Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K202031

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2021-05-06

    (288 days)

    Product Code
    Regulation Number
    890.5850
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Talent-Pro™ Electromagnetic Stimulator is intended to be used under medical supervision for adjunctive therapy for the treatment of medical diseases and conditions.

    The Talent-Pro™ Electromagnetic Stimulator is indicated for use in stimulating neuromuscular tissue for bulk muscle excitation in the legs or arms for rehabilitative purposes.

    Indications for Use for Muscle Stimulators:

    • Relaxation of muscle spasms
    • Prevention or retardation of disuse atrophy
    • Increasing local blood circulation
    • Muscle re-education
    • Immediate post-surgical stimulation of calf muscles to prevent venous thrombosis
    • Maintaining or increasing range of motion
    Device Description

    The Talent-Pro Electromagnetic Stimulator is indicated for use in stimulating neuromuscular tissue for bulk muscle excitation in the legs or arms for rehabilitative purposes, prevention or retardation of disuse atrophy. Talent-Pro Electromagnetic Stimulator consists of the Main body, Transducer for magnetic stimulation

    AI/ML Overview

    The provided text describes the Talent-Pro Electromagnetic Stimulator, a device for neuromuscular tissue stimulation, and assesses its substantial equivalence to a predicate device (HPM-6000, K160992) for FDA 510(k) clearance. However, the document does not contain acceptance criteria or study results for a device that relies on artificial intelligence (AI) or machine learning.

    The document outlines performance and safety data relevant to an electromagnetic stimulator, which is a physical device, not an AI/ML algorithm. Therefore, I cannot provide the requested information regarding AI/ML acceptance criteria or studies proving device performance based on the input document.

    The "Safety & Performance Data" section primarily addresses:

    • Biocompatibility Testing: Ensuring the materials are safe for human contact.
    • Design Verification and Validation Testing: Verifying the device meets predefined safety and performance requirements (e.g., magnetic field output, intensity control, pulse width/frequency, stability, safety devices, simultaneous operation prevention).
    • Electrical Safety and Performance Testing: Compliance with IEC standards.
    • Shipping Validation: Ensuring the device withstands transport.

    These tests are standard for medical hardware devices and do not involve AI/ML performance metrics such as AUC, sensitivity, specificity, or human-in-the-loop studies for AI assistance.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1