    Device Name
    Endo Motor
    Date Cleared
    2023-05-18

    (422 days)

    Product Code
    Regulation Number
    872.4200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    C-SMART-I PRO, C-SMART-I PILOT, C-SMART-MINI AP:
    The Endo Motor device is an endodontic treatment motorized handpiece with root canal measurement capability. It can be used to enlarge the canals while monitoring the position of the canal. It can be used as a low-speed motorized handpiece and device for measuring canal length. This device must only be used in hospital environments, clinics or dental offices by qualified dental personnel.

    C-Smart-mini:
    The Endo Motor device is an endodontic treatment motorized handpiece. It can be used to enlarge canals. It can be used as a low-speed motorized handpiece. This device must only be used in hospital environments, clinics or dental offices by qualified dental personnel.

    Device Description

    C-SMART-I PRO: The Endo Motor device C-SMART-I PRO is a low-speed rotating oral equipment mainly used for root canal preparation and root canal measurement. The product is a portable device powered by built-in lithium batteries and charged by the adapter. LCD displays parameters such as speed, torque, working mode, apex position, etc. Users can also set and modify by keys, and provide design of factory initialization, calibration and functional check of the apex locator. The Endo Motor device is an endodontic treatment motorized handpiece with root canal measurement capability. It can be used to enlarge the canals while monitoring the position of the file tip inside the canal. It can be used as a low-speed motorized handpiece and device for measuring canal length. This device must only be used in hospital environments, clinics or dental offices by qualified dental personnel. The Endo Motor device C-SMART-I PRO is intended to be sterilized prior to use. The material composition of root canal files that can be used with the Endo Motor device C-SMART-I PRO is Nickel titanium (NiTi). These files are not included in the submission. There are three working modes as: M1: Apex locator only. M2: Motor only. M3: (Dual mode) Motor with apex location function.

    C-SMART-I PILOT: The Endo Motor device C-SMART-I PILOT is a low-speed rotating oral equipment mainly used for root canal preparation and root canal measurement. The product is a portable device powered by built-in lithium batteries and charged by the adapter. LCD displays parameters such as speed, torque, working mode, apex position, etc. Users can also set and modify by keys, and provide design of function check, calibration, factory reset and can connect handpiece to control unit via Bluetooth. The Endo Motor device is an endodontic treatment motorized handpiece with root canal measurement capability. It can be used to enlarge the canals while monitoring the position of the file tip inside the canal. It can be used as a low-speed motorized handpiece and device for measuring canal length. This device must only be used in hospital environments, clinics or dental offices by qualified dental personnel. The Endo Motor device C-SMART-I PILOT is intended to be sterilized prior to use. The material composition of root canal files that can be used with the Endo Motor device C-SMART-I PILOT is Nickel titanium (NiTi). These files are not included in the submission. There are three working modes as: Endo motor mode: root canal preparation. Apex locator mode: root canal length measurement. Multi-function mode: undertake root canal measurement and preparation.

    C-SMART-MINI AP: The Endo Moto device C-SMART-MINI AP is a low-speed rotating oral equipment mainly used for root canal preparation and root canal measurement. The product is a portable device powered by built-in lithium batteries and charged by the adapter. LCD displays parameters such as speed, torque, apex position, etc. Users can also set and modify by keys, and provide design of functional check, calibration, set dominant hand and factory reset. The Endo Motor device is an endodontic treatment motorized handpiece with root canal measurement capability. It can be used to enlarge the canals while monitoring the position of the file tip inside the canal. It can be used as a low-speed motorized handpiece and device for measuring canal length. This device must only be used in hospital environments, clinics or dental offices by qualified dental personnel. The Endo Motor device C-SMART-MINI AP is intended to be sterilized prior to use. The material composition of root canal files that can be used with the Endo Motor device C-SMART-MINI AP is Nickel titanium (NiTi). These files are not included in the submission. There are three working modes as: Endo motor: Prepare the root canal, without apex locator function. Apex Locator: Measure the length of the root canal, without motor function. Multi-function: Measuring the length while root canal preparation.

    C-Smart-mini: The Endo Motors device C-Smart-mini is a low-speed rotating oral equipment mainly used for root canal preparation. The product is a portable device powered by built-in lithium batteries and charged by the adapter. LCD displays parameters such as speed, torque, rotary files program, etc. Users can also set and modify by keys, and provide design of calibration and screen display for right- or left-handed user. The Endo Motor device is an endodontic treatment motorized handpiece. It can be used to enlarge the canals. It can be used as a low-speed motorized handpiece. This device must only be used in hospital environments, clinics or dental offices by qualified dental personnel. The Endo Motor device C-Smart-mini is intended to be sterilized prior to use. The material composition of root canal files that can be used with the Endo Motor device C-Smart-mini is Nickel titanium (NiTi). These files are not included in the submission.

    AI/ML Overview

    The provided text does not describe the acceptance criteria and the study that proves the device meets the acceptance criteria. Instead, it is a 510(k) premarket notification for an "Endo Motor" device, outlining its features and comparing it to a predicate device to claim substantial equivalence.

    While the document references "Accuracy Testing (Internal test methods to demonstrate the apex position measurement accuracy of ±0.5mm)" among its non-clinical tests, and explicitly states "No clinical study is included in this submission," it does not provide the detailed information requested regarding acceptance criteria and a study proving those criteria are met for the device's performance.

    Therefore, I cannot extract the requested information from the provided text.