Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K102948

    Validate with FDA (Live)

    Date Cleared
    2011-04-01

    (178 days)

    Product Code
    Regulation Number
    870.1340
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TorFlex™ Transseptal Guiding Sheath is used for the percutaneous introduction of various types of cardiovascular catheters to all heart chambers, including the left atrium via transseptal perforation / puncture.

    Device Description

    The TorFlex™ Transseptal Guiding Sheath kit consists of three components: a sheath, a dilator, and a J-tipped guidewire. The TorFlex™ Transseptal Guiding Sheath is designed for safe and easy catheterization and angiography of specific heart chambers and locations. The sheath provides superior torque control and is flexible. The radiopaque tip maximizes visualization of the sheath during manipulation. The dilator provides support for the sheath and has a tapered tip.

    AI/ML Overview

    This document describes the premarket notification (510(k)) for the TorFlex™ Transseptal Guiding Sheath, a medical device. It does not pertain to an AI/ML powered device, therefore many of the requested categories (such as sample size, number of experts for ground truth, adjudication methods, multi-reader multi-case studies, and standalone performance) are not applicable.

    Here's the relevant information extracted and structured to the extent possible for a non-AI device submission:

    1. Table of Acceptance Criteria and Reported Device Performance

    Test CategoryAcceptance Criteria (Implied)Reported Device Performance
    BiocompatibilitySafe for intended usePassed all tests (Cytotoxicity, Sensitization, Irritation/Intracutaneous Reactivity, Systemic Toxicity (Acute), Hemocompatibility, Pyrogenecity)
    Mechanical TestingAble to withstand physical stresses without failurePassed all tests (Torque transmission + Strength of union -Torque test, Flow rate measurement, Three point bend test, Freedom from liquid/air leaking through hemostasis valves + valve integrity, Freedom from liquid/air leakage, Strength of union-Pull test, Valve insertion force, Tip transition, Snap fit)
    General PhysicalAcceptable surface quality and corrosion resistancePassed evaluation for Surface Defects, Corrosion Resistance
    Bench TestingCompatible with 8F devicesDemonstrated compatibility with 8F devices
    SterilizationSterilized according to relevant standards; compliant ETO residueValidated as per ANSI/AAMI/ISO 11135-1 and FDA Guideline on Validation of LAL Test; ETO residue levels compliant with ISO 10993-7
    PackagingValidated for integrityValidated in accordance with ANSI/AAMI/ISO 11607

    2. Sample Size Used for the Test Set and Data Provenance

    This is a device for physical intervention, not an AI/ML algorithm that processes data. Therefore, the concept of a "test set" with data provenance (country of origin, retrospective/prospective) is not applicable. The device undergoes laboratory and bench testing.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. Ground truth for device performance is established through defined engineering and biological testing standards, not expert consensus on data interpretation.

    4. Adjudication Method for the Test Set

    Not applicable. Testing involves objective measurements against established engineering and biological standards.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI-powered device, and no human reader studies are described.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical medical device, not an algorithm.

    7. The Type of Ground Truth Used

    The ground truth for this device's performance is established through:

    • Compliance with recognized industry standards (e.g., ISO, AAMI) for biocompatibility, sterilization, and packaging.
    • Engineering specifications and test methodologies for mechanical performance, flow rates, and physical characteristics.
    • Safety thresholds for material residues (e.g., Ethylene Oxide).

    8. The Sample Size for the Training Set

    Not applicable. This is a physical device, and the concept of a "training set" is irrelevant.

    9. How the Ground Truth for the Training Set was Established

    Not applicable. There is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1