Search Results
Found 479 results
510(k) Data Aggregation
(60 days)
The 3.0T AIR™ 32CH HNA is a receive-only RF Coil designed for use with GE HealthCare 3.0T MRI systems. The coil is indicated for high-resolution magnetic resonance imaging (MRI) of the head and brain. When used with a Posterior Array in the MRI System patient table it also includes neck, cervical spine, neurovascular structures, upper thoracic spine, and brachial plexus imaging. The nucleus detected is hydrogen.
The 3.0T AIR 32CH HNA is a receive-only radio frequency coil engineered to deliver optimal signal-to-noise ratio, uniform anatomical coverage, and high acceleration capabilities, including multiband imaging. It is intended for high-resolution magnetic resonance imaging (MRI) of the head and brain. When used in conjunction with the Posterior Array in the MRI system's patient table, it also supports imaging of the neck, cervical spine, neurovascular structures, upper thoracic spine, and brachial plexus. The nucleus detected is hydrogen. This coil is compatible with GE HealthCare 3.0T MRI systems.
The 3.0T AIR 32CH HNA is designed to be used by a Registered MRI Technologist in a hospital or clinical setting. The Registered MRI Technologist will operate the scanner from the control room. If the patient is claustrophobic another MRI Technologist or clinical staff member may stay in the magnet room with the patient.
N/A
Ask a specific question about this device
(22 days)
The Philips Neurovascular MR Coil is intended to be used in conjunction with a Philips 1.5T or 3T Magnetic Resonance Scanner to produce diagnostic images of the anatomy of interest that can be interpreted by a trained physician.
A general description of the subject devices, which are part of the Philips Neurovascular MR Coil Family is given below:
The dS Base 1.5T and dS Base 3.0T are lightweight, 8-channel, phased-array coil that are designed to be used independently or in combination with the dS Head or dS HeadNeck coil. The dS Base coil also can be used for extremities and pediatric examinations or can be combined with the dS Posterior coil which is integrated in the patient support of the compatible Magnetic Resonance (MR) Systems for total spine imaging. The dS Base coil can stay on the table for most examinations without exchanging coils, thereby, improving workflow. These coils are connected to the flex connect socket of the compatible MR System.
The dS Head 1.5T and dS Head 3.0T are 7-channel receive only coils, which are designed to be used in combination with the dS Base (bottom) coil to create a 15-channel coil with or without the dS Posterior coil which is integrated in the patient support of the compatible MR Systems for total spine imaging. The coil is most frequently used for imaging the head/brain and its vasculature. The coil can also be used for extremities and pediatric examinations. These coils are available in both 1.5T and 3.0T and are connected to the flex connect socket of the compatible MR System.
The dS HeadNeck 1.5T and dS HeadNeck 3.0T are 8-channel receive only coils, which are designed to be used in combination with the dS Base (bottom) coil to create a 16-channel coil with or without the dS Posterior coil which is integrated in the patient support of the compatible MR Systems for total spine imaging. The coil is used for brain, head, neck, cervical spine, and neurovascular imaging. The coil also can be used for extremities and pediatric examinations. These coils are available in both 1.5T and 3.0T and are connected to the flex connect socket of the compatible MR System
The dS HeadNeck coil can be used either alone or in combination with the dS Anterior coil and dS Posterior coil. When used in combination with the dS Anterior coil and dS Posterior coil for Whole Body exams this is called a 'Whole Body solution.
N/A
Ask a specific question about this device
(24 days)
The InkSpace Imaging Small Body Array is a receive-only coil, used for obtaining diagnostic images of general human anatomy, such as cardiac, hip, shoulder, liver, knee, and ankle in Philips 3.0T magnetic resonance imaging systems. These images, when interpreted by a trained physician, yield information that may assist in diagnosis.
The InkSpace Imaging Small Body Array is a phased array, receive-only coil designed to work on Philips 3.0 Tesla (3.0T) MRI scanners. It consists of 12 elements which are optimized to be lightweight and flexible to easily conform to a patient's anatomy, providing high signal-to-noise ratio. The elements are enclosed in a soft padded pouch which can be wiped clean. The array is designed for proton imaging at 3.0 Tesla and has an optimal field of view of 27x25cm.
N/A
Ask a specific question about this device
(254 days)
Probe: The DxTx e²Coil probes are recommended for high-resolution magnetic resonance imaging, including spectroscopy, of the prostate and surrounding pelvic tissue in the male human anatomies and are specifically designed for use with the appropriate e²Coil Interface Device and Intermediate Cable Assembly. The one-time use, disposable e²Coil probe has been designed to be inserted into the human rectum. The e²Coil probe may be inserted by a trained healthcare professional, depending on state or country law, who has training in e²Coil probe insertion.
Interface Device: The Siemens 3.0T Endo Interface II with Tim 4G SlideConnect (e²Coil™) provides interface and support functions to allow the use of 3.0T disposable e²Coil probes with Siemens 3.0T MRI Systems with a Tim 4G connector. Only trained healthcare professionals are intended to operate this device.
The e²Coil™ Imaging System for the Siemens MAGNETOM 3.0T MRI Systems with Tim 4G Connector is a combination of the following two devices for improving the diagnostic MR image of the prostate and its surrounding pelvic tissues:
- Siemens 3.0T Endo Interface Gen II with Tim 4G Slide Connect (e2Coil)
- Endorectal MRI Coil II for 3.0T MR Imaging of the Prostate (e2Coil) – Siemens
- Coil contains two loops and four channels
The intended contact duration of the device is less than 60 minutes.
No components of this device contain medicinal substances, tissues or blood products.
The patient contacting device component materials are Latex, PVC, and Polymer.
The provided FDA 510(k) clearance letter and summary describe the acceptance criteria and the study that proves the device meets those criteria for the e²Coil™ Imaging System.
Here's an breakdown:
1. Table of Acceptance Criteria and Reported Device Performance
| Acceptance Criteria Category | Specific Criteria/Tests | Reported Device Performance |
|---|---|---|
| Biocompatibility | - Cytotoxicity | Complies with FDA Guidance 635 and ISO 10993-1:2018 |
| - Irritation | Complies with FDA Guidance 635 and ISO 10993-1:2018 | |
| - Sensitization | Complies with FDA Guidance 635 and ISO 10993-1:2018 | |
| Electrical Safety & EMC | - IEC 60601-1 Standard | Complies with IEC 60601-1 standard for EMC |
| Mechanical Testing | - Push | Complies with IEC 60601-1 standard for mechanical strength |
| - Impact | Complies with IEC 60601-1 standard for mechanical strength | |
| - Drop | Complies with IEC 60601-1 standard for mechanical strength | |
| - Moulding Stress Relief | Complies with IEC 60601-1 standard for mechanical strength | |
| MR Safety | - IEC 60601-2-33 | MR Conditional compliant to the 3.0T environment per IEC 60601-2-33 |
| Signal to Noise Ratio (SNR) | - Higher than scanner body coil alone (NEMA MS 1 2.3.2.4 Method 4) | Consistently higher than the SNR of the scanner body coil alone on the Siemens 3.0T Skyra scanner |
| Uniformity | - Good signal uniformity (NEMA MS 3 and IEC 62464-1 in axial, coronal, and sagittal axes) | Signal showed good uniformity per NEMA MS 3 and IEC 62464-1 in the axial, coronal, and sagittal axes |
2. Sample size used for the test set and the data provenance:
The document does not explicitly state the specific sample sizes for each test set (e.g., number of coils for mechanical testing, number of measurements for SNR). The nature of the device (an MRI coil) suggests that testing would involve a representative number of manufactured units rather than patient data.
The data provenance is internal testing performed by the manufacturer, DxTx Medical, Inc., for regulatory submission. There is no mention of external data or patient data provenance in this summarized document.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
This information is not provided in the document. The studies performed (biocompatibility, electrical safety, mechanical, MR safety, SNR, uniformity) are primarily objective engineering and scientific tests based on established standards (e.g., ISO, IEC, NEMA), rather than interpretations by medical experts to establish a "ground truth" in the diagnostic sense.
4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:
This is not applicable to the types of performance tests conducted for this device. Adjudication methods like 2+1 or 3+1 are typically used in clinical studies where expert consensus is needed to establish ground truth for diagnostic accuracy, which is not the focus of these engineering and safety tests.
5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance:
This is not applicable. The e²Coil™ Imaging System is an MRI coil, a hardware component, not an AI-powered diagnostic software. Therefore, an MRMC study related to human readers improving with AI assistance would not be relevant to this device.
6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:
This is not applicable, as the device is an MRI coil, not a standalone algorithm.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
The "ground truth" for the performance characteristics measured in this submission is based on established engineering and scientific standards and physical properties. For example:
- Biocompatibility: Adherence to ISO 10993-1:2018 and FDA Guidance 635.
- Electrical Safety & EMC: Compliance with IEC 60601-1.
- Mechanical Testing: Compliance with IEC 60601-1.
- MR Safety: Compliance with IEC 60601-2-33.
- SNR & Uniformity: Adherence to NEMA MS 1 and NEMA MS 3/IEC 62464-1 standards.
These are objective, measurable criteria, not subjective interpretations requiring expert consensus or clinical outcomes data in the usual sense.
8. The sample size for the training set:
Not applicable. This device is an MRI coil, not a machine learning model, so there is no "training set."
9. How the ground truth for the training set was established:
Not applicable, as there is no training set for this device.
Ask a specific question about this device
(59 days)
The 16CH Flex SPEEDER Medium is intended for use with Canon 1.5T MR systems to produce diagnostic images of general human anatomy that can be interpreted by a trained physician.
The 16ch Flex SPEEDER Large coil is intended for use with Canon 1.5T MR systems to produce diagnostic images of general human anatomy that can be interpreted by a trained physician.
The 16ch Flex Speeder Medium and 16ch Flex Speeder Large coils are a receive-only, 16-channel phased array coil designed for magnetic resonance imaging (MRI) using the Canon 1.5T MR systems. The 16ch Flex Speeder Medium and 16ch Flex Speeder Large coils are intended to be used for general anatomies.
This document describes the acceptance criteria and the study conducted to prove that the 16ch Flex SPEEDER Medium 1.5T and 16ch Flex SPEEDER Large 1.5T coils meet these criteria.
1. Table of Acceptance Criteria and Reported Device Performance
| Acceptance Criterion | Reported Device Performance |
|---|---|
| Signal-to-Noise Ratio (SNR) | Analyzed per NEMA MS-9 (using alternate method 2.5 from MS-6) and met pre-determined acceptance criteria. |
| Image Uniformity | Analyzed per NEMA MS-9 (primary method from MS-6) and met pre-determined acceptance criteria. |
| Diagnostic Quality Images | Clinical images obtained from volunteer scanning of general human anatomy (upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine) demonstrated diagnostic quality. |
| Electrical Safety | Tested in accordance with IEC standards, data supports safety. |
| Electromagnetic Compatibility (EMC) | Tested in accordance with IEC standards, data supports safety. |
| Surface Heating | Measured temperature of the coil surface never exceeded the maximum limit of 41°C, tested in accordance with AAM/ANSI EN60601-1. |
2. Sample Size Used for the Test Set and Data Provenance
- Sample Size: Clinical images were obtained from "volunteer scanning of general human anatomy." The exact number of volunteers is not specified.
- Data Provenance: The document does not explicitly state the country of origin. The study appears to be prospective, as clinical images were "obtained for the 16CH Flex SPEDER Medium and Large 1.5T from upper and lower extremities, chest, abdomen, pelvis, head, neck and spine."
3. Number of Experts Used to Establish Ground Truth and Qualifications
- The document states that the diagnostic images are "interpreted by a trained physician." It does not specify the number of physicians, their specific qualifications (e.g., years of experience), or how ground truth was established by these physicians for the test set.
4. Adjudication Method for the Test Set
- The document does not describe any specific adjudication method (e.g., 2+1, 3+1). It only mentions that images are "interpreted by a trained physician," implying a single interpretation per image for diagnostic quality assessment.
5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study
- No MRMC comparative effectiveness study was done. The study compares the new device to pre-determined acceptance criteria and implicitly to the predicate device in terms of performance (e.g., "performs as well as or better than the predicate device"), but not in terms of human reader improvement with AI assistance. This is an MRI coil, not an AI-driven device.
6. Standalone Performance Study
- A standalone performance study was done for the device itself. The document describes non-clinical bench testing (SNR, uniformity, electrical safety, EMC, surface heating) and clinical imaging with volunteers to assess diagnostic image quality. This refers to the performance of the coil as a medical device without explicit human-in-the-loop performance measurement.
7. Type of Ground Truth Used
- For technical performance (SNR, uniformity, electrical safety, EMC, surface heating): Ground truth was established against engineering specifications and industry standards (NEMA MS-9, IEC, AAM/ANSI EN60601-1).
- For diagnostic image quality: The ground truth was established through visual assessment by a "trained physician" of "diagnostic quality images." This is essentially expert consensus/interpretation of the acquired images.
8. Sample Size for the Training Set
- This information is not applicable as this is a physical medical device (MR coil) and not an AI/machine learning algorithm requiring a separate training set.
9. How the Ground Truth for the Training Set Was Established
- This information is not applicable.
Ask a specific question about this device
(23 days)
The InkSpace Imaging Small Body Array is a receive-only coil, used for obtaining diagnostic images of general human anatomy in adult and pediatric patients such as cardiac, spine, shoulder, elbow, knee, foot, and prostate in Siemens 1.5T magnetic resonance imaging systems. These images, when interpreted by a trained physician, yield information that may assist in diagnosis.
The InkSpace Imaging Small Body Array is a phased array, receive-only coil intended to work with Siemens 1.5T MRI scanners for body MR imaging examinations. The coil is comprised of 24 total channels, with two individual flexible pads, each containing 12 individual elements. The elements are flexible to conform to patients' anatomies.
The provided text does not describe a study involving a device that uses AI or machine learning, nor does it provide a comparative effectiveness study with human readers. Instead, it describes a Magnetic Resonance (MR) Receive-only Coil and its substantial equivalence to a predicate device.
Therefore, many of the requested elements about acceptance criteria for AI performance, sample sizes for test/training sets, expert adjudication, MRMC studies, and ground truth establishment are not applicable based on the provided document.
However, I can extract information related to the device's performance testing from the document:
Device: InkSpace Imaging Small Body Array (a receive-only coil for MRI systems)
1. Table of acceptance criteria and the reported device performance:
The document refers to performance testing in accordance with the "Magnetic Resonance (MR) Receive-only Coil – Performance Criteria for Safety and Performance Based Pathway" guidance document. It lists the tests performed, implying these tests are the acceptance criteria. The performance results are stated to have met established specifications.
| Acceptance Criteria (Nonclinical Test) | Reported Device Performance |
|---|---|
| Image Signal to Noise (SNR) | Met established specifications |
| Image Uniformity | Met established specifications |
| Surface Heating | Met established specifications |
| Decoupling Circuit | Met established specifications |
| EMC - Immunity, Electrostatic Discharge | Met established specifications |
| General Electrical/Mechanical Safety | Met established specifications |
| Acquired Image Quality | Met established specifications (Analyzed based on sample clinical images and reviewed by a board-certified radiologist) |
2. Sample size used for the test set and the data provenance:
- Sample Size: The document does not specify exact sample sizes (e.g., number of coils tested, number of images reviewed) for the nonclinical tests. It refers to "sample clinical images" for the acquired image quality analysis.
- Data Provenance: Not specified in terms of country of origin. The test data are generated from nonclinical bench testing and analysis of sample clinical images. The data is retrospective in the sense that the images are existing data used for evaluation.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- Number of Experts: "a board-certified radiologist" (implies one, though it could be a general statement about the type of expert).
- Qualifications: "board-certified radiologist."
4. Adjudication method for the test set:
- The document mentions a "review of their clinical quality by a board-certified radiologist." This implies a single expert review, not an adjudication process involving multiple experts for consensus.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- No. An MRMC study was not performed. This device is a passive component (MRI coil), not an AI/ML algorithm that assists human readers.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
- N/A. This is not an algorithm; it's hardware. Its performance is assessed through its physical and electromagnetic properties, with the final output (images) being subject to human interpretation.
7. The type of ground truth used:
- For "Acquired Image Quality," the ground truth was established by the subjective "clinical quality" assessment by a "board-certified radiologist." Other tests (SNR, Uniformity, etc.) likely relied on objective measurements against engineering specifications.
8. The sample size for the training set:
- N/A. This device does not involve a training set as it's a hardware component, not an AI/ML model.
9. How the ground truth for the training set was established:
- N/A. (See point 8)
Ask a specific question about this device
(28 days)
The Polarean XENOVIEW 3.0T Chest Coil is to be used in conjunction with compatible 3.0T Magnetic Resonance Imaging (MRI) scanners and approved xenon Xe 129 hyperpolarized for oral inhalation of lung ventilation in adults and pediatric patients aged 12 years and older.
The Polarean XENOVIEW 3.0T Chest Coil (hereafter Chest Coil) is a flexible, single channel, transmit-receive (T/R) RF coil tuned to 123xe frequency on a 3.0T MRI magnetic field in order to image 129Xe nuclei while the patient is positioned inside a compatible multi-nuclear-capable MRI scanner. The Chest Coil is intended to be worn by a patient who inhales hyperpolarized 100%e gas (XENOVIEW) to obtain an MR image of the regional distribution of hyperpolarized 199xe in the lungs. The coil is constructed of a durable, flexible circuit board material within which the antenna elements and all electronic components are contained. These components are electrically isolated from the rest of the coil packaging by being enclosed within suitable non-conductive. water-rated, and flame-rated materials. A layer of padding is located on either side of the coil circuitry to provide patient comfort and protection against potential heating generated by circuitry components. The RF coil is a "fixed matching and tuning device" (i.e. not tunable by the operator), thereby eliminating the need to tune and match it for every patient.
The provided document describes the Polarean XENOVIEW 3.0T Chest Coil (subject device) and its substantial equivalence to a predicate device (K231647). The submission focuses on adding compatibility with General Electric Healthcare (GEHC) 3T MR750 and Premier MRI scanners.
Here's an analysis of the acceptance criteria and the study that proves the device meets them, based on the provided text:
1. Table of Acceptance Criteria and Reported Device Performance
The document does not explicitly state acceptance criteria in a quantitative table format with corresponding reported device performance for a diagnostic measurement. Instead, it outlines performance and safety standards against which the device was tested. The "performance" here refers to the device's functional integrity and safety within an MRI environment, rather than a diagnostic accuracy performance (e.g., sensitivity, specificity).
Implicit Acceptance Criteria and Demonstrated Performance:
| Acceptance Criteria Category | Specific Standard/Test Adhered To | Reported Device Performance |
|---|---|---|
| Performance - Bench Tests | NEMA MS 6-2008 (R2014): Signal-to-Noise Ratio & Image Uniformity | Testing repeated; "confirm the safety and performance" |
| NEMA MS 8-2016: Specific Absorption Rate (SAR) | Testing repeated; "confirm the safety and performance" | |
| NEMA MS 14-2019: RF Coil Heating | Testing repeated; "confirm the safety and performance" | |
| Electrical Safety & Electromagnetic Compatibility | IEC 60601-1:2005/(R)2012 and A1:2012: Basic Safety & Essential Performance | Testing repeated; "confirm the safety and performance" |
| IEC 60601-2-33:2015: Basic Safety & Essential Performance of MR Equipment | Testing repeated; "confirm the safety and performance" | |
| IEC 60601-1-2:2020: Electromagnetic Compatibility | Testing repeated; "confirm the safety and performance" | |
| Biocompatibility | ISO 10993-1:2018: Biocompatibility (general) | Testing performed; "confirm the safety and performance" |
| ISO 10993-5:2009: Cytotoxicity | Testing performed; "confirm the safety and performance" | |
| ISO 10993-10:2010: Sensitization | Testing performed; "confirm the safety and performance" | |
| ISO 10993-10:2010: Irritation | Testing performed; "confirm the safety and performance" |
Note: The document states "confirm the safety and performance" for each category, but does not provide specific numerical outcomes or thresholds that were met. The acceptance is implied by the statement that the device was "verified and validated in accordance with documented Verification & Validation plans and protocols to ensure conformance with established performance criteria" and the conclusion that it is "as safe, as effective, and performs as well as or better than" the predicate.
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
The document explicitly states: "No clinical tests were required to demonstrate substantial equivalence." This means there was no patient-based test set for evaluating diagnostic or clinical performance. The testing was non-clinical (bench testing) and therefore, concepts of sample size, data provenance (country of origin, retrospective/prospective) are not applicable in the context of clinical studies for this device.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
This information is not applicable as no clinical studies were performed, and thus no ground truth derived from expert review or clinical outcomes was established for a test set. The validation was based on engineering and safety standards.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
This information is not applicable as no clinical studies were performed, and thus no expert adjudication of clinical data was needed.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
This information is not applicable. The device is a physical MRI coil, not an AI-powered diagnostic tool, and no clinical studies were required or conducted.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
This information is not applicable. The device is a physical MRI coil, not an algorithm.
7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)
For the non-clinical testing, the "ground truth" was adherence to established international and national standards for medical device safety and performance, specifically related to MRI coils (e.g., NEMA, IEC, ISO standards). There was no clinical ground truth established from patient data.
8. The sample size for the training set
This information is not applicable as no algorithmic training was involved. The device is a physical MRI coil.
9. How the ground truth for the training set was established
This information is not applicable as no algorithmic training was involved.
Ask a specific question about this device
(25 days)
The dS Knee Coil 8ch 1.5T is to be used in conjunction with Philips 1.5T Magnetic Resonance Scanner to produce diagnostic images of Knee that can be interpreted by a trained physician.
The dS Knee Coil 8ch 1.5T is an 8 channel phased array, receive only coil with a rigid volume and designed to be used in conjunction with 1.5T Magnetic Resonance Scanner for high resolution imaging of the left or right knee. The split design and single handle allows easy setup. The coil can be slightly rotated relative to its base plate to ease coil setup and enhance patient comfort. The coil conforms snugly to the anatomy for excellent signal-to-noise ratio. This coil is used independently and cannot be combined with any other coil and is available for Philips 1.5T Prodiva and MR 5300 MR Systems.
The provided text K242879 is a 510(k) summary for the Philips dS Knee Coil 8ch 1.5T. It describes the device, its indications for use, and a summary of performance data. However, this document does not contain the detailed clinical study results or acceptance criteria in the format requested, particularly for an AI/software-based medical device performance evaluation.
The document states:
- "Acquired Image quality was assessed by a U.S. Board Certified radiologist to confirm images produced on the subject coil are sufficient quality for diagnostic use."
- "Substantially equivalent performance is demonstrated by meeting all criterion in the quidance "Magnetic Resonance (MR) Receive-only Coil –Performance Criteria for Safety and Performance Based Pathway" issued on December 11, 2020."
This indicates that the performance evaluation for this hardware device (a medical coil) focused on image quality for diagnostic use, rather than the performance of an AI algorithm or software. Therefore, many of the requested elements, such as MRMC studies, standalone algorithm performance, ground truth establishment for training, and sample sizes for AI model development, are not applicable or detailed in this document because it's not an AI/ML device submission.
Based only on the provided text, I can infer some information relevant to the intent behind your questions, but I cannot provide the specific details of an AI/ML study.
Here's how I can interpret the provided text in the context of your request, filling in with "Not Applicable" or "Not specified" where the document does not provide the information for an AI/ML device:
Study Type: This is a performance study for a hardware medical device (MRI coil), not an AI/ML software device. The evaluation focuses on assuring the generated images are of diagnostic quality.
1. A table of acceptance criteria and the reported device performance
| Acceptance Criteria (Inferred from guidance) | Reported Device Performance (Inferred) |
|---|---|
| Images sufficient quality for diagnostic use | Confirmed sufficient quality (per radiologist assessment) |
| Compliance with FDA guidance "Magnetic Resonance (MR) Receive-only Coil - Performance Criteria for Safety and Performance Based Pathway" | All criteria met |
| Safety (IEC 60601-1, ISO 10993-1, etc.) | Met (implied by 510(k) clearance) |
| Performance (NEMA-MS-1, IEC62464-1 for image uniformity, SNR) | Met (implied by 510(k) clearance and "sufficient quality") |
2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
- Sample Size: Not specified for the clinical image quality assessment. The document only mentions "Acquired Image quality was assessed."
- Data Provenance: Not specified. It's likely prospective imaging data acquired with the device for validation, but the document doesn't explicitly state this.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
- Number of experts: Singular ("a U.S. Board Certified radiologist").
- Qualifications: "U.S. Board Certified radiologist." Specific experience level (e.g., 10 years) is not mentioned.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
- Adjudication method: Not applicable/not specified. The assessment appears to be a single read. This is a hardware image quality assessment, not an AI diagnostic study usually requiring complex adjudication.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
- MRMC study: No, this was not an MRMC study. It was an assessment of the image quality produced by the coil, not a study comparing human reader performance with or without AI assistance.
- Effect size: Not applicable.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
- Standalone performance: Not applicable. This is not an AI algorithm. The performance being evaluated is the image generation capability of the MRI coil.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
- Type of ground truth: Expert assessment by a U.S. Board Certified radiologist to confirm "sufficient quality for diagnostic use." This is a form of expert consensus on image utility, rather than a clinical ground truth for a specific diagnosis (like pathology).
8. The sample size for the training set
- Sample Size for Training Set: Not applicable. This is a hardware device, not an AI/ML model that requires a training set.
9. How the ground truth for the training set was established
- Ground Truth for Training Set: Not applicable.
Ask a specific question about this device
(21 days)
The dS Wrist Coil 8ch 1.5T is intended to be used in conjunction with Philips 1.5T Magnetic Resonance Scanner to produce diagnostic images of the wrist that can be interpreted by a trained physician.
The dS Wrist Coil 8ch 1.5T is an 8-channel phased-array coil with rigid volume coils of 8 elements that closely encircle the wrist for high SNR. This coil for Prodiva and MR5300 is a one-piece, hinged design for easy patient set-up. To reduce patient motion artifacts, the dS Wrist coil includes one rigid base plate to fixate the coil & allowing for overhead and at the side examinations. This coil is only available in 1.5T. This coil is used independently and cannot be combined with any other coils
This FDA 510(k) summary describes a new medical device, the Philips dS Wrist Coil 8ch 1.5T, which is a magnetic resonance (MR) receive-only coil for wrist imaging. The document claims the device is substantially equivalent to a predicate device (8ch Wrist Coil, K222325). However, it does not provide a table of acceptance criteria and reported device performance, nor details of a study proving the device meets specific acceptance criteria related to diagnostic performance for image quality.
Instead, it lists non-clinical and clinical performance testing performed to demonstrate safety and effectiveness. The clinical testing merely states that "Acquired Image quality was assessed by U.S. Board Certified radiologist to confirm that images produced on the subject coil have sufficient quality for diagnostic use." This is a very high-level statement and lacks the specificity required to answer your questions regarding acceptance criteria, study details, and quantifiable performance.
Therefore, many of your questions cannot be answered from the provided text. Below, I will answer what is inferable from the document and explicitly state where information is missing.
1. A table of acceptance criteria and the reported device performance
| Acceptance Criteria (Inferred from clinical testing description) | Reported Device Performance |
|---|---|
| Images produced on the subject coil have sufficient quality for diagnostic use. | Achieved (as confirmed by U.S. Board Certified radiologist review) |
Missing Information: The document does not provide specific quantifiable acceptance criteria (e.g., SNR values, image uniformity metrics thresholds) or detailed reported performance against such criteria. The statement is qualitative.
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
Missing Information: The document does not specify the sample size for the clinical test set, the country of origin of the data, or whether it was retrospective or prospective.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
Inferred Information: The ground truth (or assessment of image quality for diagnostic use) was established by "U.S. Board Certified radiologist."
Missing Information: The exact number of radiologists, their specific years of experience, or any further specific qualifications are not provided.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Missing Information: The document does not mention any adjudication method for the radiologists' assessments.
5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Missing Information: The device described is a medical imaging coil, not an AI-powered diagnostic tool. Therefore, an MRMC comparative effectiveness study regarding "human readers improve with AI vs without AI assistance" is not applicable and not mentioned.
6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done
Missing Information: The device is a hardware component (an MR coil), not an algorithm. Therefore, a standalone algorithm performance study is not applicable and not mentioned.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
Inferred Information: For the clinical performance assessment, the "ground truth" for sufficient image quality was based on the qualitative assessment of "U.S. Board Certified radiologist." This can be considered a form of expert consensus or expert review.
8. The sample size for the training set
Missing Information: The document does not describe any machine learning or AI component that would require a "training set." This question is not applicable to an MR coil.
9. How the ground truth for the training set was established
Missing Information: As there is no mention of a training set or AI/ML components, this question is not applicable to the device described.
Ask a specific question about this device
(25 days)
The dS FootAnkle Coil 8ch 1.5T is intended to be used in conjunction with Philips Magnetic Resonance Scanner to produce diagnostic images of the foot and ankle that can be interpreted by a trained physician.
The dS FootAnkle Coil 8ch 1.5T is a phased-array, receive-only coil with rigid volume consisting of 8 elements. This coil is a ski-boot-shaped coil designed for optimum coverage and highresolution visualization of the ankle and entire foot down to the toes. The coil design and element lavout allow for either large field of view (FOV) imaging of the whole foot or small FOV high resolution imaging of ankle joints. The coil is easy to set up and can be used with the patient's foot positioned vertically. These coils are used independently and cannot be combined with any other coils and are available for 1.5T Prodiva/ MR 5300 MR Systems.
The provided text is a 510(k) summary for the dS FootAnkle Coil 8ch 1.5T. It primarily focuses on demonstrating substantial equivalence to a predicate device, rather than proving that an AI/software device meets specific performance acceptance criteria through a clinical study.
Therefore, many of the specific details requested in your query (e.g., acceptance criteria for diagnostic algorithm performance, multi-reader multi-case studies, ground truth establishment methods for training sets of AI, sample sizes for AI test/training sets, adjudication methods) are not present in this document because the device in question is an MR coil, not an AI diagnostic software.
However, I can extract information related to the performance testing that was performed to support the substantial equivalence of the MR coil.
Here's what can be gathered from the provided text, with explanations where information is not applicable:
Acceptance Criteria and Device Performance for the dS FootAnkle Coil 8ch 1.5T
This document describes the regulatory submission for an MR coil, not an AI diagnostic software. As such, the "acceptance criteria" and "device performance" are related to the physical and imaging characteristics of the coil, not the diagnostic performance of an AI algorithm. The study described is a demonstration of equivalence and image quality for an MR coil.
1. Table of Acceptance Criteria and Reported Device Performance
The document references two FDA guidance documents for performance criteria:
- "Submission of Premarket Notifications for Magnetic Resonance Diagnostic Devices, issued November 18, 2016" (General MR Device Guidance)
- "Magnetic Resonance (MR) Receive-only Coil – Performance Criteria for Safety and Performance Based Pathway, issued December 11, 2020" (Specific Coil Performance Guidance)
While the specific numerical acceptance criteria from these guidances are not explicitly listed in the 510(k) summary, the document states that the device "met all criterion in the guidance" and that "No new safety or efficacy concerns are raised".
| Acceptance Criteria Category (Implied by Standards/Guidance) | Reported Device Performance |
|---|---|
| Non-Clinical Performance | |
| General electrical/mechanical safety (IEC 60601-1) | Met |
| EMC Immunity, electrostatic discharge (IEC 60601-1-2) | Met |
| Basic safety/essential performance of MR equipment (IEC 60601-2-33) | Met |
| Image uniformity and signal-to-noise ratio (NEMA-MS-1, 3, 9, 14) | Met |
| Determination of essential image quality parameters (IEC62464-1) | Met |
| Biological safety evaluation (ISO 10993-1) | Met |
| Cleaning and disinfection validations (ISO 17664) | Met |
| Clinical Performance (Image Quality for Interpretation) | |
| Images sufficient quality for diagnostic use | Confirmed by experts |
2. Sample Size Used for the Test Set and Data Provenance
- Sample Size: The document does not specify the exact number of cases or images used for the "Clinical Performance" assessment. It only states "Acquired Image quality was assessed..." The extent of this "assessment" (e.g., number of patients/scans reviewed) is not detailed.
- Data Provenance: Not explicitly stated (e.g., specific country, retrospective/prospective). However, the experts used were "U.S. Board Certified radiologists," suggesting data consistent with US clinical practice.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts
- Number of Experts: Two
- Qualifications: "U.S. Board Certified radiologists." No specific years of experience are mentioned.
4. Adjudication Method for the Test Set
- Not applicable/Not described. The assessment was to "confirm images produced on the subject coil are sufficient quality for diagnostic use," implying a qualitative assessment by the two radiologists, rather than a quantifiable "ground truth" establishment requiring adjudication for diagnostic accuracy.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done
- No. This was not an MRMC study comparing human readers with and without AI assistance. It was an assessment of image quality from an MR coil by two readers.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done
- Not Applicable. This is an MR coil, not a standalone algorithm. The performance is inherently linked to the image acquisition process.
7. The Type of Ground Truth Used
- For the "clinical performance," the "ground truth" was the qualitative assessment by two U.S. Board Certified radiologists that the "images produced on the subject coil are sufficient quality for diagnostic use." This is not a diagnostic "ground truth" for disease presence, but rather a performance "ground truth" for image utility.
8. The Sample Size for the Training Set
- Not Applicable. This is an MR coil, not an AI device that undergoes training.
9. How the Ground Truth for the Training Set Was Established
- Not Applicable. As above, this is an MR coil, not an AI device.
Ask a specific question about this device
Page 1 of 48