510(k) Data Aggregation

    K Number
    K133113

    Validate with FDA (Live)

    Date Cleared
    2013-12-26

    (87 days)

    Product Code
    Regulation Number
    880.2910
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    TF1265, TF1267 Forehead Thermometer is an electronic thermometer using an infrared sensor to detect human body temperature fro the surface of human skin without contact. It is for use by people of all ages in the homecare environment.

    Device Description

    The Forehead Thermometer TF1265, TF1267 is characterized by measuring human body temperature from the surface of human skin. It utilizes infrared technology to measure infrared energy emitted from the skin surface when making a temperature measurement.

    AI/ML Overview

    This document describes the regulatory submission for the KINGTECH Forehead Thermometer, Models TF1265 and TF1267. It is a 510(k) summary, indicating that the device is seeking clearance based on substantial equivalence to a legally marketed predicate device.

    Here's the breakdown of the requested information:

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided document does not explicitly state specific numerical acceptance criteria for clinical performance (e.g., accuracy against a gold standard) for the subject device. Instead, it relies on a claim of "entire identical specifications" and a direct comparison to a predicate device, K122221, "Nexus IR30 Thermometer, Model: TD-1265."

    The performance tests mentioned are safety and electromagnetic compatibility (EMC) standards:

    Acceptance Criteria (Standard)Reported Device Performance (Compliance)
    IEC 60601-1 (Medical electrical equipment Part 1. General requirements for safety, 2005)Compliant
    EN/IEC 60601-1-2 (Medical electrical equipment, Part 2. Electromagnetic compatibility - Requirements and tests, 2007)Compliant
    EN12470 (Specific to clinical thermometers)Compliant
    ASTME 1965-98 (Standard Specification for Clinical Thermometers)Compliant
    ASTM E1112-00 (Standard Specification for Electronic Thermometers for Intermittent Determination of Patient Temperature)Compliant

    Note: The document states, "This 510k submission only need change the application name of the predicate K122221 from 'Nexus IR30 Thermometer, TD-1265' to 'KINGTECH Forehead Thermometer, TF1265' there is the entire identical specifications and only need to separate into different 510k." This implies that the KINGTECH device's clinical performance is assumed to be identical to the predicate device's performance, as they share the same specifications. However, the performance metrics of the predicate device are not included in this summary.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not provide information on a specific clinical test set for the KINGTECH device, nor does it specify sample size or data provenance. It explicitly states under "Clinical Tests:" followed by a blank entry, suggesting no new clinical testing was conducted for this 510(k) submission. Instead, the submission relies on the "entire identical specifications" to the predicate device.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable or provided as no specific clinical test set for the KINGTECH device is described. The device's substantial equivalence is based on its identical specifications to the predicate device, not on new clinical data with an independent ground truth.

    4. Adjudication Method for the Test Set

    This information is not applicable or provided as no specific clinical test set requiring adjudication for the KINGTECH device is described.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size of Human Readers Improvement with AI vs. Without AI Assistance

    This information is not applicable or provided. The device is an infrared thermometer, not an AI-assisted diagnostic tool requiring MRMC studies for human reader performance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This information is not applicable or provided. The device is a thermometer, not an algorithm. Its performance is measured directly, though the document defers to the predicate device's performance characteristics.

    7. The Type of Ground Truth Used

    This information is not applicable or provided for the subject device. For a thermometer, the "ground truth" for reported temperature accuracy would typically be a highly accurate reference thermometer measurement. However, since no new clinical testing is presented, the ground truth methodology for the predicate device is not detailed here.

    8. The Sample Size for the Training Set

    This information is not applicable or provided. The device is a hardware product (thermometer) and not a machine learning algorithm that requires a training set in the typical sense.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable or provided. Refer to point 8.