510(k) Data Aggregation

    K Number
    K243689

    Validate with FDA (Live)

    Device Name
    AVIEW
    Date Cleared
    2025-03-19

    (110 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    AVIEW provides CT values for pulmonary tissue from CT thoracic and cardiac datasets. This software can be used to support the physician providing quantitative analysis of CT images by image segmentation of sub-structures in the lung, lobe, airways, fissures completeness, cardiac, density evaluation, and reporting tools. AVIEW is also used to store, transfer, inquire and display CT data set on-premises and as a cloud environment to allow users to connect by various environments such as mobile devices and Chrome browsers. Converts the sharp kernel to soft kernel for quantitative analysis of segmenting low attenuation areas of the lung Characterizing nodules in the lung in a single study or over the time course of several thoracic studies. Characterizations include nodule type, location of the nodule, and measurements such as size (major axis), estimated effective diameter from the volume of the volume of the nodule, Mean HU(the average value of the CT pixel inside the nodule in HU), Minimum HU, Max HU, mass(mass calculated from the CT pixel value), and volumetric measures(Solid major: length of the longest diameter measure in 3D for a solid portion of the nodule. Solid 2nd Maior: The size of the longest diameter of the solid part, measured in sections perpendicular to the Major axis of the solid portion of the nodule), VDT (Volume doubling time), and Lung-RADS (classification proposed to aid with findings.)). The system automatically performs the measurement, allowing lung nodules and measurements to be displayed and, integrate with FDA certified AVIEW Lung Nodule CAD (Computer aided detection) (K221592). It also provides the Agatston score, volume score, and mass score by the whole and each artery by segmenting four main arteries (right coronary artery, left main coronary, left anterior descending, and left circumflex artery). Based on the calcium score provides CAC risk based on age and gender The device is indicated for adult patients only.

    Device Description

    The AVIEW is a software product that can be installed on a PC. It shows images taken with the interface from various storage devices using DICOM 3.0, the digital image and communication standard in medicine. It also offers functions such as reading, manipulation, analyzing, post-processing, saving, and sending images by using software tools. And is intended for use as a quantitative analysis of CT scanning. It provides the following features such as segmentation of lung, fissure completeness, semi-automatic nodule management, maximal plane measures and volumetric measures, automatic nodule detection by integration with 3rd party CAD. It also provides the Brocks model, which calculates the malignancy score based on numerical or Boolean inputs. Follow-up support with automated nodule matching and automatically categorize Lung-RADS score, which is a quality assurance tool designed to standardize lung cancer screening and management recommendations that are based on type, size, size change, and other findings that are reported. It also provides a calcium score by automatically analyzing coronary arteries.

    AI/ML Overview

    The provided text is a 510(k) premarket notification letter and summary for a medical device called "AVIEW." This document primarily asserts substantial equivalence to a predicate device and notes general software changes rather than providing detailed acceptance criteria and study results for specific performance metrics that would typically be found in performance study reports.

    Specifically, the document states: "This Medical device is not new; therefore, a clinical study was not considered necessary prior to release. Additionally, there was no clinical testing required to support the medical device as the indications for use is equivalent to the substantial equivalence of the device is supported by the non-clinical testing." This means that the submission does not include information about a standalone or MRMC study designed to prove the device meets specific performance acceptance criteria for its analytical functions.

    Therefore, I cannot provide the requested information from the given text as the detailed performance study data is not present. The document focuses on regulatory equivalence based on technological characteristics and intended use being similar to a predicate device, rather than providing new performance study data.