510(k) Data Aggregation
(28 days)
Ask a specific question about this device
(174 days)
The ZeniCore™ Automatic Biopsy Instrument and optional Co-Axial Introducer Needle is a single-use device indicated for obtaining core samples of soft tissue masses via percutaneous needle biopsy. It is not intended for use in bone.
The ZeniCore™ Automatic Biopsy Instrument and optional, coaxial Introducer needle is a single-use medical device intended for obtaining core soft tissue samples via percutaneous needle biopsy. It is not intended for use in bone lesions. The ZeniCore™ Automatic Biopsy Instrument is a sterile, single patient use device comprised of a spring-loaded biopsy needle fitted into a plastic handle permitting single handed specimen collection than can be used with an optional corresponding coaxial Introducer Needle. The position of the needle may be visualized by imaging techniques such as X-ray, fluoroscopy, and ultrasound. The needle has an echogenic tip with numerically ordered centimeter markings to facilitate precise depth placement. The throw length of the needle when collecting a specimen is 25mm. There are five available needle gauge (G) sizes (12G, 14G, 16G, 18G and 20G) which are identified by a color-coded actuator button. The device is sold either standalone, or as a kit, with an optional, corresponding coaxial needle (cleared under K980004).
The optional Co-Axial Introducer Needle system includes an outer cannula and an inner stylet which terminate in a trocar tip and serves to support acquisition of tissue samples. Each Co-Axial Introducer Needle has an adjustable spring clip that serves as a locking mechanism to secure the position of the outer co-axial needle relative to the skin which ensures the biopsy needle does not accidentally slide forward or backward during the procedure, thereby maintaining the accuracy and safety of the biopsy. The Luer cap of the stylet is color coded to match the corresponding biopsy instrument it is sized to fit.
N/A
Ask a specific question about this device
(109 days)
The EnCor EnCompass™ Breast Biopsy and Tissue Removal System is indicated to acquire breast tissue for histologic examination with partial or complete removal of the abnormality.
The subject device, the EnCor EnCompass™ Breast Biopsy and Tissue Removal System, is a console-based vacuum-assisted breast biopsy device. It is intended to obtain breast tissue samples for diagnostic or histologic analysis and may be used under Ultrasound, Stereotactic, or MR imaging guidance. The system consists of a console, handheld driver, foot switch, biopsy probes, canister liner bags, MRI extension tubing, a stereotactic adapter, MRI introducer sets, and spare sample containers. Replacement parts and components of the console, driver, and foot switch that are also sold separately include a reusable vacuum canister, exhaust filter, driver extension cable, foot switch cable, and power cable.
The EnCor EnCompass™ Breast Biopsy and Tissue Removal System consists of multiple devices that are intended to be used together to obtain breast tissue samples. This includes the EnCor EnCompass™ Console, EnCor EnCompass™ Driver, and EnCor EnCompass™ Foot Switch. The console, driver, and foot switch are designed to provide a user interface and to accept inputs used for specific procedures. The console contains a vacuum system and touchscreen monitor. The driver contains multiple buttons to control procedure functionality and is compatible for use with Ultrasound, Stereotactic, and Magnetic Resonance Imaging (MRI) procedures. The foot switch also contains buttons and a pedal to control procedure functionality and has both wired and wireless connectivity options. They are intended to be used with EnCor EnCompass™ Probes, Canister Liner Bags, MRI Extension Tubing, VisiLoc™ MRI Introducer Sets, and Stereotactic Adapter, which are sold separately. The Probes are the Applied Part of the EnCor EnCompass™ Breast Biopsy and Tissue Removal System.
The EnCor EnCompass™ Probe contains a tubular cutter for tissue acquisition and either a sharp trocar tip at the distal end for insertion or a blunt tip at the distal end for use in areas with sensitive structures. A detachable tissue collection chamber is located on the proximal end of the device. The tissue collection chamber incorporates both a suction line for acquisition and transport of tissue samples and a saline line for optional lavage functionality. A Y-valve luer lock is provided for introducing anesthetic to the biopsy site. Compatible breast tissue markers which are sold and packaged separately may be inserted through the proximal end of the device.
The integrated tubing cassette provides vacuum to an EnCor EnCompass™ Probe during a biopsy procedure.
The EnCor EnCompass™ Probe sample container collects samples as they are acquired and transported during the biopsy procedure. The basket allows for drainage of fluid that is acquired during sampling, vacuuming, and lavaging of the cavity. The basket allows visualization of the samples during and after the procedure and is detachable for sample retrieval post procedure.
The marker adapter allows for marker placement using a marker deployment device through the back of the probe.
The EnCor EnCompass™ Canister Liner Bag collects fluid waste generated during the procedure.
The EnCor EnCompass™ Stereotactic Adapter provides a mechanical interface between the combined EnCor EnCompass™ Driver and EnCor EnCompass™ Probe and the stereotactic biopsy table. The EnCor EnCompass™ Stereotactic Adapter is reusable and affixes directly to the EnCor EnCompass™ Probe with a T-shape fastener and two pins and the EnCor EnCompass™ Driver with rear sliding latches.
N/A
Ask a specific question about this device
(75 days)
Resitu Slider 09 is intended to provide breast tissue for diagnostic analysis of imaged abnormalities.
Resitu Slider 09 (RESL09) is a minimally invasive, vacuum assisted device, intended to provide large intact breast tissue samples for histologic examination of imaged abnormalities. The device is provided sterile and is for single-use. Resitu Slider 09 is hand-held (vacuum is created in the handle) and is part of a monopolar high frequency electrosurgical system.
The intended sample site is reached via a skin incision followed by blunt penetration under ultrasound guidance. The sample capture relies on a combination of vacuum that fixates the sample and cutting with a circular knife. While cutting around the sample area, the vacuum allows the whole tissue sample to enter into the tube of the device. An electrosurgical electrode, designed to mimic a mechanical cutting blade, severs the top base of the breast tissue sample from surrounding area. The device is withdrawn with the intact breast tissue sample inside the tube.
The device functions as an active accessory by passing energy that is controlled by the electrosurgical generator to the tissue, similar to other electrosurgical tools.
The Resitu Slider 09 electrosurgical system consists of the following:
- Active Accessory (Monopolar)
- Electrosurgical Unit
- Active Accessory Cord
- Neutral Electrode
- Neutral Electrode Connection Cord
- Foot Switch (Pedal)
The device consists of a plastic handle, to which a transparent tube with a circular stainless steel knife at the end is attached. Inside the tube is a rod that creates a blunt end when in its outer position. The rod can be pulled back to expose the circular knife and create a vacuum, which will assist in excising the tissue, inside the tube.
In the center of the tube is an electrode, a diathermic knife, which can be pushed forward, backwards, and also turn 360 degrees, thereby enabling a radial cutting from the center.
N/A
Ask a specific question about this device
(207 days)
Disposable Biopsy Needle is intended for use in soft tissue biopsies such as liver, kidney, breast, thyroid, prostate, spleen, pancreas, lymph nodes, lung and various soft tissue tumors. It is not intended for use in bone.
Disposable Biopsy Needle is intended for use in obtaining an aspirate for cytology. Disposable Biopsy Needle has five models: BN-MAR-1, BN-MAR-2, BN-MAR-3, BN-MAR-4, BN-MAR-8. The Disposable Biopsy Needle consists of operating handle of Inner stylet, operating handle of cutting cannula, cutting cannula, inner stylet, depth stopper and protective sheath. The models differ as follows:
- Cutting cannula tip type: The cannula tip type of BN-MAR-1, BN-MAR-2, BN-MAR-3 is chiba. The cannula tip type of BN-MAR-4, BN-MAR-8 is greene.
- Operating handle designs:
- BN-MAR-1, BN-MAR-3, BN-MAR-4 Models:
a. BN-MAR-1, BN-MAR-3, and BN-MAR-4 have the same operating handle, including the operating handle of inner stylet and operating handle of cutting cannula.
b. The Operating handle of Inner stylet connector connects to the Operating handle of cutting cannula connector via a straight snap-fit design, allowing for easy disconnection with one hand to remove the Inner stylet. - BN-MAR-2, BN-MAR-8 Models:
a. The Operating handle of Inner stylet of BN-MAR-2 connects to the Operating handle of cutting cannula via a straight snap-fit design connector, allowing easy disconnection with one hand to remove the Inner stylet.
b. The Operating handle of inner stylet of BN-MAR-8 connects to the Operating handle of cutting cannula via a female Luer taper and male Luer thread taper, which can meet the sealing performances in clinical applications.
- BN-MAR-1, BN-MAR-3, BN-MAR-4 Models:
- Bevel Angle of the Cutting cannula tip: There are three kinds of bevel angle of the Cutting cannula tip, which are α, β, δ. The bevel angle of the cutting cannula tip of BN-MAR-1 and BN-MAR-2 is α. The bevel angle of the needle tip of BN-MAR-3 is β. The bevel angle of the Cutting cannula tip of BN-MAR-4 and BN-MAR-8 is δ.
Each model has various specifications depending on different sizes such as needle lengths, needle diameters, etc. The cutting cannula has numerically ordered centimeter markings on it to provide reference for depth placement. In the distal area of the cutting cannula, an ultrasound enhancement is available to promote accurate placement under ultrasound or X-ray guidance.
An adjustable depth stopper allows the user to restrict forward movement, localizing the needle tip to the biopsy site.
The Operating handle of Inner stylet is color-coded, which indicates gauge size of the needle. It is available in several needle gauge sizes and lengths.
The Disposable Biopsy Needle is a single-use device, supplied in a sterile state sterilized by EO gas. Re-sterilization by users is forbidden. The shelf life is defined for 3 years, which is verified.
The provided document is a 510(k) clearance letter for a Disposable Biopsy Needle. It is a physical device, not an AI/software device. Therefore, the questions regarding acceptance criteria and studies related to AI performance, such as human-in-the-loop, standalone performance, ground truth establishment for training sets, multi-reader multi-case studies, and effect size of AI assistance, are not applicable.
The document discusses non-clinical tests to demonstrate the safety and effectiveness of the device as a physical product.
Here's a breakdown of the relevant information provided:
1. Table of Acceptance Criteria and Reported Device Performance
The document does not present a formal table of acceptance criteria with reported performance values in a side-by-side comparison. Instead, it describes various performance tests conducted. The acceptance criteria are implied by successful completion of these tests as per relevant standards.
| Acceptance Criteria (Implied from Tests) | Reported Device Performance |
|---|---|
| Packaging and Shelf-Life | Met requirements per ASTM F1980; Shelf life defined for 3 years, verified. |
| Biocompatibility | Met requirements per ISO 10993-1, ISO 10993-5, ISO 10993-10, ISO 10993-11, and ISO 10993-23. |
| Sterilization Efficacy | Met requirements per ISO 11135:2014; Device is sterile (sterilized by EO gas). |
| EO Residuals | Met requirements per ISO 10993-7:2008. |
| Physical and Functional Performance (General) | Met requirements for: - Appearance - Basic dimensions - Sample collection space and accessibility - Luer connection - Connection firmness - Stiffness - Toughness - Corrosion resistance - Leakage - Ultrasound detectability - X-ray detectability - Protective sheath - Puncture force - Chemical Characteristics - EO and ECH Residual - Sterility test - Bacterial endotoxin |
| Comparative Performance (Sampling) | No significant difference in sampling weight or cell integrity compared to predicate devices across various tissues (liver, kidney, breast, thyroid, prostate, spleen, pancreas, lymph nodes, lungs). |
2. Sample size used for the test set and the data provenance
The document details testing conducted on the device itself and does not refer to a "test set" in the context of diagnostic data. The tests performed are for physical and functional properties of the biopsy needle.
- Sample size: Not explicitly stated for each test, but standard testing practices involve a sufficient number of samples to ensure representativeness and statistical validity.
- Data provenance: Not applicable in the context of patient data; the data is generated directly from testing manufactured devices.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
Not applicable. This is a physical device. Ground truth refers to diagnostic accuracy in AI/imaging studies.
4. Adjudication method for the test set
Not applicable. Adjudication methods are used to establish ground truth in diagnostic studies, typically involving disagreements between expert readers.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This is a physical device, not an AI-assisted diagnostic tool.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
Not applicable. This is a physical device.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
For the "Comparative study" mentioned in section 4 (Non-Clinical Tests), the ground truth for evaluating sampling performance would inherently be pathology-based assessment of the collected tissue samples (e.g., measuring sampling weight and assessing cell integrity). While not explicitly stated as "ground truth," this is the objective measure used to compare the device's performance against predicates.
8. The sample size for the training set
Not applicable. This is a physical device, not an AI model requiring a training set.
9. How the ground truth for the training set was established
Not applicable. This is a physical device, not an AI model.
Ask a specific question about this device
(266 days)
The Disposable Biopsy Needle is intended for use in obtaining biopsies from soft tissues such as liver, kidney, prostate. It is not intended for use in bone.
The disposable biopsy needle is a sterile, spring loaded, disposable percutaneous soft tissue biopsy instrument. The disposable biopsy needle consists of a cannula, an inner stylet, a mechanical power device and a protective cover. It is used to obtain tissue samples for tissue biopsy, suitable for tissue biopsy of various organs such as the kidney, liver, prostate etc. The needle need to be inserted by a qualified physician under ultrasound guidance. The button of the mechanical power unit comply with the color coding requirements of ISO 6009, i.e. 18 gauge = Pink. The disposable biopsy needle includes three models: CMBNA/1810, CMBNA/1815, CMBNA/1820.
The provided text is a 510(k) clearance letter for a "Disposable Biopsy Needle." It primarily focuses on demonstrating substantial equivalence to a predicate device through non-clinical testing. It does not include information about acceptance criteria, device performance from a clinical study, sample sizes for test/training sets, expert ground truth establishment, adjudication methods, or MRMC studies.
Therefore, many of the requested elements cannot be extracted from this document. However, I can provide what is available, noting where information is absent.
Acceptance Criteria and Device Performance (Based on Non-Clinical Testing)
The document does not explicitly present a table of "acceptance criteria" against which a clinical device performance study was measured. Instead, it details that non-clinical testing was performed to demonstrate substantial equivalence to the predicate device. The performance data provided is primarily related to the physical and material characteristics of the device, rather than diagnostic accuracy or clinical outcomes.
Summary of Reported Performance (Non-Clinical):
| Performance Aspect (Acceptance Criteria Implicitly Met by Testing) | Reported Device Performance (Non-Clinical) |
|---|---|
| Biocompatibility | Complies with ISO 10993-5 (cytotoxicity), -10 (sensitization), -23 (irritation), -11 (systemic toxicity), -4 (blood interactions), ASTM F756-17 (hemolytic properties), USP-NF <151> (pyrogen test). |
| Packaging Verification | Complies with ASTM F1886/F1886M-16 (seal integrity), ASTM F1929-23 (dye penetration), ASTM F88/F88M-2021 (seal strength), DIN 58953-6:2023 (microbial barrier), USP-NF <71> (sterility). |
| Sterilization & Shelf Life | Ethylene oxide sterilization complies with ISO 11135 (process), ISO 10993-7 (ETO residuals), USP-NF <85> (bacterial endotoxins), ANSI AAMI ST72:2019 (bacterial endotoxins), ISO 11737-2 (sterility tests). Shelf life demonstrated for 2 years (compared to 3 years for predicate) through ASTM F1980-21 (accelerated aging), ASTM D4169-23 (shipping stability). |
| Mechanical Performance (Needle Tubing) | Complies with ISO 9626 (stainless steel needle tubing), ISO 7864 (hypodermic needles for single use), ISO 6009 (color coding). |
| Sampling Ability | Samples collected from in vitro porcine liver, porcine kidney, and canine prostate were comparable in mass and quality to those collected using the predicate device. |
| Functional Reliability | Completed 24 repeated sampling steps on in vitro tissues and pork; device fired correctly, and safety lock functioned normally, meeting acceptance criteria (implicitly, for smooth operation). |
| Visibility (Ultrasound) | B-ultrasound image display test report provided to prove visibility. |
Additional Requested Information:
-
Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):
- Sample Size: Not specified for any "test set" in the context of clinical performance. For non-clinical functional testing, "24 repeated sampling steps" were conducted for functional reliability.
- Data Provenance: Not specified for any clinical data. Non-clinical bench testing was conducted.
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):
- Not applicable/Not provided. No clinical test set requiring expert ground truth was described.
-
Adjudication method (e.g. 2+1, 3+1, none) for the test set:
- Not applicable/Not provided. No clinical test set requiring adjudication was described.
-
If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- No MRMC study was mentioned. This device is a biopsy needle, not an AI-powered diagnostic tool.
-
If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
- Not applicable. This is a physical medical device (biopsy needle), not an algorithm.
-
The type of ground truth used (expert consensus, pathology, outcomes data, etc):
- Not applicable for clinical ground truth. For non-clinical sampling verification, the "mass and quality" of collected tissue samples were compared.
-
The sample size for the training set:
- Not applicable/Not provided. This device is a physical instrument, not an AI model requiring a training set.
-
How the ground truth for the training set was established:
- Not applicable/Not provided. This device is a physical instrument, not an AI model requiring a training set.
Ask a specific question about this device
(184 days)
The Marquee™ Disposable Core Biopsy Instrument and Kit are intended for use in obtaining biopsies from soft tissues such as breast, liver, kidney, prostate, spleen, lymph nodes and various soft tissue tumors. It is not intended for use in bone.
The Marquee™ Disposable Core Biopsy Instrument and Instrument Kit is a single use core biopsy device. It is available in several needle gauge sizes and lengths. The coaxial cannula release is color coded according to the various gauge sizes, e.g., yellow = 20 gauge, pink = 18 gauge, purple = 16 gauge, green = 14 gauge, and light blue = 12 gauge.
The Marquee™ Disposable Core Biopsy Instrument is available as a biopsy instrument only and as a kit, which includes the Marquee™ Disposable Core Biopsy Instrument and compatible Disposable Coaxial Biopsy Needle.
The provided FDA 510(k) clearance letter for the Marquee™ Disposable Core Biopsy Instruments and Kits does not contain the detailed acceptance criteria and specific study results traditionally associated with the performance of AI/ML-driven medical devices.
This document is for a physical medical device (biopsy instruments and kits) undergoing a "Special 510(k): Device Modification" clearance. As such, the performance data presented focuses on physical characteristics and material compatibility rather than AI/ML model performance metrics like accuracy, sensitivity, or specificity.
Therefore, I cannot fulfill all parts of your request as the information is not present in the provided text. I will provide a summary based on the information that is available about the device's testing and a table of the acceptance criteria and reported "performance" based on the provided document's context, noting where information is not applicable or not provided.
A. Acceptance Criteria and Reported Device "Performance" (for a physical medical device)
Given that this is a physical biopsy instrument, the "performance" relates to its mechanical and material properties rather than diagnostic accuracy.
| Acceptance Criterion (Category) | Reported Device "Performance" / Test Outcome |
|---|---|
| Biocompatibility | Considered biocompatible for its intended use. |
| Cytotoxicity | Successfully performed |
| Sensitization | Successfully performed |
| Intracutaneous Reactivity | Successfully performed |
| Acute System Toxicity | Successfully performed |
| Material Mediated Pyrogenicity | Successfully performed |
| In Vitro Physical Performance | Evaluated (details of acceptable ranges not provided, but tests were successful) |
| Number of Samples | Performed |
| Penetration Depths | Performed |
| Stylet / Cannula to Handle Tensile Strength | Performed |
| Coaxial Stylet to Hub Tensile Strength | Performed |
| Corresponding Working Needle Length and Cutting Cannula/Coaxial Cannula OD | Performed |
| Safety | Performed |
| Reliability | Performed |
| Integrity of the Sterile Barrier | Performed |
| Performance After Ship Testing | Performed |
| Needle Protection After Shipping and Storage | Performed |
| Shelf Life | Performed |
| Ex-vivo Testing (Tissue Biopsy Quality) | Determined sample quality using 12G, 14G, and 20G models on porcine tissue. (Specific metrics or acceptance thresholds for "sample quality" not detailed in the provided text, but implies satisfactory results for clearance). |
| Substantial Equivalence | Demonstrated to be substantially equivalent to legally marketed predicate devices for the requested indications for use. |
B. Study Details (as inferable from the document for a physical device)
-
Sample sizes used for the test set and the data provenance:
- Sample Size: Not explicitly stated for specific tests (e.g., how many instruments were tested for tensile strength or how many biopsies were taken in ex-vivo tests). The document states "ex-vivo testing was conducted on porcine tissue" using 12G, 14G, and 20G models.
- Data Provenance: The biocompatibility testing followed ISO 10993-1:2018. The ex-vivo testing was done on "porcine tissue." The context suggests these are laboratory-controlled, prospective tests conducted by the manufacturer, Bard Peripheral Vascular, Inc. No country of origin for the data is specified, but typically, these studies are conducted in the country of the manufacturer or approved testing facilities.
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- Not Applicable / Not Provided for this device. For physical devices like biopsy instruments, the "ground truth" is measured against engineering specifications and material properties (e.g., tensile strength, successful sterile barrier). Expert consensus (like in image interpretation) is not directly relevant to these types of performance tests. The ex-vivo tissue quality assessment would likely involve pathologists or relevant subject matter experts, but their number and qualifications are not specified.
-
Adjudication method (e.g., 2+1, 3+1, none) for the test set:
- Not Applicable / Not Provided for this device. Adjudication methods like 2+1 are typically used in clinical studies or studies involving subjective human interpretation (e.g., reading medical images). For the mechanical and material tests described, results are objective measurements against predefined specifications.
-
If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- No. This is not an AI/ML device. An MRMC study is completely irrelevant to this type of medical device (physical biopsy instrument).
-
If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
- No. This is not an AI/ML device. Standalone performance testing refers to the performance of an algorithm without human intervention, which does not apply here.
-
The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
- For Biocompatibility: Compliance with ISO 10993-1:2018 standards and specific test results (cytotoxicity, sensitization, etc.).
- For In Vitro Physical Performance: Engineering specifications, design tolerances, and established industry standards for mechanical properties.
- For Ex-vivo Testing: The "sample quality" on porcine tissue would likely be assessed against histological standards (e.g., tissue integrity, architecture, presence of target cells). Whether this involved expert pathology consensus or objective criteria is not specified, but it would fall under a form of "pathology" ground truth for the sample quality.
-
The sample size for the training set:
- Not applicable. This device is a physical instrument, not an AI/ML model that requires a training set.
-
How the ground truth for the training set was established:
- Not applicable. This device is a physical instrument, not an AI/ML model that requires a training set.
Ask a specific question about this device
(132 days)
The ExpressCore Full Core Biopsy Device is intended for use in obtaining biopsies from soft tissues.
The ExpressCore Device is a sterile, single patient use, hand held full core biopsy device comprised of a plastic handle and three stainless steel needle components that work in sequence to capture a full core biopsy sample. The device is capable of infinitely variable throw distance between 10 and 30mm and is equipped with multiple firing modes to accommodate procedural requirements and physician preference. Multiple device gauge size and needle option combinations have been developed from 12ga x 10cm to 18ga x 25cm.
This FDA 510(k) clearance letter pertains to a device, the ExpressCore Biopsy Device, not an AI/ML software. The provided text details the device's characteristics, intended use, and comparison to predicate devices, but it does not include information about a study that proves the device meets specific acceptance criteria in the context of an AI/ML algorithm.
Therefore, I cannot fulfill your request for:
- A table of acceptance criteria and reported device performance (for an AI/ML algorithm)
- Sample sized used for the test set and data provenance (for an AI/ML algorithm's test set)
- Number of experts used to establish ground truth and qualifications (for an AI/ML algorithm's ground truth)
- Adjudication method (for an AI/ML algorithm's test set)
- MRMC comparative effectiveness study (as this is a physical device, not an AI system assisting human readers)
- Standalone performance (as this is a physical device, not an AI algorithm)
- Type of ground truth used (for an AI/ML algorithm)
- Sample size for the training set (as this is a physical device, not an AI algorithm)
- How the ground truth for the training set was established (as this is a physical device, not an AI algorithm)
The document focuses on the physical and functional characteristics of the biopsy device and demonstrates substantial equivalence to existing predicate devices through bench performance testing, biocompatibility, sterilization, packaging, and shelf life data.
Key information from the provided text relevant to device testing (not AI/ML):
- Type of Study: Non-Clinical Bench Performance Testing, Biocompatibility, Sterilization, Packaging, Shelf Life.
- Purpose of Study: To confirm the device meets all system requirements and is substantially equivalent to the predicate device.
- Specific Tests Mentioned:
- Usability of the Device
- Biopsy Sample Collection
- Finger Cannula Tensile Test
- Spoon Cannula Tensile Test
- Stylet Tensile Test
- Representative Tissue Sampling
This document is a 510(k) clearance for a physical medical device, not a review of an AI/ML-based medical device.
Ask a specific question about this device
(125 days)
The ALARA BMA Neuro Access Kit (ALARA BMAN and ALARA BMAC Kit) is indicated for aspiration of bone marrow or autologous blood.
The ALARA BMA Neuro Access Kit is indicated for pedicle pilot hole preparation, locating, and identifying spinal roots / nerves by providing proximity feedback.
The ALARA BMAC Needle is intended for use in harvesting core biopsy samples of cancellous bone and/or bone marrow.
The ALARA BMA Neuro Access Kit utilizes a neuromonitoring platform in providing the surgeon with nerve / root location feedback during the approach to a pedicle to support a guidewire placement.
The ALARA BMAN and ALARA BMAC Kit includes various single-use needles designed for bone marrow aspiration and aspiration of autologous blood.
This document is an FDA 510(k) clearance letter for a medical device called the "ALARA BMA Neuro Access Kit." This type of document primarily focuses on establishing "substantial equivalence" to predicate devices, rather than presenting detailed study results for a new AI/ML-driven diagnostic device.
Therefore, the provided text does not contain the information requested regarding acceptance criteria and a study proving a device meets these criteria in the context of an AI/ML diagnostic. The "Performance Testing" section lists various engineering and material tests (e.g., torque, pull, strength, sterilization, biocompatibility) relevant to the physical components of the device, not performance metrics for an AI algorithm.
Here's why the requested information cannot be extracted from this document:
- No AI/ML Component: The device description and performance testing sections indicate a physical medical instrument (needles for biopsy, aspiration, and a neuromonitoring platform for "proximity feedback" during pedicle preparation). There is no mention of an AI or machine learning algorithm. The "proximity feedback" is likely an electrical or mechanical system, not an AI interpreting images or data.
- Focus on Substantial Equivalence: A 510(k) clearance is primarily about demonstrating that a new device is "substantially equivalent" to a legally marketed predicate device. This often relies on comparing design, materials, intended use, and non-clinical performance (like the engineering tests listed). It does not typically involve the rigorous clinical efficacy studies or AI performance validation described in your prompt.
- Lack of Diagnostic Claims: The device is for "aspiration of bone marrow or autologous blood," "pedicle pilot hole preparation, locating, and identifying spinal roots / nerves by providing proximity feedback," and "harvesting core biopsy samples." These are procedural/interventional uses, not diagnostic uses that would involve interpreting data (image, signal, etc.) with an AI.
In summary, as the provided document pertains to a physical medical device and not an AI/ML-driven diagnostic, the questions about acceptance criteria for AI performance, sample sizes for test/training sets, expert adjudication, MRMC studies, standalone performance, and ground truth establishment for AI are not applicable to the content provided.
Ask a specific question about this device
(223 days)
The Forsvall biopsy needle is intended to collect histological biopsy samples from soft tissue intended for clinical examination. The Forsvall biopsy needle is part of the Forsvall biopsy needle system for prostate biopsy and shall be used together with the Forsvall biopsy gun.
The Forsvall biopsy gun is intended to be used by medical professionals, together with the Forsvall biopsy needle, on male patients to obtain soft tissue samples. The Forsvall biopsy gun is part of the Forsvall biopsy needle system for prostate biopsy.
The Forsvall biopsy needle system for prostate biopsy is indicated whenever there is a need to obtain prostate biopsy samples.
The Forsvall biopsy needle system for prostate biopsy consists of two items: the Forsvall biopsy needle and the Forsvall biopsy gun. The Forsvall biopsy needle is intended for use with the Forsvall biopsy gun. The Forsvall biopsy gun is reusable and the biopsy needle is single use. The Forsvall biopsy system uses a spring loaded gun that mediates a biopsy needle with a side notch used to obtain tissue samples. The biopsy gun is made of metal and hard plastic and the 16/18 gauge 10/15/20/25 cm biopsy needle is made of stainless medical grade steel.
By pulling a handle on the Forsvall biopsy gun, the front wagon therein is tensioned and connected to the Forsvall biopsy needle. When tensioning the load pin also moves along a guide curve. When the front wagon is in its loaded position, the load pin has moved the front needle bracket a small distance backwards in the Forsvall biopsy gun.
The handle is pulled a second time to tension the rear wagon that is connected to the needle in the Forsvall biopsy needle. A tension is created between the outer tube and the needle in order to force closing of the Forsvall biopsy needle. The purpose is to prevent an interstice from arising in order to prevent accumulation of bacteria.
The Forsvall biopsy gun is fired by pushing the trigger, which causes the rear wagon to move forward of the front wagon. This results in the inner part of the needle being forced forward, followed by forward movement of the outer tube. When the Forsvall biopsy gun is fired, the load pin moves the outer tube the final millimeter in order to achieve a soft closing mechanism. On the Forsvall biopsy needle, the outer tube thus stops against the needle head and it is forced closed.
The Forsvall biopsy operates by the outer tube stopping against the needle head in the closing motion. Additionally, the final millimeter in the closing motion is a soft close action in order to protect the needle head from too strong forces. To enable the soft closing action, the Forsvall biopsy gun has a design similar to the predicate device.
This looks like a 510(k) summary for a medical device called the "Forsvall biopsy needle system for prostate biopsy." Unfortunately, the provided text does not contain the information necessary to answer your questions about acceptance criteria and the study proving the device meets them.
The document focuses on demonstrating substantial equivalence to a predicate device (Möller Medical Biopsy Needles and Systems) based on similar indications for use, technological characteristics, and general safety and performance.
Here's why I cannot provide the requested information from the given text:
- Acceptance Criteria and Device Performance Table: The document lists "Non-Clinical and/or Clinical Tests Summary & Conclusions," but it does not provide specific acceptance criteria (e.g., minimum sample length, specific force measurements) or a table comparing these criteria to the device's reported performance. It only states that "All non-clinical tests related to performance as described above passed."
- Study Details (Sample Size, Data Provenance, Experts, Adjudication, MRMC, Standalone, Ground Truth, Training Set): The document briefly mentions "User Testing" in a "simulated clinical setting" but provides no details about:
- The sample size of this user testing.
- The provenance of any data (e.g., country, retrospective/prospective).
- The number or qualifications of experts.
- Adjudication methods.
- Whether it was an MRMC comparative effectiveness study or a standalone study.
- The type of ground truth used.
- Any training set information.
In summary, the provided FDA 510(k) summary (K242128) does not contain the detailed study information you are asking for regarding acceptance criteria and performance data. It's a regulatory document focused on establishing substantial equivalence, not a detailed scientific study report. Such detailed study information would typically be found in the full 510(k) submission, which is not publicly available in its entirety.
Ask a specific question about this device