Search Filters

Search Results

Found 551 results

510(k) Data Aggregation

    K Number
    K260783

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-03-11

    (1 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K254245

    Validate with FDA (Live)

    Device Name
    ZAFIRA®
    Manufacturer
    Date Cleared
    2026-03-03

    (64 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K260170

    Validate with FDA (Live)

    Device Name
    LumiCera
    Date Cleared
    2026-01-21

    (1 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    LumiCera is used for fabricating permanent single crowns, permanent inlays and onlays, veneers, bridges.

    Device Description

    The product should be used in combination with SHINING3D printer. The product is a liquid photo-curable material, which is produced by free radical polymerization of oligomers triggered by photoinitiator contained in the resin. The resin is printed in multiple layers automatically, with each layer being subjected to light curing before the addition of the next layer, and then undergoes post-curing in a curing device. The product is intended exclusively for professional dental work.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252465

    Validate with FDA (Live)

    Device Name
    Any-Core
    Manufacturer
    Date Cleared
    2025-12-05

    (121 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Repair material for provisionals
    • Cement for pins and posts
    • Semipermanent restorative material (e.g., in childrens' teeth)
    Device Description

    Any-Core is a dual-cured composite material intended for use in core build-up procedures and post cementation. The material demonstrates favorable mechanical properties and is formulated for direct intraoral application onto the tooth surface. Polymerization can be achieved by light-curing or self-curing, offering flexibility in clinical use. Any-Core is available in three shades—A3 (tooth-colored), White, and Blue—providing a combination of natural esthetics and visual contrast to aid in material identification during tooth preparation and placement. The product is supplied in a dual-barrel syringe and used with an automix tip, which enables intraoral dispensing without the need for manual mixing, supporting consistent and efficient delivery.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253513

    Validate with FDA (Live)

    Date Cleared
    2025-11-07

    (1 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Direct restorations in all cavity classes (I-V)
    • Base / liner under direct restoration
    • Veneering of discolored anterior teeth
    • Splinting of mobile teeth
    • Extended pit and fissure sealing in molars and premolars
    • Repair of composite/ceramic veneers
    • Retention of thermoplastic aligners

    The addition of anti-microbial particles to MultiMatch Flow Chameleon AntiMicrobial Composite reduces demineralization and the total amount of bacteria at the material surface, which is part of the caries-formation process.

    Device Description

    Premier's MultiMatch Flow Chameleon AntiMicrobial Composite is a low viscosity, light-cured, radiopaque, flowable nano-hybrid composite. It is for use in direct Class I-V restorations as a base liner, indirect restorations, and for retention of clear aligners. The restorative has an antimicrobial additive which reduces demineralization and total amount of bacteria at the material surface. The restorative is available in one chameleon shade to fit a variety of tooth-colored shades.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253236

    Validate with FDA (Live)

    Device Name
    G-BLOCK
    Date Cleared
    2025-09-29

    (0 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    G-BLOCK is intended to be used for the fabrication of permanent and temporary restorations such as dental implant prostheses, crowns, bridges, inlays, onlays and veneers.

    Device Description

    G-BLOCK is a compact block made of graphene-doped polymer suitable for the manufacture of dental prostheses using CAD/CAM technology. The polymer is based on polymethyl methacrylate (PMMA) doped with graphene (an allotrope of carbon).

    G-BLOCK is intended to be used for the fabrication of permanent and temporary restorations such as dental implant prostheses, crowns, bridges, inlays, onlays and veneers.

    G-BLOCK, compounded of polymethyl methacrylate (PMMA) doped with Graphene, is manufactured using the heat-curing method.

    G-BLOCK presents high modulus and elastic limit to ensure that the tensions generated during biting and chewing do not cause permanent deformations, and it is possible to manufacture prosthesis of smaller sections.

    G-BLOCK presents high deformation resistance and stress limit, thus avoiding the formation of cracks and fractures.

    G-BLOCK is low density making the prosthesis lightweight.

    G-BLOCK increases the material hardness comparing with acrylic resins used in dentistry.

    G-BLOCK has colour stability.

    G-BLOCK has wide chromatic range, even within the same piece, making it look extremely natural.

    G-BLOCK is chemically inert.

    G-BLOCK water absorption is 4 μg/mm³ and a solubility of 0.5 μg/mm². The release of residual monomer is minimum, with a percentage of 0.004% of residual monomer. Thanks to these physical properties G-BLOCK offers a durable and safety treatment.

    G-BLOCK is available in different formats, sizes and colors, having all variations the same physicochemical characteristics.

    The device is presented in the form of a polymer block glued to an aluminum pin that allows the device to be fixed on the milling machine so that the block can be milled to obtain dental prostheses with the use of specific CAD/CAM equipment.

    G-BLOCK is available in 2 different formats: MONOCHROMA and MULTICHROMA. Monochrome and Multichroma blocks may be both used for anatomical monolithic restorations.

    When machined, Monochroma and Multichroma present a different visual effect:

    • Monochroma, is made of a pure colour matching the dentin.

    • Multichroma, has a chromatic spectrum based on the natural colour imitating the optical effects of the natural dentition.

    Both variants are presented in two sizes: 14 and 40.

    G-BLOCK device is available in the following colours, A1, A2, A3, A3.5, B1, B2, BL1, BL2, C2 (according to G-CAM shade guide).

    G-BLOCK are provided non-sterile and as a single use device.

    G-BLOCK must be used only by professionals as dental lab technicians and / or dentist.

    G-BLOCK should be stored at room temperature in its original packaging, in dry storage and avoid exposure to direct sunlight. PMMA polymer from which the G-BLOCK is made is stable and can be stored for an extended period of 5-year shelf life.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253053

    Validate with FDA (Live)

    Date Cleared
    2025-09-23

    (1 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Dura-Crown is indicated as an indirect restorative for both anterior and posterior restorations, including occlusal surfaces. Dura-Crown is used for fabricating permanent restorations such as inlays, onlays, veneers, full crown and bridge restorations. Dura-Crown can also be used for the fabrication of artificial teeth and temporary crowns & bridges.

    Device Description

    The product should be used in combination with SHINING3D printer. It is stored in 500ml HDPE bottle. The product is a liquid photo-curable material, which is produced by free radical polymerization of oligomers triggered by a photoinitiator contained in the resin. Automated printing of the resin in multiple layers, each light-cured before adding next layer, are post cured in the cure device. The product is intended exclusively for professional dental work.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251946

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-08-29

    (65 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    0 - 21
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    1. Direct restorative for Class I, II, III, IV, and V cavities
    2. Fissure sealant
    3. Sealing hypersensitive areas
    4. Repair of (in)direct aesthetic restorations, temporary crown & bridge, defect margins when margins are in enamel
    5. Blocking out undercuts
    6. Liner or base
    7. Core build-up
    8. Adhesive cementation of ceramic and composite veneers, inlays and onlays with a thickness (<2.0 mm) and translucency that enables the complete light curing of the cement
    9. Retention of aligner e.g. by fabrication of aligner attachments
    Device Description

    G-ænial Universal Injectable II is a light-cured, nano-filled radiopaque composite resin filled in syringe. The device is used for the restoration of both anterior and posterior teeth, core build-up, adhesive cementation of ceramic and composite veneer, inlays and onlays, and build-up for transparent removable orthodontic retainers. The device is available in 9 shades.

    AI/ML Overview

    This document is an FDA 510(k) clearance letter for a dental resin material, G-ænial Universal Injectable II. It is important to note that this is NOT an AI/ML medical device submission. Therefore, the information provided in the document focuses on the material's physical and chemical properties and biocompatibility, as compared to predicate dental materials.

    The request asks for information typically found in submissions for AI/ML medical devices, such as acceptance criteria based on diagnostic performance metrics (e.g., sensitivity, specificity, AUC), details about test and training sets, expert consensus for ground truth, MRMC studies, and effect sizes of AI assistance. Since this is a dental material, these types of studies are not relevant and are not present in the provided document.

    Therefore, the following response will adapt the requested sections to the context of this dental material, explaining what information is available and what is not, given the nature of the device.


    Acceptance Criteria and Device Performance for G-ænial Universal Injectable II

    The acceptance criteria for G-ænial Universal Injectable II are based on established ISO standards for dental materials and FDA guidance for composite resin devices. The "study that proves the device meets the acceptance criteria" refers to the Performance Bench Tests and Non-Clinical Performance Testing detailed in Section 7 and 8 of the 510(k) summary. These tests assess the physical, chemical, and biological properties of the material.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are generally "Complies" with specific quantitative or qualitative thresholds defined by the standards (e.g., ISO 4049, ISO 6874). The document reports that the device Complies with all listed requirements.

    PropertyAcceptance Criterion (Requirement from Standards/Guidance)Reported Device Performance (G-ænial Universal Injectable II)
    Film thickness50 µm or less.Complies
    Sensitivity to lightRemain physically homogeneous.Complies
    Depth of cure (ISO 4049)Opaque shade; 1.0 mm or moreOther shade; 1.5 mm or moreComplies
    Flexural strength80 MPa or more.Complies
    Water sorption40 µg/mm³ or lessComplies
    Solubility7.5 µg/mm³ or lessComplies
    Shade of restoration materialsClosely match the shade of the shade guide. Shall be evenly pigmented.Complies
    Colour stability after irradiation and water sorptionNo more than slight change in colour.Complies
    Radio-opacityEqual to or greater than the radio-opacity of the same thickness of aluminium.Complies
    Depth of cure (ISO 6874)1.5 mm or moreComplies
    Compressive strength100 MPa or more.Complies
    Elastic modulusEquivalent or more than predicate device.Complies
    Surface hardnessEquivalent or more than predicate device.Complies
    Adhesive bond strengthEquivalent or more than predicate device.Complies
    Filler particle size0.01 - 0.5 μm (as per product description)This is a characteristic, not an acceptance criterion, but the device meets this range.

    2. Sample Size Used for the Test Set and Data Provenance

    For a dental material, the "test set" refers to the samples of the material manufactured and subjected to the performance bench tests and biocompatibility assessments.

    • Sample Size: The document does not specify the exact number of samples (e.g., number of specimens for flexural strength, number of animals for biocompatibility tests). It simply states that "Performance testing includes" and "A biocompatibility assessment was completed."
    • Data Provenance: The data provenance is internal to the manufacturer (GC America, Inc.) and derived from laboratory testing of the material according to international ISO standards and FDA guidance documents. There is no indication of "country of origin of the data" in the sense of patient data, nor is it a retrospective or prospective study in the clinical trial sense. These are laboratory-based material characterization tests.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This question is not applicable to a dental material submission. The "ground truth" for material properties is established by the standardized test methods themselves (e.g., ISO 4049 defines how depth of cure is measured). There are no "experts" establishing ground truth in the sense of clinical interpretations or diagnoses. The expertise lies in adhering to the established test protocols and analyzing results accurately by qualified laboratory personnel.

    4. Adjudication Method for the Test Set

    This concept is not applicable for dental material performance testing. Adjudication methods (like 2+1, 3+1 consensus) are used in studies involving human interpretation of images or clinical outcomes, typically for AI/ML device validation. Here, tests are quantitative measurements of physical/chemical properties or biological responses.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done, and Effect Size of Human Readers Improving with AI vs Without AI Assistance

    This question is not applicable. G-ænial Universal Injectable II is a dental restorative material, not an AI-assisted diagnostic or therapeutic device. There are no "human readers" involved in interpreting its performance, nor does it assist human readers. Therefore, no MRMC study was performed, and no effect size on human reader improvement with AI assistance can be reported.

    6. If a Standalone (i.e., Algorithm Only Without Human-in-the-Loop Performance) was Done

    This question is not applicable. G-ænial Universal Injectable II is a physical dental material, not an algorithm. There is no "standalone performance" of an algorithm. Its performance is measured directly through laboratory tests of its inherent material properties.

    7. The Type of Ground Truth Used (Expert Consensus, Pathology, Outcomes Data, etc.)

    For dental materials, the "ground truth" is based on:

    • Standardized Test Methods: Adherence to established ISO standards (e.g., ISO 4049, ISO 6874, ISO 10993) defines the "truth" for material properties like flexural strength, depth of cure, water sorption, and biocompatibility.
    • Predicate Device Comparison: Performance is also evaluated in comparison to predicate devices, where "equivalence" often serves as a benchmark for acceptance.

    There is no "expert consensus," "pathology," or "outcomes data" in the sense of human diagnostic performance or clinical trial results, as this is a pre-market notification for a material.

    8. The Sample Size for the Training Set

    This question is not applicable. There is no "training set" for a dental material in the context of machine learning. The material itself is manufactured, and specific properties are tested for quality control and regulatory submission.

    9. How the Ground Truth for the Training Set was Established

    This question is not applicable, as there is no training set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K251283

    Validate with FDA (Live)

    Device Name
    Once-Fil Flow
    Manufacturer
    Date Cleared
    2025-06-06

    (42 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Temporary inlay and onlay treatments of the cavity.
    • Sealing of openings for implant screws.
    • Relining material for temporary crowns and bridges.
    • Covering of the gingival margin
    • Fixing of resin matrix during filling placement.
    • Block-out material for retentive ares in the dental arch, e.g. before taking impressions.
    Device Description

    Once-Fil Flow is a light-curing filling material designed for temporary restorations. It serves as an interim solution before the placement of a final prosthesis, providing functions such as pulp protection and maintaining tooth position. The material is suitable for temporary fillings in prepared cavities and inlay/onlay cases.

    To accommodate different clinical needs, Once-Fil Flow is available in two shades. The Yellow shade is ideal for anterior teeth, where esthetics are a priority, while the Blue shade provides clear visual contrast, making it easier to identify and remove before permanent restoration.

    The application process involves preparing the tooth surface, applying an appropriate amount of material, and light-curing it. Once cured, the material can be finished and polished using conventional instruments.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for "Once-Fil Flow" does not describe an AI medical device or an AI/ML software. Instead, it pertains to a dental resin material. Therefore, the request to describe the acceptance criteria and study proving the device meets those criteria for an AI device cannot be fulfilled from the provided text.

    The information in the provided text focuses on the material characteristics and biocompatibility of a dental flowable resin. The regulatory context described is for a Class II medical device, product code EBF (Tooth Shade Resin Material), regulated under 21 CFR 872.3690.

    The document highlights the basis for substantial equivalence to a predicate device (Clip Flow by VOCO GmbH, K153493) through:

    • Identical Indications for Use: Temporary inlay/onlay, sealing implant screw openings, relining temporary crowns/bridges, covering gingival margin, fixing resin matrix, and block-out material.
    • Similar Technological Characteristics: Light curing type, similar materials (with minor differences confirmed by performance and biocompatibility), same intended user, similar delivery method, same period of use and shelf-life.
    • Performance Testing (Non-Clinical): Appearance, Weight, Packaging, Sensitivity to Ambient Light, Curing Depth, Water Sorption/Solubility, Color and Color Stability, and Shore D Hardness, all tested in accordance with ISO 4049 and ISO 868.
    • Biocompatibility Testing: ISO 10993 series tests including cytotoxicity, irritation, systemic toxicity, and skin sensitization.

    No information regarding AI, machine learning, clinical image analysis, or human reader studies is present in the provided text. The request for details on sample sizes for test sets, data provenance, expert adjudication, MRMC studies, standalone AI performance, ground truth types, and training set information is not applicable to this specific device (a dental resin material) based on the supplied documentation.

    Therefore, since the input document describes a physical dental material and not an AI/ML medical device, I cannot extract the requested information regarding AI acceptance criteria and study details.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250317

    Validate with FDA (Live)

    Device Name
    EsFlow PLUS
    Manufacturer
    Date Cleared
    2025-05-30

    (115 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Direct restorations
    • Base and Liner
    • Block out undercut
    • Repair of (in)direct aesthetic restorations
    • Core build-up
    Device Description

    EsFlow PLUS is a light-cured radiopaque flowable composite resin used for direct restoration. It has a smooth surface, so it is applied smoothly to the teeth, and has good gloss and aesthetics. In addition, it has high mechanical strength, so it can sufficiently withstand the occlusal force. EsFlow PLUS has two types of viscosities, so it can be applied to various clinical cases. The inorganic filler of EsFlow PLUS has a particle size range of 0.01 to 0.5 μm, and a volume ratio of about 42 to 47% depending on the model.

    AI/ML Overview

    I apologize, but the provided text from the FDA 510(k) Clearance Letter for "EsFlow PLUS" does not contain the information requested about acceptance criteria and the study proving the device meets those criteria, especially not in the context of an AI/ML medical device.

    The document is for a "Tooth Shade Resin Material" (a dental composite material), which is a physical material, not an AI/ML software device. The clinical studies mentioned (depth of cure, flexural strength, compressive strength) are material performance tests, comparing the new dental resin to a legally marketed predicate dental resin, and ensuring both meet ISO standards.

    Therefore, I cannot extract the following information from the provided text as it is not present for this type of device and study:

    • A table of acceptance criteria and the reported device performance (for an AI/ML device)
    • Sample size used for the test set and the data provenance
    • Number of experts used to establish the ground truth
    • Adjudication method
    • If a multi-reader multi-case (MRMC) comparative effectiveness study was done, or its effect size
    • If a standalone (algorithm only) performance was done
    • The type of ground truth used (expert consensus, pathology, outcomes data, etc.)
    • The sample size for the training set
    • How the ground truth for the training set was established

    The document focuses on the physical and mechanical properties of a dental composite material, comparing it to an existing material to demonstrate substantial equivalence, as required for a 510(k) clearance for this type of Class II device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 56