510(k) Data Aggregation

    K Number
    K201551

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-09-09

    (92 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The KetoSens BT Blood ß-Ketone Monitoring System is intended for the quantitative measurement of 0-Ketone (betahydroxybutyrate) level in capillary whole blood drawn from the fingertip. The KetoSens BT Blood β-Ketone Monitoring System is intended for self-testing outside the body (in vitro) by people with diabetes at home as an aid to monitor the effectiveness of ketoacidosis control. The system is not intended for use in the diagnosis of or screening for ketoacidosis and is not intended for use on neonates. This system is intended to be used by a single person and should not be shared.

    The KetoSens Blood 0-Ketone Test Strips work with the KetoSens BT Blood 0-Ketone Meter to quantitatively measure Blood ß-Ketone in capillary whole blood samples drawn from the finger.

    Device Description

    Not Found

    AI/ML Overview

    I am sorry, but the provided text does not contain any information about acceptance criteria, device performance, validation studies, sample sizes, ground truth establishment, or expert involvement. The document primarily consists of an FDA 510(k) clearance letter for the KetoSens BT Blood $\beta$ -Ketone Monitoring System, outlining its indications for use and regulatory compliance. Therefore, I cannot fulfill your request to describe the acceptance criteria and the study that proves the device meets them based on the given information.

    Ask a Question

    Ask a specific question about this device

    K Number
    K192957

    Validate with FDA (Live)

    Date Cleared
    2020-06-05

    (228 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VivaChek™ Blood Glucose and ß-Ketone Monitoring System is comprised of the VivaChek™ Blood Glucose and β-Ketone Meter (VGM200), the VivaChek™ Ino Blood Glucose Test Strips (VGS01) and the VivaChek™ Blood β-Ketone Test Strips (VKS01).

    The VivaChek™ Blood Glucose and ß-Ketone Monitoring System is intended to quantitatively measure the glucose concentration and/or (beta-hydroxybutyrate) concentration in fresh capillary whole blood samples drawn from the fingertips. It is intended for use by persons with diabetes at home as an aid to monitor the effectiveness of diabetes control. It is not intended for neonatal use or for the diagnosis of or screening for diabetes. This system is intended for self-testing outside the body (in vitro diagnostic use), and should only be used by a single person and should not be shared.

    Device Description

    VivaChek™ Blood Glucose and β-Ketone Monitoring System (Model: VGM200) is designed to quantitatively measure the glucose and/or ß-ketone concentration respectively in fresh capillary whole blood samples drawn from the fingertips.

    The test principle of the ß-ketone is based on the amperometric detection of ß-hydroxybutyrate (also known as 3-hydroxybutyrate) in whole blood. β-hydroxybutyrate is converted by the enzyme ß-hydroxybutyrate dehydrogenase to acetoacetate. The magnitude of electrical current resulting from this enzymatic reaction is proportional to the amount of ß-hydroxybutyrate present in the sample.

    VivaChek™ Blood Glucose and ß-Ketone Monitoring System (Model: VGM200) contains Bluetooth Low Energy (BLE), it complies with US federal quidelines, Part 15 of the FCC Rules for devices with RF capability.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the VivaChek™ Blood Glucose and ß-Ketone Monitoring System, based on the provided FDA 510(k) summary:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document doesn't explicitly list acceptance criteria values for most studies, but rather states that the studies "Pass" or "were acceptable." For the performance characteristics, it focuses on demonstrating equivalence to the predicate device. For the clinical study, the acceptance criteria were based on participants' ability to obtain readings and satisfaction with ease of operation and overall performance.

    For the B-Ketone performance studies, generally, the acceptance criteria for a blood ketone monitoring system would align with ISO 15197 or similar guidelines, requiring a certain percentage of results to fall within defined accuracy ranges when compared to a reference method (e.g., laboratory analyzer). While not explicitly stated with numerical targets, the "Pass" conclusion for studies like Linearity, Precision, and Interfering Agents implies adherence to such generally accepted analytical performance standards.

    Study TypeAcceptance Criteria (Implied/General)Reported Device Performance (as per document)
    B-Ketone Analytical Performance
    Linearity StudyDemonstrate consistent and accurate measurements across the entire measuring range (0.1 - 8.0 mmol/L)Pass
    Within-Run Precision StudyLow variability in results when testing the same sample multiple times within a single runPass
    Intermediate Precision StudyLow variability in results over time, different operators, and different test strips/reagentsPass
    Hematocrit Effect StudyAccurate measurements across the specified hematocrit range (20-65%)Pass
    Sample Volume StudyAccurate measurements with the specified sample volume (0.8 µL)Pass
    Altitude Effect EvaluationAccurate measurements across relevant altitude variationsPass
    Operating Conditions EvaluationAccurate measurements within specified operating temperature (45.5-113°F) and RH (10-90%)Pass
    Interference Agents StudyAccurate measurements in the presence of common interfering substancesPass
    Stability Studies
    Accelerated Closed Vial Test Strip Stability StudyMaintain performance specifications under accelerated aging conditionsPass
    Accelerated Closed Control Stability StudyMaintain performance specifications under accelerated aging conditionsPass
    Accelerated Open Vial Test Strip Stability StudyMaintain performance specifications under accelerated aging conditionsPass
    Real Time Open Vial Test Strip Stability StudyMaintain performance specifications over the stated shelf-life under real-time conditionsPass
    System and Usability
    User EvaluationNon-professional, inexperienced lay persons able to obtain ß-ketone readings; satisfactory ease of operation and overall performance.Study results indicated that non-professional, inexperienced lay persons were able to obtain ß-ketone readings. Participants were satisfied with ease of operation and overall performance.
    Error Codes TestProper functioning and accurate display of error codesPass
    Meter Environmental Temperature TestMeter functions correctly and accurately within specified environmental temperaturesPass
    Meter Robustness StudyMeter withstands specified physical stresses without performance degradationPass
    Shipping Study (Ketone Strip & Control)Maintain performance specifications after shipping simulationPass
    Meter Software DocumentationSoftware meets specified requirements and documentation is completePass
    Testing with Used Test StripsPrevention of reuse of test strips or proper error indicationPass

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the sample sizes for the individual non-clinical (laboratory) studies. For the User Evaluation (clinical study), it refers to "participated lay persons" without specifying the exact number.

    The provenance of the data is not mentioned in terms of country of origin. The studies are described as "non-clinical (laboratory) studies" and a "clinical (user evaluation) study," indicating they are likely prospective experiments conducted specifically for this submission.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    This information is not provided in the document. For analytical devices like this, ground truth for accuracy studies (e.g., Linearity, Precision) would typically be established by a reference laboratory method using highly accurate and calibrated instruments, not necessarily by experts in the sense of human interpretation.

    4. Adjudication Method for the Test Set

    The document does not describe any adjudication method. Given the nature of a quantitative measurement device, the comparison would typically be against a reference method, rather than requiring expert adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, and its effect size

    No, an MRMC comparative effectiveness study was not done. This type of study is more relevant for diagnostic devices that involve human interpretation of images or other subjective data, which is not the case for a blood ketone and glucose monitoring system.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Yes, the analytical and performance studies listed (e.g., Linearity, Precision, Hematocrit Effect, Interference) represent standalone (algorithm only) performance of the device without human-in-the-loop interpretation beyond operating the device. The device provides a quantitative numerical output directly. The "User Evaluation" did involve humans, but primarily to assess their ability to use the device and obtain a reading, not to interpret the reading itself.

    7. The Type of Ground Truth Used

    For the analytical performance studies (e.g., Linearity, Precision, Hematocrit, Interference), the ground truth would typically be established by a reference laboratory method or highly accurate comparative instrument. The document refers to "corresponding study protocols," which would detail these reference methods, but the specific methods are not described in this summary.

    8. The Sample Size for the Training Set

    The document does not mention a training set or its sample size. This device is not described as using machine learning or AI that would require a distinct training set in the conventional sense. Its performance is based on established electrochemical principles.

    9. How the Ground Truth for the Training Set was Established

    As no training set is mentioned or implied for an AI/ML context, this information is not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K182593

    Validate with FDA (Live)

    Date Cleared
    2018-12-18

    (89 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    KET-1 System: The KET-1 Blood Ketone Monitoring System is intended to quantitatively measure $\beta$ -hydroxybutyrate ( $\beta$ -ketone) in fresh capillary whole blood from fingertips. It should only be used by a single patient and it should not be shared. Testing is done outside the body (In Vitro diagnostic use). It is intended for self-testing by people with diabetes at home as an aid to monitoring the effectiveness of diabetes control programs. It is not to be used for diagnosis or screening of diabetes, or for neonatal use. The KET-1 Blood Ketone Monitoring System is comprised of the KET-1 Blood Ketone Meter and KET-1 Blood Ketone Test Strip.

    Device Description

    The KET-1 Blood Ketone Monitoring System consists of the KET-1 Blood Ketone Meter, KET-1 Blood Ketone Test Strips, and KET-1 Ketone Control Solutions (Level 1 and Level 2). The system is for self-testing of blood ketone. The KET-1 Blood Ketone Test Strips and KET-1 Ketone Control Solutions are purchased separately.

    AI/ML Overview

    This document describes the regulatory approval of the KET-1 Blood Ketone Monitoring System. The provided text is a 510(k) summary, which outlines the device, its intended use, and the studies conducted to demonstrate its substantial equivalence to a legally marketed predicate device.

    Here's an analysis of the acceptance criteria and study proving the device meets them, based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly present a table of numerical acceptance criteria with corresponding performance metrics. Instead, it describes general categories of testing and concludes that the device demonstrates substantial equivalence. For quantitative tests like accuracy, it states that "results demonstrate substantial equivalence to the predicate system" without providing specific numbers or ranges for the acceptance criteria.

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: The document mentions an "accuracy study" conducted with "home users using finger capillary whole blood." However, it does not specify the sample size (number of participants or samples) used for this accuracy study or any other mentioned tests (e.g., precision, repeatability, linearity).
    • Data Provenance: The device manufacturer is Apex Biotechnology Corp. located in Hsinchu, Taiwan. The location of the clinical study (accuracy study) is not explicitly stated, but it is reasonable to infer it would be in Taiwan or a region where the manufacturer operates or has a testing facility. The data provenance is retrospective in the sense that the studies were completed before the 510(k) submission for regulatory review. However, the accuracy study itself was likely conducted prospectively (data collected specifically for the study) from the home users.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This information is not provided in the document. For a blood ketone monitoring system, ground truth would typically be established by a reference laboratory method (e.g., gas chromatography-mass spectrometry or a highly accurate clinical chemistry analyzer) rather than expert human interpretation of images. The document does not specify details of the ground truth method or the personnel involved.

    4. Adjudication method for the test set

    This information is not applicable in the context of a blood ketone monitoring system, as it measures a quantitative analyte. Adjudication methods (e.g., 2+1, 3+1) are typically used for qualitative or diagnostic imaging studies where human experts interpret results and disagreements need to be resolved. For a quantitative measurement, the "ground truth" (reference method result) is directly compared to the device's measurement.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    An MRMC study is not applicable to this device. This type of study is relevant for AI-powered diagnostic imaging devices where human readers (e.g., radiologists) interpret images with and without AI assistance. The KET-1 Blood Ketone Monitoring System is a quantitative point-of-care device that measures a chemical analyte and does not involve human interpretation of complex images or AI assistance for human readers.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    The KET-1 Blood Ketone Monitoring System is a standalone device in the sense that it provides a direct quantitative measurement of β-ketone. Its "performance" is its accuracy and precision in measuring blood ketone levels compared to a reference method, rather than a diagnostic algorithm that processes complex data for human review. The documented testing (accuracy, precision, linearity) essentially assesses the standalone performance of the device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The document implies that the ground truth for the accuracy study was established by a reference method, as is standard for quantitative diagnostic devices. While not explicitly stated, clinical chemistry analyzers or other highly accurate laboratory methods would be used to obtain the "true" β-ketone values against which the KET-1 system's results are compared. It is not expert consensus, pathology, or outcomes data.

    8. The sample size for the training set

    The document does not provide any information about a training set. This is likely because the KET-1 Blood Ketone Monitoring System is a pre-calibrated electrochemical device, not an AI/machine learning model that typically requires a large training dataset. The "training" of such a device usually refers to the internal calibration and manufacturing processes, not the statistical training of a data-driven model.

    9. How the ground truth for the training set was established

    As there is no mention of a training set in the context of an AI/ML model, the establishment of ground truth for a training set is not applicable or described. The device's calibration and internal algorithms would be developed and validated through rigorous engineering and internal testing, using precisely known, manufactured control solutions and spiked samples, rather than a labeled training dataset in the AI sense.

    Ask a Question

    Ask a specific question about this device

    K Number
    K173345

    Validate with FDA (Live)

    Date Cleared
    2018-05-04

    (192 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TD-4140 Smart Dongle Blood Glucose plus [-ketone Monitoring System consists of the Smart Dongle blood glucose test strips, Smart Dongle {}-ketone test strips, and the Procheck mobile application as the display component of the system. This system is intended to be used for the quantitative measurement of glucose (sugar) and fketone in fresh capillary whole blood from the finger.

    This system is intended for self-testing outside the body (in vitro diagnostic use) by people with diabetes at home as an aid to monitor the effectiveness of diabetes control. It is intended to be used by a single person and should not be shared. This system should not be used for the diagnosis of or screening for diabetes, nor for use on neonates.

    Device Description

    The TD-4140 Smart Dongle Blood Glucose plus ß-ketone Monitoring System consists of the Smart Dongle meter, Smart Dongle blood glucose test strips, Smart Dongle 0-ketone test strips, and the Procheck mobile application as the display component of the system.

    This system is compatible to iPhone series, including iPhone 4/4s, 5/5s, 6/6 plus, and iPod touch 5. These products have been designed, tested, and proven to work together as a system to produce accurate test results. The Smart Dongle meter should only be used with the Smart Dongle Blood Glucose test strips and the Smart Dongle ß-ketone test strips.

    AI/ML Overview

    The provided text describes the TD-4140 Smart Dongle Blood Glucose plus ß-ketone Monitoring System, but only offers limited information on specific acceptance criteria for blood glucose and ß-ketone measurements. It reports accuracy and precision performance. The study described is a submission for 510(k) clearance, which typically involves demonstrating substantial equivalence to a predicate device through various performance characteristics, not necessarily a comparative effectiveness study with human readers.

    Here's a breakdown of the available information:

    1. Table of Acceptance Criteria and Reported Device Performance

    Note: The document does not explicitly state "acceptance criteria" but rather presents performance results against implicit standards for glucose and ß-ketone meters. The ranges below are derived from the reported accuracy tables for blood glucose and ß-ketone.

    Measurement ParameterAcceptance Criteria (Implied from Performance Tables)Reported Device Performance
    Blood Glucose
    Accuracy:For glucose < 75 mg/dL: - Within 5 mg/dL (target of 100%) - Within 10 mg/dL (target of 100%) - Within 15 mg/dL (target of 100%)Glucose < 75 mg/dL (N=78): - Within 5 mg/dL: 57 (73.1%) - Within 10 mg/dL: 78 (100%) - Within 15 mg/dL: 78 (100%) Glucose ≥ 75 mg/dL (N=402): - Within 5%: 272 (67.7%) - Within 10%: 386 (96.0%) - Within 15%: 402 (100%) - Within 20%: 402 (100%) (This implies stricter criteria are being met fully)
    For glucose ≥ 75 mg/dL: - Within 5% (target of 100%) - Within 10% (target of 100%) - Within 15% (target of 100%) - Within 20% (target of 100%)Intermediate Precision (Blood Glucose): - Level 1 (49.6 mg/dL): CV 4.38%- Level 2 (139.4 mg/dL): CV 3.13%- Level 3 (335.4 mg/dL): CV 3.01%Repeatability (Blood Samples - Glucose): - Level 1 (49.7 mg/dL): CV 4.39%- Level 2 (91.2 mg/dL): CV 3.23%- Level 3 (128.3 mg/dL): CV 3.16%- Level 4 (227.8 mg/dL): CV 3.15%- Level 5 (390.2 mg/dL): CV 3.09%
    Precision (CV%)(Generally, CV% < 5% for glucose measurements is considered good, but specific criteria are not stated)
    ß-ketone
    Accuracy:For ketone < 2 mmol/L: - Within ±0.3 mmol/L (target of 100%) - Within ±0.5 mmol/L (target of 100%)Ketone < 2 mmol/L (N=89): - Within ±0.3 mmol/L: 84 (94.4%) - Within ±0.5 mmol/L: 89 (100%) Ketone ≥ 2 mmol/L (N=31): - Within 5%: 14 (45.2%) - Within 10%: 26 (83.9%) - Within 15%: 29 (93.5%) - Within 20%: 31 (100%) - Within 25%: 31 (100%) (This implies stricter criteria are being met fully)
    For ketone ≥ 2 mmol/L: - Within 5% (target of 100%) - Within 10% (target of 100%) - Within 15% (target of 100%) - Within 20% (target of 100%) - Within 25% (target of 100%)Repeatability Precision (ß-ketone - Venous Blood): - Level 1 (0.520 mmol/L): CV 10.59%- Level 2 (2.887 mmol/L): CV 3.12%- Level 3 (5.030 mmol/L): CV 3.05%Intermediate Precision (ß-ketone - Control Solution): - Level 1 (0.593 mmol/L): CV 6.15%- Level 2 (2.583 mmol/L): CV 2.71%
    Precision (CV%)(Generally, CV% < 10% for ketone measurements is often a benchmark, but specific criteria are not stated)

    2. Sample Sizes Used for the Test Set and Data Provenance

    • Blood Glucose Accuracy:
      • For glucose < 75 mg/dL: N = 78
      • For glucose ≥ 75 mg/dL: N = 402
      • Total N for glucose accuracy: 480
    • ß-ketone Accuracy: N = 120 (capillary blood sampling subjects)
      • Ketone < 2 mmol/L: N = 89
      • Ketone ≥ 2 mmol/L: N = 31
    • Precision Tests (Glucose & ß-ketone): The document doesn't specify the exact number of samples or subjects for precision tests, only the "levels" of control solutions/blood samples tested.
    • Data Provenance: Not specified. The document states the applicant company is in Taiwan, but it does not specify the country of origin for the clinical study data or whether it was retrospective or prospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Not specified. The document describes electrochemical biosensor technology being used, and the "ground truth" for glucose and ß-ketone measurements would typically be established by a reference laboratory method (e.g., YSI for glucose, or a high-performance liquid chromatography (HPLC) method for ketones), not by human experts for this type of quantitative measurement.

    4. Adjudication Method

    Not applicable. For quantitative measurements by a device, ground truth is typically established by laboratory reference methods, not by expert adjudication.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No. This document does not mention an MRMC comparative effectiveness study. This type of study is more common for diagnostic imaging or interpretation tasks, not for quantitative blood glucose and ß-ketone monitoring systems. The study presented focuses on the device's standalone analytical performance and substantially equivalence to a predicate device.

    6. Standalone Performance

    Yes, the studies reported are standalone performance studies of the algorithm/device. The tables provided show the accuracy and precision of the TD-4140 Smart Dongle Blood Glucose plus ß-ketone Monitoring System relative to reference measurements, without human intervention in the measurement process. The mobile application acts as a display component, but the core measurement and algorithmic analysis for glucose and ß-ketone are intrinsic to the dongle and test strips.

    7. Type of Ground Truth Used

    The ground truth for both glucose and ß-ketone measurements is implied to be based on laboratory reference methods. The document states, "The test strip is calibrated to display the equivalent of plasma glucose values to allow comparison of results with laboratory methods," strongly suggesting that such methods were used as the gold standard for comparison in accuracy studies.

    8. Sample Size for the Training Set

    Not specified. The document focuses on performance studies for regulatory submission (510(k)) and does not detail the internal development and training of any algorithms within the device. For electrochemical biosensors, "training" might refer to the calibration of the strips and meter rather than machine learning algorithm training.

    9. How the Ground Truth for the Training Set Was Established

    Not specified. As mentioned above, the concept of a "training set" and "ground truth establishment" in the context of machine learning is not explicitly addressed in this document. If algorithmic calibration was involved, it would likely use well-characterized reference solutions and laboratory methods, similar to the ground truth used for validation.

    Ask a Question

    Ask a specific question about this device

    K Number
    K170463

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2018-04-13

    (422 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    KetoSens Blood ß-Ketone Monitoring System is intended to be used for the quantitative measurement of f-Ketone (beta-hydroxybutyrate) level in capillary whole blood samples drawn from the fingertip. The KetoSens Blood B-Ketone Monitoring Systems are for self-testing outside the body (for in vitro diagnostic use) in the home as an aid to monitor the effectiveness of diabetes control program. The system is not in the diagnosis of or screening for diabetes mellitus and is not intended for use on neonates. This system is intended to be used by a single person and should not be shared.

    The KetoSens Blood ß-Ketone Test Strips work with the KetoSens Blood ß-Ketone Meter to quantitatively measure Blood ß-Ketone in capillary whole blood samples drawn from the fingertip.

    KetoSens Multi Blood p-Ketone Monitoring System is intended to be used for the quantitative measurement of f-Ketone (beta-hydroxybutyrate) level in capillary whole blood from the fingertip and venous EDTA whole blood. KetoSens Multi Blood ß-Ketone Monitoring System is intended for in vitro diagnostic use and is intended for multiple-patient use in professional healthcare settings as an aid to monitor the effectiveness of diabetes control program. The system is not intended for use in the diagnosis of or screening for diabetes mellitus and is not intended for use on neonates. This system should only be used with single-use, auto-disabling lancing devices.

    The KetoSens Multi Blood p-Ketone Test Strips work with Blood ß-Ketone Meter to quantitatively measure Blood B-Ketone in capillary whole blood samples drawn from the fingertip and venous whole blood drawn in professional healthcare settings.

    Device Description

    The KetoSens Blood ß-Ketone Monitoring System/KetoSens Multi Blood ß-Ketone Monitoring System consists of a meter, single use test strips, and control solutions with two different B-Ketone concentrations ("Control A" and "Control B" ranges).

    The KetoSens Blood ß-Ketone Monitoring System/KetoSens Multi Blood ß-Ketone Monitoring System is based on an electrochemical biosensor technology (electrochemical). The System measures the Blood ß-Ketone level in whole blood samples using a small electrical current generated in the test strips.

    AI/ML Overview

    This document focuses on the KetoSens Blood β-Ketone Monitoring System and its validation studies. It describes various performance tests conducted to ensure the device meets specified criteria, primarily focusing on accuracy, precision, and usability.

    Here's an organized breakdown of the acceptance criteria and study details based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a single table labeled "Acceptance Criteria." However, acceptance criteria are implicitly stated within the "System Accuracy Test" and "Consumer Study" results, and "Repeatability Test" and "Intermediate Precision Test" conclusions.

    Test TypeAcceptance Criteria (Stated or Implied)Reported Device Performance
    Repeatability (Precision)Pooled SD of concentrations 1, 2 should be < 0.075 mmol/L. Pooled CV % of concentrations 3, 4, 5 should be < 5.0 %.Passed. Pooled SD (concentration 1) = 0.027 mmol/L, (concentration 2) = 0.056 mmol/L. Pooled CV % (concentration 3) = 3.7%, (concentration 4) = 3.5%, (concentration 5) = 3.6%.
    Intermediate PrecisionPooled SD for concentration interval 1 < 0.075 mmol/L. Pooled CV % for interval 2, 3 < 5.0 %.Passed. Pooled SD (concentration 1) = 0.049 mmol/L. Pooled CV % (concentration 2) = 3.8%, (concentration 3) = 4.3%.
    LinearityHigh linear correlation (coefficient of determination r² > 0.95).Passed. Total r² = 0.9985 across 3 strip lots.
    System Accuracy (Capillary Blood)At ketone < 1.5 mmol/L: 95% of results within ± 0.3 mmol/L. At ketone ≥ 1.5 mmol/L: 95% of results within ± 20 %.Passed.> At ketone < 1.5 mmol/L: 170/171 (99.4%) within ± 0.3 mmol/L.> At ketone ≥ 1.5 mmol/L: 33/33 (100%) within ± 20 %. All 204 samples (100%) fell within specified ranges.
    System Accuracy (Venous Blood)At ketone < 1.5 mmol/L: 95% of results within ± 0.3 mmol/L. At ketone ≥ 1.5 mmol/L: 95% of results within ± 20 %.Passed.> At ketone < 1.5 mmol/L: 169/169 (100%) within ± 0.3 mmol/L.> At ketone ≥ 1.5 mmol/L: 35/35 (100%) within ± 20 %. All 204 samples (100%) fell within specified ranges.
    Consumer Study (Accuracy)Capillary blood accuracy to satisfy system accuracy requirements (as defined above).Passed.> General user tests: 185/185 (100%) within ± 0.3 mmol/L (for ketone < 1.5 mmol/L - implicitly applies given all results fell within).> Trained user tests: 185/185 (100%) within ± 0.3 mmol/L (for ketone < 1.5 mmol/L - implicitly applies). Also, 100% of general users could use the device correctly and obtain accurate results.
    Point-of-Care (POC) Test (Accuracy)Accuracy requirements met (as defined for system accuracy).Passed.> Capillary: 124/124 (100%) within ± 0.3 mmol/L for < 1.5 mmol/L; 12/12 (100%) within ± 20% for ≥ 1.5 mmol/L.> Venous: 121/123 (98.4%) within ± 0.3 mmol/L for < 1.5 mmol/L; 13/13 (100%) within ± 20% for ≥ 1.5 mmol/L.
    Hematocrit EffectHematocrit biases to be within acceptable limits (specific thresholds are detailed in the results section, generally showing low bias).Passed. Biases were within specified ranges for different ketone intervals across 20-60% hematocrit. For example, -0.09 to 0.02 mmol/L at 0.0-0.8 mmol/L ketone, and percentage biases for higher concentrations (e.g., -15.02 to 8.73% at 5.5-6.5 mmol/L ketone).
    Interference TestNo significant interference from listed substances. (Implicitly, results should not show significant bias).Passed. Differences observed are mostly small, suggesting acceptable performance in the presence of various interferents. For example, Acetaminophen showed a -5.4% to -8.3% difference in the 2.0-3.5 mmol/L range, while many others were much smaller. Specific acceptance thresholds for interference are not explicitly provided in the summary, but the conclusion implies acceptance.
    Altitude TestNo significant difference from reference equipment at high altitudes (up to 10,000 feet).Passed. No systematic response to altitudes; not significantly affected by lack of atmospheric oxygen up to 10,000 feet (3,048m).
    Operating Condition TestMeters operate normally with less than 0.03 mmol/L or 20% bias from reference results.Passed. Confirmed normal operation at 9 combined temperature-humidity conditions (10°C, 15°C, 30°, 40%, and 90% RH), with results showing bias less than 0.03 mmol/L or 20% from reference.

    2. Sample Size Used for the Test Set and Data Provenance

    • System Accuracy Test (Capillary Blood): 204 samples.
    • System Accuracy Test (Venous Blood): 204 samples.
    • Repeatability Test: 300 measurements (N=300 for each of 5 concentration levels). This suggests a large number of readings rather than 300 unique samples.
    • Intermediate Precision Test: 600 measurements (N=600 for each of 3 control levels).
    • Consumer Study: 185 general users.
    • Point-of-Care Test: 124 patients for capillary samples, 123 patients for venous samples.
    • Hematocrit Effect Test: 5 different hematocrit levels, 5 different ketone intervals, measured using 30 meters and 3 lots of strips.
    • Interference Test: 2 ketone concentrations, across 29 interferents, with 3 strip lots.
    • Altitude Test: Not specified in terms of distinct sample numbers, but tested.
    • Operating Condition Test: Not specified in terms of distinct sample numbers, but tested.

    Data Provenance: The document does not explicitly state the country of origin of the data or whether the studies were retrospective or prospective. However, based on the nature of clinical evaluation, consumer studies, and POC tests involving patient samples and human participants, these are typically prospective studies. The company, i-SENS, Inc., is based in Seoul, Korea, suggesting the studies likely took place there or in a similar regulatory environment.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    • The document mentions "trained staff" and "Health Care Professionals" (HCPs) in the context of comparative measurements.
    • In the Consumer Study, results of general users are compared against "Rx Imola reference values" and "BKMS results obtained by trained staff."
    • In the Point-of-Care Test, "Health care professionals" (six members) performed tests, and "The study staff operates the reference equipment and modify the KetoSens Multi BKMS results are compared against the reference values."
    • The qualifications of these "trained staff" or "Health Care Professionals" are not explicitly defined (e.g., "radiologist with 10 years of experience"). Their role is to operate the reference equipment and/or the candidate device for comparison.

    4. Adjudication Method (e.g. 2+1, 3+1, none) for the Test Set

    The document does not describe an adjudication method for the test set in the context of expert review or consensus, as would be typical for image-based diagnostic AI. For a quantitative measurement device, the "ground truth" is typically established by comparative measurement to a highly accurate reference method. Discrepancies are usually managed through statistical analysis rather than an adjudication process among human readers.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    This is not applicable as the device is a quantitative blood β-ketone monitoring system, not an AI-based diagnostic imaging tool that assists human readers. Therefore, an MRMC study and analysis of human reader improvement with AI assistance are not relevant to this device.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) Was Done

    The device is a standalone quantitative measurement system. Its performance (accuracy, precision) is evaluated independently against a reference standard (Rx Imola equipment). The human user's role is to operate the device correctly, consistent with its "intended to be used for the quantitative measurement" function. The consumer study and POC test assess the usability for target users (self-testing or HCPs), but the core performance data in the system accuracy tests represent the device's measurement capabilities.

    7. The Type of Ground Truth Used (Expert Consensus, Pathology, Outcomes Data, etc.)

    The ground truth for the quantitative measurement of β-ketone levels was established using a reference measurement procedure/equipment. Specifically:

    • "The accuracy of KetoSens is evaluated with clinical evaluation using capillary and venous blood samples... and with the standard measurement."
    • "KetoSens BKMS did not show significant difference with respect to the Rx Imola equipment, nor with different altitudes at all ketone concentrations."
    • In the Consumer Study and POC test, results were compared against "Rx Imola reference values."

    Therefore, the ground truth is comparative measurement to a recognized laboratory reference method/instrument (Rx Imola).

    8. The Sample Size for the Training Set

    The document describes performance evaluation (test set) studies but does not mention a 'training set' in the context of machine learning model development. This is because the KetoSens Blood β-Ketone Monitoring System is based on electrochemical biosensor technology, which relies on a chemical reaction to produce an electrical current proportional to the analyte, rather than an AI/ML algorithm that requires training data.

    9. How the Ground Truth for the Training Set Was Established

    As the device does not employ an AI/ML algorithm requiring a 'training set,' this question is not applicable. The underlying principle is electrochemical, not data-driven machine learning.

    Ask a Question

    Ask a specific question about this device

    K Number
    K170587

    Validate with FDA (Live)

    Date Cleared
    2017-07-06

    (128 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Healthy Me™ Ketone Reagent Strips for Urinalysis are intended for the qualitative and semi-quantitative detection of Ketone (Acetoacetic acid) in urine. The identification of ketones is used in the diagnosis of acidosis (a condition characterized by abnormally high acidity of body fluids) or ketosis (a condition characterized by increased production of ketone bodies such as acetone) and for monitoring patients on ketogenic diets.

    The Healthy Me™ Ketone Reagent strips are intended for Over the Counter use by lay people with Diabetes and/or people on low carb diets at home to check for the ketones in urine. This product is not intended for the management of diabetes.

    The On Call Ketone Reagent Strips for Urinalysis are intended for the qualitative and semi-quantitative detection of Ketone (Acetoacetic acid) in urine. The identification of ketones is used in the diagnosis of acidosis (a condition characterized by abnormally high acidity of body fluids) or ketosis (a condition characterized by increased production of ketone bodies such as acetone) and for monitoring patients on ketogenic diets.

    The On Call Ketone Reagent strips are intended for Over the Counter use by lay people with Diabetes and/or people on low carb diets at home to check for the ketones in urine. This product is not intended for the management of diabetes.

    Device Description

    On Call® & Healthy Me" Ketone Reagent Strips for Urinalysis consists of a Plastic Strip to which a regent pad is affixed. The reagent pad reacts with the urine and provides a visible color reaction. On Call® & Healthy Me™ Ketone Reagent Strips for Urinalysis are packaged along with a drying agent in a Canister bottle. Each strip is stable and ready to use upon removal from the Canister. The entire reagent strip is disposable. Results are obtained by direct comparison to the test strip with a color blocks printed on the bottle label. Accurate timing is essential to provide optimal results. No calculations or laboratory instruments are needed.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the On Call/Healthy Me Ketone Reagent Strips for Urinalysis:

    Introduction to the Device
    The device, On Call® & Healthy Me™ Ketone Reagent Strips for Urinalysis, is intended for the qualitative and semi-quantitative detection of acetoacetic acid (ketones) in urine. It's designed for over-the-counter use by laypersons, including those with diabetes or on low-carb diets, to monitor for ketones at home. The test is based on a color change reaction with nitroprusside and acetoacetic acid, ranging from light pink (negative) to darker pink/purple (positive).

    Acceptance Criteria and Device Performance

    Acceptance Criteria CategorySpecific Criteria (if stated or inferred)Reported Device Performance
    Method Comparison AgreementAccuracy against Predicate Device (Technician read) using Solution Concentrations:- Same block agreement: High agreement across all color blocks.- Agreement within +/- one block: Very high agreement across all color blocks.1. Results of ACON Ketone by Layperson vs Bayer Ketostix by Technician at 3 Sites with solution concentrations matching color blocks:- Same block agreement: 99.4% (ranging from 55/56 for 15 mg/dL to 60/60 for Neg, 5mg/dL, 40mg/dL, and 61/61 for 160mg/dL, and 60/61 for 80mg/dL).- Agreement within +/- one block: 100.0%.
    User Performance AgreementAccuracy against Predicate Device (Technician read) using Participant Midstream Urine:- Same block agreement: High agreement across all color blocks where predicate showed results.- Agreement within +/- one block: Very high agreement across all color blocks where predicate showed results.2. Participants' Midstream Urine with ACON Ketone Reagent Strips by Layperson vs Urine Collected in Cup with Bayer Ketostix by Technician at 2 sites:- Same block agreement: 100% for observable results where data is provided (Neg, 5 mg/dL, 15 mg/dL, 40 mg/dL). Note: No results reported for 80 mg/dL or 160 mg/dL when read by layperson with ACON, while technician with Bayer showed 0 for these too. This suggests either these levels were not present in midstream urine or were not detected by either device/method.
    Substantial EquivalenceDemonstrate substantial equivalence to the predicate device (Bayer Ketostix reagent strips K801270) in terms of intended use, principle, reagents, specimen, methodology, and performance.The conclusion explicitly states: "The above mentioned results demonstrate that the On Call and Healthy Me Ketone reagent strips for urinalysis are substantially equivalent to legally marketed predicate device currently sold on the U.S. market."
    Analytical PerformanceReference to prior 510(k) (K061559) for ACON Urinalysis Reagent Strips."The performance of Ketone reagent strips has been evaluated and present in 510k- K061559-ACON Urinalysis Reagent Strips." (The specific acceptance criteria from K061559 are not detailed here, but the statement implies they were met).
    Clinical Sensitivity/SpecificityNot applicable; assumed to be covered by the method comparison and substantial equivalence to a predicate for which these were established.Not Applicable.

    Study Details

    1. Sample Size used for the test set and the data provenance:

      • Study 1 (Solutions): 347 samples. These were solution concentrations designed to match the color blocks. The provenance is not explicitly stated beyond being conducted at "3 Sites." It's likely a controlled laboratory study rather than patient samples.
      • Study 2 (Midstream Urine): 71 samples. These were "Participants' Midstream Urine." The provenance is not explicitly stated beyond being conducted at "2 sites." It's likely prospective collection for the purpose of the study.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Ground truth was established by a "Technician" reading the predicate device (Bayer Ketostix).
      • The number of technicians is not specified.
      • Their qualifications are not specified (e.g., years of experience, specific certifications), other than being identified as "Technician."
    3. Adjudication method for the test set:

      • The document implies that the technician's reading of the predicate device was taken as the reference standard (ground truth). There is no mention of a
        multi-reader adjudication method (e.g., 2+1, 3+1) for establishing this ground truth.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • This was not an MRMC study comparing human readers with and without AI assistance. This study compared a layperson reading the investigational device against a technician reading a predicate device.
      • Therefore, no effect size related to AI assistance for human readers is applicable or provided.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • No, this device is a manual reagent strip read by a human (layperson). It does not involve an algorithm or AI.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • The ground truth was established by a "Technician" reading the predicate device (Bayer Ketostix) and comparing the color change to the color blocks. This is a form of reference standard comparison to a legally marketed predicate device, where the predicate read by a trained professional serves as the benchmark. For the first study, it was confirmed against known solution concentrations.
    7. The sample size for the training set:

      • The document does not explicitly state a separate "training set" for the current device. The performance evaluation presented is for the validation/test set. It mentions that "The performance of Ketone reagent strips has been evaluated and present in 510k- K061559-ACON Urinalysis Reagent Strips," implying a prior validation for a professional version of the device, which would have had its own training/test data.
    8. How the ground truth for the training set was established:

      • Since a training set for this specific submission is not specified, how its ground truth was established is not detailed in this document. For the predicate device (Bayer Ketostix) and the previously cleared professional device (K061559), the ground truth would have likely been established through reference laboratory methods (e.g., spectrophotometry, enzymatic assays) for quantitative ketone levels, which are then correlated with the semi-quantitative color scale.
    Ask a Question

    Ask a specific question about this device

    K Number
    K060768

    Validate with FDA (Live)

    Date Cleared
    2006-04-21

    (30 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Precision Xtra / Optium Blood ß-Ketone Test Strips are intended to quantitatively measure blood ß-Ketone (Beta-Hydroxybutyrate) in fresh capillary whole blood from the fingertip. The test strips are for use outside the body (in vitro diagnostic use) and are for self-testing or healthcare professional use. Healthcare professionals may also use venous whole blood samples, provided the samples are used within 30 minutes of collection. The test strip is to be used for ketone concentrations in persons with diabetes and other conditions.

    Device Description

    The Precision® Xtra™ Diabetes Monitoring System utilizes amperometric biosensor technology to generate a current. The size of the current is proportional to the amount of ß-hydroxybutyrate (ß-ketone) present in the sample, providing a quantitative measure of ß-ketone in whole blood and control solutions.

    AI/ML Overview

    The Abbott Precision Xtra Blood ß-Ketone Test Strips and Optium Blood ß-Ketone Test Strips are intended for the quantitative measurement of ß-ketone (Beta-Hydroxybutyrate) in fresh capillary whole blood and, for healthcare professionals, in venous whole blood samples within 30 minutes of collection. The device is for in vitro diagnostic use, for self-testing or professional use by individuals with diabetes and other conditions requiring ketone monitoring.

    A study was conducted to demonstrate the substantial equivalence of the Precision Xtra Blood ß-Ketone Test Strips/Optium Blood ß-Ketone Test Strips to predicate devices (Precision Xtra Blood ß-Ketone Test Strips K983504 and Optium Blood ß-Ketone Test Strips K040814/K050814).

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document mentions that various performance aspects were tested and passed, indicating they met established acceptance criteria, but it does not specify the numerical criteria themselves or the exact reported performance values. The performance studies verified the device through "non clinical testing in the laboratory."

    Performance CharacteristicAcceptance Criteria (Implied: Passed)Reported Device Performance (Implied: Acceptable/Comparable)
    AltitudeMet predefined specificationsVerified as acceptable
    Dynamic RangeMet predefined specificationsVerified as acceptable
    PrecisionMet predefined specificationsVerified as acceptable
    LinearityMet predefined specificationsVerified as acceptable
    AccuracyMet predefined specificationsVerified as acceptable
    Sample VolumeMet predefined specificationsVerified as acceptable
    InterferenceMet predefined specificationsVerified as acceptable
    Sensor MovementMet predefined specificationsVerified as acceptable
    Oxygen SensitivityMet predefined specificationsVerified as acceptable
    Sample Application (end/top fill)Met predefined specificationsVerified as acceptable
    Environmental (e.g., temperature/humidity)Met predefined specificationsVerified as acceptable
    HematocritMet predefined specificationsVerified as acceptable
    pHMet predefined specificationsVerified as acceptable
    ShippingMet predefined specificationsVerified as acceptable

    2. Sample Size Used for the Test Set and Data Provenance:

    The document does not explicitly state the sample sizes used for the non-clinical laboratory testing. The data provenance is stated as "non clinical testing in the laboratory," implying controlled laboratory conditions rather than patient data from a specific country. It is not specified whether the data was retrospective or prospective.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications:

    This information is not provided in the document. Given that the testing was "non clinical" and involved laboratory studies, it is unlikely that human experts were involved in establishing ground truth in the way described for clinical studies (e.g., radiologists interpreting images). Ground truth for these types of devices is typically established using a reference method or calibrated laboratory equipment.

    4. Adjudication Method for the Test Set:

    Not applicable, as this was non-clinical laboratory testing, not a clinical study involving human interpretation.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

    No, an MRMC comparative effectiveness study was not done. The performance studies were non-clinical laboratory tests comparing the device to its predicate devices, not evaluating human reader improvement with or without AI assistance.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done:

    Yes, a standalone performance assessment was effectively done. The performance studies described are for the device (test strips) itself, evaluating its accuracy, precision, and other analytical characteristics in a laboratory setting, without direct human intervention in the result generation process beyond using the device as intended. The "algorithm" here would be the electrochemical reaction and measurement system of the biosensor technology.

    7. The Type of Ground Truth Used:

    The document does not explicitly state the type of ground truth. However, for "non clinical testing in the laboratory" of a quantitative measurement device, the ground truth would typically be established using:

    • Reference methods: Highly accurate and precise laboratory methods (e.g., enzymatic reference methods for ß-ketone).
    • Calibrated standards: Solutions with known, precise concentrations of ß-ketone.

    8. The Sample Size for the Training Set:

    The document does not contain information about a "training set." The mentioned studies are performance verification for the device, implying that the device's design and underlying technology were already established. For this type of in vitro diagnostic device, "training sets" are not typically used in the same manner as for machine learning algorithms.

    9. How the Ground Truth for the Training Set Was Established:

    Not applicable, as no training set is mentioned or implied for this non-clinical performance verification.

    Ask a Question

    Ask a specific question about this device

    K Number
    K033114

    Validate with FDA (Live)

    Device Name
    KETOCHECKS
    Date Cleared
    2004-04-26

    (209 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Neo Diagnostics KetoChecks is intended for the identification of ketones in urine and can be used in the diagnosis of acidosis (a condition characterized by abnormally high acidity of body fluids) or ketosis (a condition characterized by increased production of ketone bodies such as Acetoacetic acid) and for monitoring patients on ketogenic diets and patients with diabetes. The test is indicated for use by professionals and for Over the Counter use by lay people.

    Device Description

    KetoChecks for Urinalysis is firm plastic strips to which a reagent area is affixed. Depending on the product being used, KetoChecks provides a test for Ketone (Acetoacetic acid) in Urine. Test results may provide information regarding the status of carbohydrate metabolism. Please refer to the outside box and bottle label for the specific test parameters of the product you are using.

    KetoChecks is packaged along with a drying agent in a plastic bottle with a twist-off cap. Each strip is stable and ready to use upon removal from the bottle. The entire reagent strip is disposable. The directions must be followed exactly. Results are obtained by direct comparison of the test strip with the color blocks printed on the bottle label. Accurate timing is essential to provide optimal results. To obtain optimal results, it is necessary to use fresh, well-mixed, and uncentrifuged urine. No calculations or laboratory instruments are needed.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and the study proving the device meets them, based on the provided text for K033114:

    Acceptance Criteria and Device Performance

    The provided document defines accuracy based on the comparison of the KetoChecks strips to a color chart, which is itself determined by the color blocks on the bottle label. The closest thing to explicit "acceptance criteria" for performance is within the clinical correlation study, where the device (KetoChecks) is compared against a legally marketed predicate device (Bayer Ketostix).

    Table of Acceptance Criteria and Reported Device Performance

    Performance MetricAcceptance Criteria (Implied by Predicate Equivalence)Reported Device Performance (KetoChecks Lot 1 vs. Bayer Ketostix Lot 3A04A)
    Agreement with predicate (Same Color Block)High agreement with predicate device97.2% (212/218)
    Agreement with predicate (Within 1 Color Block)Very high agreement with predicate device99.5% (217/218)
    Internal Consistency (Same Color Block for different lots)High consistency between different lots97.1% (134/138)
    Internal Consistency (Within 1 Color Block for different lots)Very high consistency between different lots99.3% (137/138)

    Note: The document explicitly states: "For visually read strips, accuracy is a function of the manner in which the color blocks on the bottle label are determined and the discrimination of the human eye in reading the test. Precision is difficult to assess in a test of this type because of the variability of the human eye. It is for this reason that users are encouraged to develop their own standards of performance." This implies that the primary acceptance criteria revolve around the device's ability to produce consistent results with its own color chart and to perform comparably to a well-established predicate device.

    Study Details

    The study presented focuses on establishing substantial equivalence to the Bayer Ketostix reagent strips.

    1. Sample Size Used for the Test Set and Data Provenance:

      • Test Set Sample Size:
        • For the comparison of KetoChecks Lot 1 vs. Bayer Ketostix Lot 3A04A: 218 unknown urine samples were used.
        • For the comparison of KetoChecks Lot 1 vs. KetoChecks Lot 2 (internal consistency): 138 unknown urine samples were used.
      • Data Provenance: The document does not specify the country of origin. It indicates that "clinical tests" were performed, suggesting prospective collection of urine samples for the purpose of this evaluation. However, details on ethical approvals or patient demographics are not provided.
    2. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

      • The document implies that the ground truth for the comparison was based on the visual readings of the KetoChecks strips and the Bayer Ketostix strips themselves. It does not mention an independent "ground truth" established by a panel of experts in the traditional sense, such as pathology or a gold standard instrument.
      • For visually read strips, the document states, "Comparison to the color chart is dependent on the interpretation of the individual. It is, therefore, recommended that all laboratory personnel interpreting the results of these strips be tested for color blindness." This suggests that the "experts" are the "laboratory personnel" performing the visual comparisons, but their number and specific qualifications (e.g., years of experience as a lab technician) are not detailed.
    3. Adjudication Method for the Test Set:

      • No explicit adjudication method (like 2+1 or 3+1) is described. The results are presented as direct comparisons (e.g., "Same Color Block," "Within 1 Color Block"). It appears that the reading itself is the primary data point, and there's no mention of a process to resolve discrepancies between multiple readers, if multiple readers were used.
    4. Multi Reader Multi Case (MRMC) Comparative Effectiveness Study:

      • No, a formal MRMC comparative effectiveness study, as typically understood in the context of advanced AI devices, was not performed. The study is a comparison of two visual dipstick products, focused on agreement between the new device and the predicate device, not on how human readers' performance with or without AI-assistance improves clinical outcomes or accuracy compared to a true gold standard.
    5. Standalone Performance:

      • Yes, a standalone performance evaluation was done in the sense that the KetoChecks device was read visually by an individual and compared against the color chart provided with the device and also against the results obtained from the predicate device. It represents the inherent performance of the device and a human reader in tandem, without assistance from an AI algorithm. The device itself is solely a visual reagent test strip, so its "standalone" performance is its direct visual interpretability.
    6. Type of Ground Truth Used:

      • The primary "ground truth" for evaluating the KetoChecks' performance relative to the predicate was agreement with the Bayer Ketostix results. For internal consistency, the ground truth was the visual reading of the KetoChecks strip itself by the "individual" (presumably lab personnel). There is no mention of pathology, advanced laboratory instrumentation, or long-term clinical outcomes data being used as ground truth. This is typical for equivalence claims for simple diagnostic strips.
    7. Sample Size for the Training Set:

      • This question is not applicable in the context of this device and study. The KetoChecks is a chemical reagent strip for visual interpretation, not a machine learning or AI-based device that requires a "training set" of data in the computational sense. The "training" for such a device would involve optimizing the chemical reagents and color chart design.
    8. How the Ground Truth for the Training Set Was Established:

      • This question is not applicable for the same reasons as point 7. The "ground truth" for the development of such a strip would involve precise chemical formulations and calibration against known concentrations of ketones to ensure proper color development at specific thresholds, but this is not a "training set" in the AI sense.
    Ask a Question

    Ask a specific question about this device

    K Number
    K003987

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2001-04-26

    (121 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K953662

    Validate with FDA (Live)

    Date Cleared
    1996-06-14

    (312 days)

    Product Code
    Regulation Number
    862.1435
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview