510(k) Data Aggregation

    K Number
    K241276

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-05-20

    (14 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When used for posterior pedicle screw or posterior non-pedicle fixation, the Innovasis Vector™ Pedicle Screw System is intended to provide immobilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative disc disease (DDD - defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), spinal stenosis, spinal deformities (i.e. scoliosis, kyphosis, and/or lordosis), fracture, dislocation, failed previous fusion (pseudoarthrosis), and/or tumor resection.

    When used for posterior non-cervical screw fixation in pediatric patients, the Innovasis Vector Pedicle Screw System is indicated as an adjunct to freat adolescent idiopathic scoliosis (AIS). Additionally, the Innovasis Vector Pedicle Screw System is intended to treat pediatric patients diagnosed with the following conditions: spondylolisthesis/spondylolysis, and fracture caused by tumor and/or trauma. Pediatric pedicle screw fixation is limited to a posterior approach and is intended to be used with autograft and/or allograft.

    Device Description

    The Vector" Pedicle Screw System is a thoracolumbar system composed of polyaxial pedicle screws, rods, hooks, rod connectors, locking caps, lateral connectors, and transverse cross links. The system is designed with multiple options to address complex, multi-level deformity cases and accommodate various patient anatomies. The Vector Pedicle Screw System is also designed to facilitate percutaneous screw and rod placement via Minimally Invasive Surgery (MIS). The cannulated pedicle screws and extended reduction tabs allow for rod placement and minimal tissue disruption. The system was designed to minimize the number and complexity of procedural steps. Implants are manufactured from Titanium (Ti-6Al-4V ELI) per ASTM F136 or Cobalt Crome (CoCr) per ASTM F562.

    AI/ML Overview

    This is a 510(k) summary for the Vector™ Pedicle Screw System. The document focuses on demonstrating substantial equivalence to predicate devices based on technological characteristics and mechanical performance. It does NOT describe a study that proves the device meets specific acceptance criteria in terms of clinical performance or diagnostic accuracy. Therefore, most of the requested information cannot be extracted directly from this document.

    Here's a breakdown of what can be extracted and a clear statement of what cannot:

    Information that can be extracted:

    1. A table of acceptance criteria and the reported device performance:

      • Acceptance Criteria (Mechanical Performance): The document states that "All testing performed demonstrated substantially equivalent mechanical performance to legally marketed predicate devices." This implies the acceptance criteria were to be substantially equivalent to the predicates in the tested mechanical properties.
      • Reported Device Performance:
        • Static and Dynamic Compression Bending per ASTM F1717
        • Static Torsion per ASTM F1717
        • Static Axial and Torsional Grip per ASTM F1798
        • The performance for these tests was deemed "substantially equivalent" to predicate devices. Specific quantitative values are not provided in this summary.
    2. Sample sized for the test set and the data provenance: Not applicable. This document refers to mechanical testing of components, not clinical data from a test set of patients. The provenance would be the test labs where the mechanical tests were performed.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. This pertains to clinical or diagnostic accuracy studies, which were not conducted or reported here.

    4. Adjudication method for the test set: Not applicable.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This device is a pedicle screw system, not an AI diagnostic device.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done: Not applicable.

    7. The type of ground truth used: For the mechanical tests, the ground truth was the established standards and performance of the predicate devices.

    8. The sample size for the training set: Not applicable. This refers to mechanical testing, not a training set for an AI model.

    9. How the ground truth for the training set was established: Not applicable.


    Summary of what the document addresses vs. what it does not:

    This FDA 510(k) summary is for a physical medical device (pedicle screw system), not an AI/software device. The "study" referenced is a series of non-clinical (mechanical) tests to establish substantial equivalence with predicate devices, as opposed to a clinical study demonstrating diagnostic accuracy or clinical effectiveness in patients.

    Therefore, the detailed questions about ground truth, expert adjudication, test set/training set sizes, and MRMC studies related to human reader performance with or without AI are not applicable to this document. The document explicitly states: "N/A - no clinical data were necessary."

    Ask a Question

    Ask a specific question about this device

    K Number
    K213421

    Validate with FDA (Live)

    Date Cleared
    2021-11-19

    (30 days)

    Product Code
    Regulation Number
    888.3040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vector Hammertoe Correction System is indicated for the fixation of osteotomies and reconstruction of the lesser toes following correction procedures for hammertoe, claw toe, and mallet toe.

    Device Description

    The Vector Hammertoe Correction System is comprised of a sterile PEEK (polyetheretherketone) HA (hydroxyapatite) fixation device. The implants are offered in Ø3.00mm, Ø3.50mm and Ø4.00mm and in 0° angle. The system has K-wires, drill, taps, implant inserters, and sizers manufactured from medical grade stainless steel.

    AI/ML Overview

    The provided text does not contain information about the acceptance criteria and the study that proves the device meets the acceptance criteria, as it relates to performance metrics of a device, particularly an AI/imaging device. The document is an FDA 510(k) clearance letter for a medical device called the "Vector® Hammertoe Correction System," which is a bone fixation system, not an imaging or AI-driven diagnostic device.

    Therefore, I cannot provide the requested information from the given text.

    The document discusses:

    • Device Name: Vector® Hammertoe Correction System
    • Regulation Number: 21 CFR 888.3040 (Smooth Or Threaded Metallic Bone Fixation Fastener)
    • Regulatory Class: Class II
    • Indications for Use: Fixation of osteotomies and reconstruction of the lesser toes following correction procedures for hammertoe, claw toe, and mallet toe.
    • Device Description: Sterile PEEK (polyetheretherketone) HA (hydroxyapatite) fixation device, K-wires, drill, taps, implant inserters, and sizers manufactured from medical grade stainless steel.
    • Predicate Devices: K201850 (Nvision Biomedical's Vector Hammertoe Correction System), K183055 (Nvision Biomedical's Vector Hammertoe Correction System), and K193645 (Nvision Biomedical's nva, nvt).
    • Non-Clinical Testing: Primarily engineering analysis comparing device characteristics (materials, intended use, cleaning, sterilization) to predicate devices. It states no FDA performance standards have been established for this device and that the results indicate substantial equivalence. The key modification mentioned is the addition of steam sterilization as an alternative method.

    None of the information required for explaining acceptance criteria for an AI/imaging device, such as sample sizes for test and training sets, expert qualifications, adjudication methods, MRMC studies, standalone performance, or ground truth establishment, is present in this regulatory document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201850

    Validate with FDA (Live)

    Date Cleared
    2020-08-04

    (29 days)

    Product Code
    Regulation Number
    888.3040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vector Hammertoe Correction System is indicated for the fixation of osteotomies and reconstruction of the lesser toes following correction procedures for hammertoe, claw toe, and mallet toe.

    Device Description

    The VECTOR Hammertoe Correction System is comprised of a sterile PEEK (polyetheretherketone) HA (hydroxyapatite) fixation device. The implants are offered in Ø3.0mm (cannulated), Ø3.50mm (cannulated and non-cannulated) and Ø4.00mm (cannulated and non-cannulated) and in 0° angle. The system has K-wires, drill, taps, implant inserters, and sizers manufactured from medical grade stainless steel.

    AI/ML Overview

    The provided text is a 510(k) summary for the VECTOR™ Hammertoe Correction System. It describes the device, its indications for use, and its equivalence to predicate devices, primarily through engineering analysis. This document does not contain information about an AI/ML powered device, nor does it present acceptance criteria or a study proving device performance in the context of AI/ML.

    Therefore, I cannot fulfill your request for:

    1. A table of acceptance criteria and the reported device performance
    2. Sample size used for the test set and data provenance
    3. Number of experts used to establish ground truth and their qualifications
    4. Adjudication method
    5. MRMC comparative effectiveness study results
    6. Standalone (algorithm only) performance data
    7. Type of ground truth used
    8. Sample size for the training set
    9. How ground truth for the training set was established

    The document explicitly states: "No FDA performance standards have been established for the Vector Hammertoe Correction System. The following was performed to demonstrate safety per methods of the previous submission: Engineering Analysis comparison of mechanical performance characteristics." This indicates that the safety and effectiveness were demonstrated through mechanical performance characteristics engineering analysis and comparison to predicates, not through clinical or AI/ML performance studies with human readers or AI algorithms.

    Ask a Question

    Ask a specific question about this device

    K Number
    K183055

    Validate with FDA (Live)

    Date Cleared
    2019-02-19

    (109 days)

    Product Code
    Regulation Number
    888.3040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vector Hammertoe Correction System is indicated for the fixation of osteotomies and reconstruction of the lesser toes following correction procedures for hammertoe, claw toe, and mallet toe.

    Device Description

    The VECTOR Hammertoe Correction System is comprised of a sterile PEEK (polyetheretherketone) HA (hydroxyapatite) fixation device. The implants are offered in Ø3.50mm and Ø4.00mm and in 0° angle. The system has K-wires, drill, taps, implant inserters, and sizers manufactured from medical grade stainless steel.

    AI/ML Overview

    The VECTOR Hammertoe Correction System is a medical device designed for the fixation of osteotomies and reconstruction of lesser toes following correction procedures for hammertoe, claw toe, and mallet toe. The provided text describes the regulatory filing for this device, not a study evaluating its performance against specific acceptance criteria. Therefore, most of the requested information cannot be extracted directly from this document.

    However, based on the "SUMMARY OF NON-CLINICAL TESTING" section, we can infer the types of tests performed to demonstrate safety and equivalence to predicate devices, which serve as the implicit acceptance criteria for this type of regulatory submission.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Inferred from testing performed)Reported Device Performance
    Mechanical Performance (per ASTM F543):The results of these tests, along with engineering analysis, indicate that the VECTOR Hammertoe Correction System is substantially equivalent to the predicate devices. This implies that the device met the performance requirements/standards implied by ASTM F543 for these mechanical properties, demonstrating comparable or superior performance to the predicate devices.
    - Torsion
    - Driving Torque
    - Axial Pullout
    Mechanical Performance (additional):
    - Static Bending
    - Dynamic Bending
    Biocompatibility/Sterility (per Bacterial Endotoxins limits):The device has been tested (LAL testing) to meet recommended Bacterial Endotoxins limits of 20 EU/device. This indicates the device passed the specified endotoxin limits.

    2. Sample size used for the test set and the data provenance
    The document does not specify the sample size for individual tests (e.g., number of implants tested for torsion, pullout, etc.). It describes non-clinical laboratory testing. The data provenance is from laboratory testing conducted by the manufacturer, Nvision Biomedical Technologies, LLC. Since these are non-clinical (mechanical and biological) tests, "country of origin of the data" and "retrospective or prospective" are not directly applicable in the same way they would be for clinical studies with human subjects.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
    Not applicable. This is a non-clinical study involving mechanical and biocompatibility testing, not human expert evaluation of clinical images or diagnoses. The "ground truth" here is established by the specifications of the ASTM standards and regulatory limits (e.g., endotoxin levels).

    4. Adjudication method for the test set
    Not applicable. There was no expert adjudication process as this was non-clinical laboratory testing.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    Not applicable. This document describes the regulatory filing for a medical fixation device, not an AI-assisted diagnostic or imaging device. Therefore, no MRMC study, human reader improvement, or AI assistance is relevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
    Not applicable. This is not an algorithmic or AI-based device.

    7. The type of ground truth used
    The "ground truth" for the non-clinical tests is based on:

    • Engineering specifications and recognized consensus standards: Specifically ASTM F543, which outlines standard test methods for metallic medical bone screws.
    • Regulatory limits for biocompatibility: Recommended Bacterial Endotoxins limits (20 EU/device).
    • Comparison to predicate devices: The "substantially equivalent" determination implies that the test results met or exceeded the performance characteristics of the predicate devices.

    8. The sample size for the training set
    Not applicable. This is not an AI/machine learning device that requires a training set.

    9. How the ground truth for the training set was established
    Not applicable. As above, there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K143652

    Validate with FDA (Live)

    Date Cleared
    2015-02-26

    (65 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vector™ PTA Balloon Dilatation Catheter is recommended for Percutaneous Transluminal Angioplasty (PTA) of the femoral, iliac, popliteal, and renal arteries and for the treatment of obstructive lesions of native or synthetic arterio-venous dialysis fistulae.

    The Vector" Catheter is not indicated for use in the coronary arteries or for placement of or post dilatation of stents.

    Device Description

    The Vector™ PTA Balloon Dilatation Catheter is a high pressure, non-compliant balloon catheter. It is a coaxial dual lumen over-the-wire balloon dilatation catheter. The central lumen accommodates guide wires up to the 0.035 inches in diameter while the outer lumen is the inflation lumen for the balloon.

    The balloon is a high pressure composite balloon with radio-opaque marker bands to help visualize the balloon placement within the vasculature during both placement and inflation. The balloon's rated burst pressure is 30 atm.

    AI/ML Overview

    The provided document is a 510(k) summary for a medical device called the Vector™ PTA Balloon Dilatation Catheter (K143652). It outlines the device's technical characteristics, intended use, and a summary of performance testing to establish substantial equivalence to a predicate device.

    Here's an analysis to extract the requested information:

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria / Performance SpecificationReported Device Performance
    Rated Burst PressureMet specifications
    Balloon ComplianceMet specifications
    Balloon Diameter SizingMet specifications
    Inflation/Deflation TimesMet specifications
    Repeat InflationMet specifications
    Removal/Refold & ReuseMet specifications
    Flexibility / KinkMet specifications
    Crossing ProfileMet specifications
    Balloon Protector RemovalMet specifications
    Guidewire/Introducer CompatibilityMet specifications
    Tensile StrengthMet specifications
    Visibility under Fluoro-imagingMet specifications
    Torque StrengthMet specifications
    Catheter LeakMet specifications
    Sterilization (SAL 10-6)Achieved via Ethylene Oxide
    Biocompatibility (ISO 10993-1)Met requirements

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document does not explicitly state the specific sample sizes used for each individual test. It mentions "All devices met the performance specifications" implying that a sufficient number of devices were tested for each performance characteristic. The data provenance is not specified, but the testing would typically be internal bench testing conducted by the manufacturer. It is not a clinical study, so concepts like country of origin or retrospective/prospective don't apply in the same way.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This document describes bench testing of a device's physical and functional properties, not a diagnostic or AI device that relies on expert interpretation to establish "ground truth." Therefore, this question is not applicable. The "ground truth" for these tests are the engineering specifications and established test methods.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This question is not applicable as the document describes bench testing of a physical device, not an assessment requiring expert adjudication of clinical outcomes or diagnostic interpretations.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This question is not applicable. This is a 510(k) submission for a physical medical device (balloon catheter), not an AI/CAD diagnostic device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This question is not applicable. This is a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the performance tests described (Rated Burst Pressure, Balloon Compliance, etc.), the "ground truth" is defined by the engineering specifications, industry standards, and established test methodologies. For example, the rated burst pressure is a design specification that the device must meet or exceed. There is no expert consensus, pathology, or outcomes data involved in establishing "ground truth" for these types of bench tests.

    8. The sample size for the training set

    This question is not applicable. This is a physical medical device, not a machine learning model, so there is no "training set."

    9. How the ground truth for the training set was established

    This question is not applicable. As there is no training set, there is no ground truth for it.

    Ask a Question

    Ask a specific question about this device

    K Number
    K141051

    Validate with FDA (Live)

    Date Cleared
    2014-07-07

    (74 days)

    Product Code
    Regulation Number
    876.5540
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Arrow VectorFlow Antegrade Chronic Hemodialysis Catheter is indicated for use in attaining long-term vascular access for hemodialysis and apheresis. The Arrow VectorFlow Antegrade Chronic Hemodialysis Catheter is inserted percutaneously and is preferentially placed into the internal jugular (II) vein. Alternately, this catheter may be inserted into the subclavian vein although the jugular vein is the preferred site. Catheters greater than 40 cm are intended for femoral vein insertion. The Arrow VectorFlow Antegrade Chronic Hemodialysis Catheter is intended for use in adult patients.

    The Arrow VectorFlow Retrograde Chronic Hemodialysis Catheter is indicated for use in attaining long-term vascular access for hemodialysis and apheresis. The Arrow VectorFlow Retrograde Chronic Hemodialysis Catheter is inserted percutaneously and is preferentially placed into the internal jugular (IJ) vein. Alternately, this catheter may be inserted into the subclavian vein although the jugular vein is the preferred site. Catheters greater than 40 cm are intended for femoral vein insertion. The Arrow VectorFlow Retrograde Chronic Hemodialysis Catheter is intended for use in adult patients.

    The Arrow VectorFlow Retrograde Replacement Hub Set is indicated for use in the replacement of a Arrow VectorFlow Retrograde hub connection assembly that has been damaged.

    Device Description

    The Arrow VectorFlow Antegrade Chronic Hemodialysis Catheter (herein referred to as the proposed VFA catheter) and the Arrow VectorFlow Retrograde Chronic Hemodialysis Catheter (herein referred to as the proposed VFR catheter) are long-term, single use catheters designed to provide access to the central venous system in a healthcare facility environment. The VFA catheter is a one piece catheter, two lumen, 15 French symmetrical-tipped catheter designed for antegrade placement. The VFR catheter is two-piece, two-lumen, 15 Fr, symmetrical tipped catheter designed for retrograde placement. The VFA and VFR catheters are available in multiple lengths. The Arrow VectorFlow Retrograde Replacement Hub Set (herein referred to as the proposed Hub Set) is sold separately to perform a repair of the VFR, replacing cracked or broken luer connectors, clamps, and/or damaged extension lines.

    The VFA and VFR catheters and Hub Set will be packaged sterile with various components to facilitate insertion.

    AI/ML Overview

    The provided text describes a 510(k) summary for Arrow VectorFlow catheters and a replacement hub set. This document is a premarket notification for a medical device seeking substantial equivalence to existing predicate devices, not a study describing the performance of an AI/ML-driven device with acceptance criteria.

    Therefore, I cannot extract the information required to populate the fields you specified (e.g., acceptance criteria for an AI/ML device, sample size for test sets, number of experts for ground truth, MRMC study, training set details) because this document is for a physical medical device (hemodialysis catheters) and does not involve AI/ML.

    The "Nonclinical Testing" section mentions "Bench testing" and compliance with ISO standards, which are typical for physical medical devices to demonstrate safety and performance. The "Clinical Data" section explicitly states, "Clinical performance data was not used to determine substantial equivalence."

    Key takeaway: This document does not describe an AI/ML device or its performance evaluation in the context of your request.

    Ask a Question

    Ask a specific question about this device

    K Number
    K131329

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2013-06-06

    (29 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vector 4 " PTA Balloon Dilatation Catheter is recommended for Percutaneous Transluminal Angioplasty (PTA) of the femoral, iliac, popliteal, and renal arteries and for the treatment of obstructive lesions of native or synthetic arterio-venous dialysis fistulae.

    The Vector Catheter is not indicated for use in the coronary arteries or for placement of or post dilatation of stents.

    Device Description

    The Vector" PTA Balloon Catheter is a high pressure, non-compliant balloon catheter with a radio-opaque coating on the balloon. The radio-opaque coating on the working length of the balloon minimizes or eliminates the need for using contrast solution to inflate the balloon. The radio-opaque coating delineates the working length of the balloon and provides continuous fluoroscopic visibility during balloon placement. Saline may be used to inflate the balloon without affecting visualization. Contrast mixture may be used at the discretion of · the physician.

    It is a coaxial dual lumen over the wire balloon dilatation catheter. The central lumen, accommodates guide wires up to 0.035 inches in diameter while the outer lumen is the inflation'lument or the balloon. The catheter includes an atraumatic tip to ease advancement of the catheter, to and through the stenosis. The distal tip is visible under fluoroscopy.

    The balloon is a high pressure composite balloon with a radio-opaque coating on the working length to help visualize placement within the lesion during both placement and inflation; without the use of contrast. The balloon's rated burst pressure is 30 atm.

    The catheter is supplied sterile and non-pyrogenic. Different balloon sizes (5 mm to 10 mm) and catheter lengths (50 to 135 cm) are available. The proximal end of the catheter contains a hub with two female luer locks.

    The device is compatible with 6-7F introducers. The introducer compatibility for each device size is listed on the device label itself. The materials used in the construction are biocompatible and latex free.

    The modifications to the Vector TM PTA Balloon Dilatation Catherer are as follows.

      1. The balloon will be coated with Parylene C coating, referred to throughout as Parylene, providing a natural lubricity for insertion and withdrawal through the introducer.
      1. Each balloon catheter hub will be laser marked to include the balloon and introducer size, rated burst pressure and the product name, Vector" PTA. Balloon Catheter for customer convenience.
      1. The balloon protector ID for the 5x40mm balloon was increased slightly.

    There are no changes in the balloon catheter dimensions or significant changes in weight with these modifications ..

    AI/ML Overview

    The provided text describes a 510(k) summary for the Vector4™ PTA Balloon Dilatation Catheter. The document outlines device modifications and performance testing but does not contain the detailed information requested regarding specific acceptance criteria values, sample sizes for test sets (beyond stating "all devices met"), ground truth establishment methods, expert involvement, or multi-reader multi-case studies.

    Therefore, I cannot fully complete the requested table and answer all questions with the provided input. However, I can extract the available information and indicate where details are missing.


    Acceptance Criteria and Study Details

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Test PerformedStated Acceptance (Pass/Fail)Reported Device Performance
    Mechanical PerformanceBalloon rated burst pressureMet performance specifications"All devices met the performance specifications."
    Balloon complianceMet performance specifications"All devices met the performance specifications."
    Balloon Diameter SizingMet performance specifications"All devices met the performance specifications."
    Inflation/deflation timesMet performance specifications"All devices met the performance specifications."
    Repeat inflationMet performance specifications"All devices met the performance specifications."
    Removal, Refold and ReuseMet performance specifications"All devices met the performance specifications."
    Crossing ProfileMet performance specifications"All devices met the performance specifications."
    Balloon BurstMet performance specifications"All devices met the performance specifications."
    Material/IntegrityCoating integrity/ParticulatesMet performance specifications"All devices met the performance specifications."
    Design/CompatibilityBalloon ProtectorMet performance specifications"All devices met the performance specifications."
    Guide Wire and Introducer CompatibilityMet performance specifications"All devices met the performance specifications."
    Aging PerformanceAged Balloon Testing (Rated Burst Pressure, Compliance, Diameter Sizing, Inflation/deflation times, Repeat Inflation, Removal/Refold & Reuse, Flexibility/Kink, Crossing Profile, Particulate/Coating Integrity, Balloon Protector, Guide Wire/Introducer Compatibility, Balloon Burst)Met performance specifications after accelerated aging"The bench testing demonstrated that the device meets specifications before and after aging..."
    BiocompatibilityBiocompatibility (ISO 10993-1)Met requirements"the device is biocompatible meeting the requirements of ISO 10993-1."
    SterilizationSterilization (SAL 10⁻⁶)Met requirements"The device is sterilized by ethylene oxide to an SAL 10⁻⁶ level..."

    Missing Information: The specific numerical or qualitative thresholds for "performance specifications" for each test are not provided in the document.

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: The document states "All devices met the performance specifications" for the various tests. However, the exact sample size (number of devices) used for each test set is not specified.
    • Data Provenance: The tests are described as "bench testing" and conducted on "the modified Vector™ PTA Balloon Dilatation Catheter." This implies the data is prospective (generated specifically for this submission) and likely from an in-house or contracted lab, representing a controlled testing environment, not clinical data provenance (country, retrospective/prospective).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not Applicable: This device is a medical catheter undergoing bench testing for physical and material performance, not an AI or diagnostic device that requires expert-established ground truth for image interpretation or diagnosis. Therefore, no experts for establishing ground truth are mentioned or applicable in this context.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not Applicable: As this is bench testing of a physical device, not a diagnostic interpretation or clinical outcome, adjudication methods for ground truth establishment are not relevant. Test results would be objectively measured against predefined engineering specifications.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No: This is a physical medical device (catheter), not an AI-assisted diagnostic or imaging device. Therefore, an MRMC study is not applicable and was not performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not Applicable: This is a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not Applicable in the traditional sense: For a physical medical device's bench testing, "ground truth" refers to predefined engineering specifications, regulatory standards (e.g., ISO 10993-1 for biocompatibility), and design requirements. The device's performance is measured against these objective criteria.

    8. The sample size for the training set

    • Not Applicable: This submission describes the testing of a physical medical device, not the development or validation of an AI algorithm that would require a training set.

    9. How the ground truth for the training set was established

    • Not Applicable: There is no training set for a physical medical device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K121385

    Validate with FDA (Live)

    Device Name
    VECTOR
    Manufacturer
    Date Cleared
    2012-06-14

    (37 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vector " Thi PTA Balloon Dilatation Catheter is recommended for Percutaneous Transluminal Angioplasty (PTA) of the femoral, iliac, popliteal, and renal arteries and for the treatment of obstructive lesions of native or synthetic arterio-venous dialysis fistulae.

    The Vector Catheter is not indicated for use in the coronary arteries or for placement of or post dilatation of stents

    Device Description

    The Vector" PTA Catheter is a high pressure, non-compliant balloon catheter with a radiopaque coating on the balloon. The radio-opaque coating on the working length of the balloon minimizes or eliminates the need for using contrast solution to inflate the balloon. The radioopaque coating delineates the working length of the balloon and provides continuous fluoroscopic visibility during balloon placement. Saline may be used to inflate the balloon without affecting visualization. Contrast mixture may be used at the discretion of the physician.

    The Vector4™ PTA Balloon Dilatation Catheter is a coaxial dual lumen over-the-wire balloon dilatation catheter. The central lumen accommodates guide wires up to 0.035 inches in diameter while the outer lumen is the inflation lumen for the balloon. The catheter includes an atraumatic tip to ease advancement of the catheter to and through the stenosis. The distal tip is visible under fluoroscopy.

    The balloon is a high pressure composite balloon with a radiopaque coating on the working length to help visualize placement within the lesion during both placement and inflation without the use of contrast. The balloon's rated burst pressure is 30 atm.

    The catheter is supplied sterile and non-pyrogenic. Different balloon sizes (5 mm to 10 mm) and catheter lengths (50 to 135 cm) are available. The proximal end of the catheter contains a hub with two female luer locks.

    The device is compatible with 6-7F introducers. The introducer compatibility for each device size is listed on the device label itself. The materials used in the construction are biocompatible and latex free.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study information for the Vector™ PTA Balloon Dilatation Catheter, based on the provided text:

    Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Balloon rated burst pressureMet specifications
    Balloon complianceMet specifications
    Critical dimension verificationsMet specifications
    Guidewire and introducer compatibilityMet specifications
    Fluoroscopic visualizationMet specifications (comparable to predicate device, allowing visualization without contrast)
    Inflation/deflation timesMet specifications
    Repeat inflationMet specifications
    LeakMet specifications
    TensileMet specifications
    KinkMet specifications
    TorqueMet specifications
    CorrosionMet specifications
    Luer lock compatibilityMet specifications
    Coating integrityMet specifications
    DistributionMet specifications
    Biocompatibility (ISO 10993-1 for short duration contact with blood (<24 hour))Met specifications
    Sterilization (Ethylene Oxide to SAL 10⁻⁶ level)Met specifications
    Aging (Preclinical testing after accelerated aging)Met specifications
    Radiopacity (direct comparative testing with predicate)Similar to predicate device
    Particulates (direct comparative testing with predicate)Similar to predicate device

    Study Details

    • Sample size used for the test set and the data provenance:

      • The document describes "preclinical testing" of the device. It doesn't specify a numerical sample size for the test set or the provenance of any data (e.g., country of origin). The testing seems to be laboratory-based rather than involving patient data. This is a common approach for 510(k) submissions where a device is demonstrated to be substantially equivalent to an existing predicate device based on its technical characteristics and performance, rather than clinical outcomes. The studies mentioned are focused on the device's physical and mechanical properties.
    • Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. The ground truth for this type of device performance testing is based on engineering specifications and validated test methods, not expert consensus on clinical data.
    • Adjudication method for the test set:

      • Not applicable. As the testing is against engineering specifications, there wouldn't be an adjudication method in the context of clinical interpretation.
    • If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • Not applicable. This device is a medical catheter, not an AI-powered diagnostic or assistive tool for human readers. Therefore, an MRMC study related to AI assistance is irrelevant.
    • If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • Not applicable. This is a physical medical device, not an algorithm.
    • The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • The ground truth used for determining device performance was based on pre-defined physical and performance specifications for PTA catheters, industry standards (e.g., ISO 10993-1 for biocompatibility), and manufacturing requirements. For comparative aspects like radiopacity and particulates, the predicate device served as a benchmark for "similarity."
    • The sample size for the training set:

      • Not applicable. This device is not an AI/ML model that requires a training set.
    • How the ground truth for the training set was established:

      • Not applicable. As above, no training set is relevant for this device.

    Summary of Study Approach:

    The study described is a series of non-clinical, laboratory-based engineering and performance tests designed to demonstrate that the Vector™ PTA Balloon Dilatation Catheter meets its product specifications and industry standards. The submission relies heavily on direct comparative testing with a legally marketed predicate device (Bard Conquest PTA catheter) to establish substantial equivalence. Key areas of comparison include materials, construction, intended use, and critical performance characteristics like fluoroscopic visualization and mechanical integrity. The focus is on ensuring the new device performs equivalently or acceptably when compared to a device already deemed safe and effective.

    Ask a Question

    Ask a specific question about this device

    K Number
    K102135

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2010-10-22

    (85 days)

    Product Code
    Regulation Number
    870.2300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vector Event Grid Architecture System is intended for use in data collection from bedside and point of care biomedical devices and clinical information management systems either directly or through networks with independent bedside devices. The Vector Event Grid Architecture System is not intended for monitoring purposes, nor is it intended to control any of the biomedical devices and information systems with which it interconnects.

    Device Description

    The VEGA System permits the transfer of data from biomedical and patient care devices to existing hospital information technology and electronic medical record systems. The VEGA System connects directly to biomedical devices and aggregates the data from multiple biomedical devices for transmission to electronic medical record systems. The VEGA System may also translate native biomedical device data into the HL7 standard as necessary.

    AI/ML Overview

    The provided text is a 510(k) summary for the Nuvon, Inc. Vector Event Grid Architecture (VEGA) System, a device for collecting data from biomedical devices and clinical information management systems. It is not a detailed study report with specific acceptance criteria and performance metrics for a diagnostic or AI-driven device in the typical sense.

    Therefore, much of the requested information cannot be extracted directly from this document. The document describes a data retrieval system rather than a device with diagnostic or analytical performance claims that would typically involve sensitivity, specificity, or other statistical measures.

    However, I can extract the following information:

    1. A table of acceptance criteria and the reported device performance:

    The document does not provide a table of quantitative acceptance criteria or statistical performance metrics (e.g., sensitivity, specificity, AUC) because it's a data collection and transmission system, not a diagnostic one. Instead, it states qualitative performance outcomes.

    Acceptance Criterion (Implicit)Reported Device Performance
    Communication of biomedical device data from source devices"Results of verification and validation activities have shown that the VEGA System biomedical device data are communicated from the source devices through the system in a manner consistent with the expected performance."
    Functionality as intended"In all instances the VEGA System functioned as intended..."
    Fidelity of results"...and the fidelity of the results observed was as expected."
    Equivalence to predicate device for safety and effectiveness"The minor technological differences between the VEGA System and its predicate devices raise no new issues of safety or effectiveness."
    Substantially equivalent performance to predicate device"Performance data demonstrate that the VEGA System has substantially equivalent performance to the Data Captor System."

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    This information is not provided in the document. The document refers to "verification and validation activities" but does not specify the sample size, type of data used (e.g., specific biomedical device models, patient data), or its provenance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

    This information is not applicable/not provided. The device is a data retrieval system, not one that makes clinical diagnoses requiring expert ground truth for its performance evaluation in the traditional sense. Its evaluation would focus on data integrity, transmission accuracy, and interoperability.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    This information is not applicable/not provided. Adjudication methods are typically used for establishing ground truth in diagnostic studies, which is not the primary purpose of this device's performance evaluation as described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    This information is not applicable/not provided. The VEGA System is a data retrieval and transmission system, not an AI-assisted diagnostic tool. Therefore, an MRMC study comparing human readers with and without AI assistance would not be relevant to its function.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    The document describes the VEGA System as functioning independently to collect and transmit data. The performance section implies a standalone evaluation of the system's ability to communicate data accurately from source devices. However, the term "standalone" in the context of an "algorithm" is more typically associated with AI-driven diagnostic tools. Here, the device's function as a data intermediary is evaluated.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The concept of "ground truth" in the diagnostic sense (e.g., pathology, expert consensus) is not applicable to this device. For this type of system, the "ground truth" would likely be the actual data generated by the biomedical devices, and the performance would be validated by comparing the transmitted data to the source data for accuracy, completeness, and fidelity. The document states "the fidelity of the results observed was as expected," implying such a comparison.

    8. The sample size for the training set:

    This information is not applicable/not provided. The VEGA system is described as a data retrieval architecture, not a machine learning or AI algorithm that would typically require a "training set" in the context of supervised learning.

    9. How the ground truth for the training set was established:
    This information is not applicable/not provided for the same reasons as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K092467

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2010-05-06

    (267 days)

    Product Code
    Regulation Number
    882.4560
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BrainLAB Cranial IGS System is intended to be an intra-operative image guided localization system to enable minimally invasive surgery. It links a freehand probe, tracked by a magnetic sensor system or a passive marker sensor system to a virtual computer image space on patient image data being processed by the IGS workstation. The system is indicated for any medical condition in which the use of stereotactic surgery may be appropriate and where a reference to a rigid anatomical structure, such as the skull, a long bone, or vertebra, can be identified relative to a CT, CTA, X-Ray, MR, MRA and ultrasound based model of the anatomy.

    Example procedures include but are not limited to:

    Cranial Procedures: Tumor resections Skull base surgery Cranial biopsies Craniotomies/ Craniectomies Pediatric Catheter Shunt Placement General Catheter Shunt Placement Thalamotomies/ Palliodotomies

    ENT Procedures: Transphenoidal procedures

    Maximillary antrostomies Ethmoidectomies Spheno-idotomies/ sphenoid explorations Turbinate resections Frontal sinusotomies Intranasal

    Device Description

    The Cranial IGS System consists of the IGS workstation, the touch screen monitor and the 3D tracking system. A set of hardware accessories provides for comfortable and accurate use of the system.

    The IGS workstation holds the patient data during the surgery and runs the cranial software application.

    The patient data needed for the image-guided surgery is acquired pre-operatively or intraoperatively and is transferred to the IGS workstation via network, data carrier or data bus. The cranial software application offers the display of the patient data in various reconstructions, segmentations and overlays on the touch screen in addition to position information of tracked instruments – optionally combined with outlined information. The touch screen enables the control of the cranial software application and can be draped for sterile use by the surgeon.

    The electro-magnetic or optical 3D tracking system performs the localization of patient and surgical tools within the operating field.

    The virtual diagnostic image spaces are correlated ("registered") to the surgical environment by collecting the 3D position of anatomical landmarks or fiducial markers with a tracked pointer probe and relating them with the corresponding features extracted from the diagnostic image data sets. Alternatively, the patient's skin surface can be scanned with a laser device or touched with a pointer device and matched to the 3D reconstruction of the patient data set. If several diagnostic image spaces have been acquired from the same patient, only one of them has to be registered whereas the remaining ones can be fused to the registered data set.

    Intra-operatively acquired patient data can furthermore be correlated ("registered") to the surgical environment by determining its spatial position to the patient during its acquisition.

    Structures in the patient's body are localized using trackable pre-calibrated or intra-operatively calibrated surgical instruments. Examples of surgical instruments are the pointer tool, biopsy needles, catheter stylets or suction tubes.

    Surgical microscopes, ultrasound devices and endoscopes are additional intra-operative image sources, which are connected with the Cranial IGS System via signal transmission cables. They can be calibrated and tracked similar as any other surgical instrument. Their images can be displayed on the touch screen or external monitors and combined with the available patient data in correct spatial relation. The settings of microscope and ultrasound devices offering a communication interface can be controlled from the Cranial IGS System. Navigation information can be displayed in the microscope's image injection module. Defined components of the Cranial IGS System are prepared for the use in magnet-resonance environments.

    The Cranial IGS System contains hardware accessories and software features to improve the support and guidance of surgical instruments.

    The Cranial IGS System contains a network based software interface that allows downloading medical data (such as image sets, objects, trajectories or points) and tracking data from the system as well as to upload and display an image stream to the system. This interface can be used to implement custom visualization of medical data (e.g. included modalities which are otherwise unknown to the cranial software application) as well as to control other devices. These view data is strictly under the responsibility of the user and clearly marked as such.

    AI/ML Overview

    The provided text describes the Cranial Image Guided Surgery System, which includes the predicate devices VectorVision cranial, VectorVision ENT, Kolibri cranial, Kolibri ENT, Cranial Essential, Cranial Unlimited, ENT Essential, and ENT Unlimited. The modification discussed is the addition of a "Disposable Stylet." The document focuses on establishing substantial equivalence for this new accessory rather than presenting a detailed study with specific acceptance criteria and performance data for the entire system or the stylet.

    Therefore, the information regarding acceptance criteria, specific device performance, sample sizes, ground truth establishment, expert qualifications, and MRMC studies is not explicitly available in the provided text. The text primarily outlines the device's intended use, description, and the regulatory determination of substantial equivalence for the "Disposable Stylet" accessory.

    However, based on the information provided, we can infer some aspects related to testing for the "Disposable Stylet" and general regulatory context.

    1. A table of acceptance criteria and the reported device performance:

    Specific numerical acceptance criteria and reported device performance metrics are not detailed in the provided document. The submission focuses on demonstrating substantial equivalence, which implies that the device (specifically the Disposable Stylet) performs at least as well as the predicate device in its intended function.

    The text mentions:

    • "The added accessory 'Disposable Stylet' has been verified and validated according to BrainLAB's procedures for product design and development. The validation proves the safety and effectiveness of the system."
    • "Compatibility of the Disposable Stylet to third-party catheters has been shown in performance testing. Therefore the force necessary to extract the Disposable Stylet vs. third-party stylets out of catheters representing common boundary conditions like materials, coatings and sizes was measured. This had been done in air as well as in saline to simulate the intended use."

    This indicates that performance testing was conducted, but the specific acceptance criteria (e.g., maximum extraction force, accuracy of calibration) and the quantitative results are not provided in this summary.

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective):

    This information is not provided in the document. The text refers generally to "performance testing" and "studies" but does not specify sample sizes or data provenance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience):

    This information is not provided in the document. The testing described for the "Disposable Stylet" appears to be more focused on physical performance (e.g., extraction force) rather than expert interpretation of images or clinical outcomes that would require a ground truth established by medical experts for a test set.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    This information is not provided in the document.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    This information is not provided in the document. The device in question is an image-guided surgery system and a disposable stylet, which are tools for surgical navigation and instrument placement, not diagnostic AI systems for image interpretation that would typically involve MRMC studies.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    The device is an "intra-operative image guided localization system" that tracks a freehand probe relative to patient image data. It also includes the "Disposable Stylet" as a pre-calibrated guiding stylet. The nature of these devices inherently involves human interaction (the surgeon using the system and stylet). While the calibration of the stylet is "pre-calibrated" (meaning the software contains information optimized for it and user calibration is not necessary), the system itself is designed as a human-in-the-loop tool. Therefore, a purely standalone algorithm performance study, in the sense of a diagnostic AI, is unlikely to be relevant or described for this type of device. The verification and validation mentioned would likely involve testing the accuracy and reliability of the tracking system and the stylet's calibration.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    For the Cranial IGS System generally, the "ground truth" for navigation is derived from the patient's own diagnostic image data (CT, CTA, X-Ray, MR, MRA, ultrasound) which are then registered to the patient's anatomy during surgery. This is a form of image-based anatomical ground truth.

    For the Disposable Stylet, the "ground truth" for the performance testing cited (extraction force) would be the physical properties and measurements of the stylet and the catheters. The "calibration information optimized for the Disposable Stylet" stored in the software serves as its internal "ground truth" for tracking.

    8. The sample size for the training set:

    This information is not provided in the document. The device does not appear to be an AI/ML system that undergoes a "training" phase with a distinct training set in the typical sense. The software contains "calibration information optimized for the Disposable Stylet," which implies pre-determined parameters rather than a learned model from a large dataset.

    9. How the ground truth for the training set was established:

    This information is not provided in the document, as a "training set" and associated ground truth establishment (in the AI/ML sense) are not explicitly mentioned or implied for this type of device. The pre-calibration of the stylet would have been established through engineering and metrology processes to define its geometric properties to a high degree of accuracy.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 5