criteria and the reported device performance:

    The document summarizes the performance testing generically as "Bench testing was performed to support a determination of substantial equivalence to the predicate." It lists the types of bench tests conducted but does not provide specific acceptance criteria values or detailed reported performance results against those criteria.

    Acceptance Criteria (Implied)Reported Device Performance
    In-Stent and IVC Filter compatibility"demonstrated compatibility with standard vascular implants, including stents and filters"
    Thrombus CapturePerformed (specific results not detailed)
    Conformance to intended use requirements"designed and tested to assure conformance to the requirements for its intended use"
    Reliability (general)"Performance testing demonstrated that the FLOWRUNNER Aspiration System reliably raises no new questions of safety and effectiveness."

    2. Sample size used for the test set and the data provenance:

    Not applicable, as this refers to bench testing on physical components, not a clinical test set with patient data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications:

    Not applicable. Ground truth for clinical data is irrelevant to bench testing of a hardware device.

    4. Adjudication method for the test set:

    Not applicable.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    No. This device is not AI-powered, so no such study was conducted or is relevant.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done:

    No. This device is not an algorithm. Bench testing evaluates the physical device's performance.

    7. The type of ground truth used:

    Not applicable in the context of AI/ML. For the bench testing, the "ground truth" would be engineering specifications and validated test methods to assess the physical device's capabilities (e.g., ability to capture thrombus in a model, compatibility with stents).

    8. The sample size for the training set:

    Not applicable. This is not an AI/ML device.

    9. How the ground truth for the training set was established:

    Not applicable. This is not an AI/ML device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243549

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-04-04

    (140 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The JETi™ Hydrodynamic Thrombectomy System is intended to remove/aspirate fluid and break-up soft emboli and thrombus from the peripheral vasculature, including deep vein thrombosis (DVT), and to sub-selectively infuse/deliver diagnostics or therapeutics with or without vessel occlusion.

    Device Description

    The JETi™ Hydrodynamic Thrombectomy System (JETi HTS) is a hydro-mechanical aspiration system intended for the removal of intravascular thrombus. The system is comprised of the JETi™ Catheter, JETi™ Pump Set, JETi™ Saline Drive Unit (SDU), JETi™ Accessory Cart, JETi™ Suction Tubing, and JETi™ Non-sterile Canister Set. The JETi Hydrodynamic Thrombectomy System is designed to continuously aspirate thrombotic material into the JETi Catheter, where a high-pressure stream of saline within the catheter tip macerates the thrombus as it is aspirated.

    AI/ML Overview

    Here's an analysis of the provided text, focusing on acceptance criteria and the supporting study, structured as requested:

    1. Table of Acceptance Criteria and Reported Device Performance

    Criterion TypeAcceptance CriteriaReported Device Performance
    Primary EffectivenessAt least 75% reduction in modified Marder Score from pre-JETi venogram to final venogram (per core laboratory assessment), with a one-sided 97.5% lower confidence limit comparing to a performance goal of 64%.Achieved in 84.5% (93/110) limbs, with a one-sided 97.5% lower confidence limit of 76.4%, which compares favorably to the performance goal of 64% (p value < 0.0001). The primary effectiveness endpoint was met.
    Primary SafetyComposite of JETi-related major adverse events up to 30 days post-JETi (per CEC adjudication) should be less than 10%.1.7% (2/116) (95% CI, 0.21%, 6.09%). This rate is less than the acceptance criterion of 10%. The primary safety endpoint was met.
    Secondary Outcomes (Implied)Improved treated vessel patency and compressibility, Villalta post-thrombotic syndrome score, leg pain, and quality of life at 30 days. (While not explicitly stated as "acceptance criteria," these are reported as positive outcomes that support the device's effectiveness.)All were improved at 30 days.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size (Clinical Testing - JETi Registry):
      • Total registered subjects in the registry: 260
      • Subjects treated for lower extremity (LE) DVT (analysis population for effectiveness and safety): 116
      • Limbs evaluated for the primary effectiveness endpoint: 110
      • Subjects evaluated for the primary safety endpoint: 116
    • Data Provenance: Prospective, multi-center study conducted in the United States (US) and Europe.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    • The document mentions "core laboratory assessment" for the primary effectiveness endpoint (Marder Score reduction) and "CEC adjudication" (Clinical Events Committee adjudication) for the primary safety endpoint (major adverse events).
    • The number and specific qualifications of the experts within the core laboratory and CEC are not specified in the provided text.

    4. Adjudication Method for the Test Set

    • Effectiveness Endpoint: "core laboratory assessment"
    • Safety Endpoint: "CEC adjudication"
    • The specific adjudication method (e.g., 2+1, 3+1, none) used by the core laboratory or CEC is not detailed in the provided text.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size

    • No, an MRMC comparative effectiveness study was NOT done. The clinical study described (JETi Registry) is a "prospective, single-arm, multicenter study" focused on the performance of the JETi HTS alone. It does not compare the device's performance with and without AI assistance or against human readers.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    • The JETi™ Hydrodynamic Thrombectomy System is a physical medical device (a thrombectomy system). It does not appear to be an AI/algorithm-based device, so the concept of "standalone algorithm performance" is not applicable here. The study assesses the performance of the device in treating thrombosis.

    7. The Type of Ground Truth Used

    • Effectiveness Endpoint: Modified Marder Score from pre-JETi venogram to final venogram, assessed by a core laboratory. This suggests a standardized, expert-driven assessment of imaging data.
    • Safety Endpoint: JETi-related major adverse events, adjudicated by a Clinical Events Committee (CEC). This indicates expert consensus based on clinical event reporting.

    8. The Sample Size for the Training Set

    • Not applicable. The provided document describes a clinical study for a physical medical device (JETi™ Hydrodynamic Thrombectomy System), not an AI algorithm. Therefore, there is no "training set" in the context of machine learning.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable. As mentioned above, this is a physical medical device, not an AI algorithm.
    Ask a Question

    Ask a specific question about this device

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The VentiV 7Fr – 12Fr MP Mechanical Thrombectomy System and VentiV Mechanical Aspirator are indicated for the removal of fresh soft emboli and thrombi from vessels in the peripheral vasculature.

    Device Description

    The VentiV Mechanical Thrombectomy System devices are single-use, sterile, short-term use medical devices designed to remove fresh soft emboli, debris, and thrombi from the peripheral vasculature. The System includes (1) VentiV Mechanical Aspirator and (1) VentiV 7Fr - 12Fr catheters and dilators.

    AI/ML Overview

    Based on the provided text, the device in question is the VentiV 7Fr - 12Fr MP Mechanical Thrombectomy System. This is a medical device, not an AI/ML powered device, therefore no acceptance criteria related to AI/ML device performance (like sensitivity, specificity, AUC, human reader studies etc.) are mentioned.

    The information provided describes the regulatory submission for premarket notification (510(k)) of a medical device, asserting its substantial equivalence to a legally marketed predicate device. The document details the physical and functional characteristics of the device and how they compare to the predicate, as well as the non-clinical testing performed.

    Therefore, the specific information requested in the prompt about acceptance criteria and study proving AI/ML device performance (e.g., acceptance criteria for AI performance metrics, sample size for test sets, expert adjudication, MRMC studies, standalone AI performance, ground truth establishment for AI models, training set details) is not applicable to this document as it pertains to a mechanical medical device, not an AI/ML powered one.

    However, I can extract the general acceptance criteria and the type of study performed to prove this mechanical device meets its intended use, based on the non-clinical testing conducted.


    Acceptance Criteria and Study for the VentiV 7Fr - 12Fr MP Mechanical Thrombectomy System

    Given that the device is a mechanical thrombectomy system and not an AI/ML powered device, the "acceptance criteria" discussed in this document relate to the performance and safety of the physical device compared to its predicate, rather than AI-specific metrics. The "study" refers to non-clinical bench testing.

    1. Table of Acceptance Criteria (Implied) and Reported Device Performance (Non-Clinical)

    While an explicit, quantifiable table of acceptance criteria for performance metrics is not provided in a format typical for AI/ML devices, the document states that all necessary verification steps met "pre-determined acceptance criteria" to demonstrate substantial equivalence. The reported performance refers to the device passing simulated use tests.

    Acceptance Criteria (Implied through Substantial Equivalence and Testing)Reported Device Performance (Non-Clinical Testing)
    Intended Use Equivalence: Comparable to predicate in removing fresh soft emboli and thrombi from peripheral vasculature.Same intended use as the predicate.Same indications for use as the predicate.
    Fundamental Scientific Technology Equivalence: Operates on the same principle as the predicate.Same fundamental scientific technology (over-the-wire intravascular catheters, aspiration for thrombectomy).Same operating principle (manual syringe action to create vacuum).
    Material Properties Equivalence: Materials are comparable to the predicate for safe and effective use.Same material properties as the predicate.
    Performance Specifications Equivalence: Meets similar functional specifications as the predicate.Same performance specifications as the predicate.Same maximum vacuum potential (-760mmHg, -1ATM, -14.69PSI).
    Physical Design Equivalence: Catheter dimensions, tip shape, aspiration lumen, guidewire compatibility are within comparable ranges to the predicate.Catheter Shaft OD: Added 12Fr (predicate 7-11Fr). Otherwise, 7Fr-11Fr are same.Usable Lengths: Range expanded to 60-100cm (predicate 60-90cm).Tip Shape: Multipurpose (predicate Straight).Aspiration Lumen Shape: Round (Same).Guidewire: 0.035" (Same).Integrated Radiopaque Marker: Yes (Same).
    Sterilization and Packaging Equivalence: Uses similar methods for sterilization and packaging.Sterilization: ETO (Same).Packaging: Catheter in Hoop and Tyvek Tray (Same).
    Biocompatibility: Meets established biocompatibility standards.Biocompatibility: ISO 10993 compliant (Same).
    Simulated Use Performance: Successfully tracks, aspirates in simulated peripheral vasculature.Device "passes simulated use tracking, simulated aspiration, and simulated thrombectomy in the peripheral vasculature."
    Accelerated Aging Performance: Performs as intended after accelerated aging.Device "passes..." tests with accelerated aging up to 3-years.

    2. Sample Size Used for the Test Set and Data Provenance:

    • Sample Size for Test Set: The document mentions "non-clinical testing" and refers to "test units" without specifying precise numerical sample sizes. This typically refers to a number of physical device units tested in a lab setting.
    • Data Provenance: The data is generated from non-clinical bench testing rather than patient data. Therefore, concepts like "country of origin of the data," "retrospective," or "prospective" are not applicable. It's laboratory-generated data.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications:

    • Not Applicable. As this is a mechanical device, there is no "ground truth" established by experts in the context of image interpretation or clinical diagnosis. The "ground truth" for performance is based on direct physical measurements, simulations, and engineering specifications.

    4. Adjudication Method for the Test Set:

    • Not Applicable. There is no "adjudication" in the sense of reconciling expert opinions for a test set, as this is bench testing of a physical device. Performance is objectively measured against specifications.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    • No. An MRMC study is not mentioned because this is a mechanical device, not an AI/ML diagnostic system intended to assist human readers with interpretation.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study:

    • Not Applicable. This is a mechanical medical device, not an algorithm, so independent algorithmic performance is not relevant.

    7. The Type of Ground Truth Used:

    • For this mechanical device, the "ground truth" for performance and substantial equivalence is established through:
      • Bench Testing: Direct physical measurements, engineered simulations (e.g., simulated vessels, simulated thrombi), and performance against predefined engineering specifications.
      • Regulatory Standards: Compliance with relevant international standards (e.g., ISO 10993 for biocompatibility) and FDA guidance for medical device testing.
      • Predicate Device Performance: The predicate device itself serves as a "ground truth" benchmark for demonstrating substantial equivalence in function and safety.

    8. The Sample Size for the Training Set:

    • Not Applicable. This is not an AI/ML device that requires a "training set" of data.

    9. How the Ground Truth for the Training Set Was Established:

    • Not Applicable. As there is no training set for an AI/ML model, the concept of establishing ground truth for it does not apply.
    Ask a Question

    Ask a specific question about this device

    K Number
    K240397

    Validate with FDA (Live)

    Date Cleared
    2024-04-01

    (52 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cannula is indicated for:
    · the non-surgical removal of thrombi or emboli from the vasculature
    · aspiration of contrast media and other fluids from the vasculature

    The Cannula is intended for use in the venous system and for the treatment of pulmonary embolism.

    The Handle is indicated as a vacuum source for the AlphaVac Multipurpose Mechanical Aspiration System.

    Device Description

    The AlphaVac Multipurpose Mechanical Aspiration (MMA) F1885 System is a single use-overwire catheter-based system that facilitates the removal of thrombus, embolus, or clot during minimally invasive percutaneous procedures. The AlphaVac MMA F186 System is comprised of six main components packaged together:

    • . a flexible AlphaVac Cannula with self-expandable, nitinol reinforced, angled funnel shaped distal tip (18F)
    • AlphaVac Sheath (22F)
    • AlphaVac Obturator (17F) ●
    • AlphaVac Handle .
    • . Waste Bag and Tubing

    The AlphaVac Cannula is placed within target vasculature using standard percutaneous vascular access techniques (i.e., Seldinger) and commonly available vascular access tools (e.g., guidewire, vascular introducers, etc.). Once the cannula is in place, the AlphaVac Handle and waste bag is connected and primed. The AlphaVac Cannula is advanced out of the sheath and the nitinol basket automatically expands into a funnel, aiding in the removal of thrombus, emboli, and clot. The aspiration handle is pulled back creating suction and pulling the material into the catheter, removing it from the vasculature. The aspirated material is captured and contained within the waste bag for disposal. Target vessels include, but are not limited to, the iliofemoral vein, Inferior Vena Cava (IVC), Superior Vena Cava (SVC), Right Heart (Atrium (RA)), and Pulmonary Artery Vasculature. The device is provided in ~85° (AlphaVac F1885) angled configuration.

    AI/ML Overview

    The provided text describes the 510(k) summary for the AngioDynamics AlphaVac Multipurpose Mechanical Aspiration (MMA) F1885 System. While it details the device and its intended use, it does not explicitly provide information on acceptance criteria for an AI/ML-based medical device, nor does it present a study proving the device meets AI/ML specific acceptance criteria. This document describes a traditional medical device (a catheter system) and its performance through bench testing and a clinical trial.

    Therefore, I cannot extract the requested information about AI/ML acceptance criteria and a study proving the device meets them from the provided text.

    Here's why and what information is available:

    • Device Type: The AlphaVac MMA F1885 System is described as a "single use-overwire catheter-based system that facilitates the removal of thrombus, embolus, or clot." This is a physical, mechanical medical device, not an AI/ML software device.
    • Performance Data (K): This section refers to "Comprehensive bench testing (integrity and functional performance)" and lists various engineering and mechanical tests (Dimensional Testing, Tensile Testing, Fluid Volume Removal, etc.). These are typical tests for a physical medical device.
    • Clinical Testing (L): This section describes the APEX-AV trial, a multicenter pivotal study to assess the use of the device in subjects with acute intermediate-risk pulmonary embolism. The primary safety endpoint was the rate of major adverse events (MAEs), and the primary effectiveness endpoint was the reduction in RV/LV ratio. These are standard clinical trial endpoints for a physical medical device.

    To answer your request, if this were an AI/ML device, the information would typically include:

    1. AI/ML Specific Acceptance Criteria: Metrics like sensitivity, specificity, AUC, F1 score, precision, recall, positive predictive value (PPV), negative predictive value (NPV), often with specific thresholds (e.g., "Sensitivity must be >= 90%").
    2. Study Design for AI/ML Evaluation:
      • Test Set Details: Sample size, data provenance (e.g., patient demographics, imaging modalities, data type like CT scans, X-rays), and whether it was retrospective or prospective.
      • Ground Truth Establishment: Number and qualifications of experts, the adjudication method (e.g., 2+1, 3+1 for consensus), and the nature of the ground truth (e.g., expert consensus, pathology, clinical outcomes).
      • MRMC Study: Whether a multi-reader multi-case study was performed, and its findings on human reader improvement with AI assistance.
      • Standalone Performance: Specific metrics for the algorithm-only performance.
      • Training Set Details: Sample size and how ground truth was established for the training data.

    Since this document pertains to a mechanical medical device, none of the above AI/ML specific details are present.

    Ask a Question

    Ask a specific question about this device

    K Number
    K232458

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-12-19

    (126 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The JETiTM Hydrodynamic Thrombectomy System is intended to remove/aspirate fluid and thrombus from the peripheral vasculature and to sub-selectively infuse/deliver diagnostics with or without vessel occlusion.

    Device Description

    The JETiTM Hydrodynamic Thrombectomy System is a hydro-mechanical aspiration system intended for the removal of intravascular thrombus. The system is comprised of the JETiTM Catheter, JETiTM Pump Set, JETiTM Saline Drive Unit (SDU), JETiTM Accessory Cart, JETiTM Suction Tubing, and JETiTM Non-sterile Canister Set. The JETi Hydrodynamic Thrombectomy System is designed to continuously aspirate thrombotic material into the JETi Catheter, where a high-pressure stream of saline within the catheter tip macerates the thrombus as it is aspirated.

    The JETi Catheter has two (2) lumens. The primary lumen (largest) is a conduit for thrombus aspiration. A secondary lumen, placed within the primary lumen, delivers saline through an orifice to break up and dilute the aspirated thrombus and facilitates rapid movement of the aspirate towards the vacuum. One (1) radiopaque (RO) marker band is located stiff proximal section which transitions to a more flexible distal section with a round, soft tip. A filter is incorporated into the catheter connector to ensure that no debris or foreign material is injected into the patient vasculature. The JETi Catheter is available in two sizes: 6 French size (6F) and 8 French size (8F). The JETi Pump Set is intended to deliver a high pressure sterile saline stream to the JETi Catheter. The pressure for the saline stream is created through the cassette's piston assembly, which snaps into the SDU.

    The JETi Saline Drive Unit (SDU) is a non-sterile reusable, (multiple patient, multiple use) device that incorporates the saline pumping components and the vacuum pump within a single enclosure. The fork drive of the SDU is designed to run the JETi Pump Set piston assembly to deliver a stream of saline to the JETi Catheter when activated by the handheld switch if the vacuum is present. In conjunction with the JETi Pump Set, the SDU can sub selectively infuse / deliver diagnostics or therapeutic fluids when utilizing the optional HYPER PULSETM Fluid Delivery feature. The JETi Suction Tubing is a sterile single use device that incorporates the pressure monitoring sensor and valve into a single enclosure, that is in-line with the aspiration lumen, for the handheld switch. When the handheld switch is activated, within the aspiration lumen, the diluted thrombus and saline is then drawn back through the primary lumen of the JETi Catheter and deposited into the vacuum source (JETi Non-sterile Canister Set) via the JETi Suction Tubing. When the handheld switch is de-activated, a valve closes, stopping the flow of thrombus, and a relief valve inside the SDU briefly opens and closes to reduce foaming at the vacuum source (JETi Non-sterile Canister Set). The SDU contains a microprocessor-controller circuit board and firmware that monitors various functions of the motor and vacuum to ensure that the device is functioning as expected. A Liquid Crystal Display (LCD) screen on the front panel of the SDU indicates to the user the status of the system. Several safety features are incorporated into the firmware to ensure proper functionality. The SDU is supported by a mobile, height adjustable cart with an integrated IV pole. Energy is provided by a 24-volt external power supply, which is connected to the main supply. The external power supply is provided with the SDU and is part of the system

    AI/ML Overview

    The provided text is a 510(k) summary for the JETi™ Hydrodynamic Thrombectomy System, which is a medical device for removing thrombus from peripheral vasculature. This document focuses on demonstrating substantial equivalence to a predicate device, rather than reporting on a study that proves the device meets specific acceptance criteria in terms of clinical performance or diagnostic accuracy. Therefore, information regarding acceptance criteria for clinical performance, sample sizes for test/training sets, expert qualifications, ground truth establishment, or multi-reader multi-case studies are not available in this document.

    The document primarily details the device's technical specifications and compares them to predicate devices to establish substantial equivalence for regulatory clearance. It also mentions non-clinical testing for areas like packaging, human factors, and electromagnetic compatibility (EMC).

    Here's a breakdown of the information that is available based on your request:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document does not provide a formal table of clinical acceptance criteria and device performance as would be seen in a study evaluating diagnostic accuracy or clinical outcomes. Instead, it focuses on non-clinical testing and substantial equivalence to a predicate device.

    Test CategoryAcceptance Criteria (Implicit)Reported Device Performance
    Non-Clinical Testing
    Packaging ValidationPer ASTM D4332, ASTM 4169, and Abbott's internal procedures; all data meet pre-determined product specifications.All data met the acceptance criteria and fell within pre-determined product specifications.
    Human Factors EvaluationIFU conveys appropriate information clearly and concisely to support safe and effective use.The evaluation demonstrated that the IFU conveys the appropriate information in a clear and concise manner, i.e., facilitates understanding of the device usage to support safe and effective use of the device.
    EMC Testing (IEC 60601-1-2)Conformance with emission limits (CISPR 11 Class A), specific ESD, radiated RF immunity, proximity field immunity, power frequency magnetic fields, conducted disturbances, electrical fast transient/burst, surge immunity, current harmonics, voltage fluctuation and flicker test.The device met the acceptance criteria for all listed EMC tests.

    2. Sample size used for the test set and the data provenance:

    • Not Applicable / Not Provided for clinical performance. The document explicitly states "No clinical testing is provided in this pre-market notification."
    • For non-clinical testing:
      • Packaging Validation: The sample size is not specified, but the data provenance would be internal Abbott testing.
      • Human Factors Evaluation: The sample size (number of users) is not specified, but the data provenance would be from the human factors study conducted by Abbott.
      • EMC Testing: The sample size is not specified (typically one or a few devices tested), and the data provenance would be from laboratory testing conforming to IEC standards.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not Applicable / Not Provided. This information is relevant for clinical studies involving expert interpretation for ground truth, which were not part of this submission.

    4. Adjudication method for the test set:

    • Not Applicable / Not Provided. This information is relevant for clinical studies that involve multiple readers and potentially discrepancies in their assessments for ground truth, which were not part of this submission.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No. The document explicitly states "No clinical testing is provided in this pre-market notification." This device is a physical thrombectomy system, not an AI-assisted diagnostic or treatment planning tool for which MRMC studies would typically be conducted.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • Not Applicable. This is a physical medical device, not an algorithm, so "standalone" performance in the context of an algorithm is not relevant.

    7. The type of ground truth used:

    • Not Applicable / Not Provided for clinical performance. For the non-clinical tests mentioned:
      • Packaging Validation: Ground truth is based on established ASTM standards and internal product specifications.
      • Human Factors Evaluation: Ground truth relates to adherence to human factors principles and user understanding, evaluated through methods like usability testing.
      • EMC Testing: Ground truth is defined by the limits and methodologies specified in the IEC 60601-1-2 standard.

    8. The sample size for the training set:

    • Not Applicable / Not Provided. This device is not an AI/ML algorithm that would typically use a "training set."

    9. How the ground truth for the training set was established:

    • Not Applicable / Not Provided. As this is not an AI/ML algorithm requiring a training set, the concept of establishing ground truth for a training set does not apply.
    Ask a Question

    Ask a specific question about this device

    K Number
    K213388

    Validate with FDA (Live)

    Date Cleared
    2022-04-04

    (172 days)

    Product Code
    Regulation Number
    870.5150
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cannula is indicated for
    - · the non-surgical removal of thrombi or emboli from venous vasculature.
    - · aspiration of contrast media and other fluids from venous vasculature.

    The Cannula is intended for use in the venous system.

    The Handle is indicated as a vacuum source for the AlphaVac MMA System.

    Device Description

    The AlphaVac Multipurpose Mechanical Aspiration (MMA) F1885 System is a single use-overwire catheter-based system that facilitates the removal of thrombus, embolus, or clot during minimally invasive percutaneous procedures. The AlphaVac MMA F186 System is comprised of six main components packaged together:

    • . a flexible AlphaVac Cannula with self-expandable, nitinol reinforced, angled funnel shaped distal tip (18F)
    • AlphaVac Sheath (22F)
    • AlphaVac Obturator (17F) ●
    • AlphaVac Handle .
    • . Waste Bag and Tubing

    The AlphaVac Cannula is placed within target vasculature using standard percutaneous vascular access techniques (i.e., Seldinger) and commonly available vascular access tools (e.g., guidewire, vascular introducers, etc.). Once the cannula is in place, the AlphaVac Handle and waste bag is connected and primed. The AlphaVac Cannula is advanced out of the sheath and the nitinol basket automatically expands into a funnel, aiding in the removal of thrombus, emboli, and clot. The aspiration handle is pulled back creating suction and pulling the material into the catheter, removing it from the vasculature. The aspirated material is captured and contained within the waste bag for disposal. Target vessels include, but are not limited to, the iliofemoral vein, Inferior Vena Cava (IVC), Superior Vena Cava (SVC), and Right Heart (Atrium (RA)). The device is provided in ~85° (AlphaVac F1885) angled configuration.

    AI/ML Overview

    The provided document is a 510(k) Premarket Notification from the FDA for the AlphaVac Multipurpose Mechanical Aspiration (MMA) F1885 System. It describes the device, its indications for use, and the studies performed to demonstrate its substantial equivalence to a predicate device.

    There is no information in this document related to any AI/ML model, ground truth, expert readers, or retrospective/prospective studies on patient data. This document focuses on the mechanical and functional performance of a medical device (aspiration catheter) and its substantial equivalence to a predicate device.

    Therefore, I cannot provide a response that includes information about "acceptance criteria and the study that proves the device meets the acceptance criteria" in the context of an AI/ML device. The request specifically asks for details pertinent to AI/ML device evaluation (e.g., sample size for test/training sets, data provenance, number of experts for ground truth, MRMC studies, standalone performance, etc.), which are not present in this document.

    The document outlines the following performance data to support substantial equivalence for the device itself (not an AI/ML component):

    Acceptance Criteria and Device Performance (Mechanical/Functional Device)

    The document states that "Comprehensive bench testing (integrity and functional performance) was performed to support substantial equivalence of the specified predicate device. The AlphaVac MMA F1885 System met all specified design and performance requirements below."

    The acceptance criteria are implied to be the successful demonstration that the device performs according to its design and functional requirements. The reported device performance is that it "met all specified design and performance requirements."

    Acceptance Criteria CategoryReported Device Performance
    Dimensional TestingMet requirements
    Visual InspectionMet requirements
    Tensile TestingMet requirements
    Column StrengthMet requirements
    Cannula and Funnel ActuationMet requirements
    Distal Cannula Shape ManipulationMet requirements
    Hub RotationMet requirements
    Distal Tip FunctionalityMet requirements
    Kink ResistanceMet requirements
    RadiopacityMet requirements
    FlushabilityMet requirements
    Product Interface (Compatibility) TestingMet requirements
    Push/Pull/Retraction ForceMet requirements
    Leak TestingMet requirements
    Siphoning TestingMet requirements
    Fluid Volume RemovalMet requirements
    Handle Lock TestingMet requirements
    Pressure TestingMet requirements
    Handle Pull ForceMet requirements
    Human Factors Evaluation/Usability EvaluationMet requirements
    Simulated UseMet requirements
    TorqueMet requirements
    Sterilization/Shelf LifeConfirmed suitability, integrity, and sterility
    BiocompatibilityMet requirements (ISO 10993; cytotoxicity, sensitization, irritation, systemic toxicity, pyrogenicity, hemocompatibility with acceptable results)

    Non-Applicable AI-Specific Information from the Document:

    The following points are not addressed or are not applicable based only on the provided text, as the document describes a mechanical medical device, not an AI/ML system:

    • Sample size used for the test set and data provenance: No information on patient data test sets as it's a mechanical device.
    • Number of experts used to establish the ground truth for the test set and qualifications: Not applicable for a mechanical device.
    • Adjudication method for the test set: Not applicable.
    • If a multi-reader multi-case (MRMC) comparative effectiveness study was done: Not applicable.
    • If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable.
    • The type of ground truth used (expert consensus, pathology, outcomes data, etc): Not applicable.
    • The sample size for the training set: Not applicable.
    • How the ground truth for the training set was established: Not applicable.

    In summary, the provided text describes the regulatory clearance for a physical medical device (aspiration catheter) based on a demonstration of substantial equivalence through bench testing, biocompatibility, and sterilization validation, not an AI/ML product.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 10