The Mesh Nebulizer designed to aerosolized liquid medications for inhalation by patient, the device may be used with pediatric (> 4 years of age) and adult patients in the home, hospital and sub-acute care settings.
It is not intended for use with Pentamidine.
The Mesh Nebulizer H6 is a portable handheld device that uses micromesh vibration technology to generate aerosols for inhalation by patients. The H6 consists of a main unit, a nebulizer cup and optional accessories, including inhalation masks (available in child and adult sizes), a mouthpiece and a power cord. The main unit housing is made of ABS material, the nebulizer cup is made of PC material, the inhalation mask is made of PP&TPE&silicone material, and the mouthpiece is made of PP&silicone material. It can be powered by an internal lithium battery or by an adapter that complies with the IEC 60601-1 standard.
N/A
Ask a specific question about this device
(263 days)
The portable mesh nebulizer is intended to aerosolize medicine liquid for inhalation by the patient. The device is used with adult and pediatric (≥3 years old) both in hospital, home, and sub-acute settings.
It is not intended for use with Pentamidine.
JM821 portable mesh nebulizer is a portable vibrating mesh nebulizer, which incorporates a piezoelectric transducer that vibrates at a nominal frequency when electrical current is applied. It is designed to nebulize liquid medications into fine particulates for inhalation by a patient, so as to therapy respiratory diseases.
The subject device is portable size, handheld design, it is powered by a 3.7V d.c. internally lithium battery, which is charged by an adapter.
The subject device does not contain any medicine. Only use physician-prescribed solutions that are approved for use with a general-purpose nebulizer. Consult drug manufacturer's instructions regarding suitability for nebulization.
The portable mesh nebulizer is single-patient, multiple-use. The mask can be can used for 30 sessions of aerosol treatment.
N/A
Ask a specific question about this device
(236 days)
The Compressor Nebulizer system is intended to provide air to the pneumatic nebulizer in order to aerosolize medications for inhalation by the patient for respiratory disorders. The nebulizer is driven by the integral air compressor.
The system is designed for use with pediatric (ages 2 years and above) and adult patients in the home, hospital, and sub-acute settings.
The compressor Nebulizer is mainly composed of the compressor and nebulizer kit(Optional). The compressor is mainly composed of shell, compressed motor, pump, fuse wire, air filter, power cord and plug (NB-1100,NB-1101,NB-1102,NB-1103 applicable), PCB (only model NB-1102,NB-1103applicable). The device is equipped with a nebulizer kit including Nebulizer Cup, Air Tube, Mouthpiece(Optional), Adult Mask(Optional), Child Mask(Optional) to easily delivery the medical aerosol. The Nebulizer kit is available in three models/configurations as below.
- NK-101: Nebulizer Cup, Air Tube, Adult Mask and/or Child Mask, Mouthpiece;
- NK-301: Nebulizer Cup, Air Tube, Adult Mask and/or Child Mask;
- NK-501: Nebulizer Cup, Air Tube, Mouthpiece
This device operates on the Venturi principle. According to the principle of Venturi, the compressed air of the motor is used to form a high-speed air flow through the small pipe mouth. The negative pressure generated drives the liquid or other fluid to spray together on the barrier, and under the high-speed impact makes the droplets turn into mist particles to spray from the outlet trachea.
The provided FDA 510(k) clearance letter and summary for JOYTECH Healthcare Co., Ltd.'s Compressor Nebulizer (K243468) primarily details the substantial equivalence of the new device to a predicate device, focusing on non-clinical performance testing, specifically particle size characterization.
It's important to note that this document does not describe a study involving human subjects or artificial intelligence (AI). The "acceptance criteria" and "study that proves the device meets the acceptance criteria" in this context refer to the engineering and performance specifications for a nebulizer, evaluated through laboratory testing against a predicate device and relevant standards. Therefore, many of the requested points related to AI/MRMC studies, expert ground truth, adjudication methods, and training sets for algorithms are not applicable to this specific device clearance.
Below is an interpretation of the provided information within the framework of your request, focusing on the relevant parts and explicitly stating where information is not available or not applicable.
Acceptance Criteria and Device Performance for JOYTECH Compressor Nebulizer (K243468)
The acceptance criteria for this device are established by demonstrating substantial equivalence to a legally marketed predicate device (Omron Compressor Nebulizer Systems NE-C801, K110860) and by meeting relevant performance standards, particularly regarding aerosol particle characterization. The 'study' proving this is primarily the "Particle Size characterization testing" detailed in the submission.
1. Table of Acceptance Criteria and Reported Device Performance
The acceptance criteria are implicitly defined by performing "comparative particle test comparison" against the predicate device. The goal is to show that the proposed device performs similarly or equivalently to the predicate across key aerosolization parameters. The performance data provided is the direct result of this testing.
Table: Comparative Particle Test Comparison (Summary of Select Parameters)
| Test Item | Endpoint (Acceptance Criteria Implicitly Compared to Predicate) | Subject Device (JOYTECH NB-1103) Performance (Range across drugs/interfaces) | Predicate Device (OMRON NEC801) Performance (Range across drugs/interfaces) | Comparison Result (as per Submitter) |
|---|---|---|---|---|
| MMAD ($\mu$m) | Particle size distribution suitable for inhalation therapy, comparable to predicate. | 3.413 - 5.757 | 3.7 - 6.248 | Equivalent / Similar |
| GSD | Particle size distribution uniformity, comparable to predicate. | 1.764 - 2.381 | 1.605 - 2.141 | Equivalent / Similar |
| Respirable Dose ($\mu$g) | Amount of drug delivered in respirable range, comparable to predicate. | 51.307 - 1628.633 | 50.723 - 1239.14 | Equivalent / Similar |
| Respirable Fraction (%) | Proportion of aerosolized drug in respirable range, comparable to predicate. | 39.103 - 67.958 | 31.781 - 63.741 | Equivalent / Similar |
| Total Delivered Dose ($\mu$g) | Total amount of drug delivered, comparable to predicate. | 112.976 - 2562.202 | 146.303 - 2131.073 | Equivalent / Similar |
| Total Delivered Dose Fraction (%) | Proportion of initial drug dose delivered, comparable to predicate. | 21.305 - 49.063 | 27.55 - 40.801 | Equivalent / Similar |
| Fine Particle Fraction (%) (<4.7$\mu$m) | Percentage of particles less than 4.7 $\mu$m, comparable to predicate. | 35.454 - 64.77 | 27.946 - 60.533 | Equivalent / Similar |
| Coarse Particle Fraction (%) (>4.7$\mu$m) | Percentage of particles greater than 4.7 $\mu$m, comparable to predicate. | 35.232 - 64.547 | 39.467 - 72.054 | Equivalent / Similar |
| Ultra-Fine Particle Fraction (%) (<1.0$\mu$m) | Percentage of particles less than 1.0 $\mu$m, comparable to predicate. | Ranges provided are minimal/absent for Budesonide, otherwise 4.006-5.891 | Ranges provided are minimal/absent for Budesonide, otherwise 2.456-4.26 | Equivalent / Similar |
Note: The ranges represent the lowest and highest values across the tested drugs (Albuterol Sulfate, Ipratropium Bromide, Budesonide) and patient interfaces (adult mask, child mask, mouthpiece) for both adult and pediatric conditions. The "Comparison Result" is the submitter's statement from the document.
2. Sample Size Used for the Test Set and Data Provenance
- Sample Size: The tables show mean and standard deviation values for each parameter, implying multiple measurements were taken for each drug and interface combination. However, the exact number of replicates (sample size for each data point in the tables) is not explicitly stated in the provided text. It is typically standard practice in such testing to perform a minimum of triplicate measurements.
- Data Provenance: The data is generated from laboratory performance testing of the device and its predicate. This is a non-clinical study.
- Country of Origin: The manufacturer, JOYTECH Healthcare Co., Ltd., is located in Hangzhou City, Zhejiang, China. The predicate manufacturer, Omron Healthcare, Incorporated, is typically based in Japan with a strong presence in the US. The testing itself would have been conducted in a certified lab, likely in China or an associated region.
- Retrospective or Prospective: This is prospective laboratory testing conducted specifically for this 510(k) submission.
3. Number of Experts Used to Establish Ground Truth and Qualifications
Not applicable. This study does not involve expert interpretation of medical images or patient data to establish a ground truth. Instead, it involves physical and chemical measurements (particle size and drug delivery) performed on the nebulizer using standardized laboratory methods outlined in FDA guidance and relevant ISO standards (e.g., ISO 18562 series). The "ground truth" is derived from these objective measurements and comparison to the predicate's performance.
4. Adjudication Method for the Test Set
Not applicable. As this is laboratory performance testing, there's no "adjudication" in the sense of reconciling human expert opinions. The results are quantitative measurements.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done
No, an MRMC comparative effectiveness study was not done. This device is a medical device for drug delivery, not an AI diagnostic or assistive tool for human readers. Therefore, there is no human-in-the-loop performance to improve with AI assistance.
6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) was Done
Not applicable. This device is hardware (a compressor nebulizer), not a software algorithm.
7. The Type of Ground Truth Used
The "ground truth" for this device's performance testing is objective physical and chemical measurement data obtained through standardized laboratory protocols (e.g., cascade impaction for particle sizing, chemical analysis for drug quantity) rather than expert consensus, pathology, or outcomes data. The acceptability is determined by evaluating if these measurements are comparable to the well-established performance of a predicate device already on the market and align with general principles for effective nebulizer function.
8. The Sample Size for the Training Set
Not applicable. This is not an AI/machine learning device, so there is no "training set."
9. How the Ground Truth for the Training Set Was Established
Not applicable. There is no "training set" or "ground truth" in the context of an AI model for this device.
Ask a specific question about this device
(178 days)
The HeroTracker Sense Device (HTS) is an add-on device which is attached by patients on a metered-dose inhaler (MDI).
HTS is intended for single-patient multiple use in the home environment as an electronic data capture accessory for monitoring and recording actuation, inhaler shake, inhaler orientation, inhalation coordination, and inspiratory strength and duration for prescribed inhaler usage.
HTS may be used in the following applications: in clinical practice or clinical trials, where specialists, general practitioners, nurses and educators need to know if a patient has used their prescribed medication or assess inhaler technique.
HTS is designed to work only with the MDI and medication indicated on the HTS label.
HTS is not intended to indicate the remaining quantity of medication in an inhaler and does not include a dose counting function.
HTS is not intended to provide spirometry measurements.
HTS is intended to be used by Metered Dose Inhaler (MDI) users aged 12 years and over.
The HeroTracker Sense (HTS) is a nebulizer accessory. It is an add-on device which is attached by patients on a metered dose inhaler (MDI) and is used to record and analyze data related to medication actuation and technique of use for prescribed inhaler usage. Data is transferred to a mobile application with appropriate settings and is displayed to end users.
The provided FDA 510(k) Clearance Letter for HeroTracker Sense (HTS) does not contain the detailed information necessary to answer all parts of your request regarding acceptance criteria and a study proving the device meets those criteria. The document primarily focuses on demonstrating substantial equivalence to a predicate device based on non-clinical performance data.
Here's a breakdown of what can be gleaned from the document and what information is missing:
Missing Information: The document explicitly states "No clinical data was necessary to determine the substantial equivalence of this device." This means there was likely no "performance study" in the traditional sense, with a clinical test set, ground truth experts, adjudication, or MRMC studies. The acceptance criteria for performance would have been established and demonstrated through non-clinical testing.
Therefore, many of the sections you requested (e.g., sample size for test set, number of experts, adjudication, MRMC, specific effect sizes, ground truth type for test set the training set) cannot be answered from the provided text.
Inference from Document's Purpose: The 510(k) process for this device relies heavily on demonstrating that the HeroTracker Sense (HTS) functions similarly to its predicate device (Hailie® Sensor NF0110) and that any differences do not raise new questions of safety or effectiveness. The performance validation would have been against defined specifications for each function, likely derived from the predicate device's capabilities and internal design requirements.
Acceptance Criteria and Device Performance (Based on available non-clinical data)
Since clinical data was not required, the "acceptance criteria" for the device would be met by passing the non-clinical performance and safety tests. The "reported device performance" is essentially that it "passed" these tests and met its internal specifications.
Table of Acceptance Criteria and Reported Device Performance (Inferred from Non-Clinical Testing):
| Acceptance Criteria Category | Specific Criteria (Inferred from testing) | Reported Device Performance |
|---|---|---|
| Biocompatibility | Materials are biocompatible (ISO 10993-1) | Passed - "Materials can be considered as biocompatible." |
| Electrical Safety | Compliance with IEC 60601-1, IEC 60601-1-11, IEC 60601-1-6 | Passed |
| Electromagnetic Disturbance (EMD) | Compliance with IEC 60601-1-2 | Passed |
| Software Functionality | Correct functionality of HTS software, modules, and mobile app association (IEC 62304/FDA Guidance) | Passed - "verified" |
| Breathing Gas Pathway Biological Safety | Risk-based evaluation adequacy (ISO 18562-1) | Passed - "considered adequately addressed." |
| Core Performance (Data Recording Accuracy) | Device meets specifications for recording actuation, inhaler shake, inhaler orientation, inhalation coordination, inspiratory strength and duration | Passed - "Device was verified to meet specifications and the correct functionality and compatibility for the HTS with the concerned MDI inhalers was verified" |
| Service Life | At least 1 year service life | Passed - "Supports 1 year service life" |
| Shelf-Life | At least 2 years shelf life | Passed - "Supports 2 years shelf life" |
| Transportation Impact | Transport has no impact on device (ASTM 4169) | Passed - "confirmed the transport has no impact on device." |
Study Details (Based on available information and limitations)
Given the explicit statement that "No clinical data was necessary to determine the substantial equivalence of this device," the following sections reflect this limitation. The "study" refers to the non-clinical verification and validation activities.
-
A table of acceptance criteria and the reported device performance:
- (Provided above, based on non-clinical testing outcomes).
-
Sample sizes used for the test set and the data provenance:
- Test Set Sample Size: Not applicable in the context of a clinical test set. For non-clinical performance testing (e.g., electrical safety, software validation, sensor accuracy), the sample sizes would refer to the number of devices or test iterations used. This specific detail is not provided in the document.
- Data Provenance: Not applicable in the sense of patient data. The tests were performed in a lab or testing facility environment.
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- Not applicable. No clinical ground truth experts were used as no clinical data was required. Ground truth for non-clinical performance (e.g., whether a sensor accurately detects an actuation) would be established by validated test methods and reference standards, not human expert consensus.
-
Adjudication method (e.g., 2+1, 3+1, none) for the test set:
- Not applicable. There was no human expert adjudication as no clinical test set with subjective interpretations was used.
-
If a multi-reader multi-case (MRMC) comparative effectiveness study was done:
- No. The document explicitly states "No clinical data was necessary." Therefore, no MRMC study comparing human readers with and without AI assistance was performed.
-
If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:
- Yes, implicitly. The "Performance Testing" section confirms that the device was "verified to meet specifications" and its "correct functionality and compatibility" was verified. This implies standalone performance testing of the device's ability to record and analyze data from the MDI. The "algorithm" itself (which processes sensor data to identify events like actuation, shake, etc.) would have been validated against controlled physical actions.
-
The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
- Instrumental/Physical Ground Truth: For the non-clinical performance tests, the "ground truth" would be established by controlled physical inputs and reference measurements. For example:
- For "actuation," the ground truth would be a definitively measured actuation event.
- For "inhaler shake," the ground truth would be a quantitatively measured shaking motion.
- For software functionality, the ground truth would be predefined correct outputs for given inputs.
- Instrumental/Physical Ground Truth: For the non-clinical performance tests, the "ground truth" would be established by controlled physical inputs and reference measurements. For example:
-
The sample size for the training set:
- Not applicable / Not specified. This device is an electronic data capture accessory. While it uses sensors and potentially algorithms to interpret movements, the document doesn't indicate that it employs machine learning or AI that would require a "training set" in the typical sense (e.g., for image classification or complex pattern recognition). Its function seems to be based on pre-defined thresholds and sensor data processing rather than adaptive learning from a large training dataset. If any "calibration" or initial parameter setting was done, the size of that dataset is not provided.
-
How the ground truth for the training set was established:
- Not applicable. As no training set is indicated.
Ask a specific question about this device
(113 days)
The AdheResp Smart Breath-actuated Mesh Nebulizer is a system to aerosolize liquid medications for inhalation for patients ranging from pediatrics equal to or greater than 5 years old to adults who can coordinate breathing.
The environment of use are Hospital/institutional settings, home care use, schools, and long-term care facilities.
The AdheResp Smart Breath-actuated Mesh Nebulizer consists of a main unit, medication reservoir, mouthpiece, key tag and charging cable, or power adapter. The medication reservoir could be further separated into a medication container and an aerosol chamber.
Principle of Operation: There are two key features in the AdheResp Smart Breath-actuated Mesh Nebulizer, which are vibrating mesh nebulization and breath-actuation functions. The AdheResp Smart Breath-actuated Mesh Nebulizer is an active mesh nebulizer. Active mesh nebulizers operate by electrically activating a piezoelectric (PZT) ceramic element that rapidly contracts and expands when applied a voltage to it. The vibrations of the PZT are transmitted to the mesh membrane, which is in contact with the liquid medication loaded in the medication container. This vibration pushes the liquid or suspension through the fine conical holes of the mesh, forming aerosol droplets for the user to inhale.
This document is a 510(k) clearance letter for the AdheResp Smart Breath-actuated Mesh Nebulizer. It outlines the device's characteristics and its equivalence to predicate devices, particularly focusing on performance data related to aerosol delivery.
Here’s the breakdown of the acceptance criteria and the study that proves the device meets them, based on the provided text:
Important Note: The provided text is a 510(k) summary and clearance letter. It summarizes findings and states that acceptance criteria were met, but it does not provide the detailed study protocols, raw data, or the explicit acceptance criteria values themselves in a direct, quantifiable manner for all aspects. Instead, it presents comparative performance data and lists categories of testing. Therefore, some information will be inferred from the context or noted as 'not explicitly stated' if the document does not provide it.
1. Table of Acceptance Criteria and Reported Device Performance
The document doesn't explicitly state quantitative acceptance criteria for each parameter in a "limit" vs. "result" format. Instead, it presents comparative performance data against a predicate device and states that the subject device "met its acceptance criteria" and that its performance is "similar." For the purpose of this table, I will present the reported performance of the Subject Device and mention the comparison to the Predicate. The implicit acceptance criterion for the comparative performance data is that the subject device's performance is demonstrably non-inferior or similar to the predicate.
| Acceptance Criterion (Implicit) | Reported Device Performance (Subject Device) |
|---|---|
| Particle Size (MMAD): Similar to predicate device | 15 LPM: Albuterol 3.98 ±0.18 µm, Ipratropium 3.984 ±0.11 µm, USP Cromolyn 4.07 ±0.14 µm (Predicate generally higher MMAD) |
| 30 LPM: Albuterol 3.48 ±0.15 µm, Ipratropium 3.39 ±0.21 µm, USP Cromolyn 3.58 ±0.15 µm (Predicate generally higher MMAD) | |
| Geometric Standard Deviation (GSD): Similar to predicate | 15 LPM: Albuterol 1.82 ±0.03, Ipratropium 1.94 ±0.10, USP Cromolyn 1.88 ±0.02 (Predicate generally higher GSD) |
| 30 LPM: Albuterol 1.89 ±0.09, Ipratropium 1.98 ±0.16, USP Cromolyn 1.90 ±0.07 (Predicate generally higher GSD) | |
| Total Delivered Dose (mg): Similar to predicate | 15 LPM: Albuterol 4.25 ±0.36, Ipratropium 0.45 ±0.07, USP Cromolyn 16.23 ±1.35 (Subject generally slightly higher or similar to Predicate) |
| 30 LPM: Albuterol 3.83 ±0.29, Ipratropium 0.40 ±0.04, USP Cromolyn 14.65 ±1.09 (Subject generally slightly higher or similar to Predicate) | |
| Respirable Dose <5µm [mg]: Similar to predicate | 15 LPM: Albuterol 2.71 ±0.32, Ipratropium 0.28 ±0.03, USP Cromolyn 10 ±0.85 (Subject generally higher than Predicate) |
| 30 LPM: Albuterol 2.67 ±0.21, Ipratropium 0.27 ±0.03, USP Cromolyn 9.95 ±0.71 (Subject generally higher than Predicate) | |
| Coarse Particle Dose <4.7µm [mg]: Similar to predicate | 15 LPM: Albuterol 1.47 ±0.10, Ipratropium 0.15 ±0.02, USP Cromolyn 5.85 ±0.65 (Subject generally lower or similar to Predicate) |
| 30 LPM: Albuterol 1.05 ±0.28, Ipratropium 0.11 ±0.01, USP Cromolyn 4.55 ±0.72 (Subject generally lower or similar to Predicate) | |
| Fine Particle Dose <4.7µm [mg]: Similar to predicate | 15 LPM: Albuterol 2.56 ±0.30, Ipratropium 0.27 ±0.03, USP Cromolyn 9.41 ±0.65 (Subject generally higher than Predicate) |
| 30 LPM: Albuterol 2.54 ±0.21, Ipratropium 0.26 ±0.03, USP Cromolyn 9.46 ±0.48 (Subject generally higher than Predicate) | |
| Ultra-Fine Particle Dose <1µm [mg]: Similar to predicate | 15 LPM: Albuterol LOD, Ipratropium 0.01 ±0.00, USP Cromolyn LOD (Similar to Predicate) |
| 30 LPM: Albuterol 0.21 ±0.06, Ipratropium 0.02 ±0.01, USP Cromolyn 0.58 ±0.05 (Similar to Predicate) | |
| Nebulization Rate: Must meet specified rate | >0.25 ml/min (Similar to predicate) |
| Inter- and Intra-sample Variability: Must meet criteria | Met acceptance criteria (no specific values given) |
| Minimum Breath Actuation Tests: Must meet criteria | Met acceptance criteria (no specific values given) |
| Biocompatibility (ISO 10993 & ISO 18562): Must pass tests | Applicable ISO 10993 and ISO 18652 testing was performed and passed. |
| Reprocessing, Sterility, and Shelf-Life: Must pass tests | Cleaning Validation, Aging, Simulated Life (cleaning, aging, drop) were performed and passed. (implicitly met acceptance criteria related to these tests) |
2. Sample Size Used for the Test Set and Data Provenance
- Sample Size for Test Set:
- For the comparative performance testing (Breath Actuated Particle Characterization): "Testing was performed with 3 samples of each device in triplicate with the 3 drugs." This implies $3 \text{ devices} \times 3 \text{ replicates} = 9$ runs per drug per flow rate for both the subject and predicate devices.
- Data Provenance: Not explicitly stated (e.g., country of origin). The study is non-clinical bench testing ("Bench testing," "Non-Clinical Testing Summary"), meaning it's a controlled lab environment, not patient data. It is a prospective study in the sense that the tests were conducted specifically for this submission.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications
- Number of Experts: Not applicable. This device is a nebulizer, and the tests described are bench tests (e.g., particle size, dosage, flow rates). These are physical measurements, not interpretations of medical images or patient conditions that would require expert human readers to establish ground truth.
- Qualifications of Experts: N/A, as noted above.
4. Adjudication Method for the Test Set
- Adjudication Method: Not applicable. This is not a study involving human interpretation of data, where adjudication of disagreements would be necessary. The performance data is derived from direct and repeatable physical measurements.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done
-
MRMC Study: No. An MRMC study is typically performed for AI/CADe (Computer-Assisted Detection/Diagnosis) devices that assist human readers in interpreting medical images. This device is a nebulizer, a drug delivery system, and its performance is evaluated through bench testing.
-
Effect Size of Human Readers' Improvement: Not applicable, as no MRMC study was performed.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done
- Standalone Performance: Yes, in essence. The "AdheResp Smart Breath-actuated Mesh Nebulizer" itself has an algorithm for "Breath Actuation" that "Measures breath and averages the cycle, then delivers aerosol during the designated period." The "Breathe Actuated Particle Characterization Performance Comparison" is a standalone evaluation of the device's physical output based on this internal algorithm responding to simulated breathing patterns (15 LPM and 30 LPM). There is no "human-in-the-loop" for the output of the device itself.
7. The Type of Ground Truth Used
- Type of Ground Truth: The ground truth for this device's performance is established by standardized laboratory measurements using traceable equipment and protocols (e.g., measuring particle size, drug quantity, flow rates) under controlled conditions. This is considered an objective physical truth, not a subjective interpretation. The comparison is made against a legally marketed predicate device's performance.
8. The Sample Size for the Training Set
- Training Set Sample Size: Not applicable. This device is a physical medical device (nebulizer) with an embedded algorithm, not a machine learning/AI model that requires a "training set" of data in the typical sense for image recognition or diagnostic purposes. The device's "algorithm" is for controlling the nebulization based on breath patterns, which would be developed through engineering and control system design, not data-driven machine learning.
9. How the Ground Truth for the Training Set Was Established
- Ground Truth for Training Set Establishment: Not applicable, as there is no "training set" in the context of a machine learning model. The "ground truth" for the device's operational parameters (like breath-actuation logic or aerosol delivery range) would be based on established engineering principles, physiological understanding of human breathing, and clinical requirements for drug delivery, validated through rigorous bench testing and potentially human factors testing, though the latter is not detailed in this summary.
Ask a specific question about this device
(264 days)
AllNEB Breath Actuated Nebulizer is intended for adults and pediatric patients over 5 years old, who are under the care or treatment of a licensed healthcare provider or physician. AllNEB is intended for the administration of aerosolized medication prescribed by a physician or healthcare professional. AllNEB is to be used at home or in hospitals and clinics.
AllNEB is a jet nebulizer intended to administer medication (prescribed by a physician or health care provider) in the form of an aerosol for patient inhalation. It operates in conjunction with a compressed air source and a liquid medication. The subject device is designed to produce and deliver aerosolized medication only during the patient inspiratory cycle, reducing fugitive emissions to the environment. It can be used in hospitals, clinics and in the home.
This document is a 510(k) clearance letter for a medical device called "AllNEB Breath Actuated Nebulizer." It demonstrates the device's substantial equivalence to a legally marketed predicate device, the AeroEclipse II Breath Actuated Nebulizer (K053605).
The core of the acceptance criteria and proof revolves around comparative performance testing, showing that the AllNEB device performs similarly to the predicate device across various aerosolization metrics.
Here's an analysis of the acceptance criteria and the study that proves the device meets them, based on the provided text:
1. Table of Acceptance Criteria and Reported Device Performance
The acceptance criteria for this device are implicitly derived from the performance of the predicate device. The goal is to demonstrate "substantial equivalence," meaning the new device performs similarly to the predicate. The performance of the predicate device, AeroEclipse II Breath Actuated Nebulizer (K053605), serves as the "acceptance criteria," and the "Reported Device Performance" is that of the AllNEB device.
The tables provided in the 510(k) summary (pages 7-16) present a direct comparison of various aerosolization parameters for both the AllNEB (Subject Device) and the AeroEclipse II (Predicate Device) under different conditions (Breath Actuated Mode, Constant-Output Mode, Adult settings, Pediatric settings, and Simulated Breathing).
Key Performance Metrics (Acceptance Criteria are inferred to be "similar to predicate"):
- MMAD (Mass Median Aerodynamic Diameter): A measure of the central tendency of the particle size distribution.
- GSD (Geometric Standard Deviation): A measure of the spread or variability of the particle size distribution.
- Total Dose Delivered: The total amount of medication delivered by the nebulizer.
- Total Respirable Dose (0.5-5 µm): The amount of medication delivered as particles within the respirable range (able to reach the lower respiratory tract).
- Coarse Particle Dose (>4.7 µm): The amount of medication delivered as larger particles.
- Fine Particle Dose (<4.7 µm): The amount of medication delivered as smaller particles.
- Ultra-Fine Particle Dose (<1.0 µm): The amount of medication delivered as very small particles.
Example Excerpt from the Tables (Acceptance Criteria vs. Reported Performance):
| Metric (Albuterol Sulfate, Breath Actuated Mode – Adult settings, 5 lpm) | Acceptance Criteria (Predicate) | Reported Performance (AllNEB) | Comment |
|---|---|---|---|
| MMAD | 2.03 | 1.51 | Similar |
| GSD | 1.70 | 2.43 | Similar |
| Total Dose Delivered | 1,367 | 1,228 | Similar |
| Total Respirable Dose (0.5-5 um) | 847 | 834 | Similar |
| Coarse Particle Dose (>4.7 um) | 350 | 218 | Similar |
| Fine Particle Dose (<4.7 um) | 1,017 | 1,010 | Similar |
| Ultra-Fine Particle Dose (<1.0 um) | 307 | 397 | Similar |
(Self-Correction: The "Similar" comment applies to all comparative data points presented in the submission, indicating that the observed differences were deemed acceptable for substantial equivalence for all the data points included in these tables.)
The acceptance criterion for each measured value is that the AllNEB device's performance is "similar" to that of the predicate device. The tables, consistently marked with "Similar" in the comment column, indicate that this criterion was met for all tested parameters and conditions.
2. Sample Size Used for the Test Set and Data Provenance
The provided document does not specify the sample size (e.g., number of nebulizers tested, number of runs per nebulizer) used for the comparative performance testing. It presents the mean values for various measurements. The typical practice for such in vitro performance testing of nebulizer devices would involve multiple repetitions to ensure reproducibility and statistical validity, but the exact N is not given here.
The data provenance is also not explicitly stated regarding the country of origin or whether it was retrospective or prospective. However, given that this is a 510(k) submission for a new device, the performance testing would undoubtedly be prospective and conducted by the manufacturer (Enchant Tek Co. Ltd.) as part of their pre-market submission requirements. The location of the sponsor (Taipei, TW) suggests the testing likely occurred in Taiwan or through a contract research organization.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications
This document describes the performance testing of a physical medical device (nebulizer) based on in vitro aerosolization characteristics, not a diagnostic AI/ML algorithm that requires expert adjudication of medical images or patient data.
Therefore, the concept of "experts used to establish the ground truth" in the sense of medical professionals (e.g., radiologists, pathologists) is not applicable here. The "ground truth" for the performance data is established by the methods and equipment used for aerosol particle sizing and dose measurement (e.g., cascade impactors, spectrophotometry), which are standard industry practices and governed by international standards (e.g., ISO 27427 for nebulizing systems). The "experts" would be the engineers and technicians proficient in running these highly standardized tests.
4. Adjudication Method for the Test Set
As explained above, since this is a performance test for a physical device, not an AI/ML diagnostic system based on human interpretation, an "adjudication method" (like 2+1 or 3+1 reviewer consensus for image reads) is not applicable. The data are quantitative measurements obtained through standardized laboratory procedures.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done
No, an MRMC comparative effectiveness study was not conducted. This type of study is typically performed for diagnostic devices (especially those involving interpretation of medical images or signals) to assess how human performance (e.g., accuracy, efficiency) changes with and without AI assistance. The AllNEB is a drug delivery device, not a diagnostic tool requiring human interpretation of output.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done
Not Applicable. This question is relevant for AI/ML devices where the algorithm's performance can be evaluated independently. The AllNEB is a mechanical device, and its performance is inherently "standalone" in terms of its aerosolization characteristics (it functions as designed regardless of a human interface beyond its intended use).
7. The Type of Ground Truth Used
The "ground truth" for the device's performance is established by physical measurements and testing using standardized laboratory equipment and methods. These methods quantitatively assess:
- Particle size distribution (MMAD, GSD)
- Drug delivery efficiency (Total Dose Delivered, Respirable Dose, etc.)
These measurements are considered the objective "ground truth" for the device's physical performance characteristics. The comparison is made against the results obtained with the predicate device using the same methodologies.
8. The Sample Size for the Training Set
Not Applicable. This device is a mechanical nebulizer, not an AI/ML algorithm that requires a "training set."
9. How the Ground Truth for the Training Set was Established
Not Applicable. As there is no training set for a mechanical device, there is no ground truth to be established for it.
Ask a specific question about this device
(225 days)
Model number 1024 is a single patient, disposable device for dispensing pressurized metered dose inhaler (pMDI) medication into a breathing circuit, as prescribed by a physician or other licensed health care practitioner. The device is indicated for patients on a breathing circuit, for whom aerosol medication has been prescribed, in short and long term critical care environments. REF 1024 is intended for use only when connected to a 22 mm fitting.
Model number 1024A is a single patient, disposable device for dispensing pressurized metered dose inhaler (pMDI) medication into a breathing circuit, as prescribed by a physician or other licensed health care practitioner. The device is indicated for patients on a breathing circuit, for whom aerosol medication has been prescribed, in short and long term critical care environments. REF 1024A is intended for use only when connected to a 22 mm fitting.
Model number 1025 is a single patient, disposable device for dispensing pressurized metered dose inhaler (pMDI) medication into a breathing circuit, as prescribed by a physician or other licensed health care practitioner. The device is indicated for patients on a breathing circuit, for whom aerosol medication has been prescribed, in short and long term critical care environments. REF 1025 is intended for use only when connected to a 22 mm fitting.
Model number 1025A is a single patient, disposable device for dispensing pressurized metered dose inhaler (pMDI) medication into a breathing circuit, as prescribed by a physician or other licensed health care practitioner. The device is indicated for patients on a breathing circuit, for whom aerosol medication has been prescribed, in short and long term critical care environments. REF 1025A is intended for use only when connected to a 22 mm fitting.
Model number 1543 is a single patient, disposable device for dispensing pressurized metered dose inhaler (pMDI) medication into a breathing circuit, as prescribed by a physician or other licensed health care practitioner. The device is indicated for patients on a breathing circuit, for whom aerosol medication has been prescribed, in short and long term critical care environments. REF 1543 is intended for use only when connected to a 15 mm fitting.
Model number 1543A is a single patient, disposable device for dispensing pressurized metered dose inhaler (pMDI) medication into a breathing circuit, as prescribed by a physician or other licensed health care practitioner. The device is indicated for patients on a breathing circuit, for whom aerosol medication has been prescribed, in short and long term critical care environments. REF 1543A is intended for use only when connected to a 15 mm fitting.
Model numbers 1024, 1025, 1543, 1024A, 1025A and 1543A are breathing circuit connectors that function as general purpose actuators for dispensing prescribed aerosolized medication from a pressurized metered dose inhaler (hereafter referred to as "pMDI") canister into a breathing circuit.
The provided text is a 510(k) Premarket Notification from the FDA regarding a medical device called the MiniSpacer Dual Spray MDI Adapter. This document is a regulatory submission for a device, which typically describes an engineering verification and validation study rather than a clinical study for AI software.
Therefore, the requested information regarding acceptance criteria and performance against those criteria, especially details such as sample size for test sets, data provenance, expert ground truth adjudication, MRMC studies, standalone algorithm performance, and training set information (which are all highly relevant to AI/ML device evaluations), is not present in this document. The document primarily focuses on demonstrating substantial equivalence to predicate devices based on design, materials, intended use, and general performance, rather than AI-specific metrics.
However, I can extract the following relevant information based on the request, reinterpreting some categories in the context of a non-AI medical device submission:
Acceptance Criteria and Device Performance
- Product: MiniSpacer® 1024, 1025, 1543 and 1024A, 1025A, 1543A Dual Spray MDI Adapter
- Study Type: This document describes a premarket notification (510(k)) to establish substantial equivalence to predicate devices, not a clinical trial or AI performance study. The "study" here refers to the engineering verification and biocompatibility assessment for the physical device.
| Acceptance Criterion (Standard or Predicate Equivalence) | Reported Device Performance |
|---|---|
| Material Equivalence: | |
| - Body Material: Modified SBC performance equivalent to | Toxicological assessment supports substantial equivalence and |
| Legacy SBC. | biological safety for the intended device population compared to |
| - Other Materials (Actuator, Cap): ABS, SEBS equivalent | predicate devices. |
| to predicate. | |
| Functional Equivalence: | The subject device shares the same intended use, indications for |
| - Dispensing pMDI medication into breathing circuit. | use, common name, classification, and regulatory status as the |
| - Single patient, disposable. | predicate devices. It also maintains the same dimensions and dual |
| - Prescription device. | spray orifice nozzle design. |
| - Non-sterile. | |
| Biocompatibility: | |
| - Meeting biocompatibility standards for external | A thorough toxicological assessment was performed, and the data |
| communicating, tissue, long-term (> 30 days) contact. | supports substantial equivalence and biological safety for the |
| intended device population, despite a change in the body resin. |
Additional Requested Information (as applicable to this document):
-
Sample sizes used for the test set and data provenance:
- Test Set Sample Size: Not specified in the document. The testing described appears to be bench testing for material and functional equivalence.
- Data Provenance: Not explicitly stated, but the toxicological assessment and comparisons against predicate devices would be based on internal testing and regulatory standards. It's a regulatory submission, not a clinical trial, so "country of origin" of data or "retrospective/prospective" does not apply in the typical sense for patient data.
-
Number of experts used to establish the ground truth for the test set and their qualifications:
- Not applicable in the context of this device. Ground truth is established through engineering specifications, material standards, and regulatory requirements (e.g., biocompatibility testing interpreted by toxicologists) rather than expert consensus on medical images or patient outcomes.
-
Adjudication method for the test set:
- Not applicable. This is not a study requiring adjudication of expert interpretations. Compliance is determined by engineering testing and regulatory assessment.
-
If a multi-reader multi-case (MRMC) comparative effectiveness study was done, and its effect size:
- No, an MRMC study was not done. This device is a physical medical component (an actuator for MDI medication), not an AI diagnostic or treatment planning system that would involve human readers interpreting data.
-
If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:
- Not applicable. This device does not involve an algorithm or AI component.
-
The type of ground truth used:
- For material and functional performance, the "ground truth" is defined by established engineering specifications, performance standards, mechanical testing results, and toxicological assessment standards. For regulatory approval, the ultimate "ground truth" is established by demonstrating substantial equivalence to legally marketed predicate devices through comparative analysis and testing.
-
The sample size for the training set:
- Not applicable. This device does not involve machine learning or a training set.
-
How the ground truth for the training set was established:
- Not applicable, as there is no training set for an AI/ML algorithm.
Ask a specific question about this device
(266 days)
The Aerogen® Solo Nebulizer System includes the Aerogen® Solo Nebulizer, which is intended to aerosolize physicianprescribed medications for inhalation to patients on and off ventilation or other positive pressure breathing assistance in the hospital environment.
Aerogen® Solo Nebulizer is for single-patient use. The Aerogen Solo nebulizer is for pediatric (29 days or older) and adult patients.
The Aerogen® USB Controller System includes the Aerogen® Solo Nebulizer, which is intended to aerosolize physicianprescribed medications for inhalation to patients on and off ventilation or other positive pressure breathing assistance in the hospital environment, and on vent only in the homecare environment.
Aerogen® Solo Nebulizer is for single patient use. The Aerogen Solo nebulizer is for pediatric (29 days or older) and adult patients.
The Aerogen® Solo Nebulizer System consists of the Aerogen® Solo Nebulizer, which has the proposed modification outlined in these 510(k) applications, and the Aerogen® Pro-X Controller (K133360 for both components and system) or the Aerogen Solo Nebulizer can also be used alternatively with the reference device - Aerogen® USB Controller (K143719).
The Aerogen® Solo Nebulizer is intended to aerosolize physician-prescribed medications for inhalation which are approved for use with a general-purpose nebulizer. It is intended for use on and off mechanical ventilation or other positive pressure breathing assistance and is intended for both intermittent and continuous nebulization.
The Aerogen® Solo Nebulizer is designed to operate in-line with standard ventilator circuits and mechanical ventilators. It operates without changing patient ventilator parameters and can be refilled without interrupting ventilation.
This submission is for a modification of the attachment process of the Aperture Plate (AP) to the Oscillator washer, both are components of the core for the Aerogen® Solo Nebulizer. The current method of attachment of the Aperture Plate to the Oscillator washer is by means of Brazing, a metal fusion process, where a copper/gold filler washer is melted in the brazing process to form the bond. The piezo is then attached using a heat cured epoxy adhesive.
The provided documentation is a 510(k) premarket notification for a medical device, specifically the Aerogen® Solo Nebulizer System. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device, rather than proving efficacy or performance against a set of predefined acceptance criteria for a novel device. As such, the document does not contain information on rigorous acceptance criteria and the detailed study design typically seen for a new device's proven performance.
However, it does present "Comparative Particle Characterization Performance" data (Table 2) which can be interpreted as the performance data for the modified device in comparison to its predicate. The "Acceptance Criteria" in this context would be the demonstration that the modified device performs similarly to the predicate device, thereby maintaining substantial equivalence.
Here's an attempt to extract the requested information based on the provided document, interpreting "acceptance criteria" as "similarity to predicate device performance" for the purpose of 510(k) clearance:
1. A table of acceptance criteria and the reported device performance
Since this is a 510(k) showing substantial equivalence, the "acceptance criteria" for the modified device are implicitly that its performance parameters should be within a similar range or deemed not clinically significant compared to the predicate device. The document explicitly states "Similar Cascade Impactor performance and NGI performance" in the comparison column, implying this is the "acceptance" based on the presented data.
| Features | Acceptance Criteria (Predicate Range @ 28 lpm) | Reported Device Performance (Modified @ 28 lpm) | Reported Device Performance (Modified @ 15 lpm - NGI) | Comparison (Achieved Acceptance) |
|---|---|---|---|---|
| Particle size (MMAD) (microns) | Albuterol: 2.90 – 3.23 Ipratropium: 3.07 – 3.42 Budesonide: 3.45 – 3.79 | Albuterol: 2.80 – 3.05 | Albuterol: 4.39 – 4.53 Ipratropium: 3.76 – 4.02 Budesonide: 4.90 – 5.01 | Similar Cascade Impactor performance and NGI performance |
| Geometric Std. Dev. (GSD) | Albuterol: 2.09 – 2.35 Ipratropium: 1.80 – 1.93 Budesonide: 1.92 – 2.14 | Albuterol: 2.26 – 2.36 | Albuterol: 2.09 – 2.16 Ipratropium: 2.28 – 2.41 Budesonide: 2.06 – 2.14 | Similar Cascade Impactor performance and NGI performance |
| Total Respirable Dose (0.0-5 microns) | Albuterol: 67.66 – 73.50 Ipratropium: 71.78 – 76.69 Budesonide: 62.32 – 66.90 | Albuterol: 70.88 – 73.94 | Albuterol: 54.42 – 56.10 Ipratropium: 59.57 – 63.06 Budesonide: 49.32 – 50.91 | Similar Cascade Impactor performance and NGI performance |
| Coarse Particle Dose (>4.7 micron) | Albuterol: 27.00 – 31.11 Ipratropium: 23.62 – 28.21 Budesonide: 32.31 – 36.12 | Albuterol: 28.73 – 32.03 | Albuterol: 46.69 – 48.78 Ipratropium: 39.87 – 43.38 Budesonide: 53.51 – 54.99 | Similar Cascade Impactor performance and NGI performance |
| Fine Particle Dose (<4.7 micron) | Albuterol: 66.33 – 72.07 Ipratropium: 68.58 – 73.84 Budesonide: 59.36 – 64.17 | Albuterol: 67.97 – 71.27 | Albuterol: 51.23 – 53.31 Ipratropium: 56.62 – 60.13 Budesonide: 45.01 – 46.49 | Similar Cascade Impactor performance and NGI performance |
| Ultra-fine Particle Dose (< 1.0 micron) | Albuterol: 5.91 – 9.93 Ipratropium: 1.85 – 4.19 Budesonide: 2.36 – 4.51 | Albuterol: 10.13 – 12.02 | Albuterol: 2.86 – 3.70 Ipratropium: 8.24 – 12.89 Budesonide: 2.78 – 3.41 | Similar Cascade Impactor performance and NGI performance |
Note: For "Total Dose (ug)", the predicate values are "N/A" and the comparison states "Additional data provided," which doesn't directly fit the "acceptance criteria" comparison. The acceptance is implied by the provision of this new data for the modified device at 15 Lpm.
2. Sample sized used for the test set and the data provenance
The document does not specify the exact sample sizes (number of nebulizers tested) used for the particle characterization testing. It refers to 95% confidence intervals, which implies statistical analysis was performed on a sample. The data provenance is not explicitly mentioned (e.g., country of origin), but it is bench testing ("Non-clinical Performance Testing") rather than patient data, and it is prospective in the sense that the tests were conducted on the modified device for the purpose of this submission.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
This document describes a 510(k) submission for a nebulizer, a physical medical device. The "ground truth" for its performance is established through objective engineering and laboratory measurements (e.g., cascade impactor, NGI) of physical parameters like particle size and dose. This is not a study involving human experts establishing ground truth for diagnostic accuracy (e.g., radiologists for medical images). Therefore, this question is not applicable in this context.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Not applicable. This is not a study involving human adjudication of results; it's a bench performance study.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This device is a nebulizer, not an AI-powered diagnostic tool for human readers.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
Not applicable. This is not a software algorithm; it's a physical device. The performance tests ("Aerosol Performance Inter- and Intra-sample variability") are analogous to standalone performance of the physical nebulizer.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
The "ground truth" for this device's performance is established by physical measurements using standardized laboratory equipment (Cascade Impactor, NGI) and methods to characterize aerosol properties. This is a form of objective, empirical measurement rather than subjective expert consensus or clinical outcomes data.
8. The sample size for the training set
Not applicable. This device is a nebulizer, not an AI/machine learning model that requires a training set. The "training" for a physical device involves its design, engineering, and manufacturing processes, which are guided by established principles, standards, and previous device iterations (like the predicate).
9. How the ground truth for the training set was established
Not applicable. As explained above, there is no "training set" in the context of a physical device like a nebulizer in the way it's understood for AI/ML.
Ask a specific question about this device
(236 days)
Sodium Chloride Inhalation Solution, USP 3% and 7%
The Sodium Chloride Inhalation Solution, USP is used in conjunction with a nebulizer. The contents of these vials are for the induction of sputum production where sputum production is indicated.
Sodium Chloride Inhalation Solution, USP 0.9%
The intended use of this sterile device is as accessories to medicinal non-ventilatory nebulizers in respiratory therapy and for tracheal irrigation or lavage.
The proposed device is a sterile, preservative-free Sodium Chloride Inhalation Solution, USP, provided in concentrations of 0.9%, 3% and 7% with a nominal fill volume of 3 mL & 5 mL (0.9%), 4 mL (3%) and 4 mL (7%) and supplied in single-use low density polyethylene (LDPE) vials.
The provided FDA 510(k) summary (K232523) describes a Sodium Chloride Inhalation Solution. This is a medical device (a drug-device combination product, specifically an accessory to a nebulizer) and not an AI/ML-powered medical device.
Therefore, the requested information regarding acceptance criteria, study design for AI model performance (including sample size, data provenance, expert ground truth, adjudication, MRMC studies, standalone performance, training set details, etc.) is not applicable to this submission.
The document focuses on demonstrating substantial equivalence to predicate devices through comparisons of technological characteristics, design verification testing, biocompatibility, and meeting USP (United States Pharmacopeia) standards for pharmaceutical solutions and manufacturing. The "Performance Data" section describes validation of the physical and chemical properties of the solution and its container, not the performance of an algorithm or AI model.
However, to answer your request based on the provided document, I will extract the relevant information regarding the device's performance acceptance criteria and study proving it meets those criteria, as described for this specific non-AI medical device.
Acceptance Criteria and Study for Sodium Chloride Inhalation Solution (K232523)
This device is not an AI/ML device, and therefore the traditional metrics and study designs associated with AI performance are not relevant. Instead, the "acceptance criteria" here refer to the product specifications and quality control parameters for a pharmaceutical solution and its container, and the "study" refers to the testing performed to demonstrate compliance with these specifications and established standards.
1. Table of Acceptance Criteria and Reported Device Performance
The document broadly states that "All results met the predetermined acceptance criteria." Specific numerical criteria and their exact corresponding reported values are not fully detailed in this summary document, as is typical for 510(k) summaries which provide a high-level overview. However, the types of criteria and the confirmation of meeting them are listed.
| Acceptance Criteria (Type of Test/Requirement) | Reported Device Performance (Summary) |
|---|---|
| Design Verification (Product Attributes) | |
| Identity | Met predetermined acceptance criteria. |
| Assay | Met predetermined acceptance criteria. |
| pH | Met predetermined acceptance criteria. |
| Endotoxin | Met predetermined acceptance criteria (absence of pyrogens). |
| Sterility | Met predetermined acceptance criteria (contents are sterile). |
| Fill Weight | Met predetermined acceptance criteria. |
| Vial Attributes (e.g., integrity) | Met predetermined acceptance criteria. |
| Vial Function (separation, cap removal, etc.) | Met predetermined acceptance criteria. |
| Biocompatibility | |
| Chemical Characterization (ISO 10993-18) | Performed; assessed extractable constituents. |
| Leachable Substances (ISO 10993-17) | Principles applied; allowable limits established. |
| Absence of Pyrogens (USP <151>) | Met the requirements for the absence of pyrogens. |
| Performance Testing (Ongoing QC/Compliance) | |
| Description | Tested, equivalent to predicate. |
| Identification (Sodium, Chloride per USP <191>) | Tested, equivalent to predicate. |
| Minimum Fill (USP <755>) | Tested, equivalent to predicate. |
| pH (USP <791>) | Tested, equivalent to predicate. |
| Osmolality (USP <785>) | Tested, equivalent to predicate. |
| Iron Content | Tested, equivalent to predicate. |
| Uniformity of Dosage Unit (USP <905>) | Tested, equivalent to predicate. |
| Container Closure Integrity (USP <1207>) | Tested, equivalent to predicate. |
| Sodium Chloride Assay (USP Monograph) | Tested, equivalent to predicate. |
| Sterility (USP <71>) | Tested, equivalent to predicate. |
| Particulate Matter (USP <789>) | Tested, equivalent to predicate. |
| Foreign Matter (USP <790>) | Tested, equivalent to predicate. |
| Bacterial Endotoxin Test (USP <85>) | Tested, equivalent to predicate. |
| Stability of Solution (3 months) | Tested. (Implies met criteria for stability) |
| Extractable study of LDPE respule/components | Tested. (Implies results were acceptable) |
| Leachable study for 3 Months stability | Tested. (Implies results were acceptable) |
| Vial Attributes and Functionality Testing | Tested. (Implies met criteria) |
| Manufacturing Process | Aseptic Processing using Blow-Fill-Seal Technology (Similar to predicate). |
| Compliance with Compendia | Complies with United States Pharmacopeia standards. |
2. Sample Size Used for the Test Set and Data Provenance
- Sample Size: The document does not specify exact numerical sample sizes for each test (e.g., "n=X vials tested for fill weight"). It generally states that "Design verification testing was conducted..." and "The Sodium Chloride Inhalation Solution... are manufactured and tested in an identical manner to the Predicate Device." This implies that standard pharmaceutical quality control and validation sample sizes were used, which are typically defined by internal QMS procedures, relevant ISO standards, and USP monographs.
- Data Provenance: The testing was conducted by the manufacturer, Mankind Pharma Limited, based in New Delhi, India, or its affiliates/contract laboratories. The data provenance is effectively the internal testing records of the manufacturer. This is retrospective in the sense that the testing has already been completed and compiled for the submission.
3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications
This is not applicable. For this type of device (a sterile saline solution), "ground truth" is established by laboratory analytical methods that measure chemical composition, sterility, pH, etc., against predefined specifications (e.g., USP monographs). Human experts are involved in reviewing and validating the test methods and results, but not in establishing a "ground truth" through consensus reading of images or clinical assessments comparable to an AI/ML study.
4. Adjudication Method for the Test Set
This is not applicable. Adjudication is relevant for subjective assessments (e.g., agreement between multiple readers on image findings). For objective chemical/physical tests, the results are quantitative and either meet or do not meet the specification; there is no "adjudication" in the sense of resolving inter-rater disagreement.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done
This is not applicable. An MRMC study is relevant for evaluating the impact of an AI system on human performance in diagnostic tasks. This device is a solution used with a nebulizer, not a diagnostic AI tool.
6. If a Standalone (i.e. algorithm only without human-in-the loop performance) was done
This is not applicable. There is no algorithm or AI component in this device. The "performance" refers to the intrinsic properties of the sodium chloride solution and its sterile container.
7. The Type of Ground Truth Used
The "ground truth" for this device's performance is established by:
- Compendial Standards: Primarily the United States Pharmacopeia (USP) monographs for Sodium Chloride Inhalation Solution and general chapters for various tests (e.g., USP <71> for Sterility, USP <85> for Bacterial Endotoxins, USP <191> for Identification, USP <755> for Minimum Fill, USP <785> for Osmolality, USP <789> for Particulate Matter, USP <790> for Foreign Matter, USP <791> for pH, USP <905> for Uniformity of Dosage Unit, USP <1207> for Container Closure Integrity).
- Internal Specifications: Derived from the device design and quality system, often based on these compendial standards and engineering requirements for the vial and its functionality.
- International Standards: e.g., ISO 10993 series for biocompatibility.
8. The Sample Size for the Training Set
This is not applicable. There is no AI model to train for this device. The "training" in manufacturing refers to process validation and optimization, not data feeding for a machine learning algorithm.
9. How the Ground Truth for the Training Set Was Established
This is not applicable, as there is no AI training set.
Ask a specific question about this device
Page 1 of 30